Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹43.0 L+₹12,555 (0.29%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹44.7 L+₹1.8 L (4.25%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹47.1 L+₹4.2 L (9.78%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹49.6 L+₹6.8 L (15.8%)Rejected-Finance 12 2 332 21 HILL COLONY OPP SUNRISE SCHOOL MEHDIPATNAM HYDERABAD 500028 | HYDERABAD | HYDERABAD | TELANGANA | 500028 | L5 | Rejected-Finance Not lowest |
Tender Value
₹48.8 L
EMD Value
₹97,600
Closing Date
28 Dec 2021, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
PROVISION OF WEATHER PROOF EXTERIOR ACRYLIC EMULSION TO BLDG Nos.P-02, 09, 56, 71, 92, 116, 119, 08, 124, 151, 174 AND 138 AT DMRL (PHASE III) AND CERTAIN SANCTIONED WORKS UNDER GE (I) RND KANCHANBAGH HYDERABAD
2021_MES_488637_2
GE I KBAGH TOKEN 61 OF 2021 2022
Open Tender
Civil Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹97,600
Yes
10 Jan 2022
7 Dec 2021
30 Dec 2021
7 Dec 2021
28 Dec 2021
14 Dec 2021
8 Dec 2021 - 13 Dec 2021
Amount
Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking out for key, scrubbing down with water etc complete all as directed. Note:- Work shall be carried out upto 20 mtr height. Quoted rates are deemed to be inclusive of necessary scoffolding whereever required.
M&L rendering 15mm thick on stone masonry surfaces or surface other than fair face of brick work in cement mortar CM 1:4 in two layer (First coat 10 mm thick and second 5 mm thick) mixed with water proofing compound @3% by weight of cement (in top layer ) and finished even & smooth. (WPC will be measured and paid separetly) Note :- Work shall be carried out upto 20 mtr height. Quoted rates are deemed to be inclusive of necessary scoffolding whereever required.
Supply only integral water proofing compound complete all as directed.
M&L for complete removal of existing treatment from external surfaces of walls/ ceiling, washing with water and applying two coats of weather proof antifungal exterior paint as per manufacturers instructions over a coat of true care exterior wall primer over two coats of external birla putty 1.5mm thick each layer each to level the surface and finished smooth with emery paper No.180 followed by emery paper No.320 or 400 and wipe it clean complete all as specified and as directed by Eng-in-charge. Make:- APEX ULTIMA of ASIAN PAINT/ WEATHER COAT SMOOTH(BERGER PAINTS)/ WEATHER SHIELD MAX EXTERIOR ACRYLIC(DULUX)
M&L for preparation of new plastered surfaces and applying two coats of weather proof antifungal exterior paint as per manufacturers instructions over a coat of true care exterior wall primer over two coats of external birla putty 1.5mm thick each layer to level the surface and finished smooth with emery paper No.180 followed by emery paper No.320 or 400 and wipe it clean complete all as specified and as directed . Make:- APEX ULTIMA of ASIAN PAINT/ WEATHER COAT SMOOTH(BERGER PAINTS)/ WEATHER SHIELD MAX EXTERIOR ACRYLIC(DULUX)
S&F rectangular aluminium hollow section, powder coated of approved colour, of size 101.60 mm x44 mmx2 mm thick as in partition including fixing with suitable size of nuts, bolts in floors and walls by drilling holes, both vertical and horizontal members including provision of sheet glass 5.5 mm thick and 12 mm thick particle board prelaminated on both side with decorative choice lamination, aluminium legs, sun control film, aluminium glazing channel, rubber beading, complete all as specified and directed by Eng-in-Charge.
S&F Gypsum board false ceiling with GI grid suspeded with 2mm dia GI wire at 600mm c/c, holding and level clips, Gypsum board of 12.5mm thick with white paper layer on face side of size 600 x 600 mm as directed and applying two coats of acrylic emulsion paint over a coat of primer all as directed by Eng-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and paving any thickness below or above ground level, removal of rubbish and debris and depositing in low lying areas complete all as directed.
M&L 75 mm thick PCC type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in sub base complete all as directed
M&L 100 mm thick PCC type B-1 1:2:4 (using 40 mm graded stone aggregate) as in floors finished even and smooth without using extra cement complete all as directed
M&L for preparation of old plastered surfaces of walls and applying one coat of weather proof antifungal exterior paint including filling crack by putty complete all as specified and as directed. Make:- APEX ULTIMA of ASIAN PAINT/ WEATHER COAT SMOOTH(BERGER PAINTS)/ WEATHER SHIELD MAX EXTERIOR ACRYLIC(DULUX)
M&L for point wiring complete with 1.5 Sqmm PVC insulated unsheathed single core multistranded copper conductor 1100 V grade drawn through in and including 20 mm dia in stove enamelled steel conduit concealed on walls/ in existing Conduit on Ceiling and Terminated to sunken box of modular type including white cover plates suitable for fixing switches, sockets etc including 1.5 Sqmm PVC insulated Copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed for the following:-
One light point controlled by one way modular switch 6 Amps
One ceiling fan point /Exhaust fan point controlled by one 5 Amps one way switch and regulator
One 3 pin 5 Amps switch socket outlet point on independent board
One 3 pin socket outlet 5 Amps on the same board with other switches.
M&L for point wiring complete with 2.5 Sqmm PVC insulated unsheathed single core multistranded copper conductor 1100 V grade drawn through in and including 20 mm dia PVC conduit concealed on walls/ in existing Conduit on Ceiling and Terminated to sunken box of modular type including white cover plates suitable for fixing switches, sockets etc including 2.5 Sqmm PVC insulated Copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed for 3 in one 3 pin socket outlet. 15 amps, independent:- Make:- Conductor: Finolex/Finecab/Polycab/Plaza PVC Conduit: Finolex/Tirupati/Supreme/Prince/Avon plast/ Plaza
S&F modular switch one way 6 amps 1 module
S&F modular switch one way 16 amps 1 module
S&F modular fan step type regulator two module
S&F modular socket out let 6 Amps 230 volts AC 3 pin multipurpose type complete all as directed.
S&F modular socket out let 6/16 Amps multipurpose complete all as directed by Engineer-in-Charge.
S&F ceiling rose two to three terminal surface backallite type AC 50Hz 230 volts complete
S&F LED Betten type light fitting 1x18/20 W, 4ft Extruded aluminium batten suitable for surface mounting complete
Supply & fix LED down lighter,fully diffused recessed mounted 2'x2', 30/35 W, 6500K, with high transmitive diffuser suitable for indoor complete
S&F MCB single pole 5 Amp to 32 Amps complete all as directed by Engr-in-charge
S&F MCB SPN 240 Volts 40 Amps complete ( for Acs -02Nos)
S&F MCB TPN 415 Volts 40 to 100 Amps complete ( 01 for incoming and 01 for Equipment),
S&F in replacement Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 32Amps MCB complete all as specified.
S&F sheet metal enclosure MCB DB TPN double door type AC 415 V 4 way with 200 Amps rated bus bar, including taking down old one complete and making good of distructed surface.
M&L for sub main wiring complete with 2 runs of 04 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through in and including PVC conduit of suitable size and connecting terminal ends to meters and DB's including provision of 1 run of 04 Sqmm insulated copper cable for earth continuity conductor and connecting to earth dolly complete all as directed by Eng-in-charge
M&L for sub main wiring complete with 4 runs of 06 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through in and including PVC conduit of suitable size laid on wall/floor with suitable size clamps and connecting terminal ends to meters and DB's including provision of 1 run of 06 Sqmm insulated copper cable for earth continuity conductor and connecting to earth one complete all as directed by Eng-in-charge
M&L for sub main wiring complete with 4 runs of 10 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through in and including PVC conduit of suitable size laid on wall/floor with suitable size clamps and connecting terminal ends to meters and DB's including provision of 1 run of 10 Sqmm insulated copper cable for earth continuity conductor and connecting to earth dolly complete all as directed by Eng-in-charge
M&L for earthing complete with GI earth plate electrode 600x600x6mm buried directly in ground vertically to a depth of not less than 2.25mtr below ground level connected to GI wire 4 mm by means of bolts washers etc made out of GI earth wire will be protected by galvanized iron pipe medium grade 15mm bore up to main distribution board/main switch including necessary excavation and earth work PCC 1:3:6 type CI (using 20mm graded stone aggregate) RCC cover 1:2:4 type B1 including necessary reinforcement etc complete all as shown on electric plate No.3 of MES Such Part-I., and as directed by Engineer-in-Charge.
M&L for earthing complete with Copper earth plate electrode 600x600x3.15mm buried directly in ground vertically to a depth of not less than 2.25mtr below ground level connected to copper strip 20x3 mm by means of bolts washers etc made out of GI earth wire will be protected by galvanized iron pipe medium grade 15mm bore up to main distribution board/main switch including necessary excavation and earth work PCC 1:3:6 type CI (using 20mm graded stone aggregate) RCC cover 1:2:4 type B1 including necessary reinforcement etc complete all as shown on electric plate No.3 of MES Such Part-I., and as directed by Engineer-in-Charge.
M&L as Chemical Earthing (Bentonite chemical)complete with Copper earth plate electrode 900x600x5mm buried directly in ground vertically to a depth of not less than 2.25mtr below ground level connected to copper strip 32x6mm by means of bolts washers etc made out of GI earth wire will be protected by galvanized iron pipe medium grade 15mm bore up to main distribution board/main switch including necessary excavation and earth work PCC 1:3:6 type CI (using 20mm graded stone aggregate) RCC cover 1:2:4 type B1 including necessary reinforcement etc complete all as shown on electric plate No.3 of MES Such Part-I., and as directed by Engineer-in-Charge.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm dia galvanised iron strip
Supply and install, test and commissioning of hi wall split AC units indoor/ outdoor complete with cordless remote control unit with ISEER 5 star rating, of capacity 2 TR with CFC free Regrigerant gas like R-32/ 410a suitable to operate on 230V single phase supply, Refrigerator copper tube of suitable dia from indoor to outdoor unit, insulation felt to copper tubing, power cable/control wiring from indoor unit, provision of rigid UPVC condesate drain piping from indoor unit to ground level etc, all as directed. Make: VOLTAS/HITACHI/BLUESTAR
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5KVA complete all as directed.
M&L for Isolation tranformer, testing & commissioning of copper wound Isolation Transformer filling of 25KVA Three Phase oil cooled type including transformer oil, Potential difference between neutral to earth less than one volt with all standard fittings like digital tempreture meter, adequate number of cooling rediators, lifting hooks one set earthing terminal two nos complete with over load/short circuiote protection complete all as directed:- TECHNICAL SPECIFICATION
1. Input Voltage : 415 Volts + 5% 2. Output Voltage : 415 Volts + 5% 3. Vector Group : Dyn 11 4. Primary connection : Delta & Secondary connection : Star 5. Frequency : 50 Hz, three Phase 6 Coupling Capacitance : less Than 0.01pF 7. C.M.N.R : 100db 8. Type of colling : Natual oil cooled 9. DG Galvanic Insulation : Over 100 Mega Ohms between any winding/ winding to ground. 10. Ambient tempreture : - 1 degree celcius to 50 degree celcius 11. Transformer ratio : 1:1 12. Power Factor : 0.9 lag to lead 13.Insulation Class A, Insulation resistance : more than 100M Ohms 14.VI Electric strength : 2500V AC for 120 Sec 15. Class of insulation : Class 'F' 16. Losses : 1.5%-2% 17. Duty cycle : Continuous 18. Lamination : CRGO 19. Efficiency : More than 98% 20. IS conforming to : IS 9815 Make: Vinitek Electronic (Volina)/ Brill tech/ Trinity clean tech Pvt Ltd.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core
K LAKSHMAN SINGH AND CO
M/s Kasturi Pedda Subbaiah Enterprises/M/s K.P.S Enterprises
Bismi Engineering
rahi consultant
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .