Loading…
Loading…
Tender Value
₹4.8 L
EMD Value
₹9,502
Closing Date
21 Sept 2026, 11:00 am
EX. ENGINEER (ELECT)/Old Delhi Zone (CSPZ)
OFFICE OF THE EX. ENGINEER (ELECT)/Old Delhi Zone (CSPZ) UNDER GROUND CAR PARKING ASAF ALI ROAD, DELHI-110002
Provision of Split/Window type air conditioners in various locations at Mrs.G.L.M.Hospital.
2026_MCD_290395_3
33/MWEEE-I/2026-27/TC
Open Tender
Electrical Works
Percentage
90 days
CSPZ
refer special conditions
2 documents required · 2 mandatory
₹590
₹9,502
9 Sept 2026
9 Sept 2026
21 Sept 2026
9 Sept 2026
21 Sept 2026
9 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying , Installation, Testing and Commissioning of Air
Cooled Hi Wall split type Air conditioners complete with
Indoor unit(IDU), Out door unit (ODU), surface / concealed
copper Refrigerant piping with insulation (closed cell
elastomeric nitrile rubber tubular pipe section) upto 3 Mtr
(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to
ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,
wireless Remote control, suitable for working between 180-
260V with low & high voltage cutoff and 50 hz ,1 phase AC
supply capable of performing cooling, dehumidification, air
circulation of following capacity with Scroll / rotary
compressor. The system shall be able to deliver 100% of
the rated capacity upto 42 0C.
Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical
cable IS 694 or IS 9968 temperature sensing control IS
/International Electrotechnical Commission (IEC) 60730,
hermetic compressor IS 10617, heat exchanger IS 11329,
capacitor IS 2993 and motor IS 12615. Complete as per
CPWD specification and IS : 1391 Part II 2023. The system
shall be able to operate up to 50 0C (out door ambient
temperature). Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating | 5 | Each | 57,396 | ₹2,86,980 |
| 2 | Supplying , Installation, Testing and Commissioning of
Window type Air conditioners complete with copper power
cable upto 3 Mtr, wireless Remote, suitable for working
between 180- 260V with low & high voltage cutoff and 50
hz ,1 phase AC supply capable of performing, cooling,
dehumidification, air circulation, R-32/R-410A /R-407B
Green Refrigerant with Scroll / rotary compressor with min
5 year Original Equipment Manufacturer (OEM) warranty
both compressor and Printed Circuit Board (PCB),
antifreeze thermostat on the coil as a safety feature,
complete with fixing including T&P & labour etc as required
complete in all respect as specified of following capacity.
Sound level of up to 50dB inside the room is acceptable.
The unit shall be in confirmation with IS 1391 Part-I 2023
and CPWD Specification. The system shall be able to
deliver 100% of the rated capacity upto 42 0C. The system
shall be able to operate up to 50 0C (out door ambient
temperature). Inverter Type 1.5 TR with Inverter 5 Star BEE rating | 1 | No | 40,074 | ₹40,074 |
| 3 | S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V | 6 | Each | 3,361 | ₹20,166 |
| 5 | S/I/T/C of stand for split AC | 5 | meter | 788 | ₹3,940 |
| 6 | S/I/T/C of copper pipe for split AC | 116 | meter | 838 | ₹97,208 |
| 7 | S/I/T/C of Drain Pipe | 118 | meter | 106 | ₹12,508 |
| 8 | S/I/T/C of 3 Core, 4 Sqmm. Electrical wire for Air Conditioner | 90 | Meter | 158 | ₹14,220 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.84 MB
Tendernotice_2.pdf
PDF • 17.56 MB
Tendernotice_3.pdf
PDF • 0.68 MB
DNIT02_0001.pdf
Tender Documents • 6.56 MB
BOQ_338688.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .