Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹16.3 L+₹61,085 (3.90%)Rejected-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹16.3 L+₹62,524 (3.99%)Rejected-AOC 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹16.4 L+₹68,470 (4.37%)Rejected-AOC NO 51 TOWN HALL 3RD STREET ARAKKONAM TAMIL NADU 631 001 | ARAKKONAM | RANIPET | TAMIL NADU | 631001 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹16.4 L+₹70,715 (4.51%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
27 Jul 2022, 6:00 pmClosed
Garrison Engineer M NAS Arakkonam
Garrison Engineer M NAS Arakkonam 631006
REPAIRS TO COOLING APPLIANCES SPLIT WINDOW TYPE AC WATER COOLERS REFRIGERATORS DEEP FREEZER AND VOLTAGE STABILIZERS AND CONNECTED ITEMS AT ARAKKONAM
2022_MES_537953_1
8192E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer M NAS Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer M NAS Arakkonam
₹30,000
Yes
5 Aug 2022
14 Jul 2022
29 Jul 2022
14 Jul 2022
27 Jul 2022
22 Jul 2022
14 Jul 2022 - 20 Jul 2022
Amount
Checking and identifying complaints of window / split type ACs of any make and capacity and making it 100% functional complete all as specified and as directed Note: (a )Spares required for replacement for the functioning of the AC shall be measured and paid separately (under relevant item) as supply only. (b) Quoted rates includes labour cost for taking down old unserviceable items and fixing new one.
WINDOW TYPE AC Taking out the existing burnt/ unserviceable compressor unit from 2.0 /1.50 TR capacity of window type Airconditioner and replacing the same with factory built hermatically sealed compressor unit including necessary accessories and mounting materials and welding and carry out leak test by charging with CO2 / dry nitrogen gas and arresting leakages if any by welding work etc., evacauting the system and charging of R-22 Refrigerant gas upto recommended level after ensuring leak proof condition and testing on completion for satisfactory result complete all as specified and as directed .
Servicing of Window type AC any capacity of any make / model by taking out the ACs, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ACs complete all as specified and as directed . Note: (i) Rate quoted deemed to include labour cost for taking down, repair and replacement of spares. (ii) The spare parts required for replacement shall be measured and paid Separately as supply only under relevant items of sch here-in-after.
Supply only blower motor, single phase , 230 volts 50 Hz with capacitor and mounting materials, suitable for 2.0 ton and 1.5 ton capacity of window type ACs complete all as specified and as directed
Supply only thermostatic switch for 2.0 ton and 1.5 ton window type AC complete all as specified and as directed
Supply only Airfilter pad of suitable size and thickness for 2.0 ton /1.5 ton window type AC complete all as specified and as directed.
Supply only running capacitor for 2.0 ton /1.5 ton window type AC 35+6 MFD, 230 V AC complete all as specified and as directed.
Supply only metallic / PVC fan blade as required of existing size and type for 2.0 / 1.5 ton window type AC complete all as specified and as directed .
Supply only 4 MFD 230 V AC capacitor complete all as specified and as directed .
Supply only 6 MFD 230 V AC capacitor complete all as specified and as directed.
Supply only condenser coil suitable for 2.0 ton / 1.5 ton window type AC complete all as specified and as directed . Note for Item Nos 4 to12: Labour charges deemed to be included in the rate quoted for the item No.3 above
Material and labour for Charging of refrigerant R-22 including cost of welding leak detection and refitting the same in entire system, including replacing defective liquid strainer and capillary tube. Testing and commissioning complete to the satisfaction of Engineer-in-Charge for 2.0 TR/1.5 TR window AC complete all as specified and as directed
SPLIT TYPE Acs Taking out existing burnt/ unserviceable compressor unit from the following Air conditioner rotary / reciprocating type and replacing the same with new factory built hermatically sealed compressor unit including necessary accessories and mounting materials ,carry out leak test by charging with CO2 / dry nitrogen gas and arresting leakages if any by welding work etc., evacauting the system and charging of R-22 / R410 / R32 Refrigerant gas upto recommended level after ensuring leak proof condition and testing complete for the following Air conditioners all as specified and as directed.
1.5 TR capacity of split type Airconditioner
2.0 TR capacity of split type Airconditioner
Servicing of Split type AC 1.5/ 2 TR capacity of any make/ model by taking out the AC, Cleaning of evaporating coil, condensing coil with water and brush to remove dust including cleaning of filter, greasing/oiling of motors and checking of electric circuit for smooth functioning of AC complete including replacing damaged/unserviceable accessories/spare parts all as specified and as directed. Note: (a) Rate quoted deemed to include labour cost for taking down, repair and replacement of spares. (b) The spare parts required for replacement shall be measured and paid Separately as supply only under relevant items of sch here-in-after.
Supply only new blower motor with capacitor and mounting material single phase, 230V, 50Hz for 1.5/ 2.0 TR capacity of Split type AC complete all as specified and as directed.
Supply only Airfilter pad of suitable size and specification as per existing filter for 1.5 TR /2.0 TR capacity of Split type AC complete all as specified and as directed .
Supply only running capacitor for 1.5 / 2.0 TR split type AC, 36 + 6 MFD / 45 + 6 MFD, 230 V AC complete all as specified and as directed .
Supply only running capacitor for 1.5 TR / 2.0 TR split type AC, 50+4 MFD 230 V AC complete all as specified and as directed by.
Supply only metallic/ PVC fan blade as required of existing size and type/model for 1.5 and 2.0 TR split type AC complete all as specified and as directed .
Supply only new liquid line service valve of same size including welding of joints for 1.5 and 2.0 TR split type AC complete all as specified and as directed .
Supply only suction service valve for 1.5 and 2.0 TR split type AC complete all as specified and as directed .
Supply only PCB circuit board complete with remote control as per existing model/type for 1.5 and 2.0 TR split type AC all as specified and as directed .
Supply only 3 core PVC sheathed copper cable of size 2.5 Sqmm length 3m suitable for 1.5 TR Split type AC complete all as specified and as directed.
Supply only 5 core PVC sheathed copper cable of size 7/0.0076 (4 Sqmm) length 3m suitable for 2.0 ton Split type AC complete all as specified and as directed
Supply only standard length drain pipe suitable for 1.5 / 2.0 TR split AC complete all as specified and as directed
Supply only Blower of existing size and make for any capacity Split Air Conditioner Indoor unit including taking down the existing one complete all as specified and as directed
Supply only condensed water tray of existing size and make for split AC indoor unit including taking down the existing complete all as specified and as directed .
Supply only running capacitor 2 Mfd for fan motor including taking down the existing one complete all as specified and as directed .
Supply only condenser coil for 1.5 / 2TR split type AC complete all as specified and as directed
Supply only condenser fan motor single phase for 1.5 / 2 TR split AC complete all as specified and as directed .
Supply only Indoor evaporator coil suitable for following split AC indoor unit complete all as specified and as directed.
Indoor unit 1.5 TR
Indoor unit 2 TR
Supply only Magnetic contactor suitable for split type Air Conditioner suitable for 1.5/2 TR suitable for spit type ACs as per existing make and model or as per sample complete all as specified and as directed .
Supply only louver motor (swing motor) suitable for spit type Acs any capacity/model as per existing complete all as specified and as directed. Note for Item Nos 16 to 34: Labour charges deemed to be included in the rate quoted for the item No.15 here in before
Material and labour for Charging of refrigerant R-22/R410/R32 including leak detection,welding and refitting the same in entire system, including replacing defective liquid strainer and capillary tube for 1.5/ 2.0 TR split AC including testing complete all as specified and as directed
Material and labour for cleaning and preparation of old painted surfaces of Split type AC out door unit and apply spray painting complete with two coats of synthetic enamel paint and marking SM/ MES Nos, re-fixing the out door unit of split type AC complete all as specified and as directed .
Material and labour for marking SM / MES Nos on the split type AC Window Type AC, Water cooler, Refrigerator, etc.with synthetic enamel paint of approved make and tint with letter size/type as specified and as directed .
Taking out existing old leaked copper pipe Supply and fix new copper pipe 3/8" outer dia including insulating sleeve complete all as specified and as directed
Taking out existing old leaked copper pipe Supply and fix new copper pipe 1/4" outer dia including insulating sleeve complete all as specified and as directed
Taking out existing old leaked copper pipe Supply and fix new copper pipe 1/2" outer dia including insulating sleeve complete all as specified and as directed
Taking out existing old leaked copper pipe Supply and fix new copper pipe 5/8" outer dia including insulating sleeve complete all as specified and as directed
Taking down unserviceable overload relay,Supply and fix new overload relay of range 5 to 8 Amps complete all as specified and as directed.
Supply and fix split type AC indoor unit with remote suitable for following capacity of make/model as exists/required at site including taking down the existing damaged unserviceable one and depositing to MES complete all as specified and as directed .
Removing existing damaged fixing kit of outdoor unit of split AC with stand and Supply and fix new fixing kit with stand for split type AC complete all as specified and as directed .
Supply and fix PVC flexible pipe for condensed water as per existing size and length including taking down the existing old damaged unserviceable one complete all as specified and as directed
Taking out defective/ damaged Industrial Plug and Socket and supply and fix Industrial new Plug and Socket for AC distribution box with socket and MCB upto 25A 'C' curve, 240 V complete all as specified and as directed . Make: ABB / Schneider / Siemens / Legrand
All as per item No.46 above but AC distribution box with socket and MCB 32A 'C' curve, 240 V.
Supply and fix split type AC out door unit with all accessories suitable for following capacity of make/model as exists/required at site including taking down the existing unserviceable one and depositing to MES complete all as specified and as directed .
Dismantling and taking down carefully the existing indoor and out door units of tonnage 1.5/2 TR from the existing positions for complete servicing , cleaning , greasing & maintenance and refixing the outdoor and indoor units after servicing / maintenance with necessary copper tubing with insulation including gas charging and connecting with stabilzer etc., and testing for its proper functioning complete all as specified and as directed Note: (a) Spares required shall be measured and paid under relevant items of schedule. b) Labour charges for replacing spares/components is deemed to be included in the rate quoted for item 49
Supply and fix MCBs SP 6-32 Amp, 240V 'C' curve 10KA. including taking down the existing one all as specified and as directed . Make: ABB / Schneider / Siemens / Legrand
Supply and fix synthetic rubber tube insulation of thickness 9 mm and Internal Dismeter - 6.0 mm (1/4") for refrigerant copper piping of split AC units including taking down the existing complete all as specified and as directed.
All as per item No.51 here-in-before but internal dia 16mm (5/8").
All as per item No.51 here-in-before but internal dia 9mm (3/8").
All as per item No.51 here-in-before but internal dia13mm (1/2").
VOLTAGE STABILIZER Taking out defective PCB (Printed Circuit Board) complete with components of stabilizer and Supply and fix new PCB complete with components of 4 KVA / 5 KVA Voltage stabilizer complete all as specified and as directed
All as per item No.55 here-in-before but for capacity upto 3 KVA.
Taking out defective / burnt auto transformer of stabilizer and Supply and fix new auto transformer for voltage stabilizer 4 KVA / 5 KVA capacity complete all as specified and as directed
All as per item No.57 here-in-before but for capacity upto 3 KVA.
Taking out unserviceable volt meter 0 to 300 Volts, Round / Square type as required and Supply and fix volt meter 0 to 300 Volts in Voltage stabilizer/ as per existing model complete all as specified and as directed .
Taking out burnt / unserviceable multi plug 3 pin socket, Supply and fix new 3 pin multi plug socket 5 / 15 Amps. 230 Volts for Voltage stabilizer complete all as specified and as directed. Make: Anchor/Cona/ Leader
Taking out defective relay, Supply and fix new relay for voltage stabilizer 3.0 KVA / 4.0 KVA / 5.0 KVA capacity complete all as specified and as directed.
All as per item No.61 here-in-before but for capacity 1.0 / 0.5 KVA.
Taking out burnt connector, Supply and fix electric connector 20 Amps in Voltage stabilizer complete all as specified and as directed
Supply and fix 3 pin plug top 15 Amps including taking down the existing unserviceable burnt one complete all as specified and as directed . Make: Anchor/Cona/ Leader
Supply and fix Metal clad plug socket three pin, 20A, 240V including taking down the existing unserviceable one complete all as specified and as directed.
WATER COOLER/REFRIGERATOR/DEEPFREEZER Servicing of water cooler 40/80 ltrs capacity , Cleaning of evaporating coil, condensing coil with water and brush to remove dust and checking of electric circuit for smooth functioning of Water coolers complete all as specified and as directed . Note: (a) Spares required shall be measured and paid under relevant items of schedule as supply only (b) Labour charges deemed to be included in the rate quoted for this item.
Supply only of suitable compressor for water cooler 40/80 ltrs including M&L leak test and gas charging etc., with necessary connecting arrangements all as specified and as directed . Note :Labour charges deemed to be included in the rate quoted for the item No.67 here in before
Supply only of the following items for water cooler 40/80 ltrs with connecting and necessary arrangements complete all as specified and as directed by Engr-in-charge Note :Labour charges deemed to be included in the rate quoted for the item No.67 here in before
Relay and OLP for water cooler
Thermostat for water cooler
SS Drain tray for water cooler
Drain hose for water cooler
Float valve assembly size 15mm
Supply only condensor fan motor suitable for 40/80 Ltrs capacity water cooler
Supply only condensor fan motor blade suitable for 40/80 Ltrs capacity water cooler
Supply only capacitor 10Mfd, 230 V, 50 Hz
Supply and fix push cock steel made suitable for water cooler
Supply and fix in replacement of suitable compressor for refrigerator 465 ltrs capacity including M&L leak test and gas charging etc., with necessary connecting arrangements all as specified and as directed
Supply and fix in replacement of Relay and OLP for Refrigerator of any capacity complete all as Specified and as directed
Supply and fix in replacement of PCB suitable for Refrigerator of any capacity complete all as Specified and as directed
Supply and fix in replacement of Evaparator fan motor suitable for Refrigerator of any capacity complete all as Specified and as directed
Material and Labour for Charging of refrigerant R-134A including leak detection,welding and testing the same in entire system, including replacing of defective liquid strainer and capillary tube for Refrigerator complete all as specified and as directed
Supply and fix in replacement of suitable compressor for Deep Freezer 400 ltrs capacity with gas Charging ,connecting and necessary arrangements all as specified and as directed.
Supply and fix condensor fan motor suitable for Deep Freezer 400 ltrs capacity
Supply and fix Thermostat switch
Supply and fix Relay and OLP for deep freezer
Material & labour Charging of refrigerant R-134A including leak detection, welding and testing the entire system, including replacing of defective liquid strainer and capillary tube for Deep freezer complete all as specified and as directed .
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .