Loading…
Loading…
Tender Value
₹93.7 L
EMD Value
₹1.9 L
Closing Date
24 Apr 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of [V/N or 'V' whichever is less; where V = Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The Similar nature of works for this instant tender shall be "Supply, installation, testing and commissioning of any LT/HT electrical work." The tenderer should have executed the similar nature of works in Central/State Government department or PSUs of Central /State Government."
Tenderer must have to submit valid Electrical Contractor license as per Indian Electricity Rules for the respective category of works issued by Government Electrical License Board on or before the closing date of tender. Copy of the electrical contractor license should be submitted along with the tender offer, otherwise, the tender will be summarily rejected.
Experience in similar nature of work:- a) The tenderer must have successfully completed any of the following during last 07(seven) years, ending last day of month previous to the one in which tender is invited: Three similar nature of works each costing not less than the amount equal to 30% of the advertised value of the tender, or Two similar nature of works each costing not less than the amount equal to 40% of the advertised value of the tender, or One similar nature of work each costing not less than the amount equal to 60% of the advertised value of the tender. (b) (i) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. And in the case of major bridges - substructure, superstructure etc.), the tenderer must have successfully completed any of the following during last 07 (seven) years, ending the last day of the month previous to the one in which tender is invited: Three similar nature of works each costing not less than the an amount equal to 30% of the advertised value of each component of the tender, or Two similar nature of works each costing not less than the amount equal to 40% of the advertised value of each component of tender, or One similar nature of work each costing not less than the amount equal to 60 % of the advertised value of each component of the tender. Note for b(i): Separate completed works of minimum required values for each component shall also be considered for fulfillment of technical eligibility criteria. (b) (ii) In such cases, what constitutes a component in a composite work shall be clearly predefined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (iii) To evaluate the technical eligibility of the tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility shall be considered. The scope of work covered in other remaining components shall be either executed by the tenderer himself if he has work experience as mentioned in clause 7 (a) (ii) of Part-II of GCC or through subcontractor fulfilling the requirements as per clause 7 of Part-II of GCC or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfillment of technical eligibility. In case after the award of the contract or during the execution of work it becomes necessary for the contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of Part-II of GCC, with prior approval of the Chief Engineer in writing.
50 conditions · 4 needing a document upload
Whether the cost of earnest money deposited
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Payment of Earnest Money deposit (EMD) , in respect of e- tendering,should be accepted through net banking or online payment gateway only
1.At KYQ: Upgradation of KYQ station building, PF 2,3 & 4, executive lounge, concourse, circulating area, roads, internal drainage system and other ancillary works to improve passenger facilities(Electrical portion). 2.Construction of merchant room ,labor shed with drinking water facility, modular furniture for goods office /merchant room, installation of CCTV at DMR goods shed under jurisdiction of DEN/V/LMG (Electrical portion) 3.Construction of all weather good circulating area of L/no-4 with proper drainage, approach road, CCTV monitoring, High mast tower and modular furniture at JRNA goods circulating area under the jurisdiction of DEN/V/SCL(Electrical portion) ,4. provision of new parcel go-down, clock room including modernize furniture for parcel office Agartala (Electrical portion).
EL-LM-25-26-48
EL-LM-25-26-48
Open
Works - General
120 Days
Hojai, Assam
₹0
₹1.9 L
24 Apr 2026
31 Mar 2026
10 Apr 2026
196 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 32,93,219.82 | ||
| — | 10.00 | — | — | ||
| Supply, fitting, fixing, connection and commissioning of 22 Watt LED sleek round recessed mounting downlight luminaire, complete in all respects, suitable for operation on 230 Volts, 50 Hz AC supply. The luminaire shall be provided with pressure die-cast aluminium (Al e-cast) body, finished with drop-down polycarbonate (PC) diffuser to provide uniform low-glare illumination. The fitting shall be designed with optimized heat sink arrangement for effective heat dissipation and longer service life of LED components. The scope shall include recessed fixing of luminaire, connection with supply wiring through suitable connectors, testing, trial operation and successful commissioning, along with supply of all necessary accessories, hardware and consumables, as per direction of the Engineer-in-Charge at site. | — | — | — | 13,900 | |
| — | 7.00 | — | — | ||
| Supply, fixing, testing and commissioning of 8 Way TPN (Three Phase & Neutral) Vertical Distribution Board, single door type, fabricated from CRCA sheet steel, powder coated in RAL-9003 shade, suitable for operation on 415 Volts, 3-Phase, 4-wire, 50 Hz AC supply, complete in all respects. The distribution board shall conform to IS:8623 (Part-1 & 3) and IEC 61439 (Part-1 & 3), having impact protection IK-08 and ingress protection IP-43, and shall be provided with tinned copper busbars, neutral link, earth bar and proper internal wiring arrangement. The DB shall be equipped with following switchgear: 63 Amps, 4 Pole, C-curve MCB - 1 No. (Incomer) 32 Amps, DP, C- curve MCB - 4 Nos. (Outgoing feeders) 10 Amps, SP, C-curve MCB - 10 Nos. (Lighting / small load circuits) The complete TPN vertical DB shall be properly concealed / flush mounted on wall, including cutting, chiselling, making good of wall surface after installation, as per direction of the Engineer-in- Charge at site. The scope shall include termination of incoming and outgoing cables, ferruling, dressing of wiring, insulation resistance testing, functional checking of MCBs, trial operation and successful commissioning, along with supply of all necessary mounting hardware, glands, lugs, fasteners and consumables. | — | — | — | 1,92,920 | |
| — | 4.00 | — | — | ||
| Supply of materials and wiringof 16 amps plug point through concealed wiring by 4 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1sq mm single core PVC insulated unsheathed flexible copper wire and modular type16 amps controlling switch(with indicator type) and3 modular 16 Amps 6 Pin universal socket to be provided on good quality modular plateand frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed ifneeded than the concealed portion will be painted by contractor as per site colour ofthe surface.The whole work shall be executed as per direction of Engineer-in-Charge at site. | — | — | — | 1,779.56 | |
| — | 12.00 | — | — | ||
| Supply of materials and wiring of light point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch(with indicator type) to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. Make - Cable- Finolex, Havells, KEI, Polycab Casing & Capping/Conduit - Diamond, Presto Plast, Richa C/Rose & Switch - Crabtree, Anchor, Legrand. The whole work shall be executed as per direction of Engineer-in-Charge at site. | — | — | — | 5,661.84 | |
| — | 2.00 | — | — | ||
| Supply of materials and wiring of fan point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sqmm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch(with fan marking) and module type step fan regulator of 100 W to be provided on good quality modular plate and frame ofsuitable sizes and mounting box of proper sizes.(i.ethickness of mounting boxes of 3 mm and inside width of boxshould be 50 mm). All other necessary accessories i.e PVCTee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface.The whole work shall be executed as per direction of Engineer-in-Charge at site. | — | — | — | 1,003.56 | |
| — | 1.00 | — | — | ||
| Fabrication, design, supply, erection, testing and commissioning of Floor Mounted LT Main Control Panel, 12 Way, Outdoor Type MCCB Panel, suitable for operation on 415 V, 3 Phase, 4 Wire, 50 Hz AC supply, complete in all respects. The panel shall be dust proof, vermin proof and weather resistant, fabricated from 2 mm thick CRCA sheet steel, floor mounted on suitable MS channel base frame, duly chemically treated and powder coated, with provision for cable alley, gland plates, earthing studs and adequate ventilation. The panel shall be provided with electrolytic grade tinned copper busbars of 400 Amps rating, of size 50 mm x 6 mm for Phase and Neutral, properly supported on SMC/DMC insulators, complete with heat shrink sleeves and colour identification. The panel shall be equipped with following MCCBs conforming to IEC 60947-2 with Ics = 100% of Icu: 250 Amps, 4 Pole MCCB - 02 Nos., Breaking Capacity 50 kA, adjustable thermal-magnetic release 125 Amps, 4 Pole MCCB - 02 Nos., Breaking Capacity 25 kA 100 Amps, 4 Pole MCCB - 02 Nos., Breaking Capacity 25 kA 63 Amps, 4 Pole MCCB - 04 Nos., Breaking Capacity 25 kA The panel shall also include: Digital/Analog Ammeter with selector switch and CTs of suitable ratio Voltmeter with selector switch LED indicating lamps for R-Y-B phase healthy condition 6 Amps control MCB Auxiliary contacts, spreader links, terminal blocks and MCCB door interlock mechanism CT operated reverse current relay (wherever required) All internal wiring shall be carried out using FRLS PVC insulated copper control cable conforming to IS:694, neatly dressed, ferruled and terminated. The complete panel shall be factory wired, tested and inspected, and installed at site including termination of incoming/outgoing cables, earthing, functional testing and successful commissioning as per direction of Engineer-in-Charge. The panel shall be manufactured by CPRI approved panel manufacturer and necessary routine test certificates shall be submitted prior to dispatch. All materials, consumables and accessories required for proper execution and safe operation shall be deemed included in the quoted rate.Cable Alleys & Internal Wiring Separate top / bottom cable alleys shall be provided for incoming and outgoing cables. Internal interconnections shall be carried out using adequately sized PVC insulated copper cables / copper bus strips, properly dressed, ferruled and terminated with tinned copper lugs. Provision for metering module compartment shall be included with CT mounting space if required. Earthing & Safety Panel shall be provided with two independent earthing studs for connection to station earth grid. All metallic parts, doors and gland plates shall be electrically bonded to earth. Danger notice plate, phase indication and circuit labels shall be provided. Drawing, Testing & Commissioning GA drawing, schematic diagram and busbar layout shall be submitted and approved by the competent authority prior to fabrication. Factory routine tests and site tests shall include: Insulation Resistance Test High Voltage Test (as applicable) Functional testing of MCCBs Busbar tightness & continuity check Trial energisation and load observation shall be carried out in the presence of the Engineer-in-Charge. All necessary tools, consumables, connectors, fasteners and accessories for testing and commissioning shall be supplied by the contractor. | — | — | — | 3,49,540 | |
| — | 8.00 | — | — | ||
| Supply, fixing, testing and commissioning of 4 Way TPN (Three Phase & Neutral) Distribution Board, suitable for operation on 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply, complete in all respects. The DB shall be modular type comprising 4 modules incomer and 4+4+4 modules outgoing, fabricated from CRCA sheet steel enclosure, single door type, powder coated in RAL-9003 shade, conforming to IS:8623 (Part-1 & 3) and IEC:61439 (Part-1 & 3) with impact protection IK-08 and ingress protection IP-43. The DB shall be provided with tinned electrolytic grade copper busbars, neutral link, earth bar, removable gland plate and proper internal wiring arrangement. The board shall be equipped with following switchgear: 63 Amps, 4 Pole, C-curve MCB - 1 No. (Incomer) 32 Amps, DP, C-curve MCB - 4 Nos. (Outgoing feeders) The complete TPN DB shall be properly concealed / flush mounted on wall, including cutting, chiselling, making good of wall surface after installation, as per direction of the Engineer-in-Charge at site. The scope shall include termination of incoming and outgoing cables, ferruling, dressing of wiring, insulation resistance testing, functional testing of MCBs and successful commissioning, along with supply of all necessary mounting hardware, lugs, glands, fasteners and consumables. | — | — | — | 88,440 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, Decorative ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. | — | — | — | 5,460 | |
| — | 2740.00 | — | — | ||
| Supply, fitting and laying of Single Core 6 sq.mm Flame Retardant (FR) PVC insulated, industrial grade, multistrand flexible copper conductor cable, unsheathed type, suitable for voltage grade up to 1100 Volts, conforming to IS: 694 (Latest). The cable shall be laid through suitable conduit / casing-capping / cable tray / surface or concealed route as required at site, including cutting, bending, dressing, clamping, termination with suitable size copper lugs, ferruling and insulation testing, complete as per direction of the Engineer-in-Charge. | — | — | — | 2,11,939 | |
| — | 2100.00 | — | — | ||
| Laying, commissioning of LT/HT cable XLPEinsulated power cables with armoured aluminum conductors of different sizes partly along the pole andpartly through ground in cable trench.Loading, unloading & carrying of cable toactual work site by contractor own arrangement as per instruction of Engineer incharge at site. | — | — | — | 85,953 | |
| — | 750.00 | — | — | ||
| Excavation of cable trench of size 1.0 m deep x 0.5 m wide below ground level, including laying of armoured power cable, providing protective brick covering on sides and top, sand cushioning, and backfilling with excavated soil, properly compacted and dressed, complete as per direction of the Engineer-in-Charge at site. The scope shall include supply and fixing of suitable size cable glands, crimping type copper/aluminium lugs, ferruling, dressing and termination of armoured cable, along with testing for insulation resistance and continuity after laying. | — | — | — | 91,342.5 | |
| — | 2100.00 | — | — | ||
| Supply and laying of 40 mm diameter HDPE pipe having working pressure of 6 kgf/cm², suitable for partly underground and partly overground installation for protection of underground cable, complete in all respects. The HDPE pipe shall be laid in trench / on surface along required route, including cutting, jointing, alignment, fixing with clamps / supports where required, and proper routing for safe cable protection, as per direction of the Engineer-in-Charge at site. | — | — | — | 99,540 | |
| — | 3000.00 | — | — | ||
| Supply, installation, testing and commissioning of 25 mm dia uPVC Medium Duty rigid conduit pipe, suitable for wiring installation, conforming to relevant IS specifications, to be laid on surface / concealed in wall, ceiling or slab as required at different locations under SSE/P/KYQ, complete as per direction of the Engineer-in-Charge at site. The scope shall include cutting, bending, threading (if required), fixing with saddles / clamps at suitable intervals, providing junction boxes, bends, tees, couplers, inspection boxes, draw wire and all necessary accessories, complete in all respects. Work shall also include making good of damaged surfaces after concealed laying, proper alignment, continuity checking and readiness for cable/wire pulling. | — | — | — | 1,06,500 | |
| — | 10.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of 63 Amps, 4 Way Copper Busbar Box, suitable for operation on 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply, complete in all respects. The busbar box shall be fabricated from CRCA sheet steel enclosure, powder coated, dust and vermin resistant type, provided with electrolytic grade tinned copper busbars of suitable rating for Phase and Neutral, mounted on SMC/DMC insulated supports, along with neutral link, earth bar, removable gland plate and adequate cable entry arrangement. The scope shall include mounting on wall / structure, termination of incoming and outgoing cables with suitable size glands and lugs, ferruling, dressing of wiring, insulation resistance testing and successful commissioning as per direction of the Engineer-in-Charge at site. | — | — | — | 96,750 | |
| — | 2.00 | — | — | ||
| Supply of 9.0 metre long Galvanized Steel Tubular Pole, Type 410 SP-33, fabricated from mild steel tubular sections of stepped construction, conforming to IS: 2713 (Latest). The pole shall be of three sectional design with step lengths 5.0 m + 2.0 m + 2.0 m, having sectional outside diameters 165.1 mm x 139.7 mm x 114.3 mm and sectional thickness 5.4 mm x 4.5 mm x 3.65 mm respectively. The pole shall be hot dip galvanized inside and outside for corrosion protection, provided with suitable size MS base plate duly welded at bottom, pole cap at top, and necessary openings for cable entry/earthing. All fabrication shall be carried out with proper welding, grinding and surface finishing, and the pole shall be supplied complete in all respects ready for erection. | — | — | — | 44,280 | |
| — | 40.00 | — | — | ||
| Supply, erection, testing and commissioning of 6.0 metre height decorative Double Arm GI Street Light Pole, suitable for outdoor installation, complete with cast aluminium double arm bracket, conforming to manufacturer's standard design. The pole shall be similar to Crompton Cat. No. HM-DECO-DA-NS or equivalent make of Philips / Bajaj / Havells, fabricated from galvanized iron with suitable corrosion protection, and provided with inspection door, base plate, foundation bolts and necessary cable entry provisions. The work shall include supply and fixing of 80 Watts LED Tear Drop Pendant type street light luminaires, complete with internal wiring, termination, earthing arrangement and mounting accessories. The scope shall also include design and construction of PCC foundation as per manufacturer's recommendation, erection of pole, alignment, grouting, connection of incoming cable, insulation resistance testing, functional testing and successful commissioning as per direction of the Engineer-in-Charge at site. | — | — | — | 17,33,603.6 | |
| — | 2.00 | — | — | ||
| Erection of 9 metre long Galvanized Tubular Pole, including digging of foundation pit with depth equal to 1/5th of the total pole length, proper placement, alignment, levelling, and grouting with PCC/earth as per site requirement.The whole work shall be executed as per direction of Engineer-in-Charge at site. | — | — | — | 930.84 | |
| — | 3.08 | — | — | ||
| Supply and erection of PCC/RCC foundation for columns, pillars, posts, struts, etc., as per structural requirement, excluding the cost of cement, shuttering, and centering. Concrete mix: 1:3:6 (M-10) - 1 part cement, 3 parts sand, 6 parts graded stone aggregate of 20 mm nominal size. Dimensions: Circular block of 30 cm diameter, with height up to pole depth below ground level (GL) + 30 cm above GL + 10 cm below base plate, including tie-muffing of foundation bolts / DP. Work includes: Excavation, preparation of base, laying and compaction of concrete, embedding base plates / foundation bolts, and finishing top surface as per alignment. Execution shall be done strictly as per Engineer-in-Charge's instructions at site. | — | — | — | 6,466.83 | |
| — | 0.64 | — | — | ||
| Supply of Ordinary portland cement grade-53 | — | — | — | 3,305.43 | |
| — | 8.00 | — | — | ||
| Supply and fixing of GI channel bracket of size 75x40x40x6 mm, 3500 mm long, clamped to the pole using GI flat 50x5 mm with 50x16 mm bolts and nuts for holding insulators, lightning arrester, and associated equipment. All necessary holes for mounting shall be drilled in the GI channel. The work shall include proper alignment, fixing, and painting of the bracket for corrosion protection. All fasteners, drilling, minor materials, and execution shall be carried out as per the direction of the Engineer-in-Charge at site. | — | — | — | 10,907.6 | |
| — | 4.00 | — | — | ||
| Supply and fixing of GI angle bracket of size 50x50x6 mm, 3300 mm long, clamped to the pole using GI flat 50x5 mm with 50x16 mm bolts and nuts for mounting insulators, lightning arrester, and associated equipment. All necessary holes for fixing shall be drilled in the GI angle. The work shall include proper alignment, fixing, and painting of the bracket for corrosion protection. All fasteners, drilling, minor materials, and execution shall be carried out as per the direction of the Engineer-in-Charge at site. | — | — | — | 3,269.6 | |
| — | 6.00 | — | — | ||
| Supply and erection of 2-pole composite polymer 11 kV pin insulator, 10 kN mechanical strength, with a minimum creepage distance of 340 mm and sectional length of 235 mm. The insulator shall be made of one-piece injection-molded high-quality polymer, directly molded onto a corrosion-resistant fiberglass rod and sealed to hot-dip galvanised carbon steel end fittings with a bead of silicone rubber. The work shall include supply and fitting of all necessary hardware and accessories for mounting, ensuring full compliance with IEC: 1109 or as per IS: 731 (1971) and IS: 2488 (Pt-II) 1974. The erection shall be carried out as per the directions of the Engineer-in-Charge at site. | — | — | — | 2,203.32 | |
| — | 6.00 | — | — | ||
| Supply and erection of 2-pole composite polymer 11 kV ball & socket type disc insulator with mechanical strength >70 kN, minimum creepage distance 320 mm, and sectional length 300 mm. The insulator shall be made of one-piece injection-molded high-quality polymer, directly molded onto a corrosion-resistant fiberglass rod and sealed to hot-dip galvanised carbon steel end fittings with a bead of silicone rubber. The work shall include supply and fitting of all necessary hardware and accessories for mounting, ensuring full compliance with IEC: 1109 or as per IS: 731 (1971) and IS: 2488 (Pt-II) 1974. Erection and installation shall be carried out as per the directions of the Engineer-in-Charge at site. | — | — | — | 3,698.94 | |
| — | 1.00 | — | — | ||
| Design, supply, fabrication, erection, testing, and commissioning of high mast lighting system including suitable RCC foundation as per manufacturer's specifications and structural design. The foundation shall be constructed with M15 grade concrete in 1:2:4 mix proportion using stone chips of maximum 20 mm size, clean sand, and OPC 53-grade cement, designed for a safe soil bearing capacity of 10 ton/m². Work shall include provision of anchor bolts, embedment sleeves, tie- muffing, and base plate arrangements for tower mounting. The high mast tower shall be erected using appropriate lifting equipment, complete with control panel enclosure, wiring of LED luminaires, cable trays, conduits, termination, earthing, and all associated electrical accessories. All works shall conform to relevant IS/IEC standards for structural and electrical components and shall be executed as per the directions of the Engineer-in-Charge at site, ensuring safe, reliable, and fully operational high mast lighting. | — | — | — | 71,612.55 | |
| — | 5.00 | — | — | ||
| Supply, fitting, and fixing of foundation bolts for tower installation, minimum 8 numbers per foundation, each bolt having a minimum diameter of 25 mm and minimum length of 750 mm, manufactured from high-strength special steel. The work shall include supply and fitting of corresponding nuts, washers, anchor plates of minimum 20 mm thickness, and templates for accurate positioning. The complete set shall be provided and installed as per manufacturer's specifications and as directed by the Engineer-in-Charge at site to ensure secure and precise mounting of the structure. | — | — | — | 12,651.65 | |
| — | 1.00 | — | — | ||
| Dismantling, shifting, and safe handling of 20-meter high mast tower, including all tower sections, luminaires, control panels, and associated accessories, followed by transportation to a new site. The work shall include removal of foundation bolts, nuts, washers, and slings, careful lowering of tower sections using suitable lifting equipment such as cranes or hydraulic jacks, and loading/unloading at the transport vehicle. All dismantled components shall be handled to prevent damage during transport. The entire work shall be executed as per the directions of the Engineer-in- Charge at site, ensuring safety, structural integrity, and proper stacking or storage at the new location. | — | — | — | 29,500 | |
| — | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-LM-25-26-48final.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .