Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.7 L+₹5.2 L (42.0%)Rejected-Finance H NO 89 BEHIND DD LEH UT LADAKH | LEH | LEH | LADAKH | 194101 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹18.0 L+₹5.6 L (45.0%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L3 | Rejected-Finance Being L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate cat c(i) | |
| 5 | Rejected-Technical HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | - | Rejected-Technical Not enlisted in appropriate cat c(i) |
| Sl No | Description | Qty | Unit | Top Mind Industries Pvt Limited L1 | national engineering L3 | M/S HIGHLAND ENGINEERING L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches for Soft/ dense soil n. exc 1.5 m wide and n. exc 1.5 m depth 1.5m for laying cables/poles, stays, foundation etc and getting out in any type of soil complete all as specified and directed. | 89 | Cubic Metre | 100 ₹8,900 Lowest | 190 ₹16,910 | 300 ₹26,700 |
| 2.00 | Returning filling including spreading levelling watering and well ramming in layers n.exc 25cm thick complete all as specified and directed. | 80 | Cubic Metre | 35 ₹2,800 Lowest | 120 ₹9,600 | 150 ₹12,000 |
| 3.00 | Removal of excavated material (soil) to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above from the starting point complete all as specified and directed. | 9 | Cubic Metre | 100 ₹900 | 70 ₹630 Lowest | 300 ₹2,700 |
| 4.00 | Material and labour for cleaning and removing dirt particle and decarburizing boiler of central heating plant of capacity 1 to 4 lack K cal / hrs including replacement of wear and tear gaskets, unserviceable nuts, bolts and washers and making all joints for pipes leaks proof with replacement of minor accessories of glycol / water circulating systems etc for effective function of the plant complete all as specified and directed. | 12 | Each Job | 15,000 ₹1,80,000 | 1,325 ₹15,900 Lowest | 2,500 ₹30,000 |
| 5.00 | Material and labour for cleaning/removing dirt, impurities particle from fuel tank of size 1.25 m x 1.25 m x1.25 m including replacement of defective gaskets, unserviceable nuts, bolts and washers and making all joints leaks proof using necessary accessories complete all as specified and directed. | 6 | Each Job | 5,000 ₹30,000 | 120 ₹720 Lowest | 250 ₹1,500 |
| 6.00 | T&P alongwith labour only for attending of complaint for day to day / daily complaints by employed skilled staff, checking the serviceability of fan coil unit of any capacity for having continuous serviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare part like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freeze glycol line anywhere about the premises to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engineer-in- Charge complete all as specified and directed.
Note :- i) . Attending any complaints of different nature in a single day shall be considered as one job.
ii) Any kind of replacement of major items shall be measured and paid for separately under respective item of schedule 'A' as supply and fixing in repair/replacement
iii) Any nature of complaint related with FCUs, radiators, bursting/cracking/leakage of MS pipe lines, replacement of valves etc will be completed round the clock by suitable tradesmen (welder with suitable T & P,(including portable heating materials)-01,Skilled mechanic of CHS-01, Plumber/Fitter with helper-each o1, Supervisor-01 as per desecration of Engineer-in- Charge. | 80 | Each | 790 ₹63,200 | 300 ₹24,000 Lowest | 300 ₹24,000 Lowest |
| 7.00 | Supply and fixing in replacement of sequence controller for heating plant suitable for 4 lakh Kcal for thermax plant complete all as specified and directed. | 1 | Each | 8,556 ₹8,556 Lowest | 11,355 ₹11,355 | 12,900 ₹12,900 |
| 8.00 | All as per serial item no 7 above but for 2 lakh K/cal for thermax plant -ditto-. | 1 | Each | 7,200 ₹7,200 Lowest | 8,145 ₹8,145 | 8,500 ₹8,500 |
| 9.00 | Supply and fixing in replacement of metal coupling assembly from fuel pump assly to motor suitable for 1 to 4 lakh K/ cal boiler for thermax plant complete all as specified and directed | 1 | Each | 100 ₹100 Lowest | 500 ₹500 | 250 ₹250 |
| 10.00 | Supply and fixing in replacement of water pressure gauge 0 to 5 kg/cm2 complete all as specified and directed. | 1 | Each | 500 ₹500 | 350 ₹350 Lowest | 1,500 ₹1,500 |
Tender Value
₹17.8 L
EMD Value
₹35,600
Closing Date
7 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R AND D Chandigarh
Garrison Engineer I R and D, DIHAR Base Lab, Ground Floor, Near 3 (BRD) AF Stn, Industrial Area, Ph-II, Ramdarbar, Chandigarh
REPAIR AND MAINTENANCE OF CENTRAL HEATING SYSTEM INDOOR AND OUTDOOR UNITS AT DIHAR LEH
2025_MES_719370_1
GE I R AND D/CHD-60/2025-26
Open Tender
Civil Works
Item Rate
240 days
Leh
As per tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandigarh
₹35,600
Yes
14 Oct 2025
9 Jul 2025
9 Aug 2025
9 Jul 2025
7 Aug 2025
24 Jul 2025
Amount
Excavation in trenches for Soft/ dense soil n. exc 1.5 m wide and n. exc 1.5 m depth 1.5m for laying cables/poles, stays, foundation etc and getting out in any type of soil complete all as specified and directed.
Returning filling including spreading levelling watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removal of excavated material (soil) to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above from the starting point complete all as specified and directed.
Material and labour for cleaning and removing dirt particle and decarburizing boiler of central heating plant of capacity 1 to 4 lack K cal / hrs including replacement of wear and tear gaskets, unserviceable nuts, bolts and washers and making all joints for pipes leaks proof with replacement of minor accessories of glycol / water circulating systems etc for effective function of the plant complete all as specified and directed.
Material and labour for cleaning/removing dirt, impurities particle from fuel tank of size 1.25 m x 1.25 m x1.25 m including replacement of defective gaskets, unserviceable nuts, bolts and washers and making all joints leaks proof using necessary accessories complete all as specified and directed.
T&P alongwith labour only for attending of complaint for day to day / daily complaints by employed skilled staff, checking the serviceability of fan coil unit of any capacity for having continuous serviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare part like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freeze glycol line anywhere about the premises to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engineer-in- Charge complete all as specified and directed. Note :- i) . Attending any complaints of different nature in a single day shall be considered as one job. ii) Any kind of replacement of major items shall be measured and paid for separately under respective item of schedule 'A' as supply and fixing in repair/replacement iii) Any nature of complaint related with FCUs, radiators, bursting/cracking/leakage of MS pipe lines, replacement of valves etc will be completed round the clock by suitable tradesmen (welder with suitable T & P,(including portable heating materials)-01,Skilled mechanic of CHS-01, Plumber/Fitter with helper-each o1, Supervisor-01 as per desecration of Engineer-in- Charge.
Supply and fixing in replacement of sequence controller for heating plant suitable for 4 lakh Kcal for thermax plant complete all as specified and directed.
All as per serial item no 7 above but for 2 lakh K/cal for thermax plant -ditto-.
Supply and fixing in replacement of metal coupling assembly from fuel pump assly to motor suitable for 1 to 4 lakh K/ cal boiler for thermax plant complete all as specified and directed
Supply and fixing in replacement of water pressure gauge 0 to 5 kg/cm2 complete all as specified and directed.
Supply and fixing in replacement of water pressure gauge 0 to 7 kg/cm2 complete all as specified and directed.
Supply and fixing in replacement of water pressure gauge 0 to 10 Kg/cm2 complete all as specified and directed.
Dismantling and opening the centrifugal mono block pump set 10 /15 HP capacity, stripping out the unserviceable copper winding, cleaning the slots and rewinding the same with same gauge of super enamelled copper wire in slots, using good quality of insulation paper and superior quality of varnish, oiling / greasing to the ball bearing and reassembling the same complete in all respect and fixing at installation with necessary nut, bolts, washer at exiting place including electrical connection, earthing lead connection and testing complete all as specified and directed.
All as per serial item no 13 above but 7.5 HP pump -ditto-.
All as per serial item no 13 above but 3 to 5 HP pump -ditto-.
Supply and fixing in replacement of solenoid valve for heating plant suitable for 4 lakh Kcal per hour complete all as specified and directed.
All as per serial item no 16 above but for 2 lack K cal per hour -ditto-.
All as per serial item no 16 above but for 1 lakh K cal per hour -ditto-.
Supply and fixing in replacement of flexible steel wire diesel pipe with both side coupling complete all as specified and directed.
Supply and fixing in replacement of fuel pump assembly in/out for heating plant suitable for 4Lakh Kcal per hour complete all as specified and directed.
All as per serial item no 20 above but for 2 lakh K cal per hour -ditto-.
All as per serial item no 20 above but for 1 lakh K cal per hour -ditto-.
Supply and fixing in replacement of copper pipe of size 5/8’’ complete all as specified and directed.
Supply and fixing in replacement of flair nut of size 5/8’’ complete all as specified and directed.
Supply and fixing in replacement of sight glass for AMW complete all as specified and directed. Cat part No PGAM-730014 or equivalent and approved by GE
Dismantling the existing burner assembly of heating plant of capacity 1 to 4 lakh K Cal/Hr for repair & replacement of coupling for blower & motor of burner assembly & refixing in the same position including testing complete all as specified and directed
Supply and fixing in replacement of single shaft fan motor 900 RPM, 230V suitable for 1.5 Ton FCU complete all as specified and directed.
All as per serial item no 27 above but for 2 Ton -ditto-
Supply and fixing in replacement of double shaft fan motor 900 RPM, 230V suitable for 1.5 Ton FCU complete all as specified and directed.
Supply and fixing in replacement of high voltage transformer suitable for heating plant for 1 lakh Kcal per hour for suitable Thermax plant complete all as specified and directed
All as per serial item no 32 above but for 2/4 lakh Kcal -ditto-.
Supply and fixing in replacement of ball cock valve heavy duty made out of gun metal of size 20mm x 5/8” complete all as specified and directed.
Supply and fixing in replacement of stainer Y type of size 20 mm dia complete with all fittings complete all as specified and directed.
Supply and fixing in replacement of MS nipple heavy duty 20mm bore 6” long complete all as specified and directed.
All as per serial item no 34 but 25mm bore 6" long -ditto-.
Supply and fixing in replacement of coupling 1.5/2 Ton FCU complete all as specified and directed.
Supply and fixing in replacement of bush suitable for 1.5/ 2 Ton FCU complete all as specified and directed.
Supply and fixing in replacement of Shaft suitable for 1.5/ 2 Ton FCU complete all as specified and directed.
Supply and fixing in replacement of hydraulic valve suitable for 1 to 2 lakh K cal boiler complete all as specified and directed.
Supply and fixing in replacement of hydraulic valve suitable for 4 lakh K cal boiler complete all as specified and directed.
Supply only fuel filter 1 ltrs capacity including filter complete all as specified and directed. ( Note :- Fuel filter shall be replaced after 250 hrs ).
Supply and fixing in replacement of burner assembly suitable for 1 lakh/2 lakh K cal boiler complete all as specified and directed.
Supply and fixing in replacement of burner assembly suitable for 4 lakh K cal boiler complete all as specified and directed.
Supply and fixing in replacment of M S Pipes C class with all fittings laid in floors or fixed to walls and ceilings etc including welding work and making good disturbed surface of size 80 mm dia pipe complete all as specified and directed.
All as per serial item no 50 above but 50 mm dia pipe -ditto-
All as per serial item no 50 above but 40 mm dia pipe -ditto-
All as per serial item no 50 above but 32 mm dia pipe -ditto-
All as per serial item no 50 above but 25 mm dia pipe -ditto-
All as per serial item no 50 above but 20 mm dia pipe -ditto-
Supply and fixing for insulation of MS pipe with PUF slab 40 mm thick with and including applying bituminous compound and aluminium cladding with 26 SWG aluminium sheet of size 80 mm dia pipe complete all as specified and directed.
Supply and fixing for insulation of MS pipe with PUF slab 30 mm thick with and including applying bituminous compound and aluminium cladding with 26 SWG aluminium sheet of size 50 mm dia pipe complete all as specified and directed.
All as per serial item no 57 above but 40 mm dia pipe -ditto-
All as per serial item no 57 above but 32 mm dia pipe pipe -ditto-
All as per serial item no 57 above but25 mm dia pipe pipe -ditto-
All as per serial item no 57 above but 20 mm dia pipe pipe -ditto-
Supply and fixing in replacement of contactor ML 1.5, 25 amps, 220 volt including testing etc complete all as specified and directed.
Supply and fixing in replacement of relay 6 to 09 amps, 3 phase 50HZ 415 volts complete all as specified and directed.
All as per serial item no 63 above but 10 to 16 amps -ditto-.
Supply and fixing in replacement of DTC for 1 lakh K cal boiler complete all as specified and directed.
Supply and fixing in replacement of DTC for 2 lakh K cal boiler complete all as specified and directed.
Supply and fixing in replacement of DTC for 4 lakh K cal boiler complete all as specified and directed.
Supply and fixing in replacement of Thermo couple sensor suitable for 1/2/4 lakh K cal boiler complete all as specified and directed.
Supply and fixing in replacement of LED Indicator R/Y/B suitable for suitable for 1/2/4 lakh K cal boiler panel complete all as specified and directed.
Supply and fixing in replacement of trans rod suitable for suitable for 1/2 lakh K cal boiler burner assembly complete all as specified and directed.
Supply and fixing in replacement of trans rod suitable for suitable for 4 lakh K cal boiler burner assembly complete all as specified and directed.
Supply and fixing in replacement of Main switch suitable for 1/2/4 lakh K cal boiler panel complete all as specified and directed.
Supply and fixing in replacement of soft plug top 15 Amps with indicator complete all as specified and directed.
Supply and fixing in replacement of PVC flexible copper multistrand wire 3 core of 6 sqmm as per existing, complete all as specified and directed.
Maint of electric panels after disconnecting the all connection in existing panel board complete and re-fixing the same after removing the burnt lugs/thimbles complete after checking the electrical connections and make them operational complete all as specified and directed.
Supply and fixing in replacement of digital type volt meter 0-500 volts complete all as specified and directed.
Supply and fixing in replacement of digital type amp meter complete with suitable CTs 0-300 amps complete all as specified and directed.
Supply and fixing in replacement of PVC flexible copper multistrand wire 2 core of 2.5 sqmm as per existing, complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of fan coil unit (FCU) wall mounted type drawing power 140 watt and current 0.63 Amps with 3 way electromagnetic valve of capacity of min 1.5/2 TR with accessories incl all incoming and outgoing connection with suitable size of copper pipe and electrical connection complete all as specified and directed Note: old unit shall be deposited in MES storeyard without any extra cost to the department.
M/S HIGHLAND ENGINEERING (BID ID -3377224)
national engineering (BID ID -3376987)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .