Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.7 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹50.8 L+₹2.2 L (4.58%)Rejected-Finance E 11 CWE WELLINGTON A I A II A V B I | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance BEING NOT L1 BIDDER | |
| 3 | L3₹51.3 L+₹2.7 L (5.46%)Rejected-Finance 109 D ALLAI SALT COMPOUND OLD LAKSHMI THEATRE KRISHNAPURAM COONOOR 643102 THE NILGIRIS | COONOOR | THE NILGIRIS | TAMIL NADU | 643102 | L3 | Rejected-Finance BEING NOT L1 BIDDER | |
| 4 | L4₹51.5 L+₹2.9 L (5.89%)Rejected-Finance C 150 ADG P CHENNAI | L4 | Rejected-Finance BEING NOT L1 BIDDER | |
| 5 | L5₹52.2 L+₹3.6 L (7.44%)Rejected-Finance H NO 111 553 64 CATTLE POUND TOWARDS AVA HILL CAMP ROAD ARUVANKADU NILGIRIS DIST TAMIL NADU 643 202 | THE NILGIRIS | TAMIL NADU | 643202 | L5 | Rejected-Finance BEING NOT L1 BIDDER |
Tender Value
₹44.3 L
EMD Value
₹88,600
Closing Date
5 May 2025, 6:00 pmClosed
Shri Pawan Kumar Goswami,IDSE EE GE DSSC
BARRACKS-POST, WELLINGTON, THE NILGIRIS, TAMIL NADU, PIN-643231
SPL REPAIRS TO ROOF TREATMENT IN JCO OR MD ACCN INSIDE COLLEGE AREA AND RENOVATION OF WASH ROOM T22 T23 ON GROUND FLOOR OF AIR WING ADJACENT TO COTT AIR AND ACCTS OFFICE AT DSSC WELLINGTON
2025_MES_703705_1
8479/E8
Open Tender
Civil Works
Item Rate
180 days
WELLINGTON
PLEASE REFER TENDER DOCUMENTS AND NIT
8 documents required · 8 mandatory
₹500
GE DSSC WELLINGTON
₹88,600
Yes
2 Jul 2025
7 Apr 2025
7 May 2025
7 Apr 2025
5 May 2025
21 Apr 2025
Amount
Demolition of cement concrete (unreinforced ) of any description and in any postion not otherwise spcifically provided etc (below or above ground level)/sunken floors / roof pading etc and removing debris out side MD land complete all as spcified and as directed.
M&L Providing 40mm thick cement concrete type B0, 1:2:4 using 12.5 mm graded stone aggregate .as in floors for levelling course and as in padding concrete on roof mixed with WPC of approved make where necessary all as directed. Note: WPC will be measured and paid separately.
M&L for laying 3mm thick APP modified water proofing membrane weighing not less than 3.6 Kg/Sqm, reinforced with non woven polyster matt black finished weighing not less than 100 gm/Sqm having softening point not less than 140 degree celsius longitudinal tensile strength not less than 300 N/Sqm, minimum overlapping 10 cm on either side and 15 cm on ends lap over a coat of bitumen primer @ 0.20 Kg/Sqm and finished with aluminum paint @ 0.10 Ltr/Sqm all as per manufactures instruction and as directed by Engr-in charge. Note : The work shall be carried out by authorised applicators of manufactures.
M & L 20mm thick cement screed in cement mortar 1:3 mixed with liquid water proofing compound FOSROC's complast 421 IC @ 130ml per bag of cement including a bonding coat of FOSROC's Nito bond AR cement slurry for roof slab/ floor complete all as specified (liquid water proofing compound are measure seperately)
Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc, and removing debris out side MD land complete all as specified and as directed.
Material and labour for rendering 15 mm thick in Cement Mortar 1:4 mixed with liquid water proofing compound as per manufacturers' instructions on stone masonry surfaces of wall, finished even and smooth without using extra cement complete all as specified and as directed. Note: Liquid water proofing compound shall be measured and paid separately.
Supply only liquid water proofing compound of approved make complete all as specified and as directed.
M & L for Providing, cement concrete 1:3:6,type C-1 (20mm graded aggregates) in bed blocks /parapet walls benching, including weathering, slightly rounded or chamfered angles and throating, all as specified and directed.
S & F in repairs PVC tank cover for 500 /1000 Ltrs capacity complete.
Demolition of brick or stone/ boulder masonary, built in cement mortar and removing debris out side MD land complete all as specified
M&L Precast cement concrete type C1 1:3:6 (Using 20 mm graded aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed.
M&L Preparing newly plastered surfaces of external walls and applying exterior wall putty of 3mm thick for smoothness, one coat of exterior wall primer and two coats of Exterior Emulsion anti fungal weather proof paint APEX ULTIMA OF Asian Paint or WEATHER COAT SMOOTH of Berger complete all as per manufacturer instruction as directed.
M&L PCC 1:4:8 type D2 with 40mm graded stone aggregate as in sunken floor/toilet floor /kitchen floor/tank base concrete finished the surfaces even and fair to receive top layer all as specified and as directed.
M&L 100mm thick PCC 1:4:8 type D2 (40 mm graded aggregate) as in floor concrete finished even and rough to receive the top layer all as spcified and as directed.
M&L 75mm thick Plain Cement Concrete type C-1, 1:3:6 (20mm graded stone aggregate) as in floors, plinth protection etc. finished even & fair without using extra cement complete as specified and as directed.
Dismantling existing tanks exc. 250 lit & n. exc. 500 litres capacity, removing off the site complete all as specified and as directed.
Dismantling existing tanks exc. 500 lit & n. exc. 1000 litres capacity, removing off the site complete all as specified and as directed.
Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position of size exc 500 ltr but n.exc 1000 ltr.
Supply and Fix, 1000 litres capacity triple layered Rotational Moulded Polyethylene (HDPE) FDA grade materials water storage tanks, (Cylindrical vertical with closed top) screwed lid type conforming to IS 12701-1996 with manhole lid and suitable locking arrangement including making holes for inlet, outlet, washout and over flow pipes, hoisted and fixed in position as specified in SSR Part -I (2009) complete all as specified and as directed. Make: Sintex/Polycon/Vectus.
Supply and Fix, 500 litres capacity Rotational Moulded Polyethylene (HDPE) FDA grade materials water storage tanks, three layered (Cylindrical vertical with closed top) screwed lid type conforming to IS 12701-1996 with manhole lid and suitable locking arrangement including making holes for inlet, outlet, washout and over flow pipes, hoisted and fixed in position as specified in SSR Part -I (2009) etc., complete all as specified and as directed.
S&F 25mm bore, Ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed,weight 455 gms complete as specified and as directed.
S&F in Repair 25mm bore, Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete as specified and as directed.
S&F in Repair 20mm bore, Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete as specified and as directed.
Taking down steel tubing and connections of 15 mm bore including cleaning for refixing or removal to store complete all as specified and as directed.
Taking down steel tubing and connections of 20 mm bore including cleaning for refixing or removal to store complete all as specified and as directed.
Taking down steel tubing and connections of 25 mm bore including cleaning for refixing or removal to store complete all as specified and as directed.
S&F 15 mm bore Galvanised iron tubing, medium grade, with all fittings laid in trenches, floors or fixed to walls etc complete all as specified and as directed.
S&F 20 mm bore Galvanised iron tubing, medium grade, with all fittings laid in trenches, floors or fixed to walls etc complete all as specified and as directed.
S&F 25 mm bore Galvanised iron tubing, medium grade, with all fittings laid in trenches, floors or fixed to walls etc complete all as specified and as directed.
Refixing of old GI steel tubes and connections after cleaning of 15 mm bore in new or old position, any grade, to walls, ceiling, floors, etc complete all as specified and as directed.
Refixing of old GI steel tubes and connections after cleaning of 20 mm bore in new or old position, any grade, to walls, ceiling, floors, etc complete all as specified and as directed.
Refixing of old GI steel tubes and connections after cleaning of 25 mm bore in new or old position, any grade, to walls, ceiling, floors, etc complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required & pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; & cutting chases for concealed water tubing or concealed conduit wiring, etc.& making good, cutting not exc 10 cm grith in brick wall
Plain cement concerte 1:2:4 type B1 using 20 mm graded stone aggregate as in benching to chajjas/parapet walls etc.,
Dismantling single layer mangalore pattern or similar tiles in roofing and removing debris out side MD land complete all as specified and as directed.
M&L Roof tiles, Mangalore pattern,interlocking at side joints, laid in cement mortar complete all as specified.
Fixing only roof tiles mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed.
M & L for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6
All as per item No. 38 here-in-before but exept tiles
Dismantling battens for tiles, shingles etc of any size including tilting fillets.
S&F for 2nd class hardwood tile battens clean sawn witrh sectional area exc 15 sqcm but n exc 25 sqcm at 30 cm centres complete all as specified and directed.
All as per item No. 41 here-in-before but except battens
Dismantling of unframed timber scantlings 40 sq. cm and over in section, in any position tile battens as in roofing and removing debris out side MD land complete all as specified and as directed.
S&F for 2nd class hard-wood scantlings clean sawn timber framed and fixed as in roof members complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails and removing debris out side MD land complete all as specified.
S&F for 20mm thick 2nd class hard wood boarding, supplied and fixed with nails in any situation (except flooring and skirting) complete all as specified and directed.
M & L for preparation of new painted surfaces of wood and wood based materials of any description not other wise described over 10 cm width or girth and applying Two coat of synthetic enamel paint over a pink primer coat complete all as specified and directed Engr-in-Charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified.
S&F for 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc with grade of zinc coating 275,in pache, all as specified and directed.
Fixing only 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc with grade of zinc coating 275 all as specified and directed.
S&F in repairs For pre-painted Galvalume aluminium Zinc cooating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in covering/cladding to wall fixed with self tapping screws all as specified and directed.
Fixing only pre-painted Galvalume aluminium Zinc cooating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and directed.
S&F in repairs For pre-painted Galvalume aluminium Zinc cooating GI based Plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in covering/cladding to wall fixed with self tapping screws all as specified and directed.
Fixing only pre-painted Galvalume aluminium Zinc cooating GI based Plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line overall as fixed along the centre line over fittings and accessories) Note :- Rate for fixing the gutter upto 10mtr height deemed to be included in quoated rate by the contractor.
S & F in repair PVC half rounded gutter dia 250 mm (CL-2) (6 kg/cmsq) all as specified and as directed. Note :- Rate for fixing the gutter upto 12 mtr height deemed to be included in quoated rate by the contractor.
Fixing Only PVC half rounded gutter dia 250mm (CL-2) (6 kg/cmsq)fixed with suitable MS brackets all as specified and as directed. Note :- Rate for fixing the gutter upto 12 mtr height deemed to be included in quoated rate by the contractor.
S & F in repair PVC half rounded gutter dia 160mm (CL-2) 0.4 Mpa (6 kg/cmsq) all as specified and as directed.
Fixing Only PVC half rounded gutter dia 160mm (CL-2) 0.4 Mpa (6 kg/cmsq)all as specified and as directed
S & F in repair PVC Pipe dia 160mm (CL-2) 0.4 Mpa (6 kg/cmsq) fixed with suitable MS brackets vertical surface of wall all as specified and as directed
Fixing Only PVC Pipe dia 160mm (CL-2) 0.4 Mpa (6 kg/cmsq) fixed with suitable MS brackets vertical surface of wall all as specified and as directed
S&F in repair PVC bends 160mm dia all as specified and as directed.
S&F in repair PVC bends 250mm dia all as specified and as directed.
S&F in repair 160mm dia PVC half rounded gutter(Single `T') equal or unequal all as specified and as directed.
S&F in repair 160mm dia PVC ends all as specified and as directed.
S&F in repair 250mm dia PVC half rounded gutter(Single `T') equal or unequal all as specified and as directed.
S&F in repair 250mm dia PVC ends all as specified and as directed.
S & F in repairs 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches/ wall etc complete.(6 Kg/ cm Sq).
Fixing only for 110mm dia PVC (SWR) pipes single socketted, in any length with rubber ring joints, fixed to walls with suitable MS clamps.
S & F in repairs 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches/ wall etc complete .(6 Kg/ cm Sq).
Fixing only for 75mm dia PVC (SWR) pipes single socketted, in any length with rubber ring joints, fixed to walls with suitable MS clamps.
Dismantling of structural steel work including door ,gates, framed truss, rafter,purlins etc
S & F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors ladders framed balusters; walk ways railings ; framework of water tanks and similar work confroming to Fe 410-0 or Fe 310-0 all as specified and directed.
S&F Rolled mild steel works such as in main and cross beams, hip and jack rafters, purlins, angle cleats or other connecting plates, as in rain water gutter clamps etc. conforming to Fe-410-W(Gde E-250) quality-A
M&L steel work in tubular post,trusses including special shaped washer etc..complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade E-250 all as specified.
M&L for Preparation of new/previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer.
Demolition of cement concrete (unreinforced ) of any description and in any postion not otherwise spcifically provided etc (below or above ground level)as in roof pad /floors etc and removing debris off the site complete all as spcified and as directed.
Demolition of Brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including al;l quoins,arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles and removing debris off the site.
Demolition of floor hearth or wall tiling laid bedded and pointed in any mortar (but not backing) and removing debris off the sitecomplete all as specified and directed.
Taking down chowkats or frames of door including shutters (without taking off shutters from the frames) n exceeding 1.50 Sqm each complete all as specified and directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frames) exceeding 1.50 Sqm and not exceeding 4 Sqm each complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc, and removing debris off the site complete all as specified and as directed.
M&L for providing UPVC Door with Shutters. The construction profile for UPVC Door shall be overall frame sectional size 60 x 58 mm with wall thickness 2.70 +/- 0.2 mm extruded sections. The corners shall be plastic welded. The hinge side vertical outer frame shall be reinforced with galvanised steel profile of wall thickness 1.2 mm +/- 0.2 mm. The door shall be fixed to walls using 8 mm dia 80 mm long MS screws minimum 3 Nos on each side. The glazing shall be fixed to door frame with UPVC standard beadings of sectional size 24.05 x 16 mm & 2 mm thick. The shutter shall be fixed to frame using 3 nos of 3D hinges. The Door shutter shall be provided with toughened glass not less tha 6mm thick /5 mm thick UPVC board with EPDM Rubber gasket , zinc plated mild steel multipoint locking arrangement with zinc alloy (white powder coated) handles and two numbers zinc alloy (white powder coated) tower bolts complete all as specified & as directed Note: For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.all as specified and directed .The unit rate quoted by contractor includes cost of glass/UPVC board and all other connected accessories. Make: Madhu Industries / Fenesta / Qute /Sarvesh Multi Plast India Ltd/ SMP Impex /H20 Solution or equivalent. .
M&L for providing UPVC Door with Shutters. The construction profile for UPVC Door shall be overall frame sectional size 60 x 58 mm with wall thickness 2.70 +/- 0.2 mm extruded sections. The corners shall be plastic welded. The hinge side vertical outer frame shall be reinforced with galvanised steel profile of wall thickness 1.2 mm +/- 0.2 mm. The door shall be fixed to walls using 8 mm dia 80 mm long MS screws minimum 3 Nos on each side. The shutter shall be fixed to frame using 3 nos of 3D hinges. The Door shutter shall be provided with 5 mm thick UPVC board with EPDM Rubber gasket , zinc plated mild steel multipoint locking arrangement with zinc alloy (white powder coated) handles and two numbers zinc alloy (white powder coated) tower bolts complete all as specified & as directed. Note: For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.all as specified and directed .The unit rate quoted by contractor includes cost of glass/UPVC board and all other connected accessories. Make: Madhu Industries / Fenesta / Qute /Sarvesh Multi Plast India Ltd/ SMP Impex /H20 Solution or equivalent. .
S&F for UPVC Fixed ventilators with glazing made up of (small series) frame 47x50mm, mullion 47 x68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (area upto 0.75 sqm), compirising of UPVC multi chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60± 0.2 mm thick galvanised mild steel section made from roll forming process of required length (shape& size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, GI fasteners 100x8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. ((Note: The unit rate quoted by contractor includes the cost of glass and includes necessary modification of ventelator according to the site requirement such as opening for exaust fan, lauvers etc and all other connected accessories. Net opening will be measured for payment purpose.) Make : Madhu Industries / Fenesta / Qute /Sarvesh Multi Plast India Ltd/ SMP Impex /H20 Solution or equivalent. .
S & F White/Coloured UPVC partition fixed complete all as per manufacturer's instructions and following specifications all as directed:- (i) UPVC fixed partition frame shall be made of material confirming to IS 10151 of extruded UPVC section having over all dimension of 65 x 55 having wall thickness 2mm ± 0.2mm. (ii) Corners of frame shall be jointed by MS galvanized brackets mitred and plastic welded. (iii) The profiles should be single chamber system which shall provide high insulation properties. (iv)Partition consisting of solid UPVC shutter with with UPVC Panels of thickness not less than 7 mm/toughened glass not less than 10 mm thick , as per requirement fixed in frames with appropriate beading as per manufacturer's specification. (v) All the fittings shall be provided with using self tapping screws. Note: The entire fixing shall be done as per manufacturer's instructions and specification and as directed by Engr-in-Charge. For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.all as specified and directed .The unit rate quoted by contractor includes cost of glass/wire netting and all other connected accessories. Make: Madhu Industries / Fenesta / Qute /Sarvesh Multi Plast India Ltd/ SMP Impex /H20 Solution or equivalent. .
M&L PCC 1:4:8 type D2 with 40mm graded stone aggregate as in sunken floor/toilet floor /roof slab/kitchen floor concrete finished the surfaces even and fair to receive top layer all as specified and as directed.
M&L cement concrete type B1 1:2:4 using 20mm graded stone aggregate 40mm thick as in flooring.
M/L for non skid ceramic coloured tiles 7mm to 8 mm thick(square/rectangular) area of each tile exceeding 0.06 Sqm, but not exceeding 0.18 Sqm , in floors over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as spfd & directed.
M&L for glazed coloured ( 350 x 450 mm/600mm x300mm) x 7 mm th as in skirting/dado over & including 10mm thk rendering in CM 1:4 set on brick/PCC Block masonry/concrete surface & jointed in neat cement sullry & pointed in white or coloured cement to match complete all as spfd & directed.
M&L for precast solid block exceeding 10 cms in width 1:3:6 type C1 (using 20mm graded aggregate) and set in cement mortar 1:6 all as specified and as directed
M&L 15mm thick rendering plaster on fair face of brick-work or concrete surface incl finish the surface even and smooth without using extra cement in CM 1:6 complete all as specified and as directed .
M&L for Peparation of new plastered or unplastered surfaces of walls and applying two coats of Oil bond distemper white or tinted over one coat of alkali resistant primer over 3mm thick wall care putty complete all as spfd.
M&L rendering 5 mm thick on fair faces of brick work or concrete surfaces in CM 1:3 on ceiling and finishing the surface even and smooth without using extra cement.
M&L for preparing new plastered surfaces of ceilling and applying three coats of white wash.
M&L for PVC insulation panels 10mm thick with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid of GI frame for seamless ceiling comprising of GI perimeter channel .55mm thick with two unequal flanges of 20mm &30mm and web of 27mm fixed to sarrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm c/c with GI cleat and steel expansion fasteners with and including ceiling section(not exc 1.2 metre length)of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm c/c, provision of hangers 6mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5 mm dia 40mm long,complete all as specified & directed.
Taking down or up steel tubing and connections inculding cleaning for refixing or removal to store 15mm bore.
Taking down or up steel tubing and connections inculding cleaning for refixing or removal to store 20mm bore.
Material and labour for Aluminium designer powder coated decorative curtain rods antique finish 25mm dia dia, exterior grade 3mm thick with and including side caps, holding clamps and 'F' and 'L' brackets, fixed to wall with PVC rawl plug and brass screws etc., complete all as specified and as directed.
Supply and fixed in repair Vitreous china wash down water closet pan, pedestal pattern, colour white, closed pattern with flat bottom with and including white coloured PVC seat cover, mild steel chromium plated or aluminised hinging device flushing cistern and P/S trap including connections to drain (or outgoing pipe) and taking down existing water closet etc., complete all as specified and as directed. Make : Jaquar/Parryware/Hindware or equivalent.
S&F in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern)including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, urinal spreader, grating,waste pipe and Union for discharge pipe. Make : Jaquar/Parryware/Hindware or equivalent.
Supply and fix in repair Vitreous china Wash Hand Basin, White, counter top oval type of size 550x450x200mm as per Cat No.FLS-WHT-5701 of Jaquar (or) C0431 Cascade NXT of Parryware or Cat No.10017 of Hindware or equivalent of other specified makes, fixed over an d including including 32mm waste coupling, 32mm dia waste pipe750mm long etc.,including taking down existing one complete all as specified and as directed.Note: The unit rate quoted shall be deemed to include the cost of WHB, Granite slab, brackets, waste coupling and waste pipe. Make : Jaquar/Parryware/Hindware or equivalent.
Supply and fix in repairt angular stop cock 15mm bore, cast copper alloy, chromium plated, fancy type with long shank conforming to IS as per Cat No.CON-053KN of Jaquar or G3053A1 of Parryware, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified and as directed. Make : Jaquar/Parryware/Hindware or equivalent.
S& F in repair Pillar cock cromium plated with wall flange complete .screwed down high pressure, with or without lettered Hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed. Make : Jaquar/Parryware/Hindware or equivalent.
S&F in repairs Bib cock (Two in one) with health faucet multi type including flexible hose complete all as specified and as directed. Make : Jaquar/Parryware/Hindware or equivalent.
Dismantling of cast iron/PVC pipes of any diameter and in any position.
Supply and fix galvanised steel water tubing 15 mm bore, medium grade with all fittings and fixed complete to walls/ceiling or laid in floors complete all as directed by the Engr-in-Charge.
Supply and fix galvanised steel water tubing 20 mm bore, medium grade with all fittings and fixed complete to walls/ceiling or laid in floors complete all as directed by the Engr-in-Charge.
S&F in repairs 5.50mm thick looking mirror of size 900x600mm mounted on 6mm thick Plywood backing or AC sheet backing including framing with 1st class hard wood of size 40x40mm decorative type polished and fixed to wooden plugs with chromium plated brass screws and cupwashers/or chamferred glass from all sides fixed with steel screws all as specified and directed by Engr-in-Charge. Make :MODI/SAINT GOBAIN/HINDUSTAN GLASS or equivalent
Supply and fix in repair Towel rail 450 mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats.Make : Jaquar/Parryware/Hindware or equivalent.
S&F in repairs toilet paper holder brass CP rod to insert paper roll mounted and screwed to walls complete all as specified and as directed.Make- Jaquar/Parryware/Hindware or equivalent.
S&F in repair stainless steel soap dish of size min 100 mm dia or square or rectangular complete all as specified and as directed. Jaquar/Parryware/Hindware or equivalent
Supply and fix in repair 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches complete all as specified and as directed.
Supply and fix in repair 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
Supply and fix in repair PVC connections 15mm size with brass nuts of length 600 mm each complete all as specified and as directed.
Supply and fix in repair 110 mm dia PVC floor trap with grating including jointing to waste pipe with hole for waste pipewith 100 dia CP grating fix with cement mortar including jointing to waste pipe complete all as specified and as directed.
S/F 110mm PVC (SWR) junction single, bends with access door type
S/F 75mm PVC (SWR) bends with access door type
S/F 110mm PVC (SWR) junction single, (Single T) equal or unequal with access door type
S/F 75mm PVC (SWR) junction single, (Single T) equal or unequal with access door type
S/F 110mm PVC (SWR) junction single, (Single T) equal or unequal with access door type
S/F 75mm PVC (SWR) junction single, (Single T) equal or unequal with access door type
M&L for complete removal of existing treatment, preparation of plastered surfaces of walls applying two coats of distemper, oil emulsion including alkali resistant primer over 3mm thick wall care putty complete all as specified and directed.
Taking down and Refixing the solar hot water system by disconnecting inlet and outlet pipe of water heater, removing existing submain wiring, removing all existing water supply inlet pipe line from roof top and by disconnecting solar panel. Note: (i) The above mentioned taken over items should hand over to MES store for safe custody for refixing the same. (ii) Item will be measured and paid after successful reinstallation, testing and commissioning.
S & F in repair 20 mm bore water tubes, medium grade galvanised with all fittings including suitable insulation with 9 mm thickness with aluminium foil externally and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Supply and fix in repair solar water heater heating element with thermostat of 2 kW, 220 V complete all as specified and directed.
Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable4 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 4 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings and including taking down old unsv sub main wiring of any size. Complete all as specified and directed. Note: 03 Runs of 4 sqmm cable and conduit measured together as one run meter.
Cutting chases in stone masonry wall/concrete floor/roof for laying PVC conduit and making good to facings where required and pointing in cement mortar 1:3, and making good, cutting not exc 10cm girth.
Taking down point wiring (light, fan, socket or power) complete , including fixture and fittings such as switches, ceiling roses, sockets, light fitting, bell etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L for point wiring concealed complete with 1.5 sqmm (nominal area) FRLS grade PVC insulated, unsheathed stranded copper conductor single core cable 1100 volts grade in and including PVC conduit medium grade complete with conduit fittings/accessories with provn of MS terminal boxes of suitable size including provn of housing of switches, and sockets etc including 1.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor for earth continuity conductor and connected to common earth dolly for the followings :
One light point or one fan point controlled by one switch with cables 1.5 sq. mm size complete all as specified and directed.
One 3 pin socket outlet, 5 amps, independent, with cables 1.5 sq. mm size complete all as specified and directed.
All as per item No.130 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board complete all as specified and directed.
M&L for Modular switch 1 way 6A, 1 module complete all as specified and directed.
M&L for Modular switch 1 way 16A,1 module complete all as specified and directed.
S&F Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.
S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
S&F modular Metal flush box 2 module complete all as specified and directed.
S&F modular Metal flush box 3 module complete all as specified and directed.
S&F modular Metal flush box 6 module complete all as specified and directed.
S&F modular white cover plate with frame, 2 module complete all as specified and directed.
S&F modular white cover plate with frame, 3 module complete all as specified and directed.
S&F modular white cover plate with frame, 6 module complete all as specified and directed.
Taking down Submain wiring with aluminium conductor along with PVC Conduit and Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 2.5 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 2.5 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings all as specified and directed.
Taking down old unsv light fittings and Supply and fix in repair round shape 12 watt 220 volts AC 6000K, min lumen out put 100 lum/Watts,recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
Cutting chases in stone masonry wall/concrete floor/roof for laying PVC conduit and making good to facings where required and pointing in cement mortar 1:3, and making good, cutting not exc 10cm girth.
Supply and fixing in repair LED tube light fitting 2 feet, 10 watt 220 V, AC, 6000K, min lumen out put 100 lum/Watts, decorative type with driver including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix for ceiling rose 3 terminals PVC/Poly Carbonate isolated body incl base block complete all as specified.
Taking down old DB box and Supply and fix in concealed Distribution board sheet steel phosphatised powder coated for MCB/DB with copper bus bar and neutral link earthing stud (confirming to IS-13032, IS-8623) 8 way with 200 amps rated bus bar
Supply and fix MCB SP 06 to 32 Amps, 240 Volts, 50 Hz AC supply complete all as specified.
Supply and fixing MCB SPN 32 Amps rating 240 V,10KA'C' curve miniature circuit breaker (MCB) of following poles and current carriying cappacity in the MCB DB complete with connection testing and commitioning all as specified.
Taking down old unsv exhaust fan of any size and Supply and fix in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed.
VENKATESH (BID ID -3291817)
K.AYYAPPAN (BID ID -3291827)
S.RAMACHANDRAN (BID ID -3292144)
sree devi construction (BID ID -3292054)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .