Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC | ₹34.9 L Quoted ₹35.2 L | L1 | Accepted-AOC Quoted rates lowest |
| 2 | L2₹38.5 L+₹3.3 L (9.47%)Rejected-Finance | ₹38.5 L+₹3.3 L (9.47%) | L2 | Rejected-Finance Quoted rates not lowest |
| 3 | L3₹38.9 L+₹3.7 L (10.5%)Rejected-Finance RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | ₹38.9 L+₹3.7 L (10.5%) | L3 | Rejected-Finance Quoted rates not lowest |
| 4 | L4₹39.3 L+₹4.1 L (11.6%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹39.3 L+₹4.1 L (11.6%) | L4 | Rejected-Finance Quoted rates not lowest |
| 5 | L5₹39.7 L+₹4.5 L (12.8%)Rejected-Finance | ₹39.7 L+₹4.5 L (12.8%) | L5 | Rejected-Finance Quoted rates not lowest |
Tender Value
Refer Docs
EMD Value
₹95,380
Closing Date
29 Mar 2021, 6:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT-10
SPECIAL REPAIRS TO BLDG NO P 09 AT RRRC UNDER GE CENTRAL DELHI CANTT 10
2021_MES_427337_1
CWE/D-73/2020-21
Open Tender
Civil Works
Item Rate
180 days
Delhi Cantt
As per NIT
7 documents required · 7 mandatory
₹500
GE CENTRAL DELHI CANTT
₹95,380
Yes
13 May 2021
2 Mar 2021
30 Mar 2021
2 Mar 2021
29 Mar 2021
16 Mar 2021
Amount
Demolition of brick work built in cement or cement mortar of any description including quoins,arches,pillars, etc. all as specified and directed by Engr-in-Charge.
M & L for brick work with Cement Mortar1:6 , using sub class 'B' bricks,old size , straightor curved on plan exceeding 6 m mean radius all as specified and directed by Engr-in-Charge.
Demolition Mud in roofs, any thickness, including plastering and leeping (whether full thickness emoved or only a part thereof) all as specified and directed by Engr-in-Charge.
Demolation Bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer all as specified and directed by Engr-in-Charge.
Removing soil excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed by Engr-in-Charge.
S&F in repair APP based polymeric menbrane minimum weighing 3 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150gms/sqm land on primed surface by forced application complete including 15mm thick in CM 1:4 all as specified and directed by Engr-in-Charge.
Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm including cleaning surface all as specified and directed.
Taking down cement plaster including racking out joints hacking for key scrubbing down with water etc on walls and ceiling all as specified and directed by Engr-in-Charge.
M&L for rendering 15mm thick on any face in cement mortar 1:6 finished even and smooth without using extra cement.to match with existing surface all as specified and directed by Engr-in-Charge.
M&L for rendering 15mm thick on any face in cement mortar 1:4 finished even and smooth without using extra cement.to match with existing surface all as specified and directed by Engr-in-Charge.
Material and labour for rendering 10 mm thick in cement mortar 1:3 on ceiling and finished even and smooth without using extra cement complete all as specified and directed.
M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for Preparation of Old surfaces (Plastered or un-plastered) of walls by completely scraping/removing the existing treatment and applying two coats of cement base paint complete all as specified and directed by Engr-in-Charge.
M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper over a coat of primer and 2-3 mm wall care putty (JK or Birla) complete all as specified.
M&L for Preparation of old surfaces (Plastered or un-plastered) of walls by completely scraping/removing the existing treatment and applying two coats of oil bound distemper over 2-3 mm wall care putty (JK or Birla) complete all as specified.
M & L for preparation of New surface (Plastered or un plastered) on ceiling and applying two coats of white wash over a coat of primer complete all as specified and directed by Engr-in-Charge.
M & L for preparation of Old surface (Plastered or un plastered) on ceiling by completely scraping/ removing the existing treatment and applying two coats of white wash over a coat of primer complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed.
M & L for coloured ceremic tiles of size 600 x 600 x 8mm thick as in floor over 15mm thick screed bed 1:6 in cement mortar, set and jointed in white cement with pigment to match all as specified and directed.
M & L ceremic tiles coloured of size 600 x 100 mm x 8 mm thick on vertical surfaces as in skirting etc over 10mm thick cement plaster in CM 1:4, set and jointed in white cement with pigment to match all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets all as specified and directed.
M&L for snap grid ceiling with E- bord 600x600mm and 4mm thick incl providind aluminium alloy anodised at edges 25x25x1.5mm along the pheripery of wall and tee section 38x38x1.5mm at intermediate intersections other then edges both ways fixed with 4mm dia GI wire complete all as specified and directed. . Make of board : Eco board/Bhutan board/archid ply
Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) complete from the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators,sockets,light fittings etc for credit and making good the disturbed surfaces of wall, floor etc complete all as specified and directed.
Taking down carefully sub main wiring of any description complete all as specified and directed.
Taking down defective switch fuse main board / distribution iron clad or sheet metal enclosure/ MCB DBs with MCBs of any capacity and make including wooden board etc complete all as specified and directed.
M & L for point wiring complete with, PVC insulated and unsheathed cable 1.5 sq mm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 including medium duty concealed unplasticised PVC conduit conforming to IS : 9537 ( Part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal boxes not less than 1.6 mm thick of required. size (factory made) including top cover 3 mm thick of plastic laminated sheets of required colour for fixing switch and sockets complete with all accessories and all as specified including PVC insulated and unsheathed cable 1.5 Sqmm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 of green colour as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete for following-
(a) One light /Ceiling fan/exhaust fan point controlled by one switch.
(b) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
(c) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
(d) One bell point controlled by one bell push.
(e) One light point controlled by two Nos two way switches
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 4 sqmm FRLS 1100 Volts in New PVC concealed conduit in new M S steel terminal boxes modular including one run of using 4 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one power point, all as specified and directed by Engr-in-Charge.
M&L switch Modular type 6 Amps, SP one way 230V AC complete all as specified and directed by Engineer in charge.
M&L switch modular type 6 amp SP two way complete all as specified and directed by Engineer in charge.
M&L Modular socket outlet 5 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
M&L switch bell push Modular type 6 Amps 1W-1 module, 230V AC complete all as specified and directed by Engineer in charge.
M&L switch Modular type 16 Amps 230V AC complete all as specified and directed by Engineer in charge.
M&L Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
Supply & Fix Modular five stepped type electronic fan regulator 2 module 360 degree rotatable type 230V AC complete all as specified and directed by Engineer in charge.
S&F ceiling rose surface PVC 65x50 mm type with three terminals complete all as specified and directed.
M&L bell electric (ding dong) 230 volt, SP all as specified and directed.
Supply & Fix UTP cat 6 information outlets suitable for 1 module on phenolic laminated sheet etc as required (LAN) complete all as specified and directed.
Supply & Fix RJ-11 Telephone socket with transparent shutter 1 module on phenolic laminated sheet etc as required complete all as specified and directed.
M&L for delux TV outlet with 1 module on phenolic laminated sheet etc as required complete all as specified and directed.
M &L telephone Point wiring complete with single pin 0.61mm dia copper conductor cable telephone pain taped and rip conforming to ITD specification D-3003 and ITI-113C/114C cable PVC insulated drawn though PVC concealed conduit not less than 20 mm dia for one 2 pin telephone socket out let on independent modular type board complete all as specified and directed.
S&F LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 100 systems lumens per watt with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 900 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥90 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
S&F 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S & F indoor LED panel recessed mounted lights with powder coated aluminium extrusion and smooth boarder suitable for 36 watt, >3600 lumen, IP-24 complete with all accessories incl making connection from ceiling rose to connector complete all as specified and directed.
Disconnecting elect connection and taking down of ceiling fan / Exaust fan of any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard complete all as specified and directed by Engr- in- Charge.
S&F ceiling fan 1400mm sweep including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor of size not less than 0.5 sqmm from ceiling rose to fan connector, length as per requirement at site and hook etc all as specified and directed by Engr in Charge.
M & L for opening up the winding of ceiling fan 1200 mm sweep any make any type and rewinding with super enamelled copper winding wire after inserting super enamelled insulating material binding it with insulating tape etc completely and varnishing well including drying completely. Replacement of worn out / unserviceable capacitor bearing , bush , safety pins, nuts, bolts, washers , rubber bush with ceiling fan clamp, cable PVC flexible 23/0076 and testing the ceiling fan after re-fixing of the blades to the entire satisfaction of Engineer-in-Charge.
S&F in repair fresh Air fan 230mm sweep with louvers including connecting with suitable size of copper conductor from ceiling rose to fan complete and making suitbale size, hole, for fixing etc all as specified and directed.
S&F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
S&F MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S&F MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply, and drawing in concealed PVC conduit not less than 20 mm dia medium duty incl 02 runs of single core 6.0 Sqmm(for main current) and one run single core 6 Sqmm (As earth wire) of multi stranded FRLS copper conductor PVC insulated unsheathed. 1100 volts grade, ISI marked for sub main wiring.
M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised strip and protection light grade GI pipe upto 7.5 mtr shall be deemed to be in the rates.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 32x6 mm thick galvanised strip duly fixed on suitable size of porcelain/ PVC insulator complete all as specified. Note- PVC/ Porcelain insulator are measured and paid separately.
M&L for fixing porcelain/ PVC insulator of suitable size to fix 32x6 mm thick GI strip as earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing at 0.60 m apart complete all as specified.
S&F 40W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.
Material & labour, jointing & testing XLPE insulated PVC sheathed armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 50 Sqmm 3.5 core duly fixed on PVC saddle and spacer complete all as specified and directed.
S&F for cable protection GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, laying of pipes etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers n. exc. 25 cm complete all as specified and directed.
Removal of excavation material not exc 50 Meter and depositing where directed at a level not exc. 1.5 M above the starting point complete all as specified and directed.
Supplying laying and cushioning for cable protection in trenches 8 cm thick layer before laying cable and 15 cm thick layer over the cable including well punning complete all as specified and directed.
Supplying laying sub class ‘B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
Supply,installation,testing,commissioning of LT Panel of size 900x900x200 mm cubical compartmentalized, indoor type wall/floor mounted suitable for 415 Volt 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with duly insulated copper bus bar of rating 200 amps mounted on epoxy/SMC type insulator. The Panel shall be dust and vermin proof IP 42 class protection and made out of 2.00 mm SWG CRCA sheet, powder coated finish outside,front openable type for cable entry with locking arrangement internal wirig with PVC insulated flexible copper conductor with the following incoming and outgoing feeders including the writting of qtr Nos on LT Panels. (a) MCCB 125A, 4 pole, 415volts 16KA=01 No (for incoming Mains and DG Set) Make:- Legrand or equivalent in L&T/SEIMENS/ ABB. (b) Euro- load change over switch 125 Amp, FP (c) MCB SPN 240 volts, 63 amps 10KA, C series -05 Nos Make- Legrand or equivalent in L&T/SEIMENS/ ABB. (d) MCB SP 6 to 32 Amp, 240 volts, 10KA, C series-1 Nos Make:- Legrand Cat No- 408587 , or equivalent in L&T/SEIMENS/ ABB. (e) Copper Bus bar 200A =1 set of four (f) Three Phase Static Energy Meter of Accuracy class 1.0, 240 Volts 50 Hz with Backlit LCD display, of rating 10-60 Amp (Measures & Displays kWh,V,I,kW,PF, last month history of kWh & MD in kW) with special features like TOD, Tamper logging Optical Communication Port & Display in Absence of Power- 01 Nos. Make : HPL/ L&T/ Secure (g) Set of indicating lamp(RYB) LED type -01
S&F concealed rigid non metalic conduit size 20 mm dia exclusive of boxes (junction/ terminal boxes) but inclusive of all tees, bends, reducers, bell mouth tube ends and fixing accessories including chase cutting and making good the disturbed surfaces complete all as spd and directed.
M&L junction boxes (1 to 4 way) complete all as specified and directed.
M/s Vijay Enterprises
SHREE RAM BUILD TECH
imran construction company
ARJUN CORPORATION
M/s Durga Traders
m/s VK construction company
JAIPAL AND BROTHERS
S.K. ENTERPRISES
GCVD INFRATECH PVT. LTD.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .