Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.4 LAccepted-Finance | 1 | Accepted-Finance Technically qualified | |
| 2 | 2₹4.5 L+₹1.1 L (32.8%)Accepted-Finance 30 1 BHAVANI MAIN ROAD VEERAPANCHATRAM ERODE 638004 | ERODE | TAMIL NADU | 638004 | 2 | Accepted-Finance Technically qualified | |
| 3 | 3₹4.5 L+₹1.1 L (33.6%)Accepted-Finance | 3 | Accepted-Finance Technically qualified | |
| 4 | 4₹5.9 L+₹2.5 L (75.1%)Accepted-Finance | 4 | Accepted-Finance Technically qualified |
| Sl No | Description | Qty | Unit | THANGAM CONSTRUCTION L2 | CONTINENTAL CONSTRUCTION COMPANY L3 | PRANEET AND CO L4 | R.KARTHICK CIVIL CONTRACTOR L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) partition of standard section and specification and as directed by the departmental officers. | 31 | sqm | 1,46,630 ₹1,46,630 | 1,46,630 ₹1,46,630 | 2,63,500 ₹2,63,500 | 1,29,270 ₹1,29,270 Lowest |
| 2.00 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections.Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.
Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. | 12 | sqm | 1,09,560 ₹1,09,560 | 1,09,560 ₹1,09,560 | 1,02,000 ₹1,02,000 | 99,600 ₹99,600 Lowest |
| 3.00 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.20mm thick as vertical at 900mm centre with 3 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the base plate encased in the concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete | 22 | Rm | 96,800 ₹96,800 | 99,000 ₹99,000 | 1,10,000 ₹1,10,000 | 85,360 ₹85,360 Lowest |
| 4.00 | Painting the Existing wall surface using best quality of Anti fungal paint (Interior) two coat as per the Specification of the approved colour over a priming coat to given even shade, including cost of brushes and all other materials required and scaffolding charges etc., complete as directed by the departmental officers. | 50 | sqm | 26,400 ₹26,400 | 26,500 ₹26,500 | 25,000 ₹25,000 | 23,000 ₹23,000 Lowest |
| 5.00 | GST (Note: The tenderer should quote the amount towards Goods and Service tax (GST) in the appropriate columns in terms of percentage (%). If not quoted, it will be considered that the rate quoted is inclusive of GST.) | 1 | Nos | 68,290.2 ₹68,290.2 | 68,704.2 ₹68,704.2 | 90,090 ₹90,090 | 60,701 ₹60,701 Lowest |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
14 Aug 2026, 3:00 pmClosed
General Manager
THE NILGIRIS DISTCOOP MILK PRODUCERS UNION LIMITED J8 P B NO 69 COONOOR ROAD UDHAGAMANDALAM 643 001
PROVIDING UPVC PARTITION STAINLESS STEEL HAND RAILS AND INTERIOR PAINTING FOR THE CHOCOLATE FACTORY AREA AVAILABLE AT NEW DAIRY COMPLEX OOTY
2026_TCMPF_691180_1
8715/Civil/ooty/2026
Limited
Civil Works
Works
Ooty
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹5,000
Yes
24 Sept 2026
5 Aug 2026
14 Aug 2026
5 Aug 2026
14 Aug 2026
5 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) partition of standard section and specification and as directed by the departmental officers. | 31 | sqm | - | - |
| 2 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections.Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.
Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. | 12 | sqm | 65 | ₹780 |
| 3 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.20mm thick as vertical at 900mm centre with 3 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the base plate encased in the concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete | 22 | Rm | - | - |
| 4 | Painting the Existing wall surface using best quality of Anti fungal paint (Interior) two coat as per the Specification of the approved colour over a priming coat to given even shade, including cost of brushes and all other materials required and scaffolding charges etc., complete as directed by the departmental officers. | 50 | sqm | - | - |
| 5 | GST (Note: The tenderer should quote the amount towards Goods and Service tax (GST) in the appropriate columns in terms of percentage (%). If not quoted, it will be considered that the rate quoted is inclusive of GST.) | 1 | Nos | 65 | ₹65 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.99 MB
BOQ_831045.xls
BOQ • 0.32 MB
OotyCons.pdf
Tender Documents • 0.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .