Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.7 L+₹3.2 L (7.24%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹49.1 L+₹4.6 L (10.4%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹50.0 L+₹5.5 L (12.3%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹47.7 L
EMD Value
₹95,500
Closing Date
13 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Kapurthala
Kapurthala
Provn of automatic power factor corrector pannels at various location at Suranussi under GE Kapurthala.
2022_MES_526198_1
GE KPT- /2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Kapurthala
As per Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE Kapurthala
₹95,500
Yes
12 Aug 2022
25 May 2022
15 Jun 2022
25 May 2022
13 Jun 2022
26 May 2022
60 days
Amount
Supply, install, testing and commissioning of LT, Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 40 KVAR with incoming MCCBs, CPRI approved, weather/vermin proof, as per IS specification CRCA sheet, factory assembled modular and non compartmentalized construction, outdoor type, with front side hinged double door with locking arrangement, floor mounted free standing type, duly powder coated, with Al Bus Bars 200 Amps and Multistrand copper cables of appropriate size for each feeder of with 8-step APFC Relay comprising of following and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above gorund level,complete all as specified and as directed by Engineer-in-Charge.:- Make of Panel : Siemens/ L&T/Legrand/ABB (i) MCCB, Thermal Magnetic type, 160 Amp, 3 Pole, 25 KA. Make : Siemens/ Legrand/ABB/L&T. (ii) MD-XL capacitor 440V rating, heavy duty capacitor switching contractor: (a) 5 kVAR with 10kA MCB & Capacitor duty contactor - 1 No. (b) 10 KVAR with 10kA MCB & Capacitor duty contactor - 2 Nos. (c) 15 KVAR with 10kA MCB & Capacitor duty contactor - 1 No. (iii) Microprocessor based intelligent power factor 8-Step relay with RS485 Port. Make : ABB/Siemens/ L&T/Legrand (iv) CONTROL COMPONENTS: (a) CTR: 200/5A CL: 1, 5VA -3Nos. (b) Digital Multi meter to measure Volt, amps and PF - 1No. (c) Indication Lamps for RYB (LED Type) - 3Nos. (d) Out going Indication Lamps (LED Type) - ON/OFF - 8 Nos.
Supply, install, testing and commissioning of LT, Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 60 KVAR with incoming MCCBs, CPRI approved, weather/vermin proof, as per IS specification CRCA sheet, factory assembled modular and non compartmentalized construction, outdoor type, with front side hinged double door with locking arrangement, floor mounted free standing type, duly powder coated, with Al Bus Bars 300 Amps and Multistrand copper cables of appropriate size for each feeder of with 8-step APFC Relay comprising of following and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above gorund level, complete all as specified and as directed by Engineer-in-Charge.:- Make of Panel : Siemens/ L&T/Legrand/ABB (i) MCCB, Thermal Magnetic type, 200 Amp, 3 Pole, 25 KA. Make : Siemens/ L&T/Legrand/ABB. (ii) MD-XL capacitor 440V rating, heavy duty capacitor switching contractor: (a) 5 kVAR with 10kA MCB & Capacitor duty contactor - 2 Nos. (b) 10 KVAR with 10kA MCB & Capacitor duty contactor - 2 Nos. (c) 15 KVAR with 10kA MCB & Capacitor duty contactor - 2 Nos. (iii) Microprocessor based intelligent power factor 8-Step relay with RS485 Port. Make : ABB/Siemens/ L&T/Legrand (iv) CONTROL COMPONENTS: (a) CTR: 200/5A CL: 1, 5VA -3Nos. (b) Digital Multi meter to measure Volt, amps and PF - 1No. (c) Indication Lamps for RYB (LED Type) - 3Nos. (d) Out going Indication Lamps (LED Type) - ON/OFF - 8 Nos.
Supply, install, testing and commissioning of LT, Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 100 KVAR with incoming MCCBs, CPRI approved, weather/vermin proof, as per IS specification CRCA sheet, factory assembled modular and non compartmentalized construction, outdoor type, with front side hinged double door with locking arrangement, floor mounted free standing type, duly powder coated, with Al Bus Bars 350 Amps and Multistrand copper cables of appropriate size for each feeder of with 8-step APFC Relay comprising of following and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above gorund level,complete all as specified and as directed by Engineer-in-Charge :- Make of Panel : Siemens/ L&T/Legrand/ABB (i) MCCB, Thermal Magnetic type, 250 Amp, 3 Pole, 35 KA. Make : Siemens/ L&T/Legrand/ABB. (ii) MD-XL capacitor 440V rating, heavy duty capacitor switching contractor: (a) 5 KVAR with 10kA MCB & Capacitor duty contactor - 2 Nos. (b) 10 KVAR with 10kA MCB & Capacitor duty contactor - 1 No. (c) 15 KVAR with 10kA MCB & Capacitor duty contactor - 2 Nos. (d) 25 KVAR with 10kA MCB & Capacitor duty contactor - 2 Nos. (iii) Microprocessor based intelligent power factor 8-Step relay with RS485 Port. Make : ABB/Siemens/ L&T/Legrand. (iv) CONTROL COMPONENTS: (a) CTR: 200/5A CL: 1, 5VA -3 Nos. (b) Digital Multi meter to measure Volt, amps and PF - 1 No. (c) Indication Lamps for RYB (LED Type) - 3 Nos. (d) Out going Indication Lamps (LED Type) - ON/OFF - 8 Nos.
Supply, install, testing and commissioning of LT, Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 120 KVAR with incoming MCCBs, CPRI approved, weather/vermin proof, as per IS specification CRCA sheet, factory assembled modular and non compartmentalized construction, outdoor type, with front side hinged double door with locking arrangement, floor mounted free standing type, duly powder coated, with Al Bus Bars 450 Amps and Multistrand copper cables of appropriate size for each feeder of with 8-step APFC Relay comprising of following and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above gorund level, complete all as specified and as directed by Engineer-in-Charge. :- Make of Panel : Siemens/ L&T/Legrand/ABB (i) MCCB, Thermal Magnetic type, 320 Amp, 3 Pole, 35 KA. Make : Siemens/ L&T/Legrand/ABB. (ii) MD-XL capacitor 440V rating, heavy duty capacitor switching contractor: (a) 5 kVAR with 10kA MCB & Capacitor duty contactor - 1 No (b) 10 KVAR with 10kA MCB & Capacitor duty contactor - 1 No (c) 15 KVAR with 10kA MCB & Capacitor duty contactor - 2 Nos. (d) 25 KVAR with 10kA MCB & Capacitor duty contactor - 3 Nos. (iii) Microprocessor based intelligent power factor 8-Step relay with RS485 Port. Make : ABB/Siemens/ L&T/Legrand (iv) CONTROL COMPONENTS: (a) CTR: 200/5A CL: 1, 5VA -3Nos. (b) Digital Multi meter to measure Volt, amps and PF - 1No. (c) Indication Lamps for RYB (LED Type) - 3Nos. (d) Out going Indication Lamps (LED Type) - ON/OFF - 8 Nos.
Supply, install, testing and commissioning of LT, Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 150 KVAR with incoming MCCBs, CPRI approved, weather/vermin proof, as per IS specification CRCA sheet, factory assembled modular and non compartmentalized construction, outdoor type, with front side hinged double door with locking arrangement, floor mounted free standing type, duly powder coated, with Al Bus Bars 600 Amps and Multistrand copper cables of appropriate size for each feeder of with 12-step APFC Relay comprising of following and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above gorund level, complete all as specified and as directed by Engineer-in-Charge :- Make of Panel : Siemens/ L&T/Legrand/ABB (i) MCCB, Thermal Magnetic type, 400 Amp, 3 Pole, 35 KA. Make : Siemens/ L&T/Legrand/ABB (ii) MD-XL capacitor 440V rating, heavy duty capacitor switching contractor: (a) 5 kVAR with 10kA MCB & Capacitor duty contactor - 1 No. (b) 10 KVAR with 10kA MCB & Capacitor duty contactor - 1 No. (c) 15 KVAR with 10kA MCB & Capacitor duty contactor - 4 Nos. (d) 25 KVAR with 10kA MCB & Capacitor duty contactor - 3 Nos. (iii) Microprocessor based intelligent power factor 12-Step relay with RS485 Port. Make : ABB/Siemens/ L&T/Legrand. (iv) CONTROL COMPONENTS: (a) CTR: 200/5A CL: 1, 5VA -3Nos. (b) Digital Multi meter to measure Volt, amps and PF - 1No. (c) Indication Lamps for RYB (LED Type) - 3 Nos. (d) Out going Indication Lamps (LED Type) - ON/OFF - 09 Nos.
Supplying, Laying and Jointing testing and commissioning XLPE UG cable, sheathed armoured LT 1100 grade heavy duty with Stranded aluminum conductor through pipes in ducts. Poles/ trenches incl fixing of copper lugs, making good to disturbed surface etcof size 3.5 core 95 sqmm complete all as specified and as directed by Engineer-in-Charge. Note : Excavation and earth work to be measured and paid separately. Make :- CCI/Finolex/Havells/Polycab.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth ,and getting out in soft/loose sil for laying if GI pipe etc complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed by Engineer-in-Charge.
Supply and fix common burnt clay building bricks Sub class B designation 75 complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for earthing complete with copper earth plate electrode 600mmx600mmx 3.15 mm thick buried directly in gournd (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to copper strip of size 20x3mm as earthing lead upto 7.5 mtrs from testing point fixed by means of steel bolts, nuts, check nuts and washer, of galvanized earth wire protected by 25mm bore medium grade galvanised iron pipe and other end connected to earthing test point including funnel with watering pipe of 20mm bore light grade galvanised iron, wire mesh, charcoal or coke and common salt in alternate layer of 15cm (Compacted thickness) all around earth electrode with concrete earth pit in PCC (1:3:6) type C-1 50mm thick precast RCC M-20 nominal mix cover slab of size 450mm x 450mm reinforced with 8mm dia TMT bar 10 cm C/C and suitable handle of 10mm dia round bar including necessary execavation, earth work in soft / loose soil and deposited soil to a distance n.exc 50 M and necessary testing complete all as shown in electrical plate No. 3 of MES shedule of SSR Part-I complete all as specified and as directed by Engineer-in-Charge.
Aziz Traders
kailu construction co
Gurjit const co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .