| 1 | L1₹59.5 LAccepted-AOC 00 HANSH NAGAR RADHA RAMAN ROAD MAINPURI MAINPURI UTTAR PRADESH 205001 | MAINPURI | UTTAR PRADESH | 205001 | L1 | Accepted-AOC L-1 | |
| 2 | L2₹65.1 L+₹5.5 L (9.32%)Rejected-Finance N A | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical LATEHAR | LATEHAR | JHARKHAND | 822111 | - | Rejected-Technical Non Responsive | |
| 4 | Rejected-Technical | - | Rejected-Technical Non Responsive |
| Sl No | Description | Qty | Unit | S K ENTERPRISES L1 | M/S UNITED CONSTRUCTION L2 |
|---|---|---|---|---|---|
| 1.00 | Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I | 129.71 | Cum | 134.36 ₹17,427.84 Lowest | 146.89 ₹19,053.1 |
| 2.00 | Extra for earth work in hard soil as per specification & direction of engineer in charge (Vide classification of soil item B) | 97.27 | Cum | 13.73 ₹1,335.52 Lowest | 15.01 ₹1,460.02 |
| 3.00 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). | 69.85 | Cum | 48.92 ₹3,417.06 Lowest | 53.48 ₹3,735.58 |
| 4.00 | Supplying and stacking of good earth at site including royalty and carriage
upto 5 km lead complete (earth measured in stacks will be reduced by
20% for payment). | 120.3 | Cum | 456.31 ₹54,894.09 Lowest | 498.84 ₹60,010.45 |
| 5.00 | Providing coarse clean local Sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurement compacted volume) | 18.35 | Cum | 521.72 ₹9,573.56 Lowest | 570.35 ₹10,465.92 |
| 6.00 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. | 303.6 | Sqm | 292.35 ₹88,757.46 Lowest | 319.6 ₹97,030.56 |
| 7.00Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | |||||
| 7.01 | 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | 29.08 | Cum | 3,985.54 ₹1,15,899.5 Lowest | 4,357.07 ₹1,26,703.6 |
| 8.00 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). | 16.39 | Sqm | 246.34 ₹4,037.51 Lowest | 269.3 ₹4,413.83 |
| 9.00 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. | 20.16 | Cum | 4,522.58 ₹91,175.21 Lowest | 4,944.18 ₹99,674.67 |
Tender Value
₹67.2 L
EMD Value
₹1.3 L
Closing Date
30 Dec 2024, 11:00 amClosed
E.E., BCD, Building Division, Latehar
E.E., BCD, Building Division, Latehar
Construction of Model Storage Facilities for Seized Narcotics Drug and Psychotropics Substance, Latehar, Jharkhand.
2024_BCD_97019_1
22/2024-25/EE/BCD/LATEHAR
Open Tender
Civil Works - Buildings
Works
180 days
Latehar
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹1.3 L
Yes
15 Sept 2025
24 Dec 2024
31 Dec 2024
24 Dec 2024
30 Dec 2024
24 Dec 2024
Amount
Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I
Extra for earth work in hard soil as per specification & direction of engineer in charge (Vide classification of soil item B)
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
Providing coarse clean local Sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurement compacted volume)
Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, inishing and reinforcement - All work up to plinth level.1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal
Centering and shuttering including strutting, propping etc. and removal of form for
Centering and shutteing including struting, propping etc and removal of form for Foundations, footings, bases for columns, etc for mass concrete
Centering and shutteing including struting, propping etc and removal of form for Columns, Pillars, Piers, abutments, Posts and struts
Centering and shutteing including struting, propping etc and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shutteing including struting, propping etc and removal of form for Suspended floors, roof , landings , balconies and access platform .
Suspended floors, roofs, landings, balconies and access platform
Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for (Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.
10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
12mm to 20mm(TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Making 6X6mm grooves in plaster surface over walls truely horizontal or vertical as specified at regular intervals, at all heights including cleaning, finishing, scaffolding and curring with all leads and lift of water all complete as per building specification and direction of E/I.
Water proofrng for Old and New Roof Slab :- Providing and laying water prooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofi ng coating as per manufacturer specification-With following steps :-
(a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd.
/ MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat For the purpose of measurernent tte entire treated surface will be measured."
(c) :2nd Coat:- To apply the 2nd coat of two component acrylic modified,ready to-use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." Alter three days of drying the 2nd coal , the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification lo be done as per satisfation of E/c.
The Watqrproofing Brand:*Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A.Acrylic copol;,mer, Part 13 Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +270C Tensile Strength -2 N/mm2 after 28 Days (with Fibre cloth) (According to ASTM D 2370)Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.
4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Cloth (According to ASTM D 2370)
D Protection of treated with pcc :- The treated surface shourd be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( 1:120) towards the rain outlets in alternatepanels of 2 mtx2mt keeping 6 mm gap between the panel joint. integral water proofing admixture conforming to lS 2645 @ of 100 ml perbag of of cement to be added in the screed concrete (paid separately for thts ltems
all corners shall be charfered with 150mm X 150 mm fillet. The rain water outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose of measurement the entire treated surface will be measured."
(e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc
Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) raintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr
Provrding and filling of Groove between 25 mm PCC Panels with Polyshlphide Sealant (Poring Grade)as per drawings and technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Glazed Vitrified tiles MatUAntiskid finish of size of Tile 600 x 600 mm
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Grainite of any colour , 18mm thick (slab area above 0.50 Sqm)
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
Finishing walls with textured exterior paint of required shade : - New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Lettering with black Japan paint of approved brand and manufacture
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I.
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I.
Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1. 70 mm for Series R 1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 (ii) Sites with structure height more than 20m for all wind speeds
Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre).
Structural steel work in single section, fixed with or without connection plate, including cutting, hosting, fixing in posining and applying a primer coat of approved steel primer all complete.
Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I.
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge
150 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer?in-charge
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge
Carrage of Material
Bricks = 8 km (7+1)
Sand = 15 km (10+5)
Stone chipes = 30 km (25+5)
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to125.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Supplying all material, lobour, equpment for lowiring blue UPVC casing pipe as casing for protecting the side from falling during the process of drilling all complete including carriage of material
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stage 2 HP
PVC/XLEP insulated PVC sheated heavy duty, armoured electrical cable with aluminium conductor for working voltege up to and including 1100 volts. (conforming to IS : 1554, part -1)
6 sq.mm 2 core
120 sq.mm 3.5 core
63 amp. Four pole,on load chang over switch in sheet enclouser with side handle operation
Medium density polyethylene pipe (MDEP) in standerd length with necessary Jointing material like mechanical connector i.e. thered/insert joint / quick relese coupler joint/* comperssion fitting joint or flange conforming to ISO: 4427 : 1996 - MDEP pipe of material grade PE- 80 PN 16 (dia in mm)
40 mm dia
Polythene water storage tank of mark with cover and suitable locking system in double layer conferming to IS : 12701-1996 with letest revision
Providing and fixing brass / C.I. Stop cock of approved quality all complete as per specification and direction of E/l.
A) BRASS STOP COCK
C) 25 mm dia
(d) 32 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
Concealed work, including cutting chases and making good the walls etc.
15 mm nominal dia Pipes
25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
External work
25 mm nominal dia Pipes
32 mm nominal dia Pipes
100 mm nominal dia Pipes
80 mm nominal dia Pipes
50 mm nominal dia Pipes
Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C. With 'P' trap of parry hindustan or any other approved I.S.S. Make including supplying and fixing 15 litres C.I. Mosquito proof low down flushing cistern of approved make with complete fittings With C.I. handle and R.S. or bracket with telescope flush pipe with brass coupling and plumbers joints spindle stop cock of approved uality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved pain over a coat of red oxide priming all complete as per specification and direction of E/I.
(B) E.W.C. with "S" trap (b) 12.5 lit. low level PVC cistern
Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthenware urinal of "Hindustan" " Parry" or any other approved I.S.S. make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15 mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grms. , 15 mm P.V.C. alkathene pipe 450 mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with 2 coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/l.
(A) Flat back or standing corner ( 450 mm x 350 mm )
Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed C.l. or R.S. brackets 32 m C.I. brass waste 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32 mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l.
Providing and fixing lead connection pipe with heavy quality brass coupling 2 Nos. at both ends etc. all complete as per specification and direction of E/l .
( b) 15 mm dia and 45 cm long
Providing and fixing N.P/C.P brass/P.V.C porcelain shower rose of 15mm inlet etc. all complete as per specification and direction of E/l
(c) 150 mm dia P.V.C. shower
Providing and fixing male ended 15 mm dia brass bib cock of approved quality (wt not less than 350 gms) with extra socket all complete as per specification and direction of E/l.
Providing and fixing 15 mm size C.P brass pillar cock (Weight not less than 350 gms) C.I body brass spindle pillar cock of approved quality as per specification and direction of E/l.
(b) C.I. body brass spindle
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/l.
Glass Shelf with C.P. brass rail
(i) 600 x 125 mm glass self complete
(b) Mirrors of 4 mm thick plate glass bevelled edge mirror including C.P. brass revolving fitting, 3 mm plywood bord and C P hing to fix with mirror
i) 600 x 125 mm thick
i) C.P. brass towel rail 20 mm x 600mm with bracket container
ii) C.P. brass soap dish container medium quality with screw and hing etc.
iii) C.P. brass liquid shop container
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
75 mm diameter
110 mm diameter
Providing & supplying in standered length high density plyethylene pipe (HDPE pipe) conferming to IS 4984/14151/12786 (letest revition with necessary joining material like mechanical connectror i.e. threted / insert joint / quick realese coupler joint / compresssion fitting joint or flang joints including coupler / special and texess)
Grade PE 80- PN - 10
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion
75 mm Coupler
100 mm Coupler
75 mm Single pushfit Coupler
100 mm Single pushfit Coupler
75 mm Single tee with door
100 mm Single tee with door
75 mm Single tee without door
100 mm Single tee without door
75 mm bend 87.5°
100 mm bend 87.5°
75 mm Shoe (plain)
100 mm Shoe (plain)
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1 :4 (1 cement: 4 coarse sand) and making good the wall etc. complete. - 110 mm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 95 sq mm but not exceeding 185 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Suplying and making cable route marker with cement concrete 1:2:4 (1 Cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each
Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required.
Providing and laying earth connection from earth electrode with 4mm dia copper Wire in 15mm dia G.I. pipe from earth electrode, as required.
S/F rewireable double pole/ TP&N switch disconnector :- Providing and fixing following DP/TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuses, including drilling holes in metal board . making connections. etc. as required.
16 amps, double pole
32 amps, double pole
63 amps, double pole
32 amps, TP&N
63 amps, TP&N
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
25 - 100 amps, 10 KA fixed thermal setting
25 - 100 amps, 16 KA, fixed thermal setting
125 amps, 16 KA, fixed thermal setting
Providing and fixing following capacity busbar chamber with 4 strips of length 300mm made of copper suitable for following capacity complete with all accessories including connections, earthing the body etc. as required.
Providing and fixing following capacity 2 pole/ 4 pole ON/OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board including drilling holes in metal board, making connection, earthing the body etc. as required.
32 amps, 2 pole
63 amps, 2 pole
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (8 + 12), Double door, Vertical type
8 way (8 + 24), Double door, Vertical type
Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required.
6/32 amps, Single pole
40 amps, Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required.
Group - A.
Group - B
Group - C
Wiring for twin control point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way with modular switch, modular plate suitable GI box etc as required
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire
2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
2 x 4.0 sq.mm + 1 x 4.0 sq.mm earth wire
2 x 6.0 sq.mm + 1 x 6.0 sq.mm earth wire
2 x 10 sq.mm + 1 x 6 sq.mm earth wire
Supplying and fixing stepped type electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size / modules , GI box along with modular base & cover plate for modular switches in recess etc as required.
1 or 2 module (78mm x 78mm x 45mm)
4/5 module (78mm x 140mm x 50mm)
6 module (78mm x 205mm x 50mm)
8/9 module (78mm x 230mm x 60mm)
12 module (135mm x 205mm x 60mm)
Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch. connection, painting etc. as required (For light plugs to be used in non residential buildings)
Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 5/6 amps modular switch. connection, painting etc. as required (For light plugs to be used in non residential buildings)
Supplying and fixing 2 pin 5 amp. Ceiling rose on the existing junction box/ wooen block including connection etc. as required .
Supplying and fixing Batten / Angle holder including connection etc as required .
Supplying and fixing Ding-Dong sound call bell single phase. 230 volt, complete as required
Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required.
1200mm (48") Ceiling Fan
Installation of exhaust fan upto 450mm sweep in the existing opening , including making the hole to suit the size of the above fan, making good the damage, connection , testing , commissioning etc . as required
12" (300mm ) metal exhust fan
S.I.T.C of floowing rating reccess/surface mounted LED round/square shape Down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/section-2 or IEC:62722 with all neccssary accessories as required
12W LED Round Down light
Approved make wall mounted decorative lamp with nikel / crome finish with opal glass of lamp type E/27 E/22 Led 7/9 W x 2 IS : 10322 part 5
S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-5 and shall be complete with all neccssary accessories as required
90/100 W LED Flood light
2.0 Tr. Star split AC ( Interver type) IS - 1391 - part - 1
Copper tube of size 3/8" for split ac unit 1/1.5/2/3 Tr. Capacity including nitride ruber insulation
Drain pipe for AC
Outerdoor stand for 2 Tr. Split AC
5 KVA online UPS three phase input & output three phase output power system of input, voltege rang 360V/380V/400V/ 485V rang 415VC +/- 1% frequency rang 50Hz +/- 1% power factor 0.8/3.1, harmonic distribution - <2% THD (liner load) 5% THD (non - linear Load)
MS battery rack suitable for 15-20 UPS battery installation
100Ah tublour lead acid battery with 36 month replacement gruntee IS : 1652: 1991
Lifeguard (4kg clean agent type fire Extinguisher)
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment)
Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : 2.4.3 - Screened through sieve of I.S. designation 4.75 mm
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)
Providing and displaying of Phoenix palm having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and displaying of Raphes palm having ht. 45 cm to 60 cm with 5 to 7 suckers, well developed, full of fresh and healthy leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and stacking of Bauhinia tomentosa (yellow) of height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge
Def PRIME SRD + GG CL - C BIS KL
CP PLUS IP Dome Camrea - Model - CP-UNC-DA21PL3-0360
CP PLUS IP Bullet Camrea - Model - CP-UNC-TA21PL3-0360
32Ch NVR 200 MBPS 2 SATA Model - CP- UNR- 4K4322-V3
Hard Disk 10TB Enterprises 24*7 Survilence (WD) PURPLE - Model - WD101PURZ
Hard Disk 4TB Enterprises 24*7 Survilence (WD) PURPLE - Model - WD40PURZ
CP PLUS POE With Gigabit - Model - CP- DNW-HPU8G2-96
LG Monitor
CAT6 Cable DLINK 305 MTR (23AWG SOLID)(in Bundle)- Model - NCB-C6UGRYR-100
D-LINK 6U RACK - Model - NWR-6U-5045-GR
D-LINK RJ 45 Connector (in Box) - Model - NPG-SEITRA031-100
Vault safe locker
Add 18 % GST (in Basic Rate must fill 12)
Add 1% Labour Cess (in Basic Rate must fill 1)
M/S UNITED CONSTRUCTION (BID ID -641500)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .