Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC JAISALMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹8.7 L+₹63,740 (7.89%)Rejected-Finance | L2 | Rejected-Finance higher amount quoted in comparison to L1 | |
| 3 | L3₹9.3 L+₹1.2 L (15.2%)Rejected-Finance | L3 | Rejected-Finance higher amount quoted in comparison to L1 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
27 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I POKARAN
MILITARY ENGINEER SERVICES ASST GARRISON ENGINEER I POKARAN MILITARY STATION POKARAN-345021
REPAIR AND MAINT TO SEWAGE LINES, SEPTIC TANK, SOAKAGE WELL INSIDE POKARAN UNDER AGE (I) POKARAN
2023_MES_599107_1
8202/E8
Open Tender
Civil Works
Item Rate
270 days
AGE I POKARAN
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I POKARAN
₹18,000
Yes
30 May 2024
29 May 2023
29 Jun 2023
29 May 2023
27 Jun 2023
13 Jun 2023
30 May 2023 - 6 Jun 2023
Amount
Demolition of plain cement concrete (Un reinforced) in benching and surface channels,bedding etc. below or above ground level complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar as in concrete bed, haunching set in cement mortar of 150 mm Dia complete all as specified and directed.
Excavation in trenches n.exc 1.5m deep and n.exc 1.5m wide in manholes,etc. and getting out any type of Soil complete all as specified and directed.
M&L for plain cement concrete 1:4:8 Type D2 using 40mm graded aggregateas in foundation, filling in mass concrete for manholes & drains complete all as specified and directed.
M&L for plain Cement concrete 1:2:4 Type B1 using 20 mm graded aggregate as in benching and surface channel of Manholes complete all as specified and directed.
M&L for plain cement concrete 1:3:6 Type C1 using 20mm graded aggregate as in coping including form work etc complete all as specified and directed.
Demolition of stone masonry built in cement or cement lime mortar complete all as specified and directed.
M&L for squared rubble walling, Jodhpur type brought up to courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and directed.
M&L for squared rubble walling, Jodhpur type brought up to courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and directed, but except stone
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses all as specified & directed by Engineer-in-Charge.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl, forms mould, mi-tred/stopped ends etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on stone masonary sufaces including finished even and smooth using extra cement complete all as specified and directed.
M&L for reinforced concrete NP2 drain pipes 150 mm Dia pipes confirming to IS laid in trenches and jointed in CM 1:2 all as specified & directed by EIC
M&L for Concrete bed to drain pipes including packing under haunching against the sides of pipe after they are laid and tested; in cement concrete 1:4:8 type D-2 for 150mm dia pipe complete all as specified and directed.
M&L for reinforced concrete NP2 drain pipes 200 mm Dia pipes confirming to IS laid in trenches and jointed in CM 1:2 all as specified & directed by EIC
M&L for Concrete bed to drain pipes including packing under haunching against the sides of pipe after they are laid and tested; in cement concrete 1:4:8 type D-2 for 200mm dia pipe complete all as specified and directed.
M & L for cutting in to existing manhole for connectiing new drain 150 mm bore , making good to pipe & rendering cutting out existing benching for & forming branch channel in cement concrete ( 1:2:4) type B1 smooth finished & reforming benching as requierd complete all as specified and directed.
Returning filling in soil including spreading, levelling and well ramming in layers n.exc 25cm thick in layer etc all complete all as specified and directed.
Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Cleaning of manholes upto 1.00m depth by means of removing the silt, sludge, etc & baling out water complete manually or mechanically and removing the sludge to a distance outside MD land and buried in pits complete all as specified and directed by Engineer-in-Charge.
Cleaning of manholes exceeding 1.00m but not exceeding 2.00m depth by means of removing the silt, sludge, etc & baling out water complete manually or mechanically and removing the sludge to a distance outside MD land and buried in pits complete all as specified and directed by Engineer-in-Charge.
Cleaning of choked sewage lines of any bore of pipe including drains by roding and well flushing with water taking out waste materials any quantity and depositing where directed including covering the same with at least 30cm thick layer of soil all as directed by Engineer-in-Charge.
M&L for cleaning/taking out sludge/mud/silt from septic tank of 50 users capacity by manually or mechanically in foul condition including dewatering septic tank, when ever required including removing of sludge/muds/silt in a closed container vehicle to a distance outside MD land and or buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly including removing stone patti/ RCC cover slab and refixing complete all as specified and directed by Engr-in-Charge.
M&L for cleaning/taking out sludge/mud/silt from septic tank of 25 users capacity by manually or mechanically in foul condition including dewatering septic tank, when ever required including removing of sludge/muds/silt in a closed container vehicle to a distance outside MD land and or buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly including removing stone patti/ RCC cover slab and refixing complete all as specified and directed. by Engr-in-Charge.
M&L for Dewatering and desludging of foul water and Sludge from soakage wells/Septic tanks manually or mechanically in a closed vessel/container vehicle to a distance outside MD landas directed by Engineer-in-Charge. Note :- The actual volume of foul water shall be measured and paid in this item.
M&L for removal of blockage in between WC and nahani trap/WC to 1st manhole/floor trap to nahani trap etc, by flexible roding and removal the all dirt upto a distance of 100m complete all as specified and directed by Engineer-in-charge.
Dismantaling Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed.
M&L for jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted, set, jointed and grouted in lime mortar 1:3 or cement mortar 1:6 complete complete all as specified and as directed by the Engineer-in-Charge
M&L for 5cm thick Sand stone slabs in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc.n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. completecomplete all as specified and as directed by the Engineer-in-Charge
Dismantling of cast iron RCC, AC or PVC pipe jointed in CM any 100mm dia bore complete all as specified and directed.
S&F PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls complete all as specified and directed.
S&F PVC (SWR) pipes of 75 mm dia, single socket fixed to walls complete all as specified and directed.
S&F 100 bore of pipe stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm dia out let complete all as specified and directed.
S&F PVC (SWR) bends with access door of 110 mm dia, any radius complete all as specified and directed.
S&F PVC(SWR) bends with access door of 75 mm dia, any radius complete all as specified and directed.
S&F PVC (SWR) bends of 110 mm dia, any radius complete all as specified and directed.
S&F PVC (SWR) bends of 75mm dia, any radius complete all as specified and directed.
PVC (SWR) vent cowl, 100 mm dia complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Providing precast cement concrete 1:2:4 Type B1 using 20 mm graded aggregate, in cover slabs (for man holesetc.) Set in CM 1:6 complete all as specified and directed.
M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia orsecuring with clips complete all as specified and directed.
M/s Rashid Mohammed
Habib Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .