30 Oct 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Officer, Trimbak Municipal Council
Trimbak Municipal Council Trimbakeshwar
Setting Up Solid Waste Management Processing Facility Including Civil Works, Installation of Machinery and Electrical Works for Trimbak Municipal Council, TAL. TRIMBAK, DIST. NASHIK.
2025_DMA_1227081_1
E_Tender Notice for 2025-26
Open Tender
Solid Waste Management
Percentage
455 days
Trimbakeshwar
Please go through detail tender notice for more information.
8 documents required · 8 mandatory
₹3,540
₹4.9 L
Trimbak Municipal Council Trimbakeshwar
4 Nov 2025
9 Oct 2025
31 Oct 2025
9 Oct 2025
30 Oct 2025
9 Oct 2025
15 Oct 2025
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, sapling sand trees girth upto 300mm, removal of stumps of trees cut earlier and disposal of unserviceable material sand stacking of serviceable material to be use dorauctioned upto a lead of 1000 metre sincluding removal and disposal of top organic soil not exceeding 150 mm in thickness.
Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 1/259)Lift 0to1.5M
Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.(Bd-A-2/259) for 1.5 to 3 lift
Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.(Bd-A-2/259) for 3 to 4.5M lift
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)
Filling in plinth and floors / trenches with contractor's murum for bedding in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-11/263)
Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264)
Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)Spec. No. - Bd E /1 Page No. 287 and B7, Page No. 38a) In PCC M-100
Providing and laying in situ cement concrete M30 with tremix treatment for 200 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete.
Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) b) In RCC M-200
Providing and casting in situ Cement Concrete of trap/ granite / quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineerincharge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (ExclFor all types of Columnsb) In RCC M-200
Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) For Beams / Braces / Lintels b) In RCC M-200
Providing and casting in situ C.C. of tr
ap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Slabs / Landings / Vertical Walls / Waist Slabs / Steps for Staircase b) In RCC M-200
Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F17/306)c) Corrosion Resistant Steel (Fe 500)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks incement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailingout water manually,striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc.
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete.
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates, etc. as per detailed design and drawing or as directed by Engineer-incharge including cutting, fabricating, hoisting, erecting and fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd-C-8/278)
Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.)Spec.One Number: As directed by Engineer- in-charge.
Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt galvanised iron screws and bolts, lead and bitumen washers etc. complete.(Weight of 6.8 Kilogram/sq.m.).
providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 120 cm wide with teak wood planking 20 mm thick including two coats of coal-tarring the upper surface of plank etc. complete. (excluding painting to underside of plank)
Providing and fixing P.V.C. Rain water pipes of 160 mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S.13592-1992 including proper rainwater receivingrecess with P.V.C. plug,bend, necessary fittings, suchas,offsets, shoes,inluding fixing the pipe on wall using approved wooden cleats projecting 25 mm to 40 mm from face of wall af ixing with clips of approved quality and One Number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipe son C.C. or masonry blocks, including necessary scaffolding and maintenance for 3yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete.
Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
Providing and fixing M.S. grill door 24 Kilogram/Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc
Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete.
Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.
Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to out side face of wall, 100 mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete.
Providing and fixing white glazed urinal with Pressmatic auto closing valve having flow rate upto 4.0Litr / Minute of Jaquar/ Cera/ Hindware / Perry ware or equivalent make with P.V.C. waste pipe with fitting arrangement etc. complete as directed by Engineer in charge. (Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)
Providing and fixing white glazed earthen ware Wash Hand Basin of 55cm.x 40cm. size including cold water pillar tap/ cold and hot water pillar tap brackets, rubber plug s and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface,testing etc. complete.
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401--Plant Mix Method and Grading - I Material
Wet Mix Macadam -- Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. Laying By Grader/Paver.
Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate (natural sand /VSI grade finely washed crushed sand) conforming to IS:383, the size of coarse aggregate not exceeding 25mm,, cement content not to be less than 150 kg /cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 M pa at 7days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor / by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete.
Providing and fixing in position TMT FE 500, 25 mm dia dowel bars precoated with anti corrosive epoxy paint of required Dia. 60cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chair s with proper alignment by using properly designed assembly of Bulk heads lubricating half length with bituminous paint as directed etc. complete.
Providing and laying in-situ M40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (natural sand/ VSI grade finely washed crushed sand) conforming to IS383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant / non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound/ by providing cement v at a in cement Mortar1:8 @ 0.6mX0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75 mm and maintaining the same through out curing period by any other method approved by Engineer-in-charge.
Turbo ventilator 24"
Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Chajjas / Parapets / Curtain Walls /Partition Walls / Pardies b) In RCC M-200
Supply & install Geosynthetic Clay Liner (GCL) is subset within geosynthetic materials.They are rolls of fabricated thin layers of bentonite clay sandwiched between two geotextile or bonded to a geomembrane. Structural integrity is maintained by needle punching, stichin or physical bonding.The permeability of the liner is less than or equal to 1 x 10-7 cm/sec which is best replacement of traditional 900 mm clay liner with 10% bentonite powder addition.(Market Rate)
Supply & installation of Non-woven Geotextile (GT) of 350g/M2 made of Polypropylene spreading on the sand layer or Geomembrane as per the directions given by the Engineer-incharge, without damaging the Geotextile or Geomembrane. The Geotextile must be placed along the slope from top to bottom with an overlap of minimum 100mm. It should be stitched with HDPE thread. Geotextile must be anchored within anchor trench including excavation of trench and backfilling, compaction complete, at top and bottom portion.Rate to include the necessary lap for jointing, stitching, wastage complete. Measurement will be made as per finished surface area. Geotextile in the anchor trench will be taken in measurement. (Spec.- As directed by the Engineer-in-charge) (Market Rate)
Trommel Drum dia 1500mm lengh 6000 4 mm Sieve
Trommel Drum dia 1800mm lengh 8000 16mm Sieve
Trommel Drum dia 1500mm lengh 8000 35mm Sieve
10 TPD MRF Plant
Trommel Drum dia 1500mm lengh 8000 100mm Sieve
Belt Conveyor (1X10M) 4 Nos
Twin Shaft Shredder Machines
Belt Conveyor (0.8 X8M) 4 Nos
Weight Bridge 25MT
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit DSR No 1-2-2
Supplying and erecting PVC trucking (PVC casing-n-capping) of size 20 mm DSR No 1-2-6
Supplying & erecting mains with 2x4 sq.mm F.R copper PVC insulated wire DSR No 1-3-3
Supplying & erecting mains with 2x6 sq.mm F.R copper PVC insulated wire DSR No 1-3-4
Supplying & erecting mains with 2x10 sq.mm F.R copper PVC insulated wire DSR No 1-3-5
Supplying & Erecting mains with 1 X 2.5 sq mm. FR copper
Supplying & Erecting modular switch 6/10 amp DSR No 1-6-5
Supplying & modular Switch 16 amp DSR No 1-6-6
Supplying & Erecting modular 3pin6A malty Socket DSR No 1-6-10
Supplying & Erecting modular 3pin 16A malty Socket DSR No 1-6-11
Supplying and erecting modular type blanking plate one module ISI mark DSR No 1-6-24
Supplying and erecting PVC Surface 1modular switch box with plate for 1DSR No 1-6-26
Supplying and erecting PVC Surface 3modular switch box with plate for 1 DSR No 1-6-28
Supplying and erecting PVC Surface 6modular switch box with plate for 1 DSR No 1-6-30
Supplying & Erecting PVC Surface switch Box 12 modular DSR No 1-6-32
Wiring for plug on board witch socket DSR No 1-7-26
Point wiring in PVC trucking with 1.sq.mm FR & accessories DSR No 1-7-19
Supplying and erecting LED Flood Light fitting above 195W DSR No2-4-18
Supplying and erecting ready to use retrofit T8 LED 18-20 W tube.DSR No 2-8-14
Supplying and erecting Ding Dong / electronic musical type call bell DSR No 2-3-13
Supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep DSR No 2-10-2
Supplying and erecting Exhaust fan medium duty 230v AC DSR No 2-10-13
Supplying and erecting ‘B’ grade G.I.pipe /M.S.pipe down rod for fan DSR No 2-11-6
Supplying &Erecting SP.MCB 6 TO 32amp in provided db DSR No 5-3-2
Supplying, erecting & marking DPMCB 6A to 32A, C- series DSR No 5-3-7
Supplying & erecting CRCA sheet metal enclosures for DPMCB. DSR No 5-4-13
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB DSR No 5-4-9
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles),DSR No 5-4-1
Supplying and erecting Bus bar chamber triple pole with neutral DSR No 6-2-7
Supplying and erecting square shaped CRCA /die-castaluminium powder coated housing LED panel light (slimedge-lit) suitable for 30W DSR No 2-1-7
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL DSR No 7-1-31
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB DSR No 5-3-13
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU DSR No 7-2-14
Making trench in hard murum/Tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kV to 11 kV complete as per specification No. CW-EXN-CTR DSR No 16-1-4
Providing earthing with galvanized iron earth plate size 60 x 60 x0.6 cm with funnel with a wire mesh for watering and brick masonryblock C.l. cover complete with all materials, testing & recording theresults as per specification no. EA-EP DSR No 9-1-3
Providing earthing with copper earth plate size 60 x 60 x 0.315 cmwith funnel with a wire mesh for watering and brick masonry blockC.l. cover with minimum 25 kg Carbon based environment friendlyback fill Ground Enhancing compound complete with all materials,testing & recording the results as per specification no ESE -LA DSR No 9-1-6
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 240 sq. mm. aluminium conductor complete erected with glands & lugs,
on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL DSR No 7-1-38
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR AP-AC/WAC DSR No 3-2-13
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 40 litres per hour & storage capacity 80 litres partially stainless steel body As per specification no. APWCR/ WC DSR No 3-3-8
Supplying and erecting aluminium strip of required sizes used forearthing on wall and/or any other purpose with necessary aluminiumclamps fixed on wall with insulating and non-corrosive bond in anapproved manner with required joints. As per specification no. EAEP. DSR No 9-2-1
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.DSR No 7-6-16
Supplying and erecting GI earth wire of high purity of different sizesused for earthing or any other purposes on wall with necessary G.IClamps fixed on wall/cable/ conduit with screws in an approvedmanner. DSR No 9-2-5
Supplying and erecting copper strip of required size used forearthing on wall and/or any other purpose with necessary copperclamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP. DSR No 9-2-2
Making cement concrete foundation in 1:2:4 cement concrete withfoundation bolts and nuts complete. (cost of wooden box is included)(for pumps). DSR No 16-3-5
Supplying and erecting 50 x 50 x 6 mm angle iron as cornersupport 2m long fixed at the middle of the fencing frame and theother side inclined at 30 degree angle, in cement concrete foundationof 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminum paint complete. DSR No 10-6-19
Supplying and erecting expanded metal jali enclosure made from GI square mesh 15 SWG having 20/25 mm squares,properlyfixed/welded and duly painted with one coat of red oxide and twocoats of silver/enamel paint complete. (size of jali or enclosure to bespecified in the estimate.)DSR No 6-1-21
Supplying and spreading stone metal 25 mm size for 100 mm depthabove the ground level complete. DSR No 16-2-3
Providing Round bottom fire bucket of 9 Litres capacity as per IS2546 made out of 24 gauge G.I. sheet with extra handle at bottomduly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete. DSR No 10-2-24
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of30x30x4 mm angle iron with cross supports for legs, welded with 4hooks and duly painted with one coat of red lead and two coats of silver paint complete. DSR No 10-2-25
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. flat with nut & bolts routed in wall complete DSR No .13-15-1
Supplying & erecting fuse bridges with base HC type fuse links415V 300A erected on polished wooden block complete.DSR No 5-10-12
Supplying and erecting metal work in CRCA sheet withfabrication of boxes, panel boards, etc. including cutting, bending,drilling, welding, riveting, treated with anti-rust treatment and powder coated or painted with one coat of red lead paint and 2 coatsof enamel paint complete..DSR No 6-1-1
Supplying & erecting cast iron cable indicator plate buried alongwith route of cable for PVC / XLPE armoured cable as perspecification no. CB-CIP DSR No 7-8-1
Supplying & erecting HRC fuse cartridge 415V 400A complete DSR No 5-10-21
Supplying and erecting triple pole mini feeder pillar with 500V, 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A as per specification no. SW-SWR/MFP DSR No 5-2-2
Providing & erecting 3 Pole MCCB 415V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB DSR No 5-5-5
Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A DSR No 5-10-27
Supplying and erecting Bakelite fuse fitting suitable for HRC boltedtype fuse up to 100A without fuse complete. DSR No 5-10-15
Supplying & erecting D. Pstructure for 11/0.415 kV, transformer with R.S.Jpoler2 nos. of size 100mm x 116mm x 11 m long with suitable distribution box of C.R.C.A. sheet 16SWG with 4 pole MCCB 300 Amps as incomer & 6 nos.100ampskitkat/MCCB for outgoing circuits. Transformer D.P. structureincludes the A. B. switch 200 Amps, D.O. fuse set & L.A. set. 2 nos.Top channel of size 100 mmx 50 mm for erection of A.B. switch &2 nos. base channel of size 100 mm x 50 x mm for erectingtransformer. Channel of size 75 x40 mm for erecting D.O. fuse set,L.A., A.B. switch handle etc. Angle of size 50 x 50 x6 mm for erecting distribution box, transformer belt etc. as per drawing (min. 124 Kg.iron work ) with necessary clamps, nut-bolts, vee cross arm, top clip,insulators etc. complete with caution board & barbed wire. D.P.Structure shall be erected in c.c. foundation complete. DSR No 8-4-26
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 16 m raising lowering high mast).DSR No 16-3-13
Supplying and erecting integrated LED street light fitting 120W IP65 & IK08 class has per specification No FG-ODF/FLS2. DSR No 2-4-9
Supplying, erecting & terminating XLPE armoured cable 2 core 10 sq mm aluminium conductor with continuous DSR No 7-1-6
Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL DSR NO 8-2-16
Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) DSR No 16-3-4
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP DSR No 9-1-4
Supplying and erecting inline D. P. Structure for 11/0.415 kV 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 300 Amps as incomer & 6 Nos. 100 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps D.O. fuse Set & L.A. Set. 2 Nos of Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set L.A. A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps Nut-b
olts. V cross arm top clip insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete.
Supplying, installing, testing and commissioning of 3 phase 11/0.433 kV 50 Hz. 200 kVA Mineral oil immersed and naturally cooled outdoor type copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side temperature rise should not exceed 45? by thermometer in oil and 50 ? by the resistance method in winding at full load rating using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5% having 4 number of tap positions with standard accessories complete with test certificate with losses below 780 Watts at 50% load 2300 Watts at 100% load as per IS 1180 (part 1) 2014 with necessary permissions of Electrical Inspector as per specification no SS- TR-NSL.
Painting of steel tubular/ rail/ RSJ pole above 6.0m length along with street light pole brackets, clamps etc by scrapping the existing paint complete as per specification no CW -PTG/PTP.DSR 16-4-3
Painting fencing of transformer substation including all supports, iron work and doors from both sides by scraping existing paint, with one coat of red oxide & two coats of aluminium paint complete.DSR No 16-4-8
Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL DSR No 7-1-19
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HTDSR No 7-3-2
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete.DSR No 7-6-11
Supplying, erecting, testing & commisioning expanded metal jali enclosure made from GI square mesh 15 SWG having 20/25 mm squares, properly fixed/welded and duly painted with one coat of red oxide and two coats of silver/enamel paint complete. (size of jali or enclosure to be specified in the DSR No 6-1-21
Supplying and erectingporcelainpin type insulatorwithGI pin suitable for 11kV line, complete as per specification no. OH-INS/PN
Supplying and erectingG.I. stay set for poles, including loop insulators at inaccessibleheightwithanchorplate300x300x6mm., strainingscrews, G.l. stay wire7/8SWG,G.l. stayrod20mmx1.8mlengthandpole clampsdulyerectedin provided cement concrete foundation complete.
Supplying and erecting rolled steel joist (girder) pole 200 x 100 mm (25.9 kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ DSR No 8-1-15
Supplying and erecting ACSR conductor of size - 6/1-4.72 mm (Dog) complete. (394.00 kg/km) as per specification No. OH-CON/ACSR DSR No :-8-4-11
Making Cement concrete foundation in 1:2:4 cement concrete with foundationbolts and nuts complete. (cost of wooden box is included) DSR No 16-3-5
Supplying and spreading stone metal 25mm size for 100mm depth above the ground level complete. DSR No 16-2-3
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2.45m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.DSR No 10-5-19
Supplying and erecting mini feeder pillar with 415V, 200A FP MCCB as incomer and 2 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket and enclosure must be dust proof, rust proof, vermin and water resistant, having slanting top and erected on angle iron/ GI frame in provided C.C. foundation complete as per specification no. SW-MFP. DSR N o :-5-2-1
SupplyinganderectingDtypepoleclamps, fabricated from50x6mmMS flat with15mmboltsandnutsfixedtosteel tubularpoledulypaintedwithonecoatof red oxide and two coats of aluminium paint complete.
upplying and fixingMSbaseplate30x30x0.6cmsize fixed to the polebase either by welding 12mm dia fixed at position.
stage.html
html • 0.03 MB
tech_eval.pdf
cancelled_1.pdf
pdf • 0.08 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.76 MB
NIT.pdf
Tender Documents • 5.74 MB
BOQ_2117653.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .