Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹28.2 LAdmitted-Finance PLOT NO 112 PHASE IX IND AREA SAS NAGAR MOHALI | -3.11% | ₹28.2 L | L1 | Admitted-Finance |
| 2 | L2₹28.3 LAdmitted-Finance 0 A K ENTERPRISES SADAR ROAD BALOD GANGA MAIYA BOOK DIPO NEAR BALOD CHHATTISGARH 491226 UDYAM CG 17 0002983 | BALOD | CHHATTISGARH | 491226 | -3.03% | ₹28.3 L | L2 | Admitted-Finance |
| 3 | L3₹28.3 LAdmitted-Finance | -2.99% | ₹28.3 L | L3 | Admitted-Finance |
| 4 | L4₹28.3 LAdmitted-Finance CHANDIGARH CHANDIGARH | NA | NA | 160001 | -2.96% | ₹28.3 L | L4 | Admitted-Finance |
| 5 | L5₹28.6 LAdmitted-Finance CHANDIGARH | -2.00% | ₹28.6 L | L5 | Admitted-Finance |
Tender Value
₹29.1 L
EMD Value
₹58,276
Closing Date
23 Feb 2026, 12:00 pmClosed
University Engineer
Estate Office PEC
Repair and Renovation of B Tech Lab in Chemistry Department
2026_PEC_90691_1
PEC/EO/26/04
Open Tender
Civil Works
120 days
PEC Sector 12
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹58,276
13 Mar 2026
16 Feb 2026
23 Feb 2026
16 Feb 2026
23 Feb 2026
16 Feb 2026
Civil Work
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Glazed vitrified floor tiles polished finish of size
Size of Tile 600x600mm
Size of Tile 600 x 1200 mm
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:4 (1 cement: 4 fine sand)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
Two coats
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer- in-charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area 3 sq. metres and below
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead
Of area 3 sq. metres and below
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in- harge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately
Kiln seasoned and chemically treated hollock wood
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading,transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil
Pipes, cables etc, not exceeding 80 mm dia.
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level in all shapes and sizes in : DSR 6.4
Cement mortar 1:4 (1 cement : 4 coarse sand) : DSR 6.4.1
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen counters,window sills, acias and similar locations of required size of approved shade,colour and texture laid over 20mm thick base cement mortar 1:4(1cement 4coarse sand) with joints treated with white cement,mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edge to give high gloss finish etc.complete at all levels.DSR No.8.2
Granite of any colour and shade DSR No.8.2.3
Area of slab upto 0.50 sqm DSR No.8.2.2.1
Area of slab over 0.50 sqm DSR No.8.2.2.1
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors
100 mm inlet and 75 mm outlet
Sand Cast Iron S&S as per IS- 3989
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, including cutting chases and making good the walls etc.
15 mm dia nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe including painting with anticorrosive bitumastic paint, cutting chases and making good the wall:
15 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
External work
20 mm dia nominal bore
25 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
20 dia nominal bore
Providing & fixing of ball valve (brass) of approved quality High or low Pressure, with plastic floats complete;
20mm dia nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
20 mm dia nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. Brass extension nipple (size 15mm x 50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
100x100mm size P Type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing Drip Seal joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :
Providing and fixing of GI Tank Nipple of size 20 mm dia of approved make complete
P&F of Chinaware rectangular laboratory Sink complete with C.I. MS brackets, C.P. waste 32 m.m. as per standard pattern i/c cutting and painting of brackets and making good the wall complete in all respect. Make Jaguar / Cera /Hindware or equivelent as per approval of EIC
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :
2nd class teak wood
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
1.0 mm thick
Renewing glass panes and refixing existing wooden fillets:
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm)
Providing and fixing plain bend of required degree.
100 mm dia
Sand cast iron S&S as per IS : 3989
Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710/HDMR Board of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-in- charge.( Century/ Greenply/Duro/ asian/Marino)
Providing and fixing 2mm thick 16 to 19mm wide PVC edge binding tape of approved quality for cupboard/wardrobe shutters including necessary synthetic resin hot pressed to edges on binding machine etc. complete as per directions of Engineer- in-charge.
providing and fixing of 6 mm thick one side lamination BWP grade marrine ply of approved make (Duro/ Green/ Century/ Marrino) i/c necessary nails screws adhesive etc. complete as per the direction of EIC
Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710/HDMR Board of approved brand )including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.)( Century/ Greenply/Duro/ asian/Marino)
Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
Providing and Fixing SS soft closing hydroulic type spring hinges on cubboard shutters complete in all respect
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for
Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Cold twisted bars
Providing and Fixing CP Bib Cock Long body with long liver arm handle complete as per the approval. Make Jaquar/ Cera/ Kerovit or equivalent
Providing and Fixing CP Sink cock long arm complete as per the approval. Make Jaquar/ Cera/ Kerovit or equivalent
Providing and fixing of PVC pipe and special of approved make including jointing with cement solvent
90 mm dia x 6kg/cm2
75 mm dia x 6kg/cm2
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on inter- locking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross- T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles
Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make (Make: Hettic/ Haffele or equivalent)500 mm long with screws etc. complete as per directions of Engineer- in-charge.
Electrical Work
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150nnm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 2nos 3 pin 5/6 Amp modular socket outlet and 2 nos 5/6 Amp modular switch , connections etc as required.( For light plugs to be used in non residential buildings )
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100/63 A,16KA,FPMCCB
250 A,36KA,FPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MOB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Double pole
Triple pole pole
Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.
For 4 way, Double door TPN MCBDB
For 8 way, Double door TPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.Makes - Havells-Efficiencia Neo/Orient- Ecotech Supreme/Crompton-Energion Riviera /Bajaj- ENERGOS-28 only
Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, compatible to electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.Makes- Havells-Efficiencia Neo/Orient- HECTOR 500/Crompton-Energion Riviera /Bajaj- ENERGOS-28 only
Supply installation testing and commission of 250mm fresh air fan 1325- 1350 RPM in plastic body Off- white /White color. The job includes Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Makes- Bajaj-Maxima DXL-GO2/Crompton- Brisk Air /Havells-Ventil air- DX/Orient
Making hole for installation of exhausht fan/fresh air fan of size upto 450mm sweep by demolishing brick work manually/by mechanically means including disposal of malba within 50 mtr. lead and making good the wall by plastering etc as required.
Supply ,installation, testing and commissioning of recessed type down lighter 12 watt of 4000K/5700K/6500K (as approved by engineer in charge) having synthetic/powder coated pressure diecast alulminium body having high efficiency diffuser with more than 85% transmittance with rated life of L-70 @50,000 hours having system lumens more than 1200 lumensand efficacy better than 110 lumens/watt with CRI >80 and drivers efficiency >85% , THD less than 10% with inbuilt surge protection minimum 2.5 KV. The job includes fixing down lighter and connection with 3x1.5sqmm copper wire upto 1.5mtr length from adjacent light point with all petty material and labour required to complete the job in all respect. Makes Havells-ZIVA-DRRD-DLR -12W LED/ Wipro-LD06-151XXX-HE/ Panasonic-PDLM35-12W/ Philips-Green perform sleek DN295B-LED15S-PSUWH
Supply ,installation, testing and commissioning of recessed type LED panel 2'x 2',having CRCA housing duly painted with diffuser, minimum 4200 lumens (120 lumens/watt),5700K/6500K and 50000 burning hours of make Philips RC 380-B LED 42S-6500-G6/ Wipro CRCO10R036HE57G3 / Havells PLANO 2X2 PLR 36W LED865TAPS/Bajaj-BZRSQL43L-LEDGXPROWH.The job inculdes the cost of testing, commisisoning and making connection with 3*1.5 sq mm copper wire upto 1.5mt from adjacent light point, other petty material and labour etc as required to complete the same to the entire satisfaction of Engineer in Charge.
Supply,installation, testing and erection LED box type fitting with single ended connections, made of CRCA sheet and suitable for 1x18/20 watt LED tube rods including cost of 1x18/20 watt LED tube rods. Specification of LED tube rods should be -miniumum 2000 lumens per rod, extruded aluminium heat sink with polycarbonate diffuser 50,000 burning hours and others standard specifications as per OEM. The job inculdes Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.Makes of fitting and LED rods should be of Philips/ Wipro/Bajaj/Havells/Crompton.
Supply and erection of fan rod made of seemless MS pipe dia duly powder coated complete in all respect. Make National
18" length
24" length
30" length
36" length
48 " length
Providing and fixing of MS 10mm dia U type fan hook which includes fixing in the steel bar of RCC slab and repairing the same in good condition.
Supply, erection testing and commissioning of UTP cat 6 information outlest (RED for Data- User End) complete in all respect upto the entire satisfaction of Enigneer In-charge of the work make- Molex/R&M/Semon/D-Link
Supply, erection, testing and commissioning UTP face plate (Single/dual) along with modular box75mmx75mm complete in all respect upto he entire satisfaction of Enigneer In-charge of the work make- Molex/R&M/Semon/D-Link
Supply, installation, testing and commissioning of Inverter Split AC 1.5 TR capacity, 3 star rating with Refrigerant R-410/R-32 Gas with with ISEER in range 3.80 to 4.39 , Cooling Capacitty >= 5000 Watt . AC shall be suitable for 230 Volts+- 10% Volt ,50 Hz, Single phase , other standard manufactures Specification including installaltion charges complete in all respect upto the entire satisfaction of Engineer-in Charge. Make :- Daikin/Carrier/Hitachi/ Voltas
Supply, installation, testing and commissioning of Inverter Split AC 2TR capacity, 3 star rating with Refrigerant R-410/R-32 Gas with with ISEER in range 3.80 to 4.39 , Cooling Capacitty >= 6200 Watt . AC shall be suitable for 230 Volts+- 10% Volt ,50 Hz, Single phase , other standard manufactures Specification including installaltion charges complete in all respect upto the entire satisfaction of Engineer-in Charge. Make :- Daikin/Carrier/Hitachi/ Voltas
Providing and Fixing of Voltage Stabilizers of (3 stage) MS Body ( powder coated) with Copper winding Input range 160 to 280 Volts, Nominal output-230 Volts±10% Including cost of copper wire from stabilizer to AC unit and power plug complete in all respects Make Deol/Jewel /V-guard.
3 KVA capacity
4 KVA capacity
5 KVA capacity
Providing & Fixing of Powder coated ready made heavy duty out door stand for Split out door as per site requirement to the entire satisfaction of Engineer- in Charge.
Providing and Fixing of PVC Rigid drain Pipe surface/recess in wall / floor with necessary repair to the original condition, complete in all respects from indoor unit to Disposal Points as directed by the E.I.C. Size ¾” including specials- Make- Diplast or Equalivent.
Providing and Fixing of 22 gauge soft copper piping of size 3/8” & 5/8” or as per original manufacturer of A/C size, for Liquid & Suction sides, between indoor & outdoor units with 6 mm thick nitrile rubber insulation & protective covering for exposed weather including cost of chasing brick wall/RCC wall & repairing to original condition.Make Rajco., Mandev, Totaline.
Providing & fixing of 4 core 2.5 sqmm flexible coppe wire ISI Marked complete. Makes Havell/Polycab as per site.
Supply and erection of Modular type DP switch 32 Amp 250 Volt along with modular box, modular base and cover plat 2 module complete in all respect.Make Legrand (Lyncus)/ABB (Tvisha/ Gold Medal(GIFA) Crabtree (Athena)
Supply ,installation, testing and commissioning of Surface type LED panel 2'x 2',having CRCA housing duly painted with diffuser, minimum 4200 lumens and 50000 burning hours of make Philips - RC-380B-LED 42S-6500G6 / WIPRO-CRC 010R036HE57G3 / Havells-Plano G2S- 36W / Bajaj-BZSSQL45 LED WH GX MT.The job inculdes the cost of testing, commisisoning and making connection with 3x1.5 sq mm copper wire from adjacent light point, other petty material and labour etc as required to complete the same to the entire satisfaction of Engineer in Charge.
Supply ,installation, testing and commissioning of recessed type down lighter 9 watt of 4000K/5700K/6500K (as approved by engineer in charge) having synthetic/powder coated pressure dia-cast alulminium (Maximum cutout dia 110mm) body having high efficiency diffuser with more than 85% transmittance with rated life of L-70 @50,000 hours having system lumens more than 1200 lumensand efficacy better than 110 lumens/watt with CRI >80 and drivers efficiency >85% , THD less than 10% with inbuilt surge protection upto 2.5 KV. The job includes fixing down lighter and connection with 3x1.5sqmm copper wire upto 1.5mtr length from adjacent light point with all petty material and labour required to complete the job in all respect. Makes Philips-Model Green Perform sleek- DN295B LED 10S-PSUWH/ Panasonic-Model-PDLM3509W/Havells-ZIVADRRDDLR9WLED/ Wipro-LD06-111-XXX-HE
Supplying and fixing suitable size GI box with modular plate and cover 12 modules in front on surface or in recess, including providng and fixing 4 nos. 3 pin 5/6 A modular socket outlet and 4 nos. 5/6 A modular switch with necessary connections etc. as required. (For computer plugs to be used in non residential buildings).
Supplying and fixing of Surface/recess mounting 8 way TP &N vertical load line distribution board double door steel, dust protected, duly powder coating inclusive of tinned copper bus bars,160Amp (W/o MCCB) and outgoing MCB's (Without MCB's) complete in with all petty material and labour required. Makes Havels/ABB/L&T/Schnieder
Supplying and fixing of Surface/recess mounting 4 way TP &N vertical load line distribution board double door steel, dust protected, duly powder coating inclusive of tinned copper bus bars,160 amp neutral link earth bar with provision of in commer MCCB (W/o MCCB) and outgoing MCB's (Without MCB's) complete in with all petty material and labour required. Makes Havels/ABB/L&T/Schnieder
Dismantelling of existing LAN cable and relaying in existing PVC conduit pipe complete in all respect.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 4 sq. mm
a. Copper bus bar of rating equal or higher than the incomer current rating.
b. Provision for incomer MCCB 250 amp, 4 pole 36KA breaking capacity =one
c .Provision for outgoing TP MCCB's upto 125 amp=7 nos
c .Provision for outgoing MCBTPNBDB4 Way Each = 2 Nos
d .Cable alley on both sides Make - 01 set
Supply and erection of exhaust fan metalic body, Size 450mm sweep 900 RPM complete in all respect with necessary connections. The job includes Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Makes:- Havells- turbo force SP/crompton- EXHD 450-6-1/Bajaj-Supreme Plus.
Supply and erection of National make louver shutter with aluminium wings for exhaust fan of size 450mm on exisiting hole complete with petty material and labour requierd to complete the job.
Supply and fixing of 63 amp rating, TPN MCB 415V, 10KA"C" curve miniature circuit breaker suitable for inductive load of following poles in the existing DB complete with connections, testing and commissioning as required.Makes Havels/ABB/L&T/Schnieder
Supply and fixing of TPMCB 63 amp rating, 415V, 10KA"C" curve miniature circuit breaker suitable for inductive load of following poles in the existing DB complete with connections, testing and commissioning as required.Makes Havels/ABB/L&T/Schnieder
Disconnection of existing Single/three phase , cable connections/ circuits of existing Distribution boards e & irespective of number of circuits and reconnctions in new Distributon boards conmplete in all respect to make the supp;y functional.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.65 MB
BOQ_110902.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid