| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹20.3 L+₹8,420 (0.42%)Admitted-Finance 0 DHANA TEJA BARARI DHANA TEJA MATHURA MATHURA UTTAR PRADESH 281005 | MATHURA | UTTAR PRADESH | 281005 | L2 | Admitted-Finance | |
| 3 | L3₹20.4 L+₹21,740 (1.08%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s S.K. CONSTRUCTION L2 | K MAA ENTERPRISES L1 | SUNEEL KUMAR VERMA L3 |
|---|---|---|---|---|---|---|
| 1.00 | Complete overhauling of 11 KV VCB | 92 | nos | 4,510 ₹4,14,920 | 4,480 ₹4,12,160 Lowest | 4,550 ₹4,18,600 |
| 2.00 | Attending Fault occurred in mechanism for smooth operation for tripping of breaker including setting aligment of trolly with panel of Breaker | 92 | nos | 3,010 ₹2,76,920 | 2,990 ₹2,75,080 Lowest | 3,050 ₹2,80,600 |
| 3.00 | Complete Repairing/Reconditioning of Tripping Coil of 11 KV VCB | 27 | nos | 3,000 ₹81,000 Lowest | 3,000 ₹81,000 Lowest | 3,050 ₹82,350 |
| 4.00 | Complete Repairing/Reconditioning of Closing Coil of 11 KV VCB | 27 | nos | 2,800 ₹75,600 Lowest | 2,800 ₹75,600 Lowest | 2,900 ₹78,300 |
| 5.00 | Repairing/Reconditioning of JAW/Crocodial/Cublic Type contact of 11 KV VCB | 15 | nos | 7,480 ₹1,12,200 | 7,450 ₹1,11,750 Lowest | 7,500 ₹1,12,500 |
| 6.00 | Complete Repairing/Reconditioning of Auxilliary Contact of 11 KV VCB | 15 | nos | 12,490 ₹1,87,350 Lowest | 12,500 ₹1,87,500 | 12,500 ₹1,87,500 |
| 7.00 | Complete Repairing and Reconditioning and replacement of Tripping Coil/Closing coil assembly and Plunger assembly as Required. | 20 | nos | 6,020 ₹1,20,400 | 6,000 ₹1,20,000 Lowest | 6,000 ₹1,20,000 Lowest |
| 8.00 | Complete Repairing/Reconditioning of ON/OFF Remote switch of 11 KV VCB | 20 | nos | 2,600 ₹52,000 Lowest | 2,620 ₹52,400 | 2,680 ₹53,600 |
| 9.00 | Repairing of plug & socket by replacement of burnt wire, HRC fuse. | 20 | nos | 1,990 ₹39,800 Lowest | 2,000 ₹40,000 | 2,000 ₹40,000 |
| 10.00 | Replacement of defective/ damaged CT by new CT with all its accessories & proper fixing in 11 KV breaker. (CT will be provided by the department.) | 20 | nos | 3,970 ₹79,400 | 3,950 ₹79,000 Lowest | 4,000 ₹80,000 |
Tender Value
Refer Docs
EMD Value
₹20,500
Closing Date
11 Jul 2025, 12:00 pmClosed
SUPERINTENDING ENGINEER, EDC-LUCKNOW RURAL, AMAUSI
SUPERINTENDING ENGINEER, EDC-LUCKNOW RURAL, AMAUSI
Repairing, Overhauling work of 11 KV Incoming and Outgoing VCB installed at 33/11 KV Sub Station Nadarganj New/Old, Utrethiya New/Old, Ambedkar University, Gehru, Bani, Sharda Nagar Under Jurisdiction of E.E. EDD.-Nadarganj, Amousi Zone, Lucknow
2025_MVVNL_1024606_3
83/EDC-(Lucknow Rural)/24-25
Open Tender
Electrical Works
Item Rate
180 days
LUCKNOW
AS PER TENDER DOCUMENT
2 documents required · 2 mandatory
₹3,540
E.E., EDD, CESS-Ist, LESA, Lucknow
₹20,500
26 Aug 2025
5 Jul 2025
11 Jul 2025
5 Jul 2025
11 Jul 2025
5 Jul 2025
Amount
Complete overhauling of 11 KV VCB
Attending Fault occurred in mechanism for smooth operation for tripping of breaker including setting aligment of trolly with panel of Breaker
Complete Repairing/Reconditioning of Tripping Coil of 11 KV VCB
Complete Repairing/Reconditioning of Closing Coil of 11 KV VCB
Repairing/Reconditioning of JAW/Crocodial/Cublic Type contact of 11 KV VCB
Complete Repairing/Reconditioning of Auxilliary Contact of 11 KV VCB
Complete Repairing and Reconditioning and replacement of Tripping Coil/Closing coil assembly and Plunger assembly as Required.
Complete Repairing/Reconditioning of ON/OFF Remote switch of 11 KV VCB
Repairing of plug & socket by replacement of burnt wire, HRC fuse.
Replacement of defective/ damaged CT by new CT with all its accessories & proper fixing in 11 KV breaker. (CT will be provided by the department.)
Providing and fixing of door close handies.
Replacement of defective/ damaged V.I. by new Vaccum intrupter with all its accessories & proper fixing in 11 KV breaker. (V.I. will be provided by the department.)
Repairing/Reconditioning of spring charging assembly, replacement of damage charging gear, ratchet type roller bearing including replacement of damage bush, nuts and washer.
Opening of complete 11 K.V. Bus bar in case of emergency breakdown its cleaning with carbon tetra chloride and rebolting and replacement of damage Nuts & Bolt if required.
In case of emergency breakdown V.C.B. repairing etc. Work like cleaning and reffitting after removal of fault.
Attending breakdown of control panel wiring due to short circuit or any mishappening including removal of fault & rewiring of wires & proper checking its all function for making system in healthy condition.
G.S.T. Extra as per Rules.
M/s S.K. CONSTRUCTION (BID ID -5313314)
SUNEEL KUMAR VERMA (BID ID -5313403)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
Tender Document • 1.29 MB
T83FORM.pdf
Tender Document • 1.32 MB
BOQ_1918909.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .