Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹34.9 L Quoted ₹35.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹36.6 L+₹1.2 L (3.25%)Rejected-AOC | ₹36.6 L+₹1.2 L (3.25%) | L2 | Rejected-AOC L2 |
| 3 | L3₹36.7 L+₹1.3 L (3.69%)Rejected-AOC | ₹36.7 L+₹1.3 L (3.69%) | L3 | Rejected-AOC L3 |
| 4 | L4₹37 L+₹1.6 L (4.46%)Rejected-AOC | ₹37 L+₹1.6 L (4.46%) | L4 | Rejected-AOC L4 |
| 5 | L5₹42.1 L+₹6.7 L (18.8%)Rejected-AOC | ₹42.1 L+₹6.7 L (18.8%) | L5 | Rejected-AOC L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 May 2020, 6:00 pmClosed
GE SATWARI
GE SATWARI
REPLACEMENT OF LT PANELS, MCCBS, CAPACITOR BANKS AND ALLIED WORKS UNDER GE SATWARI
2020_MES_342058_1
GEJM-32/20-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SATWARI
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE SATWARI
₹80,000
Yes
9 Jul 2020
1 May 2020
1 Jun 2020
1 May 2020
29 May 2020
15 May 2020
Amount
Disconnecting the electrical connections from feeder pillar/LT panel, taking down the unserviceable feeder pillar/LT panel from plinth and transportation to workshop for repair. After repair the same will be transported at site & install the original position including making all electrical connections with appropriate size of new lugs complete all as specified and directed. Note : Repair items will be provided in respective schedule of items.
Taking out the broken hinges/unserviceable hinges & door handles from feeder pillar/LT Panel and replace with cold rolled MS hinges of appropriate size through spot welding & Mild steel sliding door bolt including making necessary adjustment for free and smooth movement of panel and 2 coat of powder coated spray painting inside & outside the panel complete all as specified and directed.
Taking out the burnt /unserviceable bus bar of any capacity and length, copper cable inter connections including insulators from feeder pillar/LT Panel & replace with appropriate size and capacity of aluminium bus bar & insulators with new S/S nut bolts and washers including appropriate size of copper cable inter connections complete all as specified and directed.
Taking out the damaged/deshaped part/portion of the LT Panel/feeder pillar and repalce with new portion of LT panel/feeder pillar made out of CRCA sheet 3mm thick including making necessary adjustment and allignment to make the existing feeder pillar/LT Panel to its required shape and size with 2 coats of powder coated spray painting inside and outside the complete panel all as specified and directed.
Taking out the existing unserviceable voltmeter, ammeter, phase indication lamps, CTs of any description and size and S&F digital voltmeter, ammeter, phase indication lamps,fCTs as per existing capacity and sizes all as specified and directed. Make :- L& T equivalant in AE / Enercon /Rishab.
Supply and Fixing in replacement of ACB 800A, draw out type, shall confirm to IEC 60947 /IS 13947 (Part 1 & 2). The minimum breaking capacity should be 50KA. The service short circuit breaking capacity (Ics) should be equal to ultimate breaking capacity (Icu) and short time with stand capacity (Icw) with ICS =Icu=Icw. The Icw value is for 1sec. The ACB shall have microprocessor based LSIG protection units with flexible and adjustable current - time protection settings for overload, short circuit, instantaneous short circuit and Earth Fault Protections. ACB should be suitable for a 3 phase service voltage, up to 690V for 50 Hz AC supply and shall have an insulation voltage of 1000V. All the protection units should have built in Dedicated inbuilt LEDs for fault indication for overload, short circuit and Earth Fault. Makes : Legrand(DMX3)/schneider(MASTERPACT NW)/Siemens(3WL).
Supply and fixing in replacement of unsv MCCB 630 Amp 4 pole 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.422009 or equivalent to Schneider(NSX)/Siemens(3VL)
Supply and fixing in replacement of unsv MCCB 400 Amp 4 pole 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.422007 or equivalent to Schneider(NSX)/Siemens(3VL)
Supply and fixing in replacement of unsv MCCB 4 pole 320 Amp, 36 KA and thermal and magnetic releases with Ics=100%Icu. conferming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection.Make: LEGRAND Model No DPX>3 Cat Part No 422006 or equivalent to Schneider(NSX)/Siemens(3VL)
Supply and fixing in replacement of unsv MCCB 250 Amp 4 pole 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420249 or equivalent to Schneider(NSX)/Siemens(3VL)
Supply and fixing in replacement of unsv MCCB 200 Amp 4 pole 25 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420218 or equivalent to Schneider(NSX)/Siemens(3VL)
Supply and fixing in replacement of unsv MCCB 160 Amp 4 pole 25 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420057 or equivalent to Schneider(NSX)/Siemens(3VL).
Supply and fixing in replacement of unsv MCCB 125 Amp 4 pole 16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420016 or equivalent to Schneider(NSX)/Siemens(3VL)
Supply and fixing in replacement of unsv MCCB 100 Amp 4 pole 16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420015 or equivalent to Schneider(NSX)/Siemens(3VL)
Supply and fixing in replacement of unsv MCCB 63 Amp 4 pole 16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420013 or equivalent to Schneider(NSX)/Siemens(3VL)
Supply and fixing in replacement of unsv MCCB 100 Amp 3 pole 16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420005 or equivalent to Schneider(NSX)/Siemens(3VL)
Supply and fixing in replacement of unsv MCCB 125 Amp 3 pole 16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420006 or equivalent to Schneider(NSX)/Siemens(3VL)
Supply and fixing in replacement of unsv MCCB 63 Amp 3 pole 16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420003 or equivalent to Schneider(NSX)/Siemens(3VL)
Supply and fixing in replacement of unsv MCB TPN 63 Amps 10 KA C Curve in existing panels including making all connections with proper thimbling and connectors. Legrand (DX^3) Cat No.408702 and equivalent Make of Seimens (Betagard 5SL4) /Schneider
Supply and fixing in replacement of unsv MCB DP 63 Amps 10 KA C Curve including making all connections with proper thimbling and connectors. Legrand (DX^3) Cat No.408620 and equivalent Make of Seimens (Betagard 5SL4)/Schneider
Supply and fixing in replacement of unsv MCB DP 40 Amps 10 KA C curve including making all connections with proper thimbling and connectors. Legrand (DX^3) Cat No.408618 and equivalent Make of Seimens (Betagard 5SL4)/Schneider
Supply and fixing in replacement of unsv MCB DP 32 Amps 10 KA C curve including making all connections with proper thimbling and connectors. Legrand (DX^3) Cat No.408617 and equivalent Make of Seimens (Betagard 5SL4)/Schneider
Supply and fixing in replacement of unsv MCB SP 6 to 30 Amps 10 KA C curve including making all connections with proper thimbling and connectors. Legrand (DX^3) and equivalent Make of Seimens (Betagard 5SL4)/Schneider
Supply and fixing in replacement of unsv MCB DP enclosure. Legrand Cat Part No 507791 and equvalent Seimens (Betagard 8GB32)/Schneider
Supply and fixing in replacement of unsv MCB SP enclosure. Legrand Cat Part No 507790 and equvalent Seimens (Betagard 8GB32)/Schneider
Supply and fixing in replacement of copper cable 10 sqmm multistranded including thimbels and connectors where ever required for rewiring of panels as directed by Engr-in-Charge
Demolition of Cement concrete (unreinforced) in four pole/two pole/HT& LT pole/panel/approach path to sub station n. exc 15 cm thickness (below or above ground level) and removing all the demolished material outside cantt area
PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate infour pole/two pole/HT& LT pole/panel/approach path to sub station as directed by Engr-in-Charge
Dismentiling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning in renewal of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- .Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing). (a) 01 set of 600 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts.
Dismentiling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning in renewal of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing). (a) 01 set of 200 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 25 KA at 415 volts.
Dismentiling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning in replacement of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing). (a) 01 set of 600 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts.
Dismentiling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning in replacement of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing). (a) 01 set of 600 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts.
Dismentling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning in replacement of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing) (a) 01 set of 250 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts.
Dismentiling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning in replacement of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- .Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing). (a) 01 set of 250 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 25 KA at 415 volts.
Dismentiling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning in replacement of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- .Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing). (a) 01 set of 400 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts.
Supply and fixing in replacement of LED 1x30 watt bulbs, 6500K Cool day light Lumen 2700 working voltage 220 -240 V suitable for B22, PF > 8.5 or above and as directed by Engr-in-Charge. Make Crompton/Havells/Philips
Supply and fixing in replacement of LED 1x45 watt bulbs, 6500K Cool day light Lumen 2700 working voltage 220 -240 V suitable for B22, PF > 8.5 or above and as directed by Engr-in-Charge. Make Crompton/Havells/Philips
Supply and fixing in replacement of Contactor MO C3. Make L&T/Seimens/Schneider
Supply and fixing in replacement of Contactor MO C5. Make L&T/Seimens/Schneider
Supply and fixing in replacement of Contactor MO C10. Make L&T/Seimens/Schneider
Supply and fixing in replacement of Contactor MO C15. Make L&T/Seimens/Schneider
Supply and fixing in replacement of Contactor MO C20. Make L&T/Seimens/Schneider
Supply and fixing in replacement of Digital Panel meter Current sec 0.05-5A/5A/1A. Frequency range 40-70 hzs 12 stage . Make L&T (etaSMART) Cat Part No CS90902OOOO and equivalent of Seimens/Schneider
Supply and fixing in replacement of Digital Panel meter Current sec 0.05-5A/5A/1A. Frequency range 40-70 hzs 16 stage . Make L&T (etaSMART) Cat Part No CS90902OOOO and equivalent of Seimens/Schneider
Supply and fixing in replacement of MCB TP 6A C Curve in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of MCB TP 10A C Curve in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of MCB TP 20AC Curve in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of MCB TP 40A C Curve in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of APP Technology 1 Kvar Standard duty Capacitor in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of APP Technology 2 Kvar Standard duty Capacitor in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of APP Technology 5 Kvar Standard duty Capacitor in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of APP Technology 10 Kvar Standard duty Capacitor in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Disconnecting LT supply from panel/ pole and reconnecting LT supply and testing complete. Locating the fault through cable fault locating machine to pin point the exact location of the fault lenth cable (100rm to 500rm) complete all as specified and directed by engr - in - charge.
Supply & fixing in replacement of Change over switch 63 Amp of onload change over switch 415V AC, 4 pole front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc of required capacity Make C&S/L&T/Havells/Indo-asian
Description all as per srl item No 54 but Change over switch 100 Amp
Description all as per srl item No 54 Change over switch 160 Amp
Description all as per srl item No 54 Change over switch 200 Amp
Description all as per srl item No 54 Change over switch 250 Amp
Description all as per srl item No 54 Change over switch 400 Amp
Supply & fixing in replacement of Change over switch 32 Amp of unsv automatic change over switch 240V AC, single phase front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc of required capacity Make : Havells/C&S/L&T
Description all as per srl item No 60 Change over switch 63 Amp
M/S S K Electricals Regd
Kay Bee Traders
M/S ASHOK KUMAR SURI
CELMAC REGD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .