Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-Finance | L1 | Accepted-Finance Being L1 Bidder | |
| 2 | L2₹11.6 L+₹98,710 (9.30%)Rejected-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | L2 | Rejected-Finance Not being L1 Bidder | |
| 3 | L3₹13.4 L+₹2.8 L (26.2%)Rejected-Finance | L3 | Rejected-Finance Not being L1 Bidder |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
1 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAVY LAKSHADWEEP
GE Navy Lakshadweep, Coast Guard Road, Kavaratti Island 682555.
PROVISION OF SEPARATE WATER SUPPLY WITH STORAGE TANK FOR FLUSHING CISTERN AND PROVISION OF PATHWAY LIGHTS AT MINICOY UNDER GE NAVY LAKSHADWEEP
2021_MES_465043_1
8286/E8
Open Tender
Civil Works
Works
180 days
GE NAVY LAKSHADWEEP
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Navy Lakshadweep
₹28,000
Yes
30 Sept 2021
4 Aug 2021
3 Sept 2021
4 Aug 2021
1 Sept 2021
17 Aug 2021
4 Aug 2021 - 14 Aug 2021
60 days
Amount
PROVISION OF SEPARATE WATER SUPPLY WITH STORAGE TANK FOR FLUSHING CISTERN AT MINICOY Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth and getting out in soft/loose soil for removal of old pipes/ laying of new pipes complete all as specified & directed by Enginner In Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, soft/loose soil, complete all as specified & directed by Enginner In Charge.
Removing excavated material (soil) not exc. 50 Mtr and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed by Enginner In Charge.
Supply and lay burnt clay bricks, sub class "B", Designation 75, keeping the width of the brick parallel to the length of the cable complete all as specified and as directed by Engineer In Charge.
Material and labours for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying, gently punned and stretching the cable complete all as specified and directed by Engineer in Charge. Note: (i) Punned thickness shall only be measured and paid. (ii) In case of non-availability of river sand, Ridled earth (Confirming with IS-1255) shall be used for sand cushioning after obtaining written approval from GE
Supply and laying of CPVC 40mm outer dia of pipes SDR 11 & plain CPVC SDR 11 fittings, laid in trenches or on floors/ walls, complete all as specified and as directed by Engineer in Charge.
Supply and fixing of CPVC ball valves suitable for CPVC pipes of 40mm outer dia, complete all as specified and as directed by Engineer in Charge.
Supply and fixing non-return ISI square type check valve of 40 mm dia bore, fixed to CPVC tubing, complete all as specified and as directed by Engineer in Charge.
Suply and fix open well monoblock submersible Pump set, electric driven, three phase, 415 V, 50 Hz, AC supply of capacity 3.0 HP, Head not less than 30 Mtrs, Suction X delivery 50 x 40 mm, complete all as specified and as directed by Engineer in Charge.
Supply and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cables with stranded aluminium conductor of cross sectional area 6.0 sqmm 4 core, 1100 volts grade, complete all as specified and directed by Engineer in Charge. Note: Earthwork, excavation, RFR and removal of surplus soil, river sand cushioning and bricks for cable protection shall be measured and paid seperately)
Material and labour for Construction of block masonry valve chamber of size 600 x 600 x 600 mm (Internal dimensions) with PCC foundation (1:3:6) type C2 using 40mm graded stone aggregate, 100mm thick, 100 mm wide offsets alround, 200 mm thick block masonry walls, using PCC blocks, Type C1(Using 20 mm graded aggregates), built in CM (1:4), 50mm thick PCC 1:2:4 type B-1 coping finished even and smooth, rendering 15mm thick in cement mortar 1:4, finished even and smooth without using extra cement internally complete and externally upto 150 mm below GL, 40mm thick flooring with PCC 1:2:4, type B-1 laid over 75mm thick hard core including necessary excavation earthwork in any type of soil, 6.00 mm thick MS sheet cover fixed on 25 x 25 x 4 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handles and painting to steel surfaces with two coats of epoxy paint over one coat of epoxy primer including disposal of surplus soil to a distance not exceeding 50m etc., complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with galvanised steel plate electrode 600 x 600 x6mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with top edge of earth plate at a depth 1.5 Mtr below ground level connected with galvanised steel wire 4 mm dia by means of nuts bolts and washers of galvanized iron protected by 15mm dia light grade GI tubing, funnel, wire mesh, 20mm bore GI tubing medium grade watering pipe, including concrete pit in PCC 1:3:6 type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle of suitable size, charcole and slat in alternate layers necessary excavation and earth work in soft/loose soil all as shown in Electrical plate No. 3 of SSR part-I and testing, earth lead connected to earthing test point (upto main switches, DBs) complete all as specified and directed.
Supply and laying Power/Control Copper cable, Solid/ Stranded copper conducor, XLPE , insulated, PVC extruded inner sheathed for 3 core 6.00 Sqmm submersible cable, Type ST2 sheathed, 1100 V grade as per IS-7098, for connection between pump set and DOL starter, complete all as specified and directed by Enginner in Charge.
Material and labour for providing plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in mass concrete for foundation filling of centrifugal pump sets, complete all as specified and as directed.
Supply and fix rotational moulded polythylene water storage tank of 750 Ltr (Three layered, cylinderical, vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer in Charge.
Supply and fix 25 mm Ball brass valve, high pressure, with polyethene float and flynut, screwed for iron/CPVC pipe or brass ferrule complete all as specified and directed by Engineer in Charge.
Supply and fix, gun metal globe or gate valve, with iron wheel head, 25 mm dia bore of pipe, screwed both end for iron/CPVC pipe or brass ferrule, complete all as specified and directed.
Supply and fix, gun metal globe or gate valve, with iron wheel head, 32 mm dia bore of pipe, screwed both end for iron/CPVC pipe or brass ferrule, complete all as specified and directed.
Supply and laying of CPVC 25 mm outer dia of pipes SDR 11 & plain CPVC SDR 11 fittings, laid in trenches or on floors/ walls, complete all as specified and as directed by Engineer in Charge.
Supply and laying of CPVC 20 mm outer dia of pipes SDR 11 & plain CPVC SDR 11 fittings, laid in trenches or on floors/ walls, complete all as specified and as directed by Engineer in Charge.
Cutting holes, exceeding half brick but not exceeding one brick/ block walls built in cement mortar for inserting CPVC pipe line, including hold fasts and similar work and making good to disturbed surface and dismantled portion as per existing in CM (1:3) or in cement concrete (1:2:4) Type B1 using 20 mm graded aggregates, as required at site, complete all as specified and directed by Engineer-in-Charge,
Taking up or down steel/CPVC tubing and connections upto 20 mm dia, including cleaning for refixing or removal to MES Store complete all as specified and directed by Engineer-in-Charge,
PROVISION OF PATHWAY LIGHTS AT MINICOY Supply and lay or drawn through pipe, weather proof, three core, flexible round, PVC insulated copper cables of size 2.5 Sqmm, complete all as specified and as directed by Enginner-in-Charge.
Supply and fix LED bollard garden light with LED 8 Watt lamp with opal and aluminium reflector, powder coated Aluminium Sections with IP 65/IK10 protection, including fixing on concrete foundation, complete all as specified and directed. Make: Havells Cat Part No. BAMBOOBLS8WLED830PSYMTOPC (0.6M) or equivalent in Philips/crompton/Wipro/Bajaj/GE as approved by GE) Note: PCC foundation shall be measured and paid seperately
Supply and fix, 20 mm external dia Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed by Engineer-in-Charge.
Supply and fix in pole PVC terminal boxes, 230 Volts, single phase incoming and outgoing, including 01 No. MCB SP 10 Amps, complete including lugs etc... all as specified and directed by Engineer-in-Charge.
Material and labour for providing plain cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as in mass concrete for foundation filling/ benching/coping for fixing LED bollard lights including necessary formwork required for finishing the surface fair and even, complete all as specified and as directed.
KRA Engineering and Construction
STANDARD ENGINEERING
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .