Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 CrAccepted-AOC OLD AIRFIELD ROAD RAWALPORA WANBAL SRINAGAR 190005 J K | SRINAGAR | SRINAGAR | J K | 190005 | ₹27.7 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹28.2 CrRejected-AOC | ₹28.2 Cr | L2 | Rejected-AOC Being not lowest |
| 3 | L3₹29.9 CrRejected-AOC LINK FIRST NEW AIRPORT ROAD NEAR TATA ENGINEERING GARAGE PO HUMAMA SRINAGAR 190014 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190014 | ₹29.9 Cr | L3 | Rejected-AOC Being not lowest |
| 4 | L4₹31.0 CrRejected-AOC | ₹31.0 Cr | L4 | Rejected-AOC Being not lowest |
| 5 | L5₹31.2 CrRejected-AOC 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹31.2 Cr | L5 | Rejected-AOC Being not lowest |
| Sl No | Description | Qty | Unit | M/S SHAH CONSTRUCTION L3 | mirco builders L2 | M/S ABDUL SALAM MIR CONSTR CO PVT. LTD L4 | vijay builders L5 | M/S ALBURAQ INFRATECH PRIVATE LIMITED L6 | M/S GHULAM AHMAD WANI L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Note: (i) Please refer Schedule 'A' Notes given in tender documents. (ii) The Schedule 'A' Part-XVII is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col. 5 signifies this fact only. | |||||||||
| 2.00LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS | |||||||||
| 2.01 | Lump sum price worked out by the contractor for BUILDING WORKS carried forward from Pre-Priced Schedule 'A' Part-I. | 1 | Each | 12,03,76,598 ₹12.0 Cr | 9,09,09,072.8 ₹9.1 Cr | 13,59,35,880 ₹13.6 Cr | 10,32,46,732.68 ₹10.3 Cr | 12,92,20,754.28 ₹12.9 Cr | 9,50,00,000 ₹9.5 Cr |
| 2.02 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-II. | 1 | Each | 30,00,000 ₹30 L | 34,70,702.3 ₹34.7 L | 29,36,748 ₹29.4 L | 33,37,213.83 ₹33.4 L | 32,03,725.27 ₹32.0 L | 26,96,468 ₹27.0 L |
| 2.03 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-III. | 1 | Each | 2,00,000 ₹2 L | 2,24,270.8 ₹2.2 L | 1,93,217 ₹1.9 L | 4,31,291.8 ₹4.3 L | 1,89,768.39 ₹1.9 L | 1,74,241 ₹1.7 L |
| 2.04 | Lump sum price worked out by the contractor for ROAD, PATH AND CULVERT WORKS carried forward from Pre-Priced Schedule 'A' Part-IV. | 1 | Each | 2,30,00,000 ₹2.3 Cr | 2,15,85,267 ₹2.2 Cr | 2,09,96,577 ₹2.1 Cr | 2,94,34,455.99 ₹2.9 Cr | 2,74,72,158.94 ₹2.7 Cr | 2,46,22,970 ₹2.5 Cr |
| 2.05 | Lump sum price worked out by the contractor for HARDSTANDING WORKS carried forward from Pre-Priced Schedule 'A' Part-V. | 1 | Each | 65,00,000 ₹65 L | 64,75,926 ₹64.8 L | 59,90,231 ₹59.9 L | 80,94,907.95 ₹80.9 L | 64,75,926.36 ₹64.8 L | 54,50,571 ₹54.5 L |
| 2.06 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS carried forward from Pre-Priced Schedule 'A' Part-VI. | 1 | Each | 6,00,000 ₹6 L | 8,96,162.4 ₹9.0 L | 7,36,133 ₹7.4 L | 10,56,191.52 ₹10.6 L | 7,04,127.68 ₹7.0 L | 6,46,517 ₹6.5 L |
| 2.07 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS carried forward from Pre-Priced Schedule 'A' Part-VII. | 1 | Each | 16,00,000 ₹16 L | 15,30,030.15 ₹15.3 L | 14,63,507 ₹14.6 L | 18,62,646.21 ₹18.6 L | 13,57,070.81 ₹13.6 L | 11,00,000 ₹11 L |
| 2.08 | Lump sum price worked out by the contractor for SECURITY WALL, FENCING AND GATE WORKS carried forward from Pre-Priced Schedule 'A' Part-VIII. | 1 | Each | 5,20,00,000 ₹5.2 Cr | 5,35,78,014 ₹5.4 Cr | 4,77,73,729 ₹4.8 Cr | 6,02,75,266.29 ₹6.0 Cr | 5,35,78,014.48 ₹5.4 Cr | 5,48,35,107 ₹5.5 Cr |
Tender Value
₹25.8 Cr
EMD Value
₹15 L
Closing Date
15 Sept 2025, 6:00 pmClosed
CE 31 Srinagar Zone
HQ CE 31 Srinagar Zone
CONSTRUCTION OF CERTAIN TECHNICAL ACCN ALONGWITH OTHER ALLIED INFRA AT TANGDHAR UNDER GE 874 EWS
2025_MES_722965_1
800173
Open Tender
Civil Works
700 days
GE 874 EWS
As per tender documents
12 documents required · 12 mandatory
₹3,000
GE 874 EWS
₹15 L
Yes
8 Oct 2025
31 Jul 2025
17 Sept 2025
31 Jul 2025
15 Sept 2025
1 Sept 2025
31 Jul 2025 - 12 Aug 2025
Amount
Note: (i) Please refer Schedule 'A' Notes given in tender documents. (ii) The Schedule 'A' Part-XVII is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col. 5 signifies this fact only.
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS carried forward from Pre-Priced Schedule 'A' Part-I.
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-II.
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-III.
Lump sum price worked out by the contractor for ROAD, PATH AND CULVERT WORKS carried forward from Pre-Priced Schedule 'A' Part-IV.
Lump sum price worked out by the contractor for HARDSTANDING WORKS carried forward from Pre-Priced Schedule 'A' Part-V.
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS carried forward from Pre-Priced Schedule 'A' Part-VI.
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS carried forward from Pre-Priced Schedule 'A' Part-VII.
Lump sum price worked out by the contractor for SECURITY WALL, FENCING AND GATE WORKS carried forward from Pre-Priced Schedule 'A' Part-VIII.
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-IX.
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-X.
Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORKS carried forward from Pre-Priced Schedule 'A' Part-XI.
Lump sum price worked out by the contractor for PROTECTIVE WORKS carried forward from Pre-Priced Schedule 'A' Part-XII.
Lump sum price worked out by the contractor for FIRE SYMBOL WORKS carried forward from Pre-Priced Schedule 'A' Part-XIII.
Lump sum price worked out by the contractor for DUNNAGE BLOCK WORKS carried forward from Pre-Priced Schedule 'A' Part-XIV.
Lump sum price worked out by the contractor for HOT WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-XV.
Lump sum price worked out by the contractor for SITE CLEARANCE & EARTHWORKS carried forward from Pre-Priced Schedule 'A' Part-XVI.
MISCELLANEOUS ITEMS OF WORKS (SCHEDULE 'A' PART-XVII) (A) INTERNAL ELECTRIFICATION WORKS
Supply and fixing flame proof sheet metal enclosure MCB distributiion box single pole & neutral 240 Volts 8 way suitable for hazardous area laden with gases/vapour of Group II (A) and ii(B) as per IS 2148/1984 encl as per IP-55 degree of protection and as per IS 2147/1962 made out of cast of aluminium alloy LM-06 having earthing neutral terminal and in and including following complete all as specified and directed.:- (i) MCB SPN 240 Volt, 10 kA 'C' Curve 32 Amp-01 No (Incoming) (ii) MCB SP 6 Amp 10 kA 'C' Curve 32 Amp-05 Nos (Outgoing)
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x6 mm thick buried directly in gound (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron earth lead 4mm dia by means of bolt, nuts check nuts and washers of galvanised iron and galvanised iron wire 4.00 mm dia protected by provn of GI light grade pipe 15mm bore upto 7.5mtr including provision of concrete pit in PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregates) with 50mm thick cover of precast RCC M-25 (Design Mix) reinforced with XPM (Weight not less than 3kg/Sqm) and frame of angle iron 25mmx25mmx3mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and excavation/earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No 3 of SSR -2009 Part -I and connecting to earth test point all as specified or indicated including testing on completion, complete all as specified and directed.
Supply and fixing LED light fitting 1x10 watt , 220 V, AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rosecomplete all as specified and directed.
Supply and fixing of 30 watt LED 6500K building security light with best in class design & robust heat sink along with glass leading IP, IK and surge protections for long lasting performance, complete all as specified and directed.
Supply and fixing of 9 watt LED bulb complete all as specified and directed.
(B) SEWAGE DISPOSAL WORKS
M&L for construction of 10 users LLPDE Conventional Septic Tank with upflow filter including media designed to carry sewage and sullage water, including excavation in any type of soil in foundation in PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) brick masonry in CM (1:4) RCC (M-30 design Mix) slab including cast iron manhole cover having 6mm embeded plate embeded all around with angle iron frame vent shaft etc. complete all as specified, directed and shown on drawing.
M&L for construction of soakage well of 1.8m internal dia and 3.00m deep below inlet level including foundation in PCC (1:3:6), necessary excavation in any type of soil, earth work, well of honey combed and solid in M-30 concrete, SWG inlet pipe junction 150mm bore, intercepting chamber, screen chamber brick work CM (1:6), RCC cover slab in M-30 filling with brick bats of guage 40 to 60mm, including all other relevent works, removal of surplus soul from site complete all as specified, directed and shown on drawing.
(C) SECURITY WALL WORKS
S&F Punched tape concertina coil (including spike and handle) with 56 loops and dia 600mm, max covered length 8.0RM, and weight not less than 8.0 Kg (approx) each coil, spreading length not more than 8.0RM in position complete all as specified and directed.
(D) EXTERNAL ELECTRIFICATION WORKS
Supply & Fixing of LED Street Light Fitting 72 Watt 230 V AC Outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified & directed.
Supply & Fixing of Security Light Bracket made of GI tubing 40mm dia light grade 1.2 mtr long bend to shape suitable for LED street light fitting as mentioned above fixed to pole with the help of flat iron clamp of size 40 x 6 mm (02 Nos.) with the help of nuts and bots for fixing of street light fitting with one coat of red oxide primer and two coats of aluminium paint complete all as specified & directed.
Supply, testing and commissioning of Voltage stabilizer for automatic operation, three phase, naturally oil cooled copper wounded, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 30 KVA including bypass arrangement and including steps,plinth protection, cable duct complete all as specified and directed. Note:- The Voltage stabliser shall have atleast 24 months (working period) of warranty.
Supply, installation, connecting electrically, fixing and testing of Street Light junction box made of size 155x210x92 mm, pole mounted made up of thermo plastic polycarbonate sheet 2mm thick with IP 66/67 weather proof protection for outdoor installation (with knockouts of cable entry) with terminals and locking screw fitted with 3 phase 4 wire with neutral copper Bus Bar, 415 Volts, 50 Hz and 6A MCB SP 'C' Curve type, suitable for cables off sizes and fixing on steel tubular pole at height not less than 1.5m above ground level with the help of clamps two Nos. of MS Fl 20 x 3mm and suitable nuts and bolts, complete all as specified and directed.
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), out door LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars of Amps rating as specified installed, on polymer insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally and internally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front /Rear opening type, with aprons for cable entry, with two layers of Sheet Metal Cover (should have one set of doors on inside and one set of doors outside), capable of withstanding snow and rain at installation site with maintainence proof design, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, having one chamber with door for each MCCB, having two empty chambers for future use, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size incl the provision of space to accommodate the under mentioned items. The scope of work includes the following:-
(a) Incoming (i) MCCB 4 pole, 415 volts AC grade, 16 Amps rating and 16 KA rupturing capacity - 01 Nos (b) Outgoing (i) TPN MCB 16 Amps, and 10 KA rupturing capacity - 01 Nos (ii) MCB SPN 10 Amps, and 10 KA rupturing capacity - 01 Nos (c) Digital volt meter 3 phase class1 - 01 Nos (d) Digital ammeter 3 phase class1 - 01 Nos (e) Indicator lamp R Y G B -01 set (f) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road/ ground/ floor level. (h) Current Transformer 25/5 -01 Set of Three Note :-(i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), out door LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars of 100 Amps rating as specified installed, on polymer insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally and internally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front /Rear opening type, with aprons for cable entry, with two layers of Sheet Metal Cover (should have one set of doors on inside and one set of doors outside), capable of withstanding snow and rain at installation site with maintainence proof design, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, having one chamber with door for each MCCB, having two empty chambers for future use, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size incl the provision of space to accommodate the under mentioned items. The scope of work includes the following:-
(a) Incoming (i) MCCB 4 pole, 415 volts AC grade, 16 Amps rating and 16 KA rupturing capacity - 01 Nos (b) Outgoing (i) TPN MCB 16 Amps, 415 volts AC grade, and 10 KA rupturing capacity complete - 01 Nos (ii) SPN MCB 10 Amps, 10 KA rupturing capacity complete- 03 Nos (iii) Changeover of capacity 32 Amp-01 (c) Digital volt meter 3 phase class1 Make HPL NPAMEBRITV31 - 01 Nos (d) Digital ammeter 3 phase class1 Make HPL cat No NPAMEBRITA31 - 01 Nos (e) Indicator lamp R Y G B Make Havells -01 set (f) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road/ ground/ floor level. (g) Secure 3 Phase, 1 Element, 4 Wire 440 V Digital Power Factor Meter - 01 Nos (h) Current Transformer 25/5 -01 Nos. (j) Changeover 40A, 4 Pole-01 No. Note :-(i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), out door LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars of 100 Amps rating as specified installed, on polymer insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally and internally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front /Rear opening type, with aprons for cable entry, with two layers of Sheet Metal Cover (should have one set of doors on inside and one set of doors outside), capable of withstanding snow and rain at installation site with maintainence proof design, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, having one chamber with door for each MCCB, having two empty chambers for future use, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size incl the provision of space to accommodate the under mentioned items. The scope of work includes the following:-
(a) Incoming (i) MCCB 4 pole, 415 volts AC grade, 16 Amps rating and 16 KA rupturing capacity - 01 Nos (b) Outgoing (i) SPN MCB 10 Amps, 10 KA rupturing capacity complete- 03 Nos (c) Digital volt meter 3 phase class1 Make HPL NPAMEBRITV31 - 01 Nos (d) Digital ammeter 3 phase class1 Make HPL cat No NPAMEBRITA31 - 01 Nos (e) Indicator lamp R Y G B Make Havells -01 set (f) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road/ ground/ floor level. (h) Current Transformer 25/5 -01 Nos (j) Changeover 40A, 4 Pole-01 No. Note :-(i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
Supply installation,connecting, testing and commissioning of 3 phase 4 wire 50 Hz 440 volts out door type bus bar enclosure 0.9 x 0.9 x 0.4mtr size compartmentalised cubical type with canopy, dust and vermin proof free standing floor mounting type mounted on and including 1:3:6 PCC platform with required mounting channel feeder pillar box fabricated out of 3.15 mm thick CRCA steel sheet duly pretreated and powder coated factory fabricated including cable glands of suitable sizes and consisting of the following ;- (a) Aluminium bas bar 100 amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.
Supply, installation, commissioning and testing of 10 KVA Air/liquid Cooled silent DG Set comprising of developing minimum 12.5 BHP @1500 RPM 10 KVA ,Alternator rated at three phase,415 volts,50 Hz 0.8 PF @ 1500 RPM both mounted and aligned on a common MS Base frame complete with MS fuel Tank, with idential AMF panel exhaust silencer, AVM pads fitted on baseframe, 01 Nos 12 Volts Battery, battery leads, 1st fill of Lube oil all housed in sound proof acoustic enclosure protected with asbestos rope independently supported from engine to outside power house upto 1 mtr, AVM pads foundations as per manufacure design battery start with suitable size of cable for connecting upto panel board . DG Set should be capable of operating in temperture range (-25* C to + 35*C) fitted with Cold starting kit with and including the following .
(A) Prime mover Vertical diesel engine of suitable capacity air/water cooled closed circuit as per BS-649 or IS-8528-1 direct injection type turbo charged electric starting system having rated speed 1500 RPM. The DG Set shall be capable of running 24hrs continuously with 10% over loading for one hrs continuously in every 12 hrs as per BS -649. Engine shall be equipped with all standard fitting and mounted on common base frame with following fittings. (a) RPM cum hour meter (b) Barttery charging Ammeter (c) ignition key and starting with push button switch (d) Lubricating Oil pressure gauge (e) Electronic governor controlling Oil temo gauge (g) 24 Volts starting equipment comprising of the following fittings (i)12 V Battery,180 AH (ii) Battery charging alternator (iii) Self starting of suitable capacity (iv) Battery leads of copper cable with brass thimbles and terminals. (v) starting gear engine.
(D) Other fittings (i)Battery charger having electric circuit consisting of triodes , capacitor and resistances etc. The battery charger should be able to charge the battery at all times whenever the electric supply given to battery charger through control panel or electric power point. (ii) In built Fuel tank of suitable capacity as per manufacturers instructions capable for 12 hrs running of DG Set inside the canopy base with all connecting pipes upto fuel pump and including oil level indicating gauge drain air vent plug etc. (Note : The rates of this items including the commissioning & testing complete (POL for DG Set testing will be issued by MES)
Material and labour for three single core PVC insulated sheathed stranded copper conductor flexible cable drawn into street pole of size 1.5 sqmm for connection or security/street light fitting from junction box complete all as specified and directed.
Supply and fixing factory made and tested street light panel suitable for 415 Volts 3 phase 4 wire, 50 Hz Ac supply system, having 2 mm thick mild steel sheet of suitable frame size, maximum load of 5 KW, 24 hrs digital timmer, contractor rating 20 Amps (TP), front opening type, with aprons for cable entry, with single door shutter and locking arrangements, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size including the provision of space to accomodate the undermentioned items. The scope of works includes the following :- (a) MCB 32 Amp TPN-01 Nos (b) Protection Relay - 01 Nos (c) Time relay -01 Nos (d) Voltmeter - 0 to 500 volts (voltmeter and PF meter shall be protected by MCB).
mirco builders (BID ID -3417664)
M/S SHAH CONSTRUCTION (BID ID -3417584)
M/S ABDUL SALAM MIR CONSTR CO PVT. LTD (BID ID -3417796)
vijay builders (BID ID -3423411)
M/S ALBURAQ INFRATECH PRIVATE LIMITED (BID ID -3417522)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid