Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99,220Accepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹1.0 L+₹1,420 (1.43%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹1.1 L+₹6,860 (6.91%)Accepted-Finance | L3 | Accepted-Finance OK | |
| 4 | L4₹1.2 L+₹19,566 (19.7%)Accepted-Finance | L4 | Accepted-Finance OK |
Tender Value
₹1.3 L
Closing Date
23 Jul 2021, 3:00 pmClosed
Executive Engineer (E) P
Room No. T-517, Fifth Floor, T.E. Building Lodhi Road, 9 CGO Complex, MTNL, New Delhi-110003.
Providing Electrical Work in lift shaft and machine room at TE bldg Laxmi Nagar, Delhi
2021_MTNL_638376_1
EE(E)P/2021-22/09
Open Tender
Electrical Works
Item Rate
10 days
NEW DELHI
Please refer Tender documents.
6 documents required · 6 mandatory
₹590
MTNL ,Delhi
Exempted
23 Sept 2021
13 Jul 2021
24 Jul 2021
13 Jul 2021
23 Jul 2021
13 Jul 2021
Amount
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, for FP MCB /Isolator/RCCB/RCBO as incomer and SP/TP MCBs as outgoing 63 Amp, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) earthing the body as required. a) 4 way TPDB (Make Legrand/ L&T/ Havells)
Supplying and fixing following rating, Three pole, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 32 amp RCCB (Make Legrand/ L&T/ Havells)
Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 5 amps to 32 amps (Make Legrand L&T Havlls)
(b) 63 amp DP Isolator
S/F following modular switch / socket on the existing modular plate & switch box including connections but exlcuding modular plate etc as reqd. (M/S Anchor /Havells make with ISI marked.) a) 15/16 amps switch
(b) 6 pin 15 / 16 amps socket outlet
(c) 2 way 5/6 A switch
S/L of following size Copper conductor XLPE armoured power cable of 1.1 KV grade on wall / cable tray i/c connection etc as reqd.(ISI marked) (a) 2x1.5 Sq mm
(b) 2x4 Sq mm
S/M end termination with brass compression gland Alu. lugs for following size XLPE / armoured power cable of 1.1 KV grade as reqd. (a) 2x1.5 Sq mm
(b) 2x4 Sq mm
Supplying, installing of surface mounting 10 watt 230 volt, 50 HZ LED slimline fitting wall lamp complete with all accessories i/c connection etc. as reqd.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. a)3 x 1.5 sqmm
b)3 x 4 sqmm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess/ wooden partions including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required(a)20 mm
S/F 4 feet LED Batten fitting with integral electronic driver and LED tube operated on 230 V 50 Hz AC Supply on surface with mounting arrangement connections etc complete as reqd (System wattage 20-22 W system, lumen output-1850-2000 lumens etc) Make-Philips,Osram, Havells,Bajaj,Surya
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (a) 100 mm X 100 mm X 60 mm deep
SITC of following type 230 V 50 Hz AC supply metal exhaust fan with louver shutter in existing opening with necessary arrangement i/c connection etc as reqd(M/s Crompton/Usha/Havells make with ISI Marked). (a) 450 mm (18") Exhaust fan
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Dismantling the existing faulty armoured power cable upto 4x50 sq mm, DB, fittings in the lift machine room and lif shaft etc complete as reqd.
KASHYAP ELECTRICALS
M/s Satyam Enterprises
Handa Electric Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .