Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-Finance | L1 | Accepted-Finance Accepted | |
| 2 | L2₹26.5 L+₹815.09 (0.03%)Accepted-Finance | L2 | Accepted-Finance Accepted |
Tender Value
Refer Docs
EMD Value
₹53,500
Closing Date
28 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintendent Engineer
UPSCIDCO Jhansi
Supply of Labour and Electrical work for balance work of Rajkiya Bhed evam Bakari Prajanan Prakshetra Bohadpura Orai
2020_SCIDC_538787_1
65/SE/ET/2020-21
Open Tender
Civil Works - Others
Item Rate
90 days
Bohadpura Orai
Please reffer the tender document
2 documents required · 2 mandatory
₹1,300
Yes
UPSCIDCO LTD
₹53,500
Yes
26 Jan 2021
18 Dec 2020
29 Dec 2020
18 Dec 2020
28 Dec 2020
18 Dec 2020
18 Dec 2020 - 28 Dec 2020
90 days
Amount
LABOUR WORK
Fixing of "P" Trap 110mm Heavy Quality
Fixing of 110mm PVC Bend 4kg Pressure
Fixing of 110mm PVC pipe 4kg Pressure
Fixing of 65mm pvc pipe 4kg Pressure
Fixing of pvc calller 110mm 4kg Pressure
Fixing of pvc calller 65mm 4kg Pressure
P/Fixing of P.V.C. Cistern approved brand
Fixing of pvc bend 65mm heavy quality
Fixing of c.p. cuppling 40mm for wash basin of Approved brand
Fixing of C.P. Pillar cock of Approved brand
Fixing of c.p. angle valve of Approved brand
Fixing of Nahani trap 65mm C. Iron ISI
Fixing 65mm C.P. Jali
Fixing 65mm P.V.C. 'T' heavy duty
Fixing G.I. Pipe 15mm ISI B Class
Fixing of PVC west pipe Heavy
Fixing of PVC west pipe 32mm heavy
Fixing of c.p. cuppling 32mm of approved brand
Fixing of water closet squatting pen (Indian type W.C. pan) with 100mm sand cast iron P or S trap. 10 liter low level white PVC flushing cistern with manually controlled device (handle level) conforming to IS:7231, with all fitting and fixtures complete including cutting and making good the walls and floors wherever required.
Fixing wash basin (Size 630x450)mm with C.I. brackets, 15mm C.P. brass piller taps 32mm C.P. brass waste of standard paltern, including painting of fittings and brackets, cutting and making good the walls wherever require.
Fixing of mirror (600x450)mm of superior glass (of approved quality) and of required shape and size with plastic mouled frame of approved make and shade with 6mm thick hard board backing.
Fixing of P.V.C. pipes 100mm 6kg/Pressore
Fixing C.P.V.C.pipes complete with fittings and clamps, including cutting and making good the walls etc. 6kg 15mmø nominal bore
Fixing brass bib cock (400 gm) of approved quality. 15mmø nominal bore
Fixing C.P. angle cock (400 gm) of approved quality.
Fixing gun metal gate valve with C.I. wheel of approved quality (Screwed end) 15mmø nominal bore
Fixing uplasticised PVC connection pipe with brass unions. (45cm length) 15mmø nominal bore
placing on terrace (at all floor levels) polyethyiene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (500 L.)
Fixing P.V.C. Cowel heavy quality
Construction of main hole (900X800) (Completion of work)
Construction of Soak pit 2.5mtr dia (Completion of work)
Construction of Septic tank 50 user (Completion of work)
Fixing 110mm P.V.C. Bend (4kg/pressor)
Fixing P.V.C. door Bend (4kg/pressor)
Fixing P.V.C. waste pipe
Making Sever line Connection 110mm dia
Fixing External G.I. pipe 50mm dia
Fixing gate Valve 50mm dia
laying of G.I. Pipe 20mmØ
laying of G.I. Pipe 32mmØ
laying of G.I. Pipe 40mmØ
laying of G.I. Pipe 50mmØ
laying of G.I. Pipe 65mmØ
Provinding/Fixing of Lighting Conduduter including earthing complete item of the work
Provinding /Fixing of Level inclicator complete item of the work
Fixing of G.M. gate valve 32mmØ
Fixing of G.M. gate valve 40mmØ
Fixing of G.M. gate valve 50mmØ
Fixing of G.M. gate valve 65mmØ
Fixing of M.S. Clamp for pipe
Painting or varnishing on iron work in small areas or new wood primerwork with two coat of ready mixed priming paint & two coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all material, labour T&P complete.
One priming coat & one coat oil bond distemper on new work including supply of all material, labour T&P etc. required for proper completion of the work. (in two coat)
One priming coat & two coat of water cement paint \Exterior paint (Apex) including supply of all material, labour T&P etc. required for proper completion of the work. (in two coat)
Fixing of glass pens 4mm thick with putty & primer i/c all labour T&P complete.
Two coat Putty work at outside+inside plaster
Fixing of Consieled PVC rain water pipe 110mm
40mm thick cement cocrete flooring 1:2:4 (1cement:2coarse sand:4 graded stone aggregate of size 12.5mm and below) by laid over concrete finished with floating coat neat cement (base concrete to be paid separately) including fixing of glass strips. (Excluding cost of glass strips)
2cm. (.3/4") (20mm) thick cement plaster in Dedo or skirting in 1:2 consisting of one part of cement and 2 part in panels, finished with 3mm. (1/8") floating coat of neat cement or cement and marble dust in redio of 5:1 including supply of all material, labour T&P etc. required for proper completion of the work. (for dedo skirting)
Provinding/ Laying 80 mm. cc. paver brick over proper base and sand custion as per Analysis
providing and fixing G.I. pipes complete with G.I. fitings including trenching and refilling etc 80 mm dia nominal bore
providing and fixing gun metal gate valve with C.I. Wheel of approved quality. 80 mm dia nominal bore
providing and fixing G.I. pipes complete with G.I. fitings including trenching and refilling etc 25 mm dia nominal bore
providing and fixing G.I. pipes complete with G.I. fitings including trenching and refilling etc 40 mm dia nominal bore
providing and fixing gun metal gate valve with C.I. Wheel of approved quality. 25 mm dia nominal bore
providing and fixing gun metal gate valve with C.I. Wheel of approved quality. 40 mm dia nominal bore
construction masonry 90X90X100cm inside,in brick work in cement mortar 1:4(1 cement: 4 coarse sand ) for stop cock, with C.I. surface box 100X100X75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone agreegate 20mm nominal size),i/c necessary excavation ,foundation concrete 1:5:10 ( 1 cement:5fine sand:10 graded stone agreegate 40 mm nominal size) and inside plastering with cemen mortar 1:3(1 cement: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement as per standard design. with common burnt clay F.P.S.(non modular) brick of class designation 7.5
construction masonry 30X30X50cm inside,in brick work in cement mortar 1:4(1 cement: 4 coarse sand ) for stop cock, with C.I. surface box 100X100X75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone agreegate 20mm nominal size),i/c necessary excavation ,foundation concrete 1:5:10 ( 1 cement:5fine sand:10 graded stone agreegate 40 mm nominal size) and inside plastering with cemen mortar 1:3(1 cement: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement as per standard design. with common burnt clay F.P.S.(non modular) brick of class designation 7.5
M.S. flange 80mm/165mm dia
Water Harwesting Chamber
Cleaning of jungle i/c uprooting………up to distance up to 50m
Excavation in foundation in black cotton soil (in Bundelkhand area) including lift upto 1.5 m. and lead upto 30 m. and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by Engineer-in-charge a distance of 30 m. from the foundation trenches.
P.Cement concrete in 1:4:8 with cement, sand and(22.40.43) 40mm granite stone ballast (crusher broken) in foundation including supply of all materials, labours and T&P etc. required for proper completion of the work . (Edging)
230 mm thick brik works in 1:6 cement sand and corse sand of 1.25 F.M. mortar upto plinth supply of all materials, labours and T&P etc. required for proper completion of the work .But in foudation in 230mm wall including providing scaffolding rope, chahlies fixing and removal.
40mm thick Cement concrete floring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate og size 12.5mm and below) by laid over cocrete finished with floting of neat cement (base concerte to be paid separetly) includind fixing of glass strips. (excluding cost of glass strips)
15mm thick plaster with cement moter over brick work minimum thickness to be less then 3/6'' (12mm) thick including supply of all marerial labour and T&P etc. requred for proper complition of work for for proper complition of the work but with cement and approved coarse sand in 1:6 cement & coarse sand of 1.25 F.M mortar. in perapet wall.
R.C.C work with cement appproved course sand and 2 cm (3/4)" gauge approved stne grit moter in over the proportion of 1:11/2:3 in having spans above 6m. Excluding supply of rainfor cement and its bending but including its fixing and bending the same with 24 B.W.G.G.I. Binding wire and including necessary centring and shuttering etc. required for proper cmpletion of work binding wirq cost being including in the item.
Miled steel or iron in plane work such as rainforcement concrete or rainfoced brick work (when not include in an over all rates) wrought to raquired shape as necessary includind bending for proper complition of the work and including supply of all steel and wastage & overlaping & hooks.
Drain and chmber for cllecting of rain water From deffernt buildings &sheds
Supply and Laying of 10" dia non- pessure NP2 class ( light duty) R.C.C. pipes with collars joited with stff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand ) i/c testing of joints etc. complete
600mmx600mm connecting & distibution chamber to receive outlet discharge and make water to flow through 10" dia home pipe at after each interval of 20 pipe length (1.80m) i.e 36mtr.
Boring of 30 cm dia piles of double under reamed of 50 cm dia of bulb and 3.5 m depth in black cotton soil with hand opreated auger machine i/c all labour and T&P etc for proper completion of work i/c labour T&P
Fixing panes of glass with equal or equivalent ISI marked quality putty brads and spring and including labour etc complete
Electric Work (Labour With Material)
Wiring point for light with 1.5 Sq. mm FR PVC insulated multistrend single core copper conductor cable in PVC conduit with 1.5 Sq. mm FR PVC insuleted multistrend copper conductor cable as earthwire drawn inside modular switch & celling rose angle/ batten holder on 3mm thick phenolic paminated backlite sheet etc.complete in all respect.
Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 Sq. mm FR PVC insulated multistrend single core copper conductor cable in PVC conduit with 1.5 Sqmm FR PVC insuleted multistrend copper conductor cable as earthwire drawn inside modular switch & celling rose angle/batten holder on 3mm thick phenotic paminated backlite sheet etc. complete in all respect.
Wiring point for plug with 1.5 Sq. mm FRPVC insulated multistrend single core copper conductor cable in PVC conduit with 1.5 Sq. mm FR PVC insuleted multistrend copper conductor cable as earthwire drawn inside modular switch & socket etc. complete in all respect.
S/W of submain with two number 1.5 sqmm pvc insulated Multi stand Copper Conductor Cable in 20 mm Dia Heavy Duty Condute with 1 no 1.5 SQmm FR PVC Insulated multistand Copper Conductor Cable inside the condute complete in all Respect
S/W of submain with two number 2.5 sqmm pvc insulated Multi stand Copper Conductor Cable in 20 mm Dia Heavy Duty Condute with 1 no 1.5 SQmm FR PVC Insulated multistand Copper Conductor Cable inside the condute complete in all Respect
Supply & wiring of submains with two number 6.0 sq.mm PVC insulated single core copper conductor in 25 mm dia heavy duty PVC conduit with 1 no. 4.0 sq.mm FR PVC insulated multistrend single core copper conductor cable as earth continulty wire drawn inside the conduit complete in all respect.
S/F of 16 gauge M.S Drum duly painted includidng Making hole in the wall for exhaust fan and finishing properly complete in all respect with luvers dully painted
Erection testing of exhaust fan on existing hole with suitable size of ragbolt, nut and washers etc. complete in all respect
S/F of hexagonal fan box with hexagonal side of approx 80mm in legnth fabricated from 16 SWG MS sheet incorporating 10 mm dia, MS round bar as per approved complete in all respect.
Supply & burying of Earthing Electrode T-19 (Hot Dip Galvanized), Length 3000mm, Outer pipe 50mm, inner pipe 25, Terminal dia 12mm, Outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip galvanization up to 100 micron filled with crystllingnce conductive mixture (CCM) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm squre C.I. frame with hinged cove & masonty housing. (From electrode terminal to switch board, cost of 25x3 G.I. strip will be extra) Make: As approved in U.P.P.W.D., & C.P.R.I. Certified.
S/L of 25mmx3mm G.I. strip from Earth Electrod to required complete.
Supply and fixing of fire extinguisher dry chemical type 4KG capacity ISI marke TAC Approved Complete.
S/L of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality.
S/F of 6Amp. To 32 amp. SPMCB (10 KA) Cat - B
S&F of 40Amp DPMCB (10KA) Cat - B
S&F of 100 Amp 4 Pole Isolator Cat- B
S&F surface/flush mounting 4 ways SPN distribution board with additional metal door with out MCB complete in all respect, as directed at site by Engineer in charge. Cat - B
S&F surface/flush mounting 8 ways SPN distribution board with additional metal door with out MCB complete in all respect, as directed at site by Engineer in charge. Cat - B
Supply and Fixing Fan Sheet of Backlight
Supply and Fixing of Ceiling Fan ISI Marked 1200mm sweep.
S/F of electronic fan regulator 120-280 V ISI marked ,on the existing switch board including making connections, required material, labour T/P etc. for proper completion of work to the satisfaction of Engineer in Charge of work.
Supply and Fixing of Heavy Duty Exhaust Fan 300mm
Supply and Fixing of LED Tube Light with Batton suitable for up to 1x22 watt LED tube light fitting including tube on surface Complete in all respect. CAT - AAA
S&F of Power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable MS box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer
s/f of LED Street light Fitting having dia cast aluminium body diffuser with driver set suitable for 75 watt to 90 watt confirming to IP 66 and above protection complete in all respect. Cat - AA
Supply and Fixing of LED Bulb 9 watt.
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 Sqmm 4 Core
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 Sqmm 2 Core
Pradeep kumar Upadhyay
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .