Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.7 LAccepted-AOC | 1 | Accepted-AOC being lowest | |
| 2 | 2₹5.4 L+₹1.7 L (46.1%)Rejected-Finance | 2 | Rejected-Finance being not lowest |
Tender Value
₹4 L
EMD Value
₹8,000
Closing Date
30 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF JAIPUR
AGE I AF JAIPUR OPP JALMAHAL AMER ROAD
REPAIRS TO CERTAIN SEWAGE LINES, MAN HOLES, DRAIN ETC. IN DOMESTIC ANDTECH AREA AT AIR FORCE STATION JAIPUR
2022_MES_535415_1
8401/E8
Open Tender
Civil Works - Others
Item Rate
270 days
AGE I AF JAIPUR
Class E and above and category a (ii)
8 documents required · 8 mandatory
₹500
AGE I AF JAIPUR
₹8,000
Yes
4 Aug 2022
2 Jul 2022
1 Aug 2022
2 Jul 2022
30 Jul 2022
16 Jul 2022
2 Jul 2022 - 10 Jul 2022
Amount
Demolition of Brick work of stone/boulder masonry, built in cement mortar excluding ashlars facing dressed stone work and pre-cast concrete.all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.50 meter wide or not exceeding 10 square meters in plan area and not exceeding 1.50 meter in depth for foundation in any type of soil and getting out complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches exceeding 1.50 meter wide or not exceeding 10 square meters in plan area and not exceeding 3.0 meter in depth for foundation in any type of soil and getting out complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading, levelling watering and well ramming in layers not exc. 25 cm using excavated soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed by Engineer-in-Charge.
M&LBrickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
M&LBrickwork with subclass `B' bricks, in half brick wall straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
Demolition and breaking up drain pipes 150 mm dia (salt glazed ware AC or reinforcement concrete set in cement mortar all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes 100 mm dia (salt glazed ware AC or reinforcement concrete set in cement mortar all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate for 150 mm dia bore drain pipe for bed concrete including packing under and hunching against the sides of pipe after they are laid and tested complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate for 100 mm dia bore drain pipe for bed concrete including packing under and hunching against the sides of pipe after they are laid and tested complete all as specified and directed by Engineer-in-Charge.
M&L 150 mm Salt-glazed stoneware drain pipes laid in trenches and jointed as specified and directed by Engineer-in-Charge.
M&L 100 mm Salt-glazed stoneware drain pipes laid in trenches and jointed as specified and directed by Engineer-in-Charge.
M&L rendering 15 mm thick on fair faces of brick masonry surface other than fair faces of brick work in CM 1:6 all as specified and directed by Engineer-in-Charge.
M&L TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10 mm dia and above, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) in any description & in any position not otherwise specifically provided for and removing debries out of MD land all as specified and directed by Engineer-in-Charge.
M&L for precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, shelves and similar articles with plain faces, set in CM 1:4, including necessary form work moulds etc all as specified. (Reinforcement shall be measured and paid for separately).
Demolition of cement Concrete(un-reinforced) in any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D-2, using 40mm graded aggregates as in sub base.
M&L for chequered cement concrete tiles 30cmx30cmx25 mm thick , with grey cement and pigment, set, jointed and pointed in neat cement slurry in floors over and including 15 mm thick screed bed in CM 1:6 all as specified and directed by Engineer-in-Charge.
Supply and spreading fine aggregate (sand) for sand cusioning to receive interlocking tile , complete all as specified and directed all as specified and directed by Engineer-in-Charge.
M&L machine pressed precast coloured Interlocking paver block / tiles any shape and size 60 mm thick confirming to IS- 15658-2006 of M-35 grade chemically treated rubber moulded complete all as specified and directed all as specified and directed by Engineer-in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L Non Skid ceramic coloured tiles of size 300X300mm and 7 to 8mm thick in floors over and including 15mm thick screed bed in cm 1:6 etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade
M&L Glazed coloured ceramic jointless tiles 450mmx300mmx7mm thick on vertical surfaces such as skirting, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match complete over & including 10 mm thick cement plaster in CM 1:4 all as specified
Dismantling cast iron work of any description
S&F 100mm Cast Iron sanitary connection socket to fit WC out let.
S&F Cast Iron nahani trap, 75 mm dia of outlet, with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4).
S&F Cast Iron floor trap, 75 mm dia of outlet, with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4).
S&F 75 mm bore Cast Iron, sand cast, soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors.
All as per item No. 31 above but 100mm bore.
S&F 100 mm bore cast iron, sand cast pipes, soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls.
All as per item No. 33 above but 75 mm bore.
S&F stack clamps, for 110 mm bore pipe, out of 50x5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof.
All as per item No. 35 above but for 75mm bore pipe.
S&F 75 mm bore Cast Iron bends (any radius), diminishing pieces or tapers (larger bore measured).
S&F 100 mm bore Cast Iron bends (any radius), diminishing pieces or tapers (larger bore measured).
S&F 100 mm bore Cast Iron bend (any radius) with duck’s foot or heel rest.
S&F in repair Cast Iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches for 110 mm bore pipe.
S&F Cast Iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches for 75 mm bore pipe.
S&F in repair 110mm Cast Iron junction (Single `T').
S&F in repair 75mm Cast Iron junction (Single `T').
S&F in repair 110mm Cast Iron `P' trap complete all as specified and directed.
S&F precasted reinforced concrete man hole cover medium duty along with frame not exc 0.70 sqm all as specified & directed.
M&L for cleaning pipe lines 150mm dia by rodding from Man holes and well flushing with water after cleaning all as specified & directed. Note :- Contractor shall depute his supervisor to collect complaint from JE office at 9.00am to 5.30pm & after cleaning the line get checked from JE. Complaint of blockages should be completed within 24 hrs, if the same is not attended, a recovery of Rs 500/- per complaint shall be made.
All as per item No. 46 above but 100 mm bore.
Cleaning of Nahani Trap of bath room, kitchen by rodding blockage including taking down/refixing of grating etc complete all as specified and directed by Engineer-in-Charge. Note :- Contractor shall depute his supervisor to collect complaint from AGE(B/R)-II office at 9.00am to 5.30pm & after cleaning the line get checked from Engineer-in-Charge. Complaint of blockages should be completed within 24 hrs, if the same is not attended, a recovery of Rs 250/- per complaint shall be made.
Cleaning of gully trap of bath room, kitchen by rodding blockage including taking down/refixing cover complete all as specified and directed by Engineer-in-Charge. Note :- Contractor shall depute his supervisor to collect complaint from AGE(B/R)-II office at 9.00am to 5.30pm & after cleaning the line get checked from Engineer-in-Charge. Complaint of blockages should be completed within 24 hrs, if the same is not attended, a recovery of Rs 250/- per complaint shall be made.
Cleaning Indian type WC/ Europion type WC by rodding/ pumping by hand including taking out door/refixing of over access covers etc complete all as specified and directed by Engineer-in-Charge. Note :- Contractor shall depute his supervisor to collect complaint from JE(Civ) office at 9.00am to 5.30pm & after cleaning the line get checked from JE. Complaint of blockages should be completed within 24 hrs, if the same is not attended, a recovery of Rs 250/- per complaint shall be made.
Cleaning of manholes of size n.exc 1.00 sqm plan area (internal) and n.exc 1.00 m depth from GL including removal of manhole covers carefully, cleaning of sludge etc and refixing the manhole covers with cement mortar (1:4) (Sludge shall be removed outside MD land) all as directed.
M&L for cleaning of septic tanks and removal of sludge and water in covered containers and carry out side MD land immediately all as specified and directed by Engineer-in-Charge. Note :- (i) Mode of measurement of sludge quantity shall be the depth of sludge actually measured at site. (ii) Sludge shall be removed outside the MD land.
S & F in repair Vitreous China squatting pan, of ‘Orissa pattern ‘ white of size 580 X 440 mm, with integral foot rests and 'P' or 'S' trap including provision of lime concrete bedding minimum 150 mm thick (1 lime, 2 sand or surkhi and 5 aggregate) complete all as specified.
S& F in repair Vitreous China wash down water closet pan (pedestal pattern) incl seat cover complete all as specified.
S & F in repair PVC 10 ltrs , valveless, syphonic action type, flushing cistern, white, low level, with inlet, ball valve, float and handle, including 32 mm bore flush pipe brackets all as specified.
M&L water proofing treatment to RCC sunken slab, Rendering 15m thick in cement mortar 1:3 using water proofing compound on raised vertical surfaces after demolition of PCC, cleaning the surfaces with wire brush/coir brush, removing loose material like dust particles, dirt etc. Creating fillet covering of 50 x 50 mm with polymer modified mortar on the junction of slab and wall. Applying first coat of two component modified polmer coating on the horizontal and vertical surface upto 300mm above wall surfaces. Provision of polyester reinforced coated net of 45 g/m2. 2.50mm x 2.50mm immediately on aboe coating. Applying second coating of two component modified polymer coating after 72 hrs upto 300mm above wall surface. Laying concrete 1:4:8 over the coating as per requirement. Joining the sanitary pipes with the waterproofing tape having bridging ability of more than 1.5mm. Filling the gap between the wall opening and sanitary pipe with non shink cementatious grout as directed by Engineer-in-charge.
M&L for cleaning of Grease trap and removal of sludge and water in covered containers and carry out side MD land immediately all as specified and directed by Engineer-in-Charge. Note :- (i) Mode of measurement of sludge quantity shall be the depth of sludge actually measured at site. (ii) Sludge shall be removed outside the MD land.
M/S ROHIT CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .