| 1 | L1₹22.5 LAccepted-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹29.8 L+₹3.9 L (14.8%)Rejected-AOC 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-AOC Being other than lowest bidder | |
| 3 | L3₹31.8 L+₹5.9 L (22.7%)Rejected-AOC 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L3 | Rejected-AOC Being other than lowest bidder | |
| 4 | L4₹33.5 L+₹7.5 L (29.0%)Rejected-AOC | L4 | Rejected-AOC Being other than lowest bidder | |
| 5 | L5₹38.0 L+₹12.0 L (46.4%)Rejected-AOC H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L5 | Rejected-AOC Being other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
30 Jun 2025, 6:00 pmClosed
Garrison Engineer (South) Patiala
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH SANGRUR ROAD PATIALA CANTT
As per tender documents
2025_MES_712020_1
GE(S)/PAT/T-11/2025-26
Open Tender
Civil Works
Item Rate
240 days
Patiala
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹70,000
Yes
31 Jul 2025
2 Jun 2025
2 Jul 2025
2 Jun 2025
30 Jun 2025
16 Jun 2025
2 Jun 2025 - 9 Jun 2025
Amount
'Notes: (i) Please refer Schedule 'A' Notes of tender documents.
Material and labour for collecting the ceiling fan 1200/1400mm sweep (any make/type/ model and taking out motor, removing all coil (burnt or alive), rewinding all the coils with suitable size of super enamelled copper wire, ISI marked including all packing material, insulating materials, varnishing, greaisng, oil, re-assembling, split pins, body/blade screws, writing MES NO. with one coat of synthetic enamel paint and testing on full speed) from E/M storeyard for necessary repair/serviceing and submit the same to E/M storeyard complete all as specified and directed.
All as per item No. 2 but exhaust fans upto and including 230/300mm sweep complete all as specified and directed.
All as per item No. 2 but exhaust fans exceeding 300mm sweep but not exceeding 480mm sweep complete all as specified and directed.
All as per item No. 2 but wall mounted fans upto and incluidng 450mm sweep complete all as specified and directed.
Material and labour in replacement for gun metal bush for ceiling fans/exhaust fans/wall mounted fans of any make/type/model/size complete all as specified and directed.
Material and labour in replacement for bearing for ceiling fans/exhaust fans/wall mounted fans/desert cooler fans of any make/type/model/size complete all as specified and directed.
Material and labour in replacement for capacitor 2.5mfd, 230 volt+5% dry type complete all as specified and directed.
Material and labour in replacement for capacitor 3.15mfd, 230 volt+5% dry type complete all as specified and directed.
Material and labour in replacement for capacitor 4.0 mfd, 230 volt+5% dry type complete all as specified and directed.
Material and labour in replacement for rubber reels, nuts, bolts, spring washer for ceiling fans complete all as specified and directed.
Taking down ceiling fans/wall fans (any size, make, type) from any position, opening for and including greasing, cleaning complete overhauling including splilt pins, body/blade screws, capacitor of suitable size, refixing to its original position including making connections with and including copper conductor twin core, PVC insulated cable of size 23/.0076, 750mm long and one run of earht wore and tapping rubber insulating complete all as specified and directed.
Taking down exhaust fans/wall fans (any size, make, type) from any position, opening for and including greasing, cleaning complete overhauling including splilt pins, body/blade screws, capacitor of suitable size, refixing to its original position including making connections with and including copper conductor twin core, PVC insulated cable of size 23/.0076, 750mm long and one run of earht wore and tapping rubber insulating complete all as specified and directed.
Material and labour in replacement for ceiling fan blade (Set of 3) of 1200mm sweep (any make/model) and colour of fan blade as per colour of ceiling fan at site, with and including nuts, washers etc complete all as specified and directed.
Material and labour in replacement for ceiling fan blade (Set of 3) of 1400mm sweep (any make/model) and colour of fan blade as per colour of ceiling fan at site, with and including nuts, washers etc complete all as specified and directed.
Labour only for turning, grinding and making good to ball bearing in proper position complete all as specified and directed.
Supply and connecting in replacement for flexible copper wire of size 1.00 mm 3 core (whire colour) complete all as specified and directed.
Supply and fix in replacement for louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make and size upto 300mm complete all as specified and directed.
Supply and fix louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make and size upto 380mm/450mm IN REPLACEMENT complete all as directed.
Material and labour in replacement PVC canopy (upper and bottom) for ceiling fan of any make and size complete all as specified and directed.
Supply and fix in replacement for factory made 60cm long MS down rod of 15mm bore, medium grade, for hanging of ceiling fans duly threaded, having necessary holes and duly painted with synthetic enamel paint complete all as specified and directed.
Material and labour for spray painting on outside body of ceiling fans including blades any size with synthetic enamel apint (white colour) including scraping old paint and writing MES NO. with black paint (Synthetic enamel paint) complete all as specified and directed.
Material and labour for spray painting on outside body of ceiling fans including blades any size with synthetic enamel apint (smoke grey colour) including scraping old paint and writing MES NO. with black paint (Synthetic enamel paint) complete all as specified and directed.
Material and labour for disconnecting and taking down desert cooler fixed at any position/location, cleaning the body internally and externally by scrapping all scales, dirt etc. and repair to desert cooler to stop any type of leakage, tightening and replaceing of screws, nuts, bolts and washers incluidng refixing to its original position complete all as specified and directed. NOTE: The unit quoted rate include the cost of providing and fixing nuts, bolts and washers as requried as mentioned above and nothing extra shall be paid to the contractor on this account.
Supply and fixng water lifting pump, 230 volt, 50C/S, single phase suitable for desert cooler complete all as specified and directed.
Supply and fixng wood wool pads of suitable size including provision of wire netting with GI wire size 1.40mm dia and 25mm mesh size for holding pads for desert cooler IN REPLACEMENT complete all as specified and directed.
Supply and fixing in replacement for high density PVC pipe of size 15mm dia suitable for desert cooler of required length complete all as specified and directed.
Material and labour for rewinding of fan motor of desert cooler with super enamelled winding copper wire of suitable size, varnishing and providing new bushes, beraings, washers etc and testing the same complete all as specified and directed.
Supply and fix in replacement for complete steel body of desert cooler of capacity 4000cm with front grill, side and back panels complete all as specified and directed. The body of the desert cooler will be fabricated as under: - (a) The tip and bottom made out of 1.25mm thick GI sheet. (b) Side panels (Set of three) made out of 1.00 mm thick GI sheet. (c) Front grill of suitable size and approved quality. (d) Necessary wiring complete.
Supply and fixing in replacement for air direction grill of suitable size with name plate made out steel complete all as specified and directed.
Supply and fixing in replacement for PVC copper wire of length 2.00 metre with 3 pin plug top, 5 Amp having single phase, neutral and earth wire of size 0.75sqmm and making necessary connections from motor to regulator/switch complete all as specified and directed.
Supply and fixing in replacement for regulator knob type switch, 3 step control of speed of desert cooler motor, 230 volt, 50 Hz complete all as specified and directed.
Supply and fixing in replacement for 6A switch for air circulation system and water lifting pumping system complete all as specified and directed.
Supply and fixing in replacement for motor holding clamps made out of steel duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixing in replacement for motor holding ring made out of metal duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixing in replacement for side and rear panes made out of steel (1.00mm thick GI Sheet) for desert cooler of standard size complete all as specified and directed.
Supply and fixing in replacement for water storage bottom body (storage capacity 40 ltr) made out of steel (1.25mm thick GI Sheet) for desert cooler of standard size complete all as specified and directed.
Supply and fixing in replacement for to desert cooler PVC fan blade of superior quality (having 3 branches) complete all as specified and directed.
Dismantling of fresh air fan of any sweep (any made and type), taking out rotor, removing coil (burnt or alive), rewinding the same with super enamelled copper wire ISI marked including all packing material, insulating material, varnishing, greasing, oiling, reassembling, split pins, body/blade shade screws and testing on full speed complete all as specified and directed.
Supply and fix ceiling fans AC single phase 230/240Volt of size 1200mm sweep, BLDC, BEE five star rated including regulator fixing the fan with all connecting accessories and making electric connections from ceiling rose etc complete all as specified and directed.
Supply and fix ceiling fans AC single phase 230/240Volt of size 1200mm sweep, BLDC, BEE five star rated with remote control including regulator fixing the fan with all connecting accessories and making electric connections from ceiling rose etc. complete all as specified and directed.
Supply and fix exhaust fans AC single phase 230/240Volt of size 300mm sweep, BEE,steel body , with louver including fixing the fan with all connecting accessories andmaking electric connections from ceiling rose etc. complete all as specified and directed.
Supply and fix fresh air fans AC single phase 230/240Volt of size 225 mm sweep, steel or PVC body as per existing BEE, with louver including fixing the fan with all connecting accessories andmaking electric connections from ceiling rose etc complete all as specified and directed.
Supply and fix Desert cooler AC single phase 230/240 Volts of air flow 4000 CuM per hour steel body with all connecting accessories complete all as specified and directed.
Supply and fix desert cooler motor (copper winding), 230 volt, 50 C/S, single phase complete all as specified and directed.
REPAIR TO GEYSER WORKS Attending of day to day complaints of geysers by draning out the water and taking down carefully from wall after unscrewing nut/bolts geyser 50/35/25 Ltr capacity and opening the same for taking out internal tank, syphon assembley etc including replacement of defective unserviceable parts, reassembling and refixing complete all as specified and directed. Note: i) Spares shall me measured and paid sepratley under respective items of Sch. ii) Penal charges of Rs 250 per day per complaint shall be imposed on contractor for not attending the complaint within 24 hrs. (iii) One Electrician and One helper will attend the complaints ( One Electrician and Two helder payment will be deemed in item rate only )
Supply only heating unit (element) 240 volt AC ISI marked of 1500 watts Circular/triangular shape rating as required at site including rubber washers complete all as specified and directed.
Supply only heating unit (element) 240 volt AC ISI marked of 1500 watts special type suitable for Bajaj / CG Geyser ( as per sample ) shape rating as required at site including rubber washers complete all as specified and directed.
Supply and replace thermostat switch suitable for 25/35/50 ltr geyser AC 230 volt adjustable range from 0-90 degree Celsius complete all as specified and directed.
Supply and replace special type thermostat switch suitable for 25/35/50 ltr geyser AC 230 volt adjustable range from 0-90 degree Celsius complete all as specified and directed.
Supply and replacement internal steel tank of geyser 25 ltr capacity complete with syphon –assembly, 1.5 kw element , rubber gasket , thermostat switch , complete all as specified and directed . Note: The tank shall be tested at site and shall be able to with stand the requisite pressure. Necessary testing equipment shall be arranged by the contractor .
Supply and replacement internal steel tank of geyser 50 ltr capacity complete with syphon –assembly, 2.0 kw element , rubber gasket , thermostat switch , complete all as specified and directed. Note: The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor .
Supply and replacement of syphon assembly made out of brass of 25 ltr capacity including necessary studs, screws and rubber gasket/washers complete all as specified and directed.
All as per Srl item No. 53 above but for 50 ltr capacity, complete all as specified and directed.
Supply and replacement outer body suitable for 25 ltr geyser made out of MS sheet factory made complete with fixing bracket matching with existing, complete all as specified and directed.
Supply and replacement outer body suitable for 50 ltr geyser made out of MS sheet factory made complete with fixing bracket matching with existing complete, all as specified and directed.
Supply and replace glass wool of 25 ltrs capacity geyser complete all as specified and directed.
All as per Srl item 57 here in before but in 50 ltrs capacity geyser complete all as specified and directed.
Supply and replace indicator lamp round/square type suitable for geyser 25/50 ltr all as per sample AC 230 Volt complete all as specified and directed.
Supply and replace PVC connection 15mm dia 60 cm long complete with brass flair nuts at both ends. ( ISI marked and suitable for hot water supply upto 100 degree celcius), complete all as specified and directed.
Supply and replace PVC connection 15mm dia 90 cm Long complete with brass flair nuts at both ends. ( ISI marked and suitable for hot water supply upto 100 degree celcius), complete all as specified and directed.
Supply and fixing anchor bolt 12mmX100mm long complete all as specified and directed (Note:- Anchor bolt shall be grouted with hammer drill only)
Supply and fixing in replacement of defective mild steel base plate cup any type with screws of suitable size as per requirement complete all as specified and directed.
Supply and fixing in replacement of 15mm stop valve CP fancy type,cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe unions and suitable, complete all as specified and directed.
Supply and fixing in replacement of 1100 Volt grade cable flexible 3 Core PVC insulated PVC sheathed with stranded copper conductor of size 2.5 sqmm, complete all as specified and directed.
Supply and fixing in replacement of CP connection brass with flair nuts, complete all as specified and directed.
Cleaning / scrapping of old paint/dust and painting of geysers of 25/35/50 litres capacity at site/ stores with two coat of super enameled painting by spray, complete all as specified and directed.
Supply and fixing in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and directed.
Supply and fixing in replacement of mild steel galvanised iron water tubing 15mm bore with screwed & socket joints, medium grade, in short lenghts, with and including all fittings such as sockets, bends, elbow, unions, tees, diminishing pieces etc, fixed to wall or ceiling or in floor complete all as specified and directed.
Supply and fixing plug top 15 Amp three pin for geysers, complete all as specified and directed.
S&F in repair Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of size 15mm dia, complete all as specified and directed.
M&L in repair for point wiring with 2.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC conduit ( ISI Marked) with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and directed. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost. ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.
REPAIR TO SOLAR WATER HEATING SYSTEM Attending of day to day Solar Water Heating System complaints taking down, opening up, reassembling, refixing and testing of Solar Water Heating System including replacement of unserviceable parts wherever required at the discretion of the Engr-in- Charge shall be carried out by the contractor for efficient functioning of Solar Water heating System. The cost of material will be measured and paid seperately for replalacement of parts complete all as specified and directed. Note: (i) Schedule of repair to Solar Water heating System is catered for attending day to day complaints of different items within the prescribed time schedule as decided on complaint slip, failure to attend the complaint within the prescribed time shall attract a penalty of Rs 250 per day per complaint. Note: All repair to Solar water heating system shall be carried out from an authorized person of the manufacturer of the system and proof there of shall be produced to the GE before undertaking repairs. Contractor is advised to visit the site to ascertain the model and manufacturer of system before quoting his rates.
Supply only solar flat plate collector having collection area not less than 2.0 sqm made out of aluminium frame and toughened glass suitable for solar panel system complete all as specified and directed.
Supply only heating element, 3 KW, ISI marked, copper sheathed, nickel plated suitable for any type, make, size of solar water geysers, complete all as specified and directed.
Repairs to existing MS framed supports to SS water tank of solar heating system of capacity 100/200/300 LPD by welding , provinding necessary MS pieces to strenghthing the frame, complete all as specified and directed.
De scaling of solar water heater complete of 100/200/300/500 LPD capacity with using suitable chemical including unsv nut bolts washer etc complete all as specified and directed.
M&L for preparing new surface of steel of any description and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
M&L for Modular Socket 6A/16A - 2/3 pin combined 2 module type all as specified and directed.
M&L for Modular switch 1 way 16A, 1 module type all as specified and directed.
Supply and fix in replacement of MCB SP up to 6-32 Amp all as specified and directed.
Supply and fix in replacement of MCB SPN 32 Amp complete all as specified and directed.
M&L for modular plug & play all-in-one PVC box encloser with protected socket 16A incl MCB SPN 20A for protection device all as specified and directed.
Arneja Builders (BID ID -3328287)
Mohinder Pal and Sons (BID ID -3328503)
Gurcharan Singh Enterprises (BID ID -3341318)
Jawandha Enterprises (BID ID -3341914)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .