Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 CrAccepted-AOC | ₹22.5 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹25.0 CrRejected-Finance 216 C SIVA COLONY MAYO LINK ROAD AJMER RAJASTHAN 305007 | AJMER | RAJASTHAN | 305007 | ₹25.0 Cr | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹29.3 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹29.3 Cr | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹30.2 CrRejected-Finance PLOT NO G 36 SECTOR 20 NAVI MUMBAI 400614 | THANE | MAHARASHTRA | 400614 | ₹30.2 Cr | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not meeting eligibility criteria for enlistment as SS Class contractor |
Tender Value
₹20 Cr
EMD Value
₹13.3 L
Closing Date
21 Oct 2023, 6:00 pmClosed
CHIEF ENGINEER CG GOA
CHIEF ENGINEER CG GOA 403806
COMPLETION OF BALANCE WORK FOR PROVISION OF OTM ACCN PHASE II AT ICGAS RATNAGIRI
2023_MES_617336_1
81050/A/E8
Open Tender
Civil Works
270 days
RATNAGIRI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (I) CG RATNAGIRI
₹13.3 L
Yes
21 Nov 2023
5 Sept 2023
23 Oct 2023
5 Sept 2023
21 Oct 2023
7 Oct 2023
Amount
SCHEDULE ‘A’ PART-I (BUILDING & STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( SITE CLEARENCE, EARTHWORK AND EXCAVATION ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/ PATH/ CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIiI (COMPOUND WALL/ GATE/ CHAIN LINK FENCING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (SOLAR WATER HEATING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (LIGHTNING PROTECION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIV (LIFTS) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XV (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
INTERNAL WATER SUPPLY: Supply & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931. 15 mm nominal bore
Supply & fixing C.P. brass Two-way angle valve 15 mm nominal bore for EWC/AIWC points & for fixing Ablution Health Faucet of approved quality conforming to IS:8931.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Supply,Fixing on wall/roof and testing of cable PVC insulated, screened,PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavy duty) 1100 volts grade with stranded Copper conductor of size 25 sq mm 3.5 core including . note- rate is inclusive of cable gland & cable lugs.(From Main DB to Sub DB TPN 4 way)
Supply,Fixing on wall/roof and testing of cable PVC insulated, screened,PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavy duty) 1100 volts grade with stranded Copper conductor of size 50 sq mm 3.5 core including . note- rate is inclusive of cable gland & cable lugs.(From Main DB to Sub DB TPN 6 way)
Supply,Fixing on wall/roof and testing of cable PVC insulated, screened,PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavy duty) 1100 volts grade with stranded Copper conductor of size 95 sq mm 3.5 core including . note- rate is inclusive of cable gland & cable lugs.(From Main Panel Ground Floor to Each Floor DB of ATC building)
M&L for TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified.
M&L for telephone jak with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified.
Electric Energy meter 5-40 amps Direct Type DB Mounting with Communication with additional RS485 & WiFi module Direct current operated meter,Class 1 accuracy,Reverse current indication for three-phase meter
S &F modular Box sheet metal including cover Plate with socket 3 pin, suitable for 25 Amps flush type universal including 25 amp C series MCB protected.
Fabricate,supply & fix GI pipe bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 35w ssecurity light fitting
S&F modular white cover plate with frame 12 module Make Legrand, Schneider, hager or equivalent makes specified.
S&F modular white cover plate with frame 18 module Make Legrand, Schneider, hager or equivalent makes specified.
S&F modular metal flush box 1.0 mm thick , 12 module Make Legrand, Schneider, hager or equivalent makes specified.
S&F modular metal flush box 1.0 mm thick , 18 module Make Legrand, Schneider, hager or equivalent makes specified.
S & F RADIANT LED STEP LIGHT 7 watt LED ,Environmental friendly, new generation, energy saving, decorative rectangular shaped IP66 LED step light for wall recessed application.
Supply and Fix PVC slotted Cable duct B type including cover and all assocerries like bend ,end cap , tee ,Etc of Size B 80 mm wide x 60 mm height
Supply and installation of fast earth electrode 3.0 mtr length size model F84, having two M S pipe one inside the other with proper not deep galvanished outer dia 88 mm and inner dia 48 mm and the cavity between the rod pipes is filled with ground resistance improment powder, sealed with both end the outer pipe of electrode should be zink coated, the electrode should burried directly in the ground by making boring of diameter 10'' with boaring machine highly conductive non magnetic and non corrives is to be connected with GI strip 25 X 3 mm of 2 to 3 mtr length to facilitet further connection to earth dolly and provision of earthing chamber in bricks wall size 45 x 45 x 15 cm an dhaving PCC cover of required size complete all as directed and all as per IS 3034 (1981) Note: GI strip to be measured and paid seperately.
MCCB DB VERTICAL TYPE , suitable for 125 amps MCCB as incommer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 8 way Double door ,including cable end box at bottem & top of DBs, L&T CAT NO-DBVTL008DD/ LEGRAND / schneider/ ABB ( For ATC Sub DB -7 nos , ATC Garage-1 no , Single living Jcos -1 no)
MCCB DB VERTICAL TYPE , suitable for 125 amps MCCB as incommer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 6 way Double door ,including cable end box at bottem & top of DBs, L&T CAT NO-DBVTL006DD/ LEGRAND / schneider/ ABB ( For ATC Sub DB -7 nos , MI Romm -1 no , Pradhan Navic-1 no , Single living Officer -1 no)
MCCB DB VERTICAL TYPE , suitable for 125 amps MCCB as incommer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door ,including cable end box at bottem & top of DBs, L&T CAT NO-DBVTL004DD/ LEGRAND / schneider/ ABB ( For ATC Sub DB -3 nos , JCOs Mess -1 no)
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x40 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make-WIPRO /HAVELLS /JAQUAR /PHILLIPS
SEWAGE DISPOSAL: RCC septic tanks with upflow filter designed to carry sewage and sullage water , exc in any type of soil, foundation in PCC 1:4:8 below foundation , RCC M:30 , Design Mix in walls , Base slab , baffle walls and Roof slab including Beams etc with vent shaft , Manhole openings with cover connection etc, complete with effective depth of 1.5 mtr and overall depth of 3.0 mtr for 150 Users & including filter beds for 150 users
RCC septic tanks with upflow filter designed to carry sewage and sullage water , exc in any type of soil, foundation in PCC 1:4:8 below foundation , RCC M:30 , Design Mix in walls , Base slab , baffle walls and Roof slab including Beams etc with vent shaft , Manhole openings with cover connection etc, complete with effective depth of 1.5 mtr and overall depth of 3.0 mtr for 100 Users & including filter beds for 100 users
RCC septic tanks with upflow filter designed to carry sewage and sullage water , exc in any type of soil, foundation in PCC 1:4:8 below foundation , RCC M:30 , Design Mix in walls , Base slab , baffle walls and Roof slab including Beams etc with vent shaft , Manhole openings with cover connection etc, complete with effective depth of 1.5 mtr and overall depth of 3.0 mtr for 50 Users & including filter beds for 50 users
SOLAR WATER HEATER: Supplying, Installing, Testing and commissioning of solar hot water system (Flat plate collection) complete all as specified & directed
Fabrication /fixing of water tank staging made out of MS Angle iron 50x50x6mm/ MS Flat iron complete all as specified and as directed
S&F MCCB 3 Pole 125 A 18 KA complete all as specified and directed. ( for incoming of 50 KVAR APFC Panel)
S&F MCCB 3 Pole 400 A 36 KA complete all as specified and directed.( For incoming of 150 KVAR APFC Panel)
Supply and fix cable route indicator made of round CI disc embossed HT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B2 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
Supply,Install,test and commissioning of Trivector meter CT operated, three phase four wire TVM 110 Volt , 1 A/5A ,class 0.5s with box complete all as specified. Note:- Trivector meter will be got approval and tested from MSEB by the contractor and certificate there off will be produced to the GE .
Supply and fix Hot dip galvanised Iron octagonal pole of height 7 mtrs minimum galavnising of 70 microns, top 70 mm , bottom 130 mm and 3 mm sheet thickness in single section without any weld joints with square plate of minimum dimensions 225x225x12 mm, foundation bolts of sizeM-24x750 mm long - 4 nos, single arm GI bracket of 900x1000 mm for mounting the light fitting at an angle of 120 degree,backelite sheet with one 6 A SP MCB and 16 mm stud type connectors -04 nos inside the pole at the door opening for cable connections,common template s minimum 01 for each 15 poles all fixed and bolted on and including suitable RCC pedestal of minimum size 0.4mx0.4mx1.4m including form work as per manufacturers design & Drawing recommendations and specifications all as directed Mast and pole shaft shall be be as per BSEN 10025,IS 5986, ASTM A572 , Make of pole- Bajaj / Jindal /Crompton/Shubham-
Supply & Fix PVC insulated PVC round sheathed copper conductor (flexible) cable size 2.5 sqmm X 3 core,1100 Volt from street light junction box to fitting complete all as specified and directed.
Testing of Transformer at site Before Installation,testing and commissioning after installation , of Distrubution transformer ( EE Level 3) mounted on massonry platform step down 11KV /0.433KV, Three phase complying with IS:1180/IEC -76 (part-1) 2014 with latest ammendments, indoor type copper wound suitable for 50 Hz system of capacity 800KVA,Energy efficient Level-3, oil immersed naturally cooled delta connected on HT side and star connected on LT side, vector group Dyn 11 , provided with OFF load tap changer to vary secondary voltage from + 10% to -10% in step of 2.5% losses should be confined to the limits specified as follows : maximum allowable losses at full load (100%) & Half load (50%) shall not be exceeded 5.323 KW and 2.015 KW respectively as per GRIHA Rating, percentage impedence 5% . Losses and impedence are subjected to tolerance as specified in IS 1180. The transformer should be supplied with first filling of oil confirming to IS 335. The transformer shoud have both side cable end boxes with neutral brought out complete al as specified and directed by Engr-in-charge, and installation of transformer shall be carried out as per IS 10028 and comprising with the following standerd fittings/Technical specifications. (Near ATC Building) (PCC Platform for Trasformer will be Measured & paid seperatily under relvent item) (Note - New Transformer 800 KVA EE-level 3 , will be issued under Sch B free for Fixing)
Testing of Transformer at site Before Installation,testing and commissioning after installation , Distribution transformer (EE Level 3) mounted on massoniry platform stepdown , 11KV/0.433KV , Three Phase complying with IS: 1180/IEC-76(Part-1) 2014 with latest ammanmendts , Outdoor type double opper wound suitable for 50 Hz system of capacity 200 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side ,Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %. Losses should be confined to the limits specified as follows: :maximum allowable losses at full load (100 % ) & Half Load ( 50 % )shall not be exceeded 1.911 KW & 0.93603KW Respectivly as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028 and comprising with the following standerd fittings/Technical specifications : - (PCC Platform for Trasformer will be Measure & paid seperatily under relvent item)(Note - New Transformer 200 KVA EE-level 3 , will be issued under Sch B free for Fixing)
Supply and fix time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 32 Amp rating including MCB TPN 32 amps- 1 no and 3 phase contactor 40 amps - 1 no fitted in LT panel board, out door type, Degree of Protection IP 55/66, IP RatingIP55, Operating Voltage 440, Dimension 450x300x150. Fabricating supplying and mounting 3mm thick CRCA sheet , wheather proof with provision for better heat dissipation, provided with hinged front cover, equipped with ramper proof locking arrangement with suitable size clamps with necessary cable entry hole with gland and box should be finished Type of Control Panel 3 phase including all as directed and specified. Make : L & T, indo Asian,
Supply and installation of fast earth electrode 3.0 mtr length size model F84, having two M S pipe one inside the other with proper not deep galvanished outer dia 88 mm and inner dia 48 mm and the cavity between the rod pipes is filled with ground resistance improment powder, sealed with both end the outer pipe of electrode should be zink coated, the electrode should burried directly in the ground by making boring of diameter 10'' with boaring machine highly conductive non magnetic and non corrives is to be connected with GI strip 25 X 3 mm of 2 to 3 mtr length to facilitet further connection to earth dolly and provision of earthing chamber in bricks wall size 45 x 45 x 15 cm an dhaving PCC cover of required size complete all as directed and all as per IS 3034 (1981) Note: GI strip to be measured and paid seperately.
Supply and fix UPS for 30 min back up three phase AC input 360 to 460V and out put 415 V ± 1% of capacity 10 KVA, battery 12 V/26 AH 20 Nos and MS battery rack open type all as specified and directed.
DG SET: Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 750 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz supply, 1500RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following. (a)Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. Make of engine: KEOL / Kirloskar Electric / Ashok leyland / Cummins / Greaves, Make of Alternator: KOEL GREEN / Kirloskar /Stampford / Crompten / Jyoti/Greaves (a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter
(ii) Lube oil filter (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator. (n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump. (v) No of cylinders - 12 No VEE (w) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 24V Battery. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm
(v) Engine hours (vi) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop(x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-24 volts(2x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron).(z) Fuel tank: 12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed. (aa) Isolator panel with 1000 amp MCCB (ab) Auto logic panel for automatic stat (b) Alternator: Alternator suitable rated for 750 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof , insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves (c) Acoustic Enclosure:- M & L for acoustic enclosure for the above 750 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :- (i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt FTL fitting of make Phillips/ Bajaj/ Crompton.
(d) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, Outdoor type, IP-54, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 3.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: (e) AMF control circuit with 4 pole MCCB 1000 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc. (f) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate. Note :- DG set should be suitable as per CPCB -4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981.
Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 50 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz supply, 1500RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following. (a)Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including Mechenical governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. Make of engine: KEOL / Kirloskar Electric / Ashok leyland / Cummins / Greaves, Make of Alternator: KOEL GREEN / Kirloskar /Stampford / Crompten / Jyoti/Greaves (a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter (iii) By pass
(e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator. (n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump. (v) No of cylinders - 12 No VEE (w) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 24V Battery. (ii) Water temperature. (iii) lubricating oil pressure.
(iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop (x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-12 volts(1x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron). (z) Fuel tank: 12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed. (aa) Isolator panel with 80 amp MCCB (ab) Auto logic panel for automatic stat (b) Alternator: Alternator suitable rated for 50 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof , insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves nal Clean Air programme (NACP) Act 1981.
(c) Acoustic Enclosure:- M & L for acoustic enclosure for the above 50 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :- (i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt FTL fitting of make Phillips/ Bajaj/ Crompton. (d) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-43, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: (e) AMF control circuit with 4 pole MCCB 80 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc. (f) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate. Note :- DG set should be suitable CPCB -4 as per latest norm wef 01 July 2023 of Natio
Supply and installation of fast earth electrode 3.0 mtr length size model F84, having two M S pipe one inside the other with proper not deep galvanished outer dia 88 mm and inner dia 48 mm and the cavity between the rod pipes is filled with ground resistance improment powder, sealed with both end the outer pipe of electrode should be zink coated, the electrode should burried directly in the ground by making boring of diameter 10'' with boaring machine highly conductive non magnetic and non corrives is to be connected with GI strip 25 X 3 mm of 2 to 3 mtr length to facilitet further connection to earth dolly and provision of earthing chamber in bricks wall size 45 x 45 x 15 cm an dhaving PCC cover of required size complete all as directed and all as per IS 3034 (1981) Note: GI strip to be measured andpaid seperately.
LIFTS: Supply and installation of fast earth electrode 3.0 mtr length size model F84, having two M S pipe one inside the other with proper not deep galvanished outer dia 88 mm and inner dia 48 mm and the cavity between the rod pipes is filled with ground resistance improment powder, sealed with both end the outer pipe of electrode should be zink coated, the electrode should burried directly in the ground by making boring of diameter 10'' with boaring machine highly conductive non magnetic and non corrives is to be connected with GI strip 25 X 3 mm of 2 to 3 mtr length to facilitet further connection to earth dolly and provision of earthing chamber in bricks wall size 45 x 45 x 15 cm an dhaving PCC cover of required size complete all as directed and all as per IS 3034 (1981) Note: GI strip to be measured andpaid seperately.
EXTERNAL WATER SUPPLY: Supply and laying Ductile iron pipes with spigot and socket ends centrifugally cast, Class K-9, in any length laid in trenches of size 150 mm dia Incuding rubbur Tytan joint
Supply and laid spigot/flanged/ socketed DI fittings. Such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc of size 80mm to 300mm dia.
Supply and lay MS ERW Pipe, 450 mm dia 18", complete with all fitting & asccessries Testing after Installation including complete all as specified and directed by Engr - in- charge ( For Header )
Supply and fix CI foot valve, flanged end and drilled of size 100 mm dia ISI MARKED.
Supply and fix CI foot valve, flanged end and drilled of size 150 mm dia ISI MARKED.
Supply install test and commissiong of centrifugal pump set , electric driven complete with all accessories suitable for pumping water 26 LPS discharge at 50 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including , necessary connection from starter to motor terminal , PCC foundatation as recommanded by the OEM, anty vaibration paid,,connection of suction pipe from pump to foot valve, delivery pipe connected From Pump to the raising mains/ Header by means of suitable joints including painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed.Note : Suction and delivery pipes, copper cable from motor to starter shall be measured and paid under appropriate items
Supply and install test and commissioning monoblock type vacuum pump set (model KV -30,HP -3), suc/Del-32mm/32mm of electric driven 3 phase 415 V 50 HZ IP 55 protection suitable complete necessary suction side GI pipe medium grade , vibration paid & PCC foundation complete alongwith GI pipe and fixing arrangments etc all as specified and directed ( for Priming )
Supply install test and commissiong of centrifugal pump set , electric driven complete with all accessories suitable for pumping water 450 LPM discharge at 50 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including , necessary connection from starter to motor terminal , PCC foundatation as recommanded by the OEM, anty vaibration paid,,connection of suction pipe from pump to foot valve, delivery pipe connected From Pump to the raising mains/ Header by means of suitable joints including painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed.Note : Suction and delivery pipes, copper cable from motor to starter shall be measured and paid under appropriate items
Construction of brick masonry valve chamber of size 900x900x1200 mm (internal dia) suitable for 80 mm dia sluice valve with necessary earth work excavation plain cement concrete 1:4:8 using 40 mm graded stone aggregate 75 mm thick in cement mortar 1:6 15 mm thick plastering 1:6 inter nally including flooring and externally rep to 15 mm below ground level plain cement concrete 1:4:8 type B1 using 20 mm graded stone aggregate in coping MS sheet cover made out of 3 mm thick MS sheet flat iron frame and bracing with locking arrangement applying two coat of synthetic enamel paint including dismantling removing the existing damage chamber completely removal of debris to a distance not exce eding 50 mtr distance depositing where as directed by Engr - in- charge .
Supply and installation of fast earth electrode 3.0 mtr length size model F84, having two M S pipe one inside the other with proper not deep galvanished outer dia 88 mm and inner dia 48 mm and the cavity between the rod pipes is filled with ground resistance improment powder, sealed with both end the outer pipe of electrode should be zink coated, the electrode should burried directly in the ground by making boring of diameter 10'' with boaring machine highly conductive non magnetic and non corrives is to be connected with GI strip 25 X 3 mm of 2 to 3 mtr length to facilitet further connection to earth dolly and provision of earthing chamber in bricks wall size 45 x 45 x 15 cm an dhaving PCC cover of required size complete all as directed and all as per IS 3034 (1981) Note: GI strip to be measured andpaid seperately.
Supply of Microprocessor based constant current Technology water disinfection Equipment of 0.94Cum/ Hour capacity using Silver Ionization process based on Oligodynamic Technology .The water chamber is to be made of corrosion free Stain Pipes and SS 304 Capable to with stand a pressure of 10 LSC and with inbuilt Silver Electrode made from Pure silver after metallurgical treatment and chemical treatment for dissipating of minute Ionic Silver Disinfection suitable for dual Ionization Plant of 0.94 Lakhs liters Capacity ( 26LPS ) require 3units of 32 M3 /hr flow rate to get flow of 94m3/hr to fix in series .This Silver Electrode must also be Nontoxic to humans . All this will be mounted in Powder Coated mild steel cabinet 0 to 1.6 mm thick with universal lock and key for safety The control panel with electrode Ok Indication to show that the electrode is working clear Electrode indication to show that the Electrode is nearing completion for easy maintenance of the Equipment .The disinfectant produced by the electrode is totally nontoxic at the dosed levels as prescribed by WHO ( World Health Organization) Standard .The Equipment is suitable to operate on single phase 220 Volts ,50HZ Power Supply .
LIGHTNING PROTECTION: Supply and installation of fast earth electrode 3.0 mtr length size model F84, having two M S pipe one inside the other with proper not deep galvanished outer dia 88 mm and inner dia 48 mm and the cavity between the rod pipes is filled with ground resistance improment powder, sealed with both end the outer pipe of electrode should be zink coated, the electrode should burried directly in the ground by making boring of diameter 10'' with boaring machine highly conductive non magnetic and non corrives is to be connected with GI strip 25 X 3 mm of 2 to 3 mtr length to facilitet further connection to earth dolly and provision of earthing chamber in bricks wall size 45 x 45 x 15 cm an dhaving PCC cover of required size complete all as directed and all as per IS 3034 (1981) Note: GI strip to be measured andpaid seperately.
AIR CONDITIONING: Supply and install split AC units inverter technology, indoor unit & outdoor unit with copper condenser complete with cordless remote control unit and with in built air ioniser and filter for better indoor air plasma quality of capacity 2TR and minimum of 4 star rating.
Supply and install voltage stablizer for automatic operation, single phase copper wound naturally air cooled indoor type and desingned for input variation between 170 volt to 270 volt with output voltage stablized at 220/230 volt of capacity 5 KVA.
COOLING APPLIANCES: Supply, Installation testing and commissioning of water cooler partialy stainless steel, electric driven single phase having approximate storage cap 80 ltrs and cooling cap 40 ltrs per hours.(Make- Blue stae/Usha/Voltas)
Supply and fixing voltage stablizer for automatic operator single phase copper wound naturally air cooled indoor type and design for input variation between 170 to 260 volts with output voltage stablized at 220 volts of following capacity:- Capacity 1 KVA
AVAITION LIGHTS: Supply and fix aviation obstruction light of 9 W LED twin type twin with doom and other fixing accessories
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core. Note :- rate is inclusive of cable gland & cable lugs.
FIRE FIGHTING: Supplyand installation, testing and commissioning of 2C x 1.5 Sq.mm twisted pair copper cable ISI marked with proper clamping, supports and terminations..
Supply, installalled foam cylinder high pressure seamless steel gas flat type concave bottom as per IS-7285 of capacity 140 Lits capacity
Supply, installalled foam cylinder high pressure seamless steel gas flat type concave bottom as per IS-7285 of capacity 80 Lits capacity
Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner). As per IS 15683 - Dry chemical Powder type 09 Kg
Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner). As per IS 15683 - Mechanical Foam type 09 Kg
Supply, installation, of fire bucket (dry sand) As per IS 15683
Supply and Installed foam cylinder high pressure seamless steel gas flat type concave bottom as per IS-7285 of capcity 67.50 Ltr.
Supply and Installed NOVEC 1230 fire extinguishing solution/fluid for suppression system,non corrosive,non toxic,non-explosive,non flamble and harmless to people health as per EN standards and VDS/CNPP certificate complete all as per fire safety standards.
Supply and Installed master cylinder comprising of pressure guage with low pressure supervisory switch,pnuematic/manual actuator,flexible discharge hose including necessary connection etc complete.
Supply and Installed slave cylinder comprising of pressure guage with low pressure supervisory switch,pnuematic/manual actuator,flexible discharge hose including necessary connection etc complete.
Supply and Installed check valve as per manufacturers guidelines for distribution for NOVEC 1230 ensuring high velocity and mixing in the surrounding air complete.
Supply and Installed discharge nozzle as per manufacturers guidelines for distribution for NOVEC 1230 ensuring high velocity and mixing in the surrounding air complete.
Supply and Installed pressure switch/press box for indication for passage of gas in the pipe suitable for operating pressure of max 220 bar and release pressure minimum 3 bar and having interupting cap 250 Vda/5 Amps etc complete.
Supply & Install microprocessor based gas release panel with duel function of detection and controll realease circuit operating on 220 V AC supply with battery backup with provision of audio/visual indications as per EN-12094-1/EN54-2+A1/EN54-4+A2 standard.
Supply & Fix manifold fabricated from ASTM-A106 seamless pipe all as per manufacturer recommendation all as per actual site condition.
Supply & Fix carbon steelseamless pipes confirming to ASTM A 106 Gde B Sch 40 in walls ,ceilling including bends and fittings and fixtures for fittingto walls and ceillings
Supply and fix CI sluice valve Kirloskar/Upadhyay/L&T MAKE both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed of sizes :-150 mm dia
Supply and fix CI sluice valve Kirloskar/Upadhyay/L&T MAKE both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed of sizes :-100 mm dia
Supply and fix CI sluice valve Kirloskar/Upadhyay/L&T MAKE both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed of sizes :-80 mm dia
S&F Pressure gauge '4' dial 0-21 Kg rating.
S&F Pressure Switch universal type.
S&F Flow switch 100 dia
Detectors complying with and type certified to EN-45 addressable type heat detector with base with rate of rise cum fixed temperature as per IS:2175
S&F ICV/Alarm gong (intermittent hydraulic alarm gong and water motor alarm 150 mm .
S&F 4 way fire brigade inlet breeching having inbuilt non return valve with 4 nos of 63 mm GM instantaneous inlet on hydrent ring main.
S&F sprinkler flexible drop pipe 1 mtr long.
S&F sprinkler rossette 25 mm dia.
Supply and installation of fast earth electrode 3.0 mtr length size model F84, having two M S pipe one inside the other with proper not deep galvanished outer dia 88 mm and inner dia 48 mm and the cavity between the rod pipes is filled with ground resistance improment powder, sealed with both end the outer pipe of electrode should be zink coated, the electrode should burried directly in the ground by making boring of diameter 10'' with boaring machine highly conductive non magnetic and non corrives is to be connected with GI strip 25 X 3 mm of 2 to 3 mtr length to facilitet further connection to earth dolly and provision of earthing chamber in bricks wall size 45 x 45 x 15 cm an dhaving PCC cover of required size complete all as directed and all as per IS 3034 (1981) Note: GI strip to be measured and paid seperately.
AUDIO VIDEO AIDS: Supply and Fix Audio Vidio Aids complete system including Panasonic Projector,Projector Screen,Sennheiser Microphone-XSW 35,Sennheiser Microphone-XSW 12,Marantz Amplifire,Klipsh 7.1 Speaker,Wireless Presenter etc. complete all as spcified and as directed.
Supply and Fix Philips LED 55" LED video wall Display ,Full HD ,Model No :- BDL 5588 XL complete all as spcified and as directed.
Supply and Fix computer Intel core I5 6 generation with gigabyte Motherboard,8 GB RAM ,1 TB Hard Disc , LG DVD Writer I Ball ATX Cabinet, I Ball Key board and optical mouse ,Dell 18.5 "LED complete all as spcified and as directed.
ACOUSTIC WALL PANELING AND CELING IN BRIFING ROOM AT ATC BLDG: S&F Providing and fixing wall acoustical panelling using ecotone Slato Acoustic Panel make slats L-16 of size 128 mm x 2430 mm x 16 mm thick upto 2400 mm high as per the following specifications :- Slats L-16-3 mm @29 mm, Medium Denisty Fiber acoustic boards with Tongue & Groove Edge 2 mm slot perforation @ 16 mm centre, slates perforations, The acoustic should be furnished with a Black absorbent felt backing with an airflow resistance of 330-460 Ns/M³ (DIN 53887), wood practical core, NRC : should be upto 0.75, should meet the safety requirements of EN 14190. Fixing :- Sound structure CC18 screw fixed horizontal/ vertical to wall at every 600 mm c/c Metal cleat can be fixed on top edges of Sound structure CS55 fixed directly by stamping to the CS55 and IC91 which is screw fixed directly to the wall where ever required with a backing black color fabric as approved b Architect and as specified including all accessories, material & labor complete as directed by Architect/ Engieer-in-Charge.
S&F Providing and fixing wall acoustical ceiling with using ecogyp plain and perforated gypsum board of size 600 mm x 600 mm x 12.5 mm thick with 50 mm thick Rockwool acoustic gypsum boards with acoustic perforation – square 3 x 3 mm c/c. Rockwool of 50 mm/ 50kg density. The acoustic design panels should be with tapered long edges for easy joint filling, The acoustic Design panels are furnished with a grey (white) absorbent felt backing with an airflow resistance of 330-460 Ns/M³ (DIN 53887) Full perforated –A2-s1, do grind ceiling in true horizontal level 600 mm x 600 mm in 24 mm plain false ceiling grid system manufactured by ECOTONE using hot dipped galvanized steel section, exposed surface with precoated capping, Plain main tee size 24 x 32 mm having 0.30 mm guage cross at every 1200 mm. Centre to centre maximum and rotary stitched cross tee of size 24x32 mm, having 0.30 mm gauge at 600 mm c/c and sub cross tee size 24 x 24 mm having 0.30 mm guage at 1200 mm c/c and wall angle of size 24 mm x 24 mm, having 0.40 mm gauge fixed to the periphery of the wall. The above grid is suspended at every 1200 mm c/c in both directions using G.I wire. Composite panel ECOGYP-T manufactured by ECOTONE of size 595 mm x 595 mm x 12 mm (As per the specification of ECOTONE) complete all as specified and directed.
Tool and labour for chipping/ chiselling out offsets of cement concrete structural members evenly to size and shape complete all as specified and directed.
M&L rendering 15 mm thick on stone masonry surfaces or surface other than fair face of brick-work with ready mix plaster CM 1:6 complete all as specified and directed.
M&L 25 mm thick pre-formed filler in repair for expansion joints complete all as specified and directed.
Taking down 75 mm bore UPVC pipe including credit complete all as specified and directed.
JAIN BUILDER
SOOD ASSOCIATES PVT LTD
UBC Engineers Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid