Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.9 L+₹10,153.50 (0.57%)Rejected-Finance | L2 | Rejected-Finance Due to Highest bid quoted | |
| 3 | L3₹18.0 L+₹14,576.50 (0.82%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L3 | Rejected-Finance Due to Highest bid quoted |
Tender Value
Refer Docs
EMD Value
₹35,895
Closing Date
28 Nov 2024, 3:00 pmClosed
EE II CKHED
P12 CIT Road 1st floor Kol 14
Installation of Air Conditioning at Newly shifted Hematology Day care unit at 3rd floor Centenary Building of NRSMC and H Kolkata Electrical Installation work Electrical Work
2024_WBPWD_764287_1
WBPWD/EE-II/CKHED/ eNIT-64/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
NRS MCH
As per NIT
4 documents required · 4 mandatory
₹35,895
8 Oct 2025
23 Oct 2024
2 Dec 2024
23 Oct 2024
28 Nov 2024
1 Nov 2024
Amount
Dismantling the existing old VTPNDB light fittings, wirings ,Cables ,switch boards etc. after disconnection of all incoming & outgoing wiring etc, and stacking in old dismantled material handling room of Sub-Division as per direction of EIC.
Supply and Delivery of 1.1 KV grade following sizes Al. armoured PVC/XLPE cable (Gloster/Havells/polycab) as mentioned below as per choise of EIC.
4 Core 70 sqmm
Laying of cable 4 core XLPE/PVC insulated armoured aluminium cables
4 Core 70 sqmm (on wall with S & F MS clamps as required)) [F-1,2(d) ]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. [ F-4,7 ]
4 Core 70 sqmm [F-4,7c ]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes,anticorrosive paste & jointing materials. [ F-5,8(b) ]
4 Core 70 sqmm [ F-5,8(b,xvii) ]
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for 4 way Vertical enclosure (VTPN) with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment. [D-12,16]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [ D-11,15 ] Incoming - 415V, 36KA, 100A, FPMCCB (1 -nos) [ D-8,10 ] Outgoing - 10KA, (C-characteristics) 63A, TPMCB (4 -nos) [ D-7,8 ]
4 way [Legrand]
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex) of size 8"X10" comprising of 4 way 100 Amp. Capacity brass Stud/ terminal make- AC /DC. & 63A FP MCB (L&T) having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement,one NL on porcelain insulator etc. on wall as per direction of EIC
Supplying and fixing 2+4 way [Legrand/ L&T] single-door SPN MCB Distribution Board with IP-42/43 protection,fixing on wall incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment with Supplying and fixing 415 V 40A FP MCB type isolator of Breaking capacity 10kA & C characteristics on din rail ofexisting DBs and necessary connection [Legrand] - (1-nos) [D-5,8]
S & F 4 modular GI box flushed on wall with S &F 4 modular cover plate with S & F 240V, 25A DP MCB (make: North west) and 25A modular starter(Make: North West) incl making necessary connection as required(E19/17).
S & F 2 modular GI box on wall with S &F 2 modular plate with S & F 240V, 25A 3 pin modular type plug socket (make: North west) incl making necessary connection as required(E17/ 5b).
S & F 240V, 25A, 3 pin modular type plug top with indicator (make: North west) incl making necessary connection as required(E17/ 5b).
Supply and Fixing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire(RR Cable/Finolex/ /Polycab/KEI) as approved by EIC) of the following sizes in 20mm/25mm/32mm the PVC Rigid Conduit 'FR' [Make-Precision] on wall, ceilling with saddle and other accessories as required and mending good damages to building works.
4 x 10 sqmm+2x 6 sqmm ECC) [ E-9,1(d1) & E-16,7(b) ]
2x4 sqmm+1x 2.5 sqmm ECC [ E-9,1(v) & E-16,7(a) ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [ F-5,9 ]
4 x 10 sqmm+2x 6 sqmm ECC) [ F-5,9(iv&iii)]
2x4 sqmm+1x 2.5 sqmm ECC [ F-5,9(ii&i)]
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (RR Cable/KEI/ Polycab) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/ Perspex (wall matching colour) top cover 3 mm thick and incl.175mmx100mmx 65 mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish as to GS. [Vide page no-E-14,item no-2 ]
Average run 8 mtr [Vide page no-E-14,item no-2(c)]
On board [Vide page no-E-15,item no-4(a)]
Fixing only old single/twin fluorescent light fitting complete with all accessories with (14 SWG) 2nos GI-L clamps for every light Fittings on wall/ceiling of Suitable Size MS fastener, etc.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.(C2-16)
Supply & Delivary of 415V, 3-Ph, 7.5TR capacity concealed type Split Air Conditioner (3-Star rated) of rated cooling capacity of 90000 BTU/hr. with 3Nos. twin rotary compressor (R-410A), 3nos. IDU, Air-flow/per IDU:- 1000CFM. & Individual Wire Remorte. ( Make: Hitachi/Mitsubishi-Electric/O General)
Supply & Delivery of 230V-1ph, 2TR capacity concealed type Split Air Conditioner (3-Star rated) cooling capacity of 24000 BTU/hr. with 1Nos. rotary compressor (R-32), 1nos. IDU, Air-flow/per IDU:- 800CFM & wireless remote. ( Make:Hitachi/Mitsubishi-Electric/O-General)
Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku)
Liquid Line (3/8" OD with 0.6 mm thick)
Suction Line (5/8" OD with 0.7mm thick)
Liquid Line (1/4" OD with 0.6 mm thick)
Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Accoflex)
Liquid Line (3/8" OD with 0.6 mm thick)
Suction Line (5/8" OD with 0.7mm thick)
Liquid Line (1/4" OD with 0.6 mm thick)
Erection with required size of MS angle fitted on wall, and other accessories , Commissioning & Testing of 7.5 TR concealed type Split Air Conditioning machines( Both IDU and ODU).
Erection, Commissioning & Testing of 2 TR concealed type Split Air Conditioner.
S & F 4 core 2.5 sq.mm copper cable for communication from Condensing Unit to control panel (Make: polycab/RR Cable/finolex)
S & L of Drain Water piping work out of 3mm thick / Schedule 40 UPVC pipe of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors. (Make-Supreme/Astra/Ashirvad/Prayag)
32 mm dia
25 mm dia
Charges for scaffolding arrangement incl. lifting for outdoor & indoor units
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of outdoor unit of Concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be barricaded & safe for ODU maintenance. Area of the platform is 3Mtr. x 1.2Mtr. Structural design should be approved by E.I.C.
Charges for Refrigerant gas R32/R410/R-410A for 7.5TR concealed type Split Air Conditioner.
Supplying, fitting & fixing in position suspended boxing for return air arrangement & indoor units of concealed split airconditioner with frame work of aluminium hollow section of size 50mm x25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm ,25mm x 25mm powder coated wall angle with aluminium composit panel of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent including suitable arrangement for grill fixing complete in all respect as per direction of EIC.
charges for trap door of 1600 mm x 600 mm and 9 mm thickness made of aluminium channel & ACP sheet for IDU maintenance.
Supply and fixing flexible canvass connection for concealed split air-conditioners.
Supply and Fixing AL power Coated countintuous girll (Make-Premier)
Charges for trap door of 1600 mm x 600 mm and 9 mm or as per requirement made of aluminium channel & ACP board/ gypsum board annd others necessary arrangement for IDU maintenance.
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
NEW ENVIRONMENT CONTROL CO. (BID ID -5789770)
SKY DECORATIONS PRIVATE LIMITED (BID ID -5788633)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .