Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NO 87 NEW BALAJI NAGAR ATTIPATTU CHENNAI 600 120 | CHENNAI | CHENNAI | TAMIL NADU | 600120 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹7,600
Closing Date
16 May 2023, 2:00 pmClosed
SE-ES
SUPERINTENDING ENGINEER/ ELECTRICAL SYSTEM, NCTPS-I, CHENNAI-120
NCTPS I ES Circle EM I Division S Dn II Unit I II III Annual overhauling Capital Overhauling of 6 6 KV Switchgear 6 6 KV 15 75 KV Busducts USS BMCC BVDC TVDC N E SBMCC SSS A switchgear and all its bus duct during the Annual overhaul
2023_EB_310123_1
SE ES NCTPS I WC No 174 2022 23
Open Tender
Power/Energy Projects/Products
Works
365 days
NCTPS-I
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹7,600
Yes
25 May 2023
3 May 2023
17 May 2023
3 May 2023
16 May 2023
3 May 2023
Amount
I. HT SWITCHGEAR Charges for releasing all inspection covers of bus ducts, checking of Initial IR value, thorough cleaning by applying Acetone / IPA and checking healthiness of supporting insulators & tightness checking of bus bar joints and checking of healthiness of Rubber bellows for the Incomer & Tie bus ducts of one bus (U1A,U2A & U3A 6.6KV Switchgear bus ducts)
Charges for releasing all inspection covers of bus ducts, checking of Initial IR value, thorough cleaning by applying Acetone / IPA and checking healthiness of supporting insulators & tightness checking of bus bar joints and checking of healthiness of Rubber bellows for the Incomer & Tie bus ducts of one bus (U1B, U2B and U3B 6.6KV Switchgear bus duct)
Charges for releasing all inspection covers of bus ducts, checking of Initial IR value, thorough cleaning by applying Acetone / IPA and checking healthiness of supporting insulators & tightness checking of bus bar joints and checking of healthiness of Rubber bellows for the Incomer & Tie bus ducts of one bus (C1A-U1A, C2A-U2A link bus duct & C3A-U3A tie bus duct)
Charges for releasing all inspection covers of bus ducts, checking of Initial IR value, thorough cleaning by applying Acetone / IPA and checking healthiness of supporting insulators & tightness checking of bus bar joints and checking of healthiness of Rubber bellows for the Incomer & Tie bus ducts of one bus (C1B-U1B , C2B-U2B link bus duct & C3B-U3A tie bus duct)
Charges for dismantling and assembling of all the inspection covers, checking tightness & healthiness of supporting insulators and internal cleaning of 15.75 KV bus duct of GT (15.75 KV ’R’ ‘Y’ ‘B’ bus duct of GT-I, II & III )
Cleaning of Excitation Transformer & its cooling fan & its ducts (06 Nos) (Cleaning of Excitation transformer and its cooling fan and its duct) of Unit I, II & III
Charges for cleaning and lubricating of all moving parts of HT breakers, upper and lower pole arms, vacuum bottles with Acetone / IPA. All bolts and nuts tightness checking, checking healthiness of Interrupters, closing / Tripping operations mechanically and checking of IR value for 1 No. breaker. (U1A, U2A & U3A 6.6KV Switchgear panels)
Charges for cleaning and lubricating of all moving parts of HT breakers, upper and lower pole arms, vaccum bottles with Acetone / IPA. All bolts and nuts tightness checking, checking healthiness of Interrupters, closing / Tripping operations mechanically and checking of IR value for 1 No. breaker . (U1B, U2B & U3B 6.6KV Switchgear panels)
Charges for Inspection & cleaning of Bus PT cubicle, SP cubicle and checking tightness of Bus PT & SP (Bus PT cubicle (LAVT cubicle) of Unit I, II & III
II. LT SWITCHGEAR Cleaning of all the modules, cleaning & healthiness checking of power contactor tips and replacing if necessary, terminal tightness of all components, checking & cleaning of finger contacts in breaker with IPA, healthiness of spring charging motors and the mechanisms, terminal tightness of all components of breakers and checking their operations. (USS 1A, 2A & 3A SWGR)
Cleaning of all the modules, cleaning & healthiness checking of power contactor tips and replacing if necessary, terminal tightness of all components, checking & cleaning of finger contacts in breaker with IPA, healthiness of spring charging motors and the mechanisms, terminal tightness of all components of breakers and checking their operations. (USS 1B, 2B & 3B SWGR)
Cleaning of all the modules, cleaning & healthiness checking of power contactor tips and replacing if necessary, termination tightness of all components, cleaning the breakers with IPA, healthiness of spring charging motor , termination tightness of all components and checking breaker operations and refixing the modules and breakers in the respective panels. (BMCC 1A, 1B, 2A, 2B & 3A 3B SWGR)
Cleaning of all the modules with IPA, Cleaning & healthiness checking of power contactor tips and replacing if necessary, terminal tightness of all components, and refixing the modules in the respective panels. (SBMCC – 1,2 & 3 SWGR)
Cleaning of all the modules, cleaning & healthiness checking of power contactor tips and replacing if necessary, termination tightness of all components, checking & cleaning the Isolator switches. (N/E SWGR) of Unit I, II & III
Cleaning of all the modules, Cleaning & healthiness checking of power contactor tips and replacing if necessary, termination tightness of all components, cleaning the sliding contacts with IPA and refixing the modules in the respective panels. (BVDC & TVDC(VMCC) SWGRs) Unit I, II & III
III. 6.6KV ST-1, 2 & 3 Charges for releasing and Re-fixing all inspection covers of bus- ducts, checking of Initial IR value, thorough cleaning by applying Acetone / IPA and checking healthiness of supporting insulators & tightness checking of bus bar joints and checking of healthiness of Rubber bellows for the In-comer & tie bus ducts of C1, C2 & C3 Bus. (C1 A & B incomer & Tie bus duct) (ST- I to C1A) (ST- I to C1B) (ST- 2 to C2A) (ST- 2 to C2B) (ST3 to C3A) & (ST3 to C3B) C2 A & B incomer & Tie bus duct) (C3 A & B incomer & Tie bus duct)
Charges for cleaning and lubricating of all moving parts of HT breaker upper and lower pole arms, vaccum bottles with Acetone / IPA. All bolts and nuts tightness checking, checking healthiness of Interrupters closing / Tripping operations mechanically and checking of IR value for 3 No. panel. (C1A & C1B, C2A, C2B, C3A & C3B SWGR)
Complete overhauling of LT station Bus (SSSG) for SWGR. 1)Releasing the Top covers and side covers of the bus chanber, checking IR value and releasing out all the modules (156 Nos). (for 2 No. SSSG LT bus) SSS A & SSS B
A.R.C.ENGINEERING
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .