| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC A 103 VEERA GARDEN AMBEDKAR NAGAR ALWAR 301001 RAJ | ALWAR | RAJASTHAN | 301001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.0 L+₹2.0 L (8.00%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹27.0 L+₹2.0 L (8.06%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹28.8 L+₹3.8 L (15.3%)Rejected-Finance KATTI GHATI SHIV COLONY ALWAR ALWAR RAJASTHAN 301001 | ALWAR | RAJASTHAN | 301001 | L4 | Rejected-Finance Being L4 |
Tender Value
Refer Docs
EMD Value
₹59,400
Closing Date
19 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alwar
GE Alwar
REPAIR/MAINTENANCE OF LT UG CABLES, OH LINES, SERVICE CONNECTIONS AND LIGHTENING PROTECTION SYSTEM AT ITARANA, ALWAR
2022_MES_558798_1
8108/E8
Open Tender
Civil Works
Item Rate
180 days
Alwar
As per NIT
3 documents required · 3 mandatory
₹500
Yes
GE Alwar
₹59,400
Yes
7 Jan 2023
19 Oct 2022
21 Nov 2022
19 Oct 2022
19 Nov 2022
4 Nov 2022
19 Oct 2022 - 3 Nov 2022
Amount
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 240 sqmm 3½ core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified including dismantling & taking out old unserviceable cable. Note :- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
All as per serial item No 1.00 here-in-before but of cross sectional area 150 sqmm 3½ core.
All as per serial item No 1.00 here-in-before but of cross sectional area 120 sqmm 3½ core.
All as per serial item No 1.00 here-in-before but of cross sectional area 70 sqmm 3½ core.
All as per serial item No 1.00 here-in-before but of cross sectional area 35 sqmm 3½ core.
All as per serial item No 1.00 here-in-before but of cross sectional area 25 sqmm 4 core.
All as per serial item No 1.00 here-in-before but of cross sectional area 25 sqmm 2 core.
All as per serial item No 1.00 here-in-before but of cross sectional area 16 sqmm 4 core.
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation of poles/struts, stays, laying of cables, pipes etc and getting out in soft/loose soil complete all as specified.
M&L for dry sand and punning for cushioning to under ground cable all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L for brick work with FLY ASH BRICKS (As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified.
Boring of holes under road,pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 80mm dia suitable for 0.4 mpa working pressure.
Taking down old U/S galvanized iron tubing, 40-50mm bore light grade laid in trenches/under road/drains, or fixed in poles/walls.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, or fixed to poles/walls with required size of flat iron (25mm x 3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete all as specified and directed. clamps.
All as per serial item No 16.00 here-in-before but 50mm bore.
All as per serial item No 16.00 here-in-before but 80mm bore.
S&F steel tubular swaged pole 09 meter long type 410 SP-31 with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.20 metre height from top of PCC coping/pedestal and applying two coats of aluminium paint over a coat of aluminium red oxide primer to remaining portion of pole and marking pole number and including dismantling and taking down old unserviceable pre-stressed concrete pole 09 metre long all as specified & as directed. Note :- Excavation & earthwork, PCC in foundation & coping shall be measured and paid for separately.
S&F in repair stay assembly complete with accessories as shown on electrical plate No 1 of SSR Part-I with 16 mm dia 1.80 mm long stay rod, 300mm x 300mm x 6mm thick stay plate, complete all as specified including taking out old unserviceable stay assembly complete. Note :- Loop insulator, clamp, stay wire, PCC and excavation & earth work shall be measured and paid for separately.
S&F galvanized steel stranded stay wire of size 7/3.15mm or 7/4mm for stay assembly.
Demolation of Cement concrete (unreinforced) of any description and in any position as in coping /pedestal of poles.
M&L for PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation of stay assembly & poles and similar works complete all as specified. Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate in mass concrete for pole all as directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B2 using 20 mm graded stone aggregate in coping concrete for pole all as directed by Engineer-in-Charge.
S&F cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections conforming to Grade E-165 (Fe 290) including nuts, bolts, washers, welding, bending cold or hot, drilled holes for bolts in any shape or size etc, complete, all as specified. Including Dismatling & Taking down old unserviceable cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts. Note :- Size, section and shape of steel sections shall be as directed.
S&F aluminium conductor steel reinforced (ACSR) of any size including jointing with and including aluminium binding wire 2 mm dia and stretching complete on LT poles all as specified and as directed.Including Dismatling & Taking down old unserviceable aluminium conductor steel reinforced (ACSR) from overhead lines on LT poles of any size. (Notes :-(i) The ACSR conductors shall conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also deemed to include for supply and fixing of binding wire, aluminium tapes etc which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS code.
S&F LT line polyproplene composite phase separators (bolted Type) for 2 wire conforming to IS 1445 all as directed and specified
All as per item No 28.00 but 3 wire all as directed and specified
All as per item No 28.00 but 4 wire all as directed and specified
Dismatling & taking down Pin/ shackle/loop any type insulators.
S&F Loop type insulator, vitreous porcelain, white, brown or green with dimensions 90mm x 140 mm and clearance hole 25.5mm, ISI marked complete all as specified.
S&F pin type insulator porcelain vitreous, white, brown or green for working pressure 1100 volts, 100mm height and 65mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut, complete, all as specified.
S&F shackle type insulator porcelain vitreous, white, brown or green, working pressure 1100 Volts, 90mm dia and 75mm height including galvanized mild steel straps of section 31mm x 3mm with 12mm dia insulator bolts, washers and nuts, complete, all as specified.
Restraining/tightening of existing LT over head ACSR conductor of any size upto permissible sag in between existing span including GI earth wire, clamps, cradles etc. including new 2mm dia aluminium binding wire complete all as specified. Note :- The length of each conductor shall be measured & paid for. The rate quoted shall be for one conductor.
M&L for cutting/trimming the tree branches 3 mtr adjacent to the LT OH lines/street light feeder on bothe sides and removing the the same to out side and disposing same complete all as direcetd(per span distance 30-40 mtrs)
Surface dressing n.exc. 15cm deep in soft/loose soil, leveling the uneven surfaces and removing all vegetation hedges shrubs at any Sub Stns/MRS/E&M installations to give even and neat look complete all as specified and directed.
M&L for painting to PCC LT pole 9 metre long of any size with two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.2 metre height from top of PCC coping/pedestal and applying two coats of aluminium paint over cross arms, brackets, bracings, clamps, hooks etc and marking pole numbers including preparation of old surfaces for painting complete all as specified.
M&L for painting to steel tubular LT pole 9 metre long of any size with two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.2 metre height from top of PCC coping/pedestal and applying two coats of aluminium paint to remaining portion of steel pole, over cross arms, brackets, bracings, clamps, hooks etc and marking pole numbers including preparation of old surfaces for painting complete all as specified.
S&F in repair MCCB, 4 Pole, 350 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal - adjustable Magnetic setting and making connections, including disconnecting and taking down old unserviceable MCCB, complete all as specified & directed.
S&F in repair MCCB, 4 Pole, 250 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal - adjustable Magnetic setting and making connections, including disconnecting and taking down old unserviceable MCCB, complete all as specified & directed.
S&F in repair MCCB, 4 Pole, 200 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal - adjustable Magnetic setting and making connections, including disconnecting and taking down old unserviceable MCCB, complete, all as specified & directed.
S&F in repair MCCB, 3 Pole, 250 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal - adjustable Magnetic setting and making connections, including disconnecting and taking down old unserviceable MCCB, complete all as specified & directed.
S&F in repair MCCB, 3 Pole, 200 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal - adjustable Magnetic setting and making connections, including disconnecting and taking down old unserviceable MCCB, complete all as specified & directed.
S&F in repair MCCB, 3 Pole, 160 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, Adjustable thermal-Magnetic fixed type and making connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
S&F in repair MCCB, 3 Pole, 100 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Adjustable thermal-Magnetic fixed type and making connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
S&F in repair MCCB, 3 Pole, 63 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Adjustable thermal-Magnetic fixed type and making connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
Disconnecting and taking down XLPE insulated LT electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 120-95 sqmm 3½ core from LT Pole/LT Panel and cutting the burnt portion/un-insulated portion of LT cable and making the end of LT cable suitable for re-connection incl lugs and re-connecting the LT cable on LT Pole/Lt Panel and connecting with over head conductor/Panel including taking out the suitable length of cable required for re-connection from loop including necessary excavation complete all as directed.
All as per serial item No 48.00 here-in-before but cable of size 50-25 sqmm 3½ core.
All as per serial item No 48.00 here-in-before but cable of size 16-10 sqmm 2 core.
M&L for earthing to electric equipments / panels etc with and including galvanized MS earth plate electrode of size 600mm x 600mm x 6mm thick burried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5m below ground level as shown in electrical plate No 3 of SSR Part I, the earth plate surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all sides, excavation & earth work in any type of soil and removal of surplus soil upto 50m including galvanized mild steel strip 32mm x 6mm as earth lead, welding at top of electrode and other end of strip connected to equipment body/panel/test point with two Nos nuts bolts or welding with steel structure,GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 3.00 metre above ground level fixed along equipment body/panel with and including 25x3mm FI clamps, bolts, nuts and washers, PCC chamber (1:3:6) type C1, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering, 75 mm thick RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
S&F in repair single pointed air termination aluminium rod 12mm dia 300mm long fix with earth strip by providing nut & bolts all as specified and directed.
S&F in repair test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws complete all as specified and directed
S&F in repair aluminium strip 25mm x 3.15mm complete with saddle and fixing screws etc for roof conductor and down conductor on wall etc above ground complete fitting the strip all as specified and directed
M&L welding in repairs exc 2.5cm but not exc 5cm in length, thickness of metal to be welded not exc 6mm, complete all as specified.
S&F in repair butt hinges of size 50mm, heavy weight, cold rolled mild steel, ISI marked, including necessary welding, fixed in repairs, complete all as specified.
S&F fabrication of pannel door with CRCA MS sheet 2 mm thick, including bending or turning up, mitred angles, etc. as required size, including provn of 2 Nos 65 mm Godrej (freedom) lock with 2 keys complete all as directed.
M&L for painting of APFC/LT/SL panel board of any sizes with one coats of synthetic enamel paint smoke greay including preparation of old painted surfaces by scrapping of old painted surface and maing good surface all as directed by Engineer-in-Charge.
M&L Cable jointing kit for 1.1 KV (Earthed) grade cable straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armourend aluminium conductor cable of size 25-50 sqmm.
M&L Cable jointing kit for 1.1 KV (Earthed) grade cable straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armourend aluminium conductor cable of size 70-150 sqmm.
M&L Cable jointing kit for 1.1 KV (Earthed) grade cable straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armourend aluminium conductor cable of size 185-240 sqmm.
M&L Cable jointing kit for 1.1 KV (Earthed) grade cable straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armourend aluminium conductor cable of size 300-400 sqmm.
Dismantling and taking down of old unserviceable prestressed cement concrete HT pole 11 mtr height and remove from site complete including making level of disturb area all as specified and directed by Engineer-in-charge.
S&F LED street light fitting 45 watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete. Make : Havells/HPL/Bajaj/Shakti.
All as per item ser No. 64.00 here-in-before but of cap 100 Watt.
All as per item ser No. 64.00 here-in-before but of cap 120 Watt.
Supply install testing and commissioning of LED solar street light, all in one 2pcs x 20 watt each, all in one integrated LED solar street light with solar panel, lithium ion battery, poly crystline solar panel, powder coated, IP-65,>100 lm/w 20W, Solar panel of 02pcs x 20W. Solar panel of 2pcs x 50W each. battery 2pcs x 48 AH panel power 2pcs x 50W each. Steel tubular pole of 6 mtr height, built in dusk - down sensor CCT-6000k, CRI>75, SMD LEDs, 15% dimming after 4 hours of operation, battery backup -14 to 16 hours. Make : Syska LED/Axxon/Havells.
M/S GAURI CONSTRUCTION
Shiv Enterprises
M/s Yash Electrical and Maintenance
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .