Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAccepted-AOC FATEHABAD HGVY | FATEHGARH SAHIB | PUNJAB | 140402 | ₹3.0 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹3.1 Cr+₹8.9 L (2.93%)Rejected-AOC | ₹3.1 Cr+₹8.9 L (2.93%) | L2 | Rejected-AOC h |
| 3 | L3₹3.2 Cr+₹15.0 L (4.95%)Rejected-AOC 62A OFFICER COLONY AZAD NAGAR HISAR 125001 | HISAR | HARYANA | 125001 | ₹3.2 Cr+₹15.0 L (4.95%) | L3 | Rejected-AOC h |
| Sl No | Description | Qty | Unit | Shishpal Govt. Contractor L3 | SHREE RAM ENTERPRISES L1 | ABCD INDIA WORKS PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|
| 1.00 | Providing and fixing uPVC pipe conforming to IS:4985 (10 kg/sq cm) including all
fittings, This includes jointing of pipes and fittings with one step solvent cement,
trenching, refilling and testing of joints complete as per direction of Engineer in Charge
and as per layout.(Make..Supreme/Astral/Ashirvad) 110 mm.. | 40 | Rmt. | 1,650 ₹66,000 | 270 ₹10,800 Lowest | 1,450 ₹58,000 |
| 2.00 | Providing and fixing of signages of toilet of size 300x450mm as per design complete in all respect up to the entire satisfaction of Engineer-in-charge of the work..(Make: Patel Brothers , JMJ Signage , Vizan Sign). | 3 | Each | 5,300 ₹15,900 | 3,600 ₹10,800 Lowest | 4,500 ₹13,500 |
| 3.00 | Providing and fixing uPVC pipe conforming to IS:4985 (10 kg/sq cm) including all
fittings, This includes jointing of pipes and fittings with one step solvent cement,
trenching, refilling and testing of joints complete as per direction of Engineer in Charge
and as per layout.(Make..Supreme/Astral/Ashirvad) 40 mm | 13 | Rmt. | 400 ₹5,200 | 215 ₹2,795 Lowest | 300 ₹3,900 |
| 4.00 | Providing and fixing of stainless steel letters on taper wall as per the design and complete in all respet as per the direction of engineer in charge.
90 LETTERS X 16` HEIGHT = 1440 INCH | 1 | Each | 4,50,000 ₹4,50,000 | 3,08,000 ₹3,08,000 Lowest | 4,00,000 ₹4,00,000 |
| 5.00 | Supplying, Installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KVwith Short and Open circuit protection, THD ( 10%, P.F.=0.95, IP20, CRI )80, Flicker free, (flicker shouldbe below 5 %), life time (LED, Driver and electricalcircuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (EandM)-2025Colour Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete
in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size
and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
Powder coated die cast /Extruded aluminium Body (Thickness ) 1.20 mm)....24 -26watt | 41 | Each | 850 ₹34,850 | 570 ₹23,370 Lowest | 750 ₹30,750 |
| 6.00 | Supplying, Installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KVwith Short and Open circuit protection, THD ( 10%, P.F.=0.95, IP20, CRI )80, Flicker free, (flicker shouldbe below 5 %), life time (LED, Driver and electricalcircuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (EandM)-2025Colour Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size
and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
Powder coated die cast /Extruded aluminium Body (Thickness ) 1.20 mm)....40 watt | 176 | Each | 976 ₹1,71,776 | 550 ₹96,800 Lowest | 750 ₹1,32,000 |
| 7.00 | Deduct - Recovery of brick work | 26,649 | Nos. | 1 ₹-26,649 Lowest | 2.5 ₹-66,622.5 | 1.5 ₹-39,973.5 |
| 8.00 | Deduct - Recovery of Old IPB Tiles 80mm thick | 53,694 | Nos. | 1.5 ₹-80,541 Lowest | 6 ₹-3,22,164 | 2 ₹-1,07,388 |
Tender Value
₹2.9 Cr
EMD Value
₹5.8 L
Closing Date
9 Mar 2026, 5:00 pmClosed
SH ANIL MOHIL
Municipal Committee Barwala
CONSTRUCTION OF SHAMSHAN GHAT IN MC BARWALA
2026_HRY_505166_1
2026A22C66E4 4B1C 4AEC B374 BF42B23E17EE345ULB
Open Tender
Civil Works
Works
400 days
Barwala
CONSTRUCTION OF SHAMSHAN GHAT IN MC BARWALA
2 documents required · 2 mandatory
₹15,000
₹5.8 L
Yes
20 Apr 2026
25 Feb 2026
10 Mar 2026
25 Feb 2026
9 Mar 2026
25 Feb 2026
Providing and fixing uPVC pipe conforming to IS:4985 (10 kg/sq cm) including all fittings, This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge and as per layout.(Make..Supreme/Astral/Ashirvad) 110 mm..
Providing and fixing of signages of toilet of size 300x450mm as per design complete in all respect up to the entire satisfaction of Engineer-in-charge of the work..(Make: Patel Brothers , JMJ Signage , Vizan Sign).
Providing and fixing uPVC pipe conforming to IS:4985 (10 kg/sq cm) including all fittings, This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge and as per layout.(Make..Supreme/Astral/Ashirvad) 40 mm
Providing and fixing of stainless steel letters on taper wall as per the design and complete in all respet as per the direction of engineer in charge. 90 LETTERS X 16` HEIGHT = 1440 INCH
Supplying, Installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KVwith Short and Open circuit protection, THD ( 10%, P.F.=0.95, IP20, CRI )80, Flicker free, (flicker shouldbe below 5 %), life time (LED, Driver and electricalcircuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (EandM)-2025Colour Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness ) 1.20 mm)....24 -26watt
Supplying, Installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KVwith Short and Open circuit protection, THD ( 10%, P.F.=0.95, IP20, CRI )80, Flicker free, (flicker shouldbe below 5 %), life time (LED, Driver and electricalcircuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (EandM)-2025Colour Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness ) 1.20 mm)....40 watt
Deduct - Recovery of brick work
Deduct - Recovery of Old IPB Tiles 80mm thick
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
:CONSTRUCTION OF SHAMSHAN GHAT IN MC BARWALA
stage.html
html • 0.04 MB
techsummary_583889.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
BOQ_583889.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .