Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-Finance | ₹11.3 L | L1 | Accepted-Finance valid to be received. |
| 2 | L2₹11.5 L+₹21,460 (1.90%)Accepted-Finance | ₹11.5 L+₹21,460 (1.90%) | L2 | Accepted-Finance valid to be received. |
| Sl No | Description | Qty | Unit | Hitendra A Patel | ACCURATE INFRA |
|---|---|---|---|---|---|
| 1.00Items: | |||||
| 1.01 | Providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity ICU of 25 K.A. at 415 V having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only | 12 | Ea | 84,000 ₹84,000 Lowest | 90,000 ₹90,000 |
| 1.02 | Providing and erecting busbar chamber confirming to IS-375 fabricated from 16 G.M.S. sheet, dust & vermin proof having hinged door with rubber gasket and necessary busbar supports with COPPER busbar having current density not more than 1.6 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulation tape for phase sequence, three phase & neutral each suitable for following current capacity with necessary painting mounted on wall or pedestal frame of required size with necessary connections. (A) Suitable for 63/100 Amp. capacity | 8 | Rn.mtr | 36,000 ₹36,000 Lowest | 36,000 ₹36,000 Lowest |
| 1.03 | (C) Suitable for 300 Amp. capacity | 2 | Rn.mtr | 20,000 ₹20,000 Lowest | 20,000 ₹20,000 Lowest |
| 1.04 | Providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity/strength ICU of 50 K.A. and above at 415V. having normal current rating 250A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only | 1 | Ea | 30,000 ₹30,000 | 27,500 ₹27,500 Lowest |
| 1.05 | Supply of Approved make Iron Clad or metal clad four pole change over switch 415V. confirming to IS of following capacity (A) 200 A / 250 A | 1 | Ea | 25,000 ₹25,000 | 20,000 ₹20,000 Lowest |
| 1.06 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for (A) single phase incoming and horizontal single phase outgoing (b) sheet steel double door (IP-43) (iii)8 way | 2 | Ea | 3,000 ₹3,000 Lowest | 4,000 ₹4,000 |
| 1.07 | (B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) (b) sheet steel double door (ii)6 way | 5 | Ea | 18,500 ₹18,500 Lowest | 20,000 ₹20,000 |
| 1.08 | providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark | 72 | Ea | 9,360 ₹9,360 | 7,200 ₹7,200 Lowest |
| 1.09 | Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity (A) 6 to 32 Amp. | 4 | Ea | 1,600 ₹1,600 Lowest | 2,000 ₹2,000 |
Tender Value
₹10.9 L
EMD Value
₹21,893
Closing Date
13 Feb 2026, 2:00 pmClosed
Executive Engineer, PWD, WD-I, Daman
O/o. the Ex. Eng., P.W.D., 2nd floor Multi office complex, near Veg. Market, Moti Daman.
Regarding replacement of Mains Panel and Distribution box and other Electrification works at Court Building, Fort Area, Moti Daman.
2026_DAMAN_4614_1
137/2025-26
Open Tender
Civil Works - Others
Works
60 days
Daman District
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
The Executive Engineer, PWD, WD-I, Daman
₹21,893
23 Feb 2026
5 Feb 2026
13 Feb 2026
5 Feb 2026
13 Feb 2026
5 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Items: | |||||
| 1.01 | Providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity ICU of 25 K.A. at 415 V having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only | 12 | Ea | - | - |
| 1.02 | Providing and erecting busbar chamber confirming to IS-375 fabricated from 16 G.M.S. sheet, dust & vermin proof having hinged door with rubber gasket and necessary busbar supports with COPPER busbar having current density not more than 1.6 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulation tape for phase sequence, three phase & neutral each suitable for following current capacity with necessary painting mounted on wall or pedestal frame of required size with necessary connections. (A) Suitable for 63/100 Amp. capacity | 8 | Rn.mtr | - | - |
| 1.03 | (C) Suitable for 300 Amp. capacity | 2 | Rn.mtr | - | - |
| 1.04 | Providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity/strength ICU of 50 K.A. and above at 415V. having normal current rating 250A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only | 1 | Ea | - | - |
| 1.05 | Supply of Approved make Iron Clad or metal clad four pole change over switch 415V. confirming to IS of following capacity (A) 200 A / 250 A | 1 | Ea | - | - |
| 1.06 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for (A) single phase incoming and horizontal single phase outgoing (b) sheet steel double door (IP-43) (iii)8 way | 2 | Ea | - | - |
| 1.07 | (B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) (b) sheet steel double door (ii)6 way | 5 | Ea | - | - |
| 1.08 | providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark | 72 | Ea | - | - |
| 1.09 | Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity (A) 6 to 32 Amp. | 4 | Ea | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 25.08 MB
BOQ_4790.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .