| 3 | L3₹64.1 L+₹5.0 L (8.49%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical 1 532 1 AMMAN TOWER ENGINEER NAGAR 3RD FLOOR 8TH STREET MADURAI NORTH THIRUPPALAI MADURAI 625014 | MADURAI | TAMIL NADU | 625014 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹59.1 L
EMD Value
₹59,117
Closing Date
7 Nov 2023, 3:00 pmClosed
Commissiner Madurai Corporation
Aringar anna maligai
Construction of Additional Building at Kodikulam UPHC Hospital in Ward No 10
2023_MAWS_378102_1
E6 / EST.11935C/2023
Open Tender
Civil Works
Lump-sum
60 days
Madurai
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹59,117
28 Dec 2023
13 Oct 2023
7 Nov 2023
13 Oct 2023
7 Nov 2023
13 Oct 2023
Amount
Earth work excavation in all kinds of soils except hard rock requiring blasting, inclusive of shoring, strutting and baling out water wherever necessary refilling the sides of foundation with excavated earth in layers of 15cm thick well rammed and consolidated depositing the surplus earth within compound in places as shown by the deptl.officers, clearing and leveling the site with initial lead of 10M and lift of 2M etc.Comp.SI.No.62-rate for 10m3 MDU-CORP-BUILDING DATA-P-25
Supplying and filling in foundation and basement with Quary Dust in layers of 15cum thick well rammed and consolidated including watering complying with std. specification etc. MDU-CORP-BUILDING DATA-P-27
Cement concrete 1:4:8 (one cement four sand and eight aggregates) Using 40mm gauge hard broken granite jelly for foundation inc. consolidation and dewatering for foundation wherever necessary etc.complete. MDU-CORP-BUILDING DATA-P-28
Plain Cement Concrete 1:2:4 (one cement,two fine aggregates and four coarse aggregates) using 20mm size ISSHBG metal including cost and conveyance of all materials to site and including for the mixing,laying and labour charge setc.,complete as per standard specification.MDU-CORP-BUILDING DATA-P-27
Supplying and erecting shuttering with necessary supports for plith beam with all cross brancings etc.., complete (Rcc coloumn footing plinth beam and lintel sides) MDU-CORP-BUILDING DATA-P-31
Supplying and erecting centering for sides soffits and strutting for plain surface such as dreainforced cement concrete columns boxing (for Rectangular or Square columns) top and bottom slabs, sunshades with necessary facia with all cross bracings etc., complete in all floors or any height (the retrieved materials should be taken back by the contractor) using steel plates (Vertical Poration) MDU-CORP-BUILDING DATA-P-31
Supplying, erecting STEEL CENTERING for sides and soffits inc supports and strutting for plain surface such an reinforced cement concrete slas prectangualar beams tee or el beams lintels, bed blocks staircase in all floors of any height (the retrived materials should be taken back by the contractor) the payment for cenetering shall be given by the concrete is laid (bottom only) MDU-CORP-BUILDING DATA-P-31
Reinforced cement concrete 1:1 1/2 :3 (One cement One and half sand and three aggregate) using 20 mm machine broken gauge bard granite jelly for RCC works the rate excluding the cost of reinforcement grills, centering and shuttering etc., complete in G.F MDU-CORP-BUILDING DATA-P-32
Suppling and fabricating and placing in position MS (or) R.T.S.bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors..MDU-CORP-BUILDING DATA-P-39
Brick work in CM 1:5 (One cement and five sand) using country bricks of size 8 3/4"X4 1/2"X2" including curing etc., complete For Foundation and Basement.MDU-CORP-BUILDING DATA-P-41
Brick work in CM 1:5 (One cement and five sand) using country bricks of size 8 3/4"X4 1/2"X2" including curing etc., complete For Super Structure in Ground Floor.MDU-CORP-BUILDING DATA-P-41
Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.P.No-26
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges offrame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work. PWD P.No-70
Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
Supplying and fixing in position of alulminium Anodised Partition with 62x38x2mm extruded box section at bottom vertical and horizontal members. The vertical member are spaced at 90cm c/c and to horizontal members are spaced at 1.2M, 2.1M and 2.4M height the bottom panels should be covered with 12mm thick PLB exterior grade and the top and middle panels should be fixed at 4mm thick glass thick glass necessary glassing clips, rupper beading etc, including necessary dismantling holes in RCC colums beams masonry wherever necessary with power drill it the extent required and made good to the original conditions after fixing as dricted by the departmental officers. All Aluminium section should be anodised to 1.5microns as per ISI..MDU-CORP-BUILDING DATA-P-104
Plastering with CM1:5(one cement and five sand) 12mm thick 1m2.MDU-CORP-BUILDING DATA-P-46
Plastering with CM1:3(one cement and three sand) 10mm thick 1m2.MDU-CORP-BUILDING DATA-P-42
Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar1:3 (one cemen tthree sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on workMDU-CORP-BUILDING DATA-P-52
Dadooring the sides of wall with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over abase layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid with out any air gap in the tiles neatly and fixing in position as per standard specifications.MDU-CORP-BUILDING DATA-P-53
Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification.-10 sq.m.MDU-CORP-BUILDING DATA-P-62
Weathering Course with Concrete Broken Brick (S.I.No.278) & (P&D) Data54.Jelly 20mm gauge in pure slaked lime (nos and to be added) over roof slab,the proportion of brick jelly to lime being'32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cumMDU-CORP-BUILDING DATA-P-46
Finishing the top of roof with one course of machine pressed tiles of size 200mm x 200mm x 20mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weigh to fcement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete MDU-CORP-BUILDING DATA-P-47
Supply and delivery and fixing of G.I. Pipes and specials as per IS Specification. 110mm PVC. Pipe 4kc
110mm PVC. Tee
110mm PVC. Bend
32 mm PVC. Pipe
32 mm GI. Pipe
32 mm GI. Coupling
32 mm GI. Elbow
32 mm GI.Tee
32 mm GI.Bend
25 mm PVC. Pipe
Construction of inspection chambers of following sizes with earth work excavation for foundation with Dust Filling 10mm thick and Plain cement concrete bed in C.M. 1:5:10 using 40mm HBG jelly 10mm thick for foundation, 23cm thick brick wall work in C.M. 1:5 for chambers, Inner and Outer Plastering with C.M. 1:3 12mm thick, benching, channelling, 75mm thick RCC loose slab covering in C.M. 1:2:4 mix using 20mm blue granite jelly including necessary reinforcement, etc., complet MDU-CORP-BUILDING DATA-P-97
Supplying and fixing in position white glazed European Water closet of best quality and approved make with 100mm 'P' os 'S" trap with double flapped rigit PVC seat cover with CP brass hinges with 12.5 liters PVC Low lwvwl flusing tank with all internal fittings etc., complete complying with standard specifications, labor inclusive of fixing low level flushing tank.MDU-CORP-BUILDING DATA-P-69
Supplying and fixing in position best quality approved make white glazed earthen ware wash hand basin of size 550X400mm with a pair of castiron bracket, including cost of 15mm dia metre brass chromium plated piller tape, 32mm dia metre C.P. Waste union, 32mm dia metre P.V.C. waste pipe with rubber plug and chain, 15mm dia metre G.M. wheel valve, 15mm dia brass nipple, 15mm dia nylon connection setc., including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and paintiung the brackets with two coats of paint over a primimg coat of anticorrosive paint including testing for leackage etc., complete complying with standard specifications.MDU-CORP-BUILDING DATA-P-67
Supplying and fixing in position indian make bewelled edge mirror of approved quality and brand of size 600X450mm with necessary plastic back, PVC frame with bottom stand of approved colour with brass screws, rawal plugs etc.,complete complying with standard specifications.MDU-CORP-BUILDING DATA-P-73
Supplying and fixing best approved quality Brass C.P/Alanodised Towel rail 600mm. Long and 20mm Diameter with brackets of same materia lincluding cost of Teak-Wood plugs and C.P.Screws etc.,complete complying with standard specifications Brass C P Towel Rails.MDU-CORP-BUILDING DATA-P-73
Supply and fixing HDPE tank 1000Liters.
SUPPLY & INSTALLATION OF AIR-CONDITIONER WITH COPPER COIL 1.5 TR Split Type AC Unit - 5 Star Rated (M-1984) PWD P.No-153
Supply and installation of 5 KVA capacity Automatic Voltage Stabilizer with time delay relay(M-1989)
Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit) (M-1990)
Supply and fixing of MS stand for fixing outdoor unit (M-1991)
Providing Rain Water Harvesting arrangements in corporation building by inserting of 150mm PVC slotted casing pipe, including earth work excavation for 900mm precost cement Ring 5nos filling with One,three,Fifth Rings are 40mm metal and Two and Fourth Rings are Sand providing necessary pipeline arrangements with std specification etc, completeMDU-CORP-BUILDING DATA-P-98
Supplying and laying Rubberised inter locking Paver block M40 grade 80mm thick high strength type conforming IS15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make tobe laid in flurring bone pattern with stone dust cushion below the uniform shap of approved nonskitting surface in the top and the rate including levelling the base preparation of pavers assub base,stone dust cushion150mm thick laying out of pavement cut the pieces to fix the edge vibring the pavers, sweeping tranporting loading unloading of laying paver block as per standard specification,.
Supply and run off 2 of 2.50sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (derived from SD 55)
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light (6 points per coil) (for rooms like bath, toilet & pumproom, etc.)(SD 26)
Supply and fixing of single box type 4'36W fluorescent fitting complete with electronic ballast with TW roundblocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting (SD87)
Supply and fixing of 1200mm (48")sweep AC ceiling fan complete with stepped electronic 300W regulator with the existing down rod on the existing clamps. (SD 110)
Supply and run off 2 of 4 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (derived from SD 57)
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements withnecessary masonry work and with 38mm RCC cover slab for the brick masonry (SD233)
Supply and run of 1 of No.8 SWG GI wire for earth connection (SD74)
Labour charges for over head wiring from EB pole to pumproom by fixing 32mm dia GI pipe to the required height over roof slab of pumproom and as directed by EB authorities including fixing M.S. clamp set, U.Kondi, 7/20 GI wire, 7/20 PVC insulated copper wire reels, T.W. meter board, aerial board, earth plate GI Bolt of nuts, PVC Hose fuse wiring etc. complete
Add GST 18%
MARUTHU CONSTRUCTIONS
C SIVAKUMAR
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .