GE 881 EWS C/O 56 APO
GE 881 EWS C/O 56 APO
SPECIAL REPAIR TO BLDG NO T-119 AT UPPER GARRISON AND T-129 AT EME AND SPECIAL REPAIR TO BER PLANT AND EQUIPMENT OF WATER SUPPLY INSTALLATION AT MENDHAR UNDER GE 881 EWS
2022_MES_516409_2
GE/PNH-02/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/O 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹33,000
Yes
1 Sept 2022
9 Jun 2022
7 Jul 2022
9 Jun 2022
30 Jun 2022
16 Jun 2022
Amount
B&R PORTION:- Taking down chowkats with shutters (without taking off shutters from the frame) not exc 1.5 Sqm complete all as specified and directed.
Taking down chowkhat or frame exc 1.5 Sqm but n exc 4 Sqm each with shutters (without taking of shutter from the frames) complete all as specified and directed.
M&L for Pressed steel frames for doors for size 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate and one coat of shop coat of primer, etc, complete all as specified and directed.
M&L for 35mm thick 2nd class hardwood plain, framed, panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered paticle board medium density, wood patilcle board with commercial face veneers complete all as specified and directed.
M&L for 35mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc, (with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR part-I, section 8, clause 8.24 (a) complete all as specified and directed.
S&F GI wire cloth 0.56mm nominal dia of wire and 1.18 mm average width of aperture complete with beads etc. for door shutter/window shutter of any size/ type/thickness complete all as specified and directed.
S&F Box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick MS sheet tube factory made with single side shutters wire gauged shutter / glass glazed shutter complete with glazing bars, dovetailed or welded (wire cloth / glass panes will be measured and paid seperately) with side hung shutters with MS handles and MS peg stay dovetailed or welded incl 02 Nos, MS Tower bolts 150 mm long for each leaf including other fittings, hinges, MS handles, tarred hold fasts etc. including one coat of of red oxide zinc primer, complete all as specified and directed.
S&F sheet glass pane ordinary quality & glazing with oil putty 4mm thick not exceeding 0.50 sqm in each pane complete all as specified and directed.
S&F Solid pvc door frame of size 50mmx47mm made out of 5mm plain colour pvc sheet reinforced with ms square tube suppling and fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick(Stiles) consisting of frame made out of MS tubes for top and bottom rails. MS frames shall be covered with heat moulded plain coloured PVC,C, channel having PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame with 3 Nos stainless steel hinge 100 mm size, welded/sealed to the stiles rails with suitable PVC sheet beading and jointed together with solvent cement. S&F in the frame as per manufacturer's instructions complete all as specified and directed.
S&F Butt hinges 100 mm long, medium weight, cold rolled mild steel, complete all as specified and directed.
S&F aluminium anodised,barrel tower bolt if extruded section 150mm long complete complete all as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt 250 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy complete all as specified and directed.
S&F Aluminium, anodised, handles 150 mm of extruded section complete all as specified and directed.
S&F MS door springs 300 mm long and including roller and roller plate complete all as specified and directed.
Taking up or down 15mm bore steel tubing & connection including cleaning for or removal from site complete all as specified and directed.
S&F GI tubing medium grade 15mm dia with all fittings, cutting, threading and fixing to walls,ceiling or in floors complete all as specified and directed.
S&F in repair 15mm dia Gun-metal, globe gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F in repair 15mm bore dia Bib taps, with chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair 15 mm bore dia stop cock with chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed down both ends for iron pipes or for unions and fixed with butter fly handle complete all as specified and directed.
S&F in repair High or low level PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and connections to pipes and fixing of chain and pull, or lever, if any complete all as specified and directed.
S&F flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern complete all as specified and directed.
Taking up or down 20mm bore steel tubing & connection including cleaning for refixing complete all as specified and directed.
S&F GI tubing medium grade 20mm dia with all fittings, cutting, threading and fixing to walls,ceiling or in floors complete all as specified and directed.
S&F in repair 15mm dia brass chromium plated shower rose 125mm size complete all as specified and directed.
S&F PVC connection 600mm long 15mm dia complete all as specified and directed.
S&F in repair wash basin, Vitreous China (flat back or angle back type) of size 550 x 400mm including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed.
S&F in repair 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in floors or intrenches complete all as specified and directed.
S&F PVC floor trap with grating including jointing with solvent cement to waste pipe 75 mm dia complete all as specified and directed.
S&F in repair 75mm bore PVC soil waste and vent pipe single socketed in any length with rubber ring joints laid in trenches or floor complete all as specified and directed.
S&F in repair rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as spd in SSR Pt-I, capacity in 500 Ltrs including dismantling existing water tank and removing complete all as specified and directed.
S&F in repairs 15 mm bore, Ball brass valves, high pressure, with polythene float and fly nuts complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing unserviceable tiles and rubbish off the premises complete all as specified and directed.
M&L for 25mm thick plain cement concrete 1:2:4, type B-0 (12 mm graded aggregate) as in sub base of floor complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450 mm x 350 mm x 7mm/350x250x7mm thick as in vertical surfaces, set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:4 complete all as specified and directed. Note: Shade/Colour of tile shall be approved by the GE.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/Rectagular) area of each tile exceeding 0.11 Sqm but not exc 0.18 Sqm in floor etc, set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including cement screed bed 15 mm thick in cement mortar 1:4 base complete all as specified and directed.
S&F in repair, Vitreous china squatting pan of pattern, long pan, 'Orissa pattern', size 580 x 440 mm white with integral foot rests (excl flushing cistern and flush pipe) but including provision of lime concrete complete all as specified and directed.
M&L for chequered colour cement concrete tiles with grey cement and pigment of size 30cmx30cmx 25mm thick set jointed and pointed in neat cement slurry in floors/steps including screed bed or bedding layer of morter 15mm thick in cm 1:4 complete all as specified and directed.
Demolition of Brick work or stone/boulder masonry, built in Cement Mortar or cement lime mortar incl all quions, arches, pillars etc complete all as specified and directed.
M&L Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar in CM 1:6 complete all as specified and directed.
All as per item No. 42 above but except stone complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones & dressing of face beds and joints, with max.depression on face from straight edge held against the dressed surface n exc.20mm in lime or sand stone, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Taking down cement plaster from brick walls hacking for keys & scrubbing down with water including raking of joints etc as in patches complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on bricks surface, surface finished even & smooth without using extra cement using WPC @ 3% of cement complete all as specified and directed . Note : WPC shall be measured and paid separately
M&L 15 mm thick rendering in cement mortar 1:6 on stone masonry or other than fair faces of brick work, surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for preparation of new wall surfaces and applying two coats of cement base paint over a coat of white wash complete all as specified and directed.
M&L for preparation of new plaster surfaces of wall and applying two coats of OBD over a coat of chalk whiting primer complete all as specified and directed.
M&L for preparation of old wall plastered surface including brooming down or steel wire brushing scrapping down moulds, mass and efflorescent salts and greasy spots and applying one coat of cement base paint complete all as specified and directed.
M&L for complete removal of existing treatment on old wall surface and applying two coats of OBD over a coat of primer and including 1mm thick wall care putty complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specified provided for complete all as specified and directed.
M&L for 50mm thick PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, including filled the joints with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
S&F Anodised aluminium snap grid frame work for false ceiling of size 605 x 605mm complete all as specified and directed.
Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L for 6mm thick Non asbestos fibre cement building fixed or laid/inserted to timber/GI/Aluminium framework fixed in ceiling with screws complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall,fixed with self tapping screwed complete all as specified and directed.
S&F pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall,fixed with self tapping screwed complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe-290, Gde E-165 complete all as specified and directed.
S&F mild steel flat iron for wind ties for roof including securing bolts and necessary drilling etc complete all as specified and directed .
M&L for preparation of new or previously untreated steel or iron surfaces of any description, not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparing of new or previously untreated surfaces of wood of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for PCC in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed block, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed type B1 (1:2:4) using 20 mm graded aggregate complete all as specified and directed.
S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape requred, including cranking , bending spirally for columns hooking for columns hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No. 69 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on stone masonary surfaces or surface other than fair face of brick or on one side of lathing, surface finished even & smooth without using extra cement using WPC @ 3% of cement complete all as specified and directed . Note : WPC shall be measured and paid separately
M&L for 10 mm thick rendering in cement mortar 1:6 on fair faces of brick or concrete surfaces, surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for 50mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in path/ hard standing/ floor etc complete all as specified and directed.
E&M PORTION:- Supply and fix Voltage stabilizer for automatic operation, three phase for unbalanced load naturally oil cooled,outdoor type & designed for input variation between 210 V to 480 V (phase to phase )with output voltage stabilized at 415 with accuracy ± 1 % phase to phase 240 + 1% phase to neutral of capacity 60 KVA complete all as specified and directed. Make: Electricfield/Volina/AE
M & L for Earthing for poles and other machinery/eqpt in repair using GI strip as earth lead and MS galvanized steel earth plate electrode 600x600x 6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32x6mm with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt 15cm at round the earth plate watering pipe 20mm med grade/galvanized and 40mm dia GI pipe light grade for GI strip protectetion, funnel with wire mesh including testing on completion, complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed.
Excavation in trenches n.exc 1.5M wide and n.exc 1.50M in depth for taking up or laying of under ground cable in soft/loose soil and getting out complete all as specified and directed.
Returning, filling soil in trenches including spreading levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removal excavated soil not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Supply and laying sand river for cushioning with layers of sand 8 cm before laying of cable and 15 cm after laying of cable (total 23 cm) in trenches ,duly punning to a thickness of 18 cm complete all as specified and directed. Note: Thickness after punning shall be measured for payment
Supply and lay burnt best quality locally available bricks laid in trenches perpendicular to UG cable for cable protection complete all as specified and directed.
Supply and laying GI tubes light grade ISI marked , galvanized, 80mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable complete all as specified and directed.
Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
Point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc for one light point controlled by one way switch 6 Amp complete all as specified and as directed.
All as per item No 84 above but one fan/ exhaust point (Ceiling and exhaust) controlled by one way switch 6 Amp complete all as specified and directed.
All as per item No 84 above but one 5 pin, 6 Amp socket outlet on the same board complete all as specified and directed.
All as per item No 84 above but one 3 pin, 6 Amp socket outlet on the independent board complete all as specified and directed.
All as per srl item No 84 above but for one 6 pin socket outlet 15 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 1.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair Ceiling rose, 3 phase PVC/poly carbonate, insulated body, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch piano flush type 16 Amp single pole one way, (ISI marked), complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket multipurpose 2 in 1, 5 pin, 6 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket outlet multipurpose 2 in 1, 6 pin, 5 and 15 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Tube light fitting box type suitable for LED 20W tube rod made out of ultra bright, glass shell, glare free, wide angle, single side connection retofit LED tube with G13 lamp holders complete with hosing with all accessories pre wired and making connection with copper flexible cable of appropriate size from ceiling rose to light fitting including 20LED tube rod 4 feet long with single side connection complete all as specified and directed. Make:-Havells Cat Part No:-LHLDEFXD5L8R020 for LED tube rod & Cat Part No:-LHFXCEP1TNNW020 for batten fittings or Equivalent cat part of make as specified in PS. Note :- The LED batten and LED tube rod shall be of same make.
S&F in repair LED lamp CDL 10 watt with holder base (B22) type, complete all as specified and directed. Make of LED lamp:- Havells cat part No LHLDEUEEML8R010 or Equivalent cat part of make as specified in Appx 'A' to P.S.
S&F in repair LED street light fittings 30W made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete with hosing with all accessories pre wired with and including 40mm dia GI pipe bracket of 1.2 mtr made to shape as required fixed on wall or pole with FI clamp of required shap & 40x6mm siize, nut, bolts, washers and making connection with three core copper flexible cable of suitable size to light fitting complete all as specified and directed. Make:-Havells Cat Part No:-ENDURAPEARLSL30WLED757SASYTOPCMP or Equivalent cat part of Make specified in PS
S&F in repair Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. Make:-Havells cat part No-DHDPSHODPW08 or Equivalent cat part of make as specified in P.S.
S&F MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
Supply, laying and testing of cable in trenches/ poles XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 2 core 10 sqmm including taking down complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
M&L for house sevice bracket (hook type) complete with 3.0 m long GI pipe 40 mm dia Med. Grade, two Nos, 90 degrees, bends M.S. hook and stay or guy including taking down old unserviceable bracket all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades all as specified and directed.
M&L for Hanging of ceiling fan and connecting up including providing of cable from ceiling rose or connector to fan complete all as specified and directed.
M/S BADRI NATH GUPTA
M/S INDERPAL SINGH
Modh Hafiz Khan
ABINASHI ENTERPRISES
M/S KHAN ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .