Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.3 CrAccepted-AOC RG METRO ARCADE SECTOR 11 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹51.3 Cr Quoted ₹57.3 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹60.0 CrRejected-Finance 807 PEARL BUSINESS PARK NETAJI SUBHASH PLACE PITAMPURA DELHI | DELHI | DELHI | ₹60.0 Cr | L2 | Rejected-Finance Rejected |
| 3 | L3₹62.3 CrRejected-Finance PLOT NO B 1 INFOCITY SECTOR 34 GURGAON HARYANA 122004 | GURUGRAM | HARYANA | 122004 | ₹62.3 Cr | L3 | Rejected-Finance Rejected |
| 4 | L4₹90.9 CrRejected-Finance B 31 32 2ND FLOOR INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 RAJASTHAN | JODHPUR | RAJASTHAN | 342003 | ₹90.9 Cr | L4 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | Subhash Infraengineers Pvt. Ltd. L4 | PULKIT PROJECTS PRIVATE LIMITED L1 | ENVIRO INFRA ENGINEERS LIMITED L2 | VISHNU PRAKASH R PUNGLIA LIMITED L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Part -A -Up-gradation / Renovation of existing 100 MLD STP
Designing, Construction, Supply, Erection, Testing, Commissioning of IR Sump and over flow sump complete in all respect including related contingent work thereto at existing 100 MLD STP Dhanwapur, Gurugram as per Specification and details given in the DNIT including one year defect liability period. a) Civil Works | 1 | Job | 27,76,375.69 ₹27.8 L | 1,00,00,000 ₹1 Cr | 20,00,000 ₹20 L | 50,00,000 ₹50 L |
| 2.00 | Part -A -Up-gradation / Renovation of existing 100 MLD STP
Supply, Erection, Testing and Commissioning of Sluice Valve (Manual) of size 100mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period. | 204 | Each | 16,041.28 ₹32.7 L | 10,000 ₹20.4 L | 10,000 ₹20.4 L | 16,000 ₹32.6 L |
| 3.00 | Part -A -Up-gradation / Renovation of existing 100 MLD STP
Supply, Erection, Testing and Commissioning of Sluice Valve (Motorized) of size 100mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period. | 8 | Each | 1,25,862.36 ₹10.1 L | 70,000 ₹5.6 L | 1,00,000 ₹8 L | 95,000 ₹7.6 L |
| 4.00 | Part -A -Up-gradation / Renovation of existing 100 MLD STP
Supply, Erection, Testing and Commissioning of Sluice Valve (Motorized) of size 200mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period. | 16 | Each | 1,35,733.92 ₹21.7 L | 1,00,000 ₹16 L | 1,40,000 ₹22.4 L | 1,40,000 ₹22.4 L |
| 5.00 | Part -A -Up-gradation / Renovation of existing 100 MLD STP
Supply, Erection, Testing and Commissioning of Sluice Valve (Motorized) of size 400mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period. | 12 | Each | 5,60,210.92 ₹67.2 L | 2,00,000 ₹24 L | 2,50,000 ₹30 L | 2,80,000 ₹33.6 L |
| 6.00 | Part -A -Up-gradation / Renovation of existing 100 MLD STP
Supply, Erection, Testing and Commissioning of Sluice Valve (Motorized) of size 450mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period. | 6 | Each | 3,64,013.7 ₹21.8 L | 3,00,000 ₹18 L | 3,00,000 ₹18 L | 3,25,000 ₹19.5 L |
| 7.00 | Part -A -Up-gradation / Renovation of existing 100 MLD STP
Supply, Erection, Testing and Commissioning of Sluice Valve (Motorized) of size 600mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period. | 9 | Each | 5,55,275.14 ₹50.0 L | 4,00,000 ₹36 L | 4,50,000 ₹40.5 L | 6,25,000 ₹56.3 L |
| 8.00 | Part -A -Up-gradation / Renovation of existing 100 MLD STP
Supply, Erection, Testing and Commissioning of Non Return Valve (NRV) (Manual) of size 100mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period. | 2 | Each | 17,275.23 ₹34,550.46 | 20,000 ₹40,000 | 20,000 ₹40,000 | 15,000 ₹30,000 |
| 9.00 | Part -A -Up-gradation / Renovation of existing 100 MLD STP
Supply, Erection, Testing and Commissioning of Non Return Valve (NRV) (Manual) of size 200mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period. | 6 | Each | 44,422.01 ₹2.7 L | 50,000 ₹3 L | 30,000 ₹1.8 L | 55,000 ₹3.3 L |
| 10.00 | Part -A -Up-gradation / Renovation of existing 100 MLD STP
Supply, Erection, Testing and Commissioning of Non Return Valve (NRV) (Manual) of size 400mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period. | 9 | Each | 2,28,279.78 ₹20.5 L | 1,00,000 ₹9 L | 50,000 ₹4.5 L | 2,00,000 ₹18 L |
Tender Value
₹59.6 Cr
EMD Value
₹1.2 Cr
Closing Date
25 Apr 2025, 3:00 pmClosed
PARIK GARG
Division - Sewerage
Upgradation of existing 100 MLD Sewerage Treatment Plant and construction of 75 MLD Tertiary Treatment Unit at Dhanwapur Sewage Treatment Works with Operation and Maintenance For 5 Years after 12 Months Defect Liability Period for reuse of treated ef
2025_HRY_437111_1
2025C50C44AB F224 4066 ABCA 723878F0B323717001
Open Tender
Civil Works
720 days
Gurugram
2 documents required · 2 mandatory
₹1,180
₹1.2 Cr
Yes
Plot No. 3, Sec-44, Gurugram
13 Aug 2025
29 Mar 2025
25 Apr 2025
29 Mar 2025
25 Apr 2025
29 Mar 2025
4 Apr 2025
Amount
Part -A -Up-gradation / Renovation of existing 100 MLD STP Designing, Construction, Supply, Erection, Testing, Commissioning of IR Sump and over flow sump complete in all respect including related contingent work thereto at existing 100 MLD STP Dhanwapur, Gurugram as per Specification and details given in the DNIT including one year defect liability period. a) Civil Works
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Sluice Valve (Manual) of size 100mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Sluice Valve (Motorized) of size 100mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Sluice Valve (Motorized) of size 200mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Sluice Valve (Motorized) of size 400mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Sluice Valve (Motorized) of size 450mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Sluice Valve (Motorized) of size 600mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Non Return Valve (NRV) (Manual) of size 100mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Non Return Valve (NRV) (Manual) of size 200mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Non Return Valve (NRV) (Manual) of size 400mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Non Return Valve (NRV) (Manual) of size 450mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Non Return Valve (NRV) (Manual) of size 600mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Dismantling Joint of size 100mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Dismantling Joint of size 200mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Dismantling Joint of size 400mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Dismantling Joint of size 450mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Ultrasonic level Sensors, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Mixers at anoxic chamber (10 HP), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of SS 316l Baffle wall (25 M x 1.2M x 6mm), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of 500mm dia MS Spiral Welded with 3 layers pipe, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of 100mm dia SS 316L pipe pipe below water air piping drop pipe and lateral, fabricated drop pipe 100 NB SS 316 SCH 10 ERW with welded Flange and Elbow, lateral pipe of 100 NB SS 316, ERW SCH10, along with its required fittings flanges, end cap etc of Sch 40 and required Nut bolts, supports for drop and lateral in SS 316 and specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Diffusers (92mm x 1000mm x 2), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Helical Hybrid Blower (13000 Cum/hr @ 0.65 kgf/cm^2g), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of IR Pump (Non Clog Submersible) (2300 cum/hr @ 10 MWC), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Return Activated Sludge Pump (Non Clog Submersible) (1300 cum/hr @10MWC), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Excess Sludge Pump (Non Clog Submersible) (40cum/hr@10MWC), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Combined Sludge Lifting Pump (Non Clog Submersible) (254 cum/hr @ 10 MWC), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Overflow Pump (Non Clog Submersible) (260cum/hr@10MWC), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Digesters Feed Pump Underhold (Screw Pump) (33cum/hr@20MWC), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of BFP Feed Pump (Screw Pump) (33cum/hr@20MWC), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Organic Return Pump (Non Clog Submersible) (500LPH@10MWC), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Lime Dosing Pump (Metering Pump) (700LPH), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Ferric Alum Dosing Pump (Metering Pump) (306LPH), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Polyelectrolyte Dosing Pump (Metering Pump) (1094LPH), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Safety Items such Chlorine Leak Detector with single sensor (2 Nos), Air Breathing apparatus, Instant action resuscitator, Protective clothing, Non locking steel cabinet, Safety shower with eye wash, Residual test kit, canister gas mask, spare canister, emergency repair kit -B, Ammonia torch and ammonia bottle 250ml etc., specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of EOT (1.5 Tonne) at Primary Clarifier Sludge sump with pump house, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of EOT (1.5 Tonne) at Thickened Sludge Sump / Digester Feed Sump with pump house, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of EOT (1.5 Tonne) at Chemical House (Double Storied), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
art -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of EOT (5 Tonne) at Belt Filter Press and Blower cum MCC Building, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Automation System (PLC/SCADA), specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Piping D.I. (K-9) Pipe of size 500mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Piping D.I. (K-9) Pipe of size 750mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Design, Supplying, Erection, Testing and Commissioning of Transformer with minimum capacity 2000KVA and all other works contingent thereto as per sizes and specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -B - Construction of 75 MLD Tertiary Treatment Unit at STP Dhanwapur Designing, Construction, Supply, Erection, Testing, Commissioning of 75 MLD Capacity Tertiary Treatment Plant comprising of Mechanical, Electrical, Piping and Instrumentation Works including various items such as all type of required pump, Sluice Valve, Non Return Valve, Dismantling Joints, Ultrasonic Level Sensors, 9 Nos. mixers at anoxic chamber, SS 316l Baffle Wall, 500mm dia MS spiral Welded with 3 layers, SS 316L Pipe, Diffusers, Helical Hybrid Blower, Internal Recirculation pumps, RAS and Excess Sludge Pumps, Combined Sludge Lifting Pumps, Overflow Pumps, Digesters Feed Pump, BFP feed Pump, Organic Return pump, Metering Pump for Lime, Ferric Alum and Polyelectrolyte dosing pump, Gaseous Chlorinators, Safety Items, EOT, Automation System - PLC / SCADA, Piping etc. complete in all respect including related contingent work thereto at existing STP Dhanwapur, Gurugram as per Specification and details given in the DNIT including trial run period of three months with chemicals and one year defect liability period and OandM for five years thereafter. (Chemicals and Electricity during defect liability period of One year and thereafter for OandM period of Five years will be supplied by Deptt.) b) Mechanical, Electrical and Instrumentation Works
Part -B - Construction of 75 MLD Tertiary Treatment Unit at STP Dhanwapur Designing and Constructing of RCC M-25 Framed structure Confirming to National Building Code for Chemical house Building (Minimum Area of Chemical House (Double Storied) comprising 250Sqm on each Floor or more if required as per design) including all Electrical, Mechanical and other contingent work thereto as per sizes and specification given in the DNIT at Existing STP Dhanwapur, Gurugram including O and M for one year defect liability period and five years thereafter complete.
Part -B - Construction of 75 MLD Tertiary Treatment Unit at STP Dhanwapur Designing and Constructing of RCC M-25 Framed structure Confirming to National Building Code for Toner shed and Chlorination room (Minimum Area of Toner Shed (single storied) comprising 40 Sqm plus 40 Sqm or more if required as per design) including all Electrical, Mechanical and other contingent work thereto as per sizes and specification given in the DNIT at Existing STP Dhanwapur, Gurugram including O and M for one year defect liability period and five years thereafter complete
Part -B - Construction of 75 MLD Tertiary Treatment Unit at STP Dhanwapur Designing and Constructing of RCC M-25 Framed structure Confirming to National Building Code for Annexed Building (Minimum Area of Annexed Building (double storied) comprising 100 Sqm on each floor or more if required as per design) including all Electrical, Mechanical and other contingent work thereto as per sizes and specification given in the DNIT at Existing STP Dhanwapur, Gurugram including O and M for one year defect liability period and five years thereafter complete
Part -B - Construction of 75 MLD Tertiary Treatment Unit at STP Dhanwapur Designing and Constructing of RCC M-25 Framed structure Confirming to National Building Code for Clear Water Pump House (Minimum Area (single storied) comprising 200 Sqm or more if required as per design) including all Electrical, Mechanical and other contingent work thereto as per sizes and specification given in the DNIT at Existing STP Dhanwapur, Gurugram including O and M for one year defect liability period and five years thereafter complete
Part -B - Construction of 75 MLD Tertiary Treatment Unit at STP Dhanwapur Designing and Constructing of RCC M-25 Framed structure Confirming to National Building Code for Clear Water Recycling Panel Room (Minimum Area (single storied) comprising 80 Sqm or more if required as per design) including all Electrical, Mechanical and other contingent work thereto as per sizes and specification given in the DNIT at Existing STP Dhanwapur, Gurugram including O and M for one year defect liability period and five years thereafter complete
Part -B - Construction of 75 MLD Tertiary Treatment Unit at STP Dhanwapur Design, Supplying, Erection, Testing and Commissioning of Transformer with minimum capacity 2000 KVA (1W plus 1SB) or more as per design etc. and all other works contingent thereto as per sizes and specification given in the DNIT at Existing STP Dhanwapur, Gurugram including O and M for one year defect liability period and five years thereafter.
Part -B - Construction of 75 MLD Tertiary Treatment Unit at STP Dhanwapur Design and Construction of 3.75 Mtr to 5.00 Mtr wide CC Roads and pavements with embankment as required gradient with 150mm thick (1:3:6) with concrete base and 200mm thick M-25 Design Mix Concrete with Kerb and channels, Supplying and installing of 8.00 Mtr. high LED solar street light at 30M c/c, Main gates, walkways, leveling etc. complete in all respect and all other work contingent thereto as per sizes and specification given in the DNIT at Existing STP Dhanwapur, Gurugram including O and M for one year defect liability period and five years thereafter complete.
Part -B - Construction of 75 MLD Tertiary Treatment Unit at STP Dhanwapur Design and Construction of RCC Platforms for DG sets, Transformers, etc and all other work contingent thereto as per sizes and specification given in the DNIT at Existing STP Dhanwapur, Gurugram including O and M for one year defect liability period and five years thereafter.
Part -B - Construction of 75 MLD Tertiary Treatment Unit at STP Dhanwapur Providing chemical i.e. FeCl3, Lime, Poly for flocculation and Chlorine for 3 months trial run and all other works contingent thereto.
Part -B - Construction of 75 MLD Tertiary Treatment Unit at STP Dhanwapur Designing, Construction, Supply, Erection, Testing, Commissioning of 75 MLD Capacity Tertiary Treatment Plant comprising of Treated Water Equalization Tank, Waste Water sump for pumps, Inlet Chamber, Inlet Channel from Chamber to Flash Mixer, flash mixer inlet chamber, flash mixer, Inlet channel from Flash Mixer to flocculators., flocculator, Inclined tube settlers, Wash water manhole, Filters, Outlet Channel, Filter Bed, Filter House, Tourghs, Outlet Box, Manifold Channel, Chlorine Clear Water Tank, Chemical solution tanks for FeCl3, Lime and Polyelectrolyte, Bach Wash Water Tank, Sludge Pump sump, Wash Water Sump, Clear Water Sump and pump bay etc complete in all respect including related contingent work thereto at existing STP Dhanwapur, Gurugram as per Specification and details given in the DNIT including trial run period of three months with chemicals and one year defect liability period and Oand M for five years thereafter. (Chemicals and Electricity during defect liability period of One year and thereafter for OandM period of Five years will be supplied by Deptt.) a) Civil Works
Part -A -Up-gradation / Renovation of existing 100 MLD STP Supply, Erection, Testing and Commissioning of Piping D.I. (K-9) Pipe of size 100mm dia, specification given in the DNIT at Existing STP Dhanwapur, Gurugram including one year defect liability period.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Comprehensive Repair and Maintenance of 2 No. 800 KW Bio Gas Engine (Make – MWM TCG 2016 V16 C) including replacement of components and overhauling and refurbishment of Balance of Plant (BOP) components and all balance of Plant (BOP) components. All additional works necessary to ensure the seamless functioning 100 MLD STP at Dhanwapur, Gurugram. The parts procurement, repair and replacement must be carried out by an authorized Original Equipment Manufacturer (OEM) to achieve performance maximum to 80 - 85% of capacity at existing 100 MLD STP Dhanwapur, Gurugram including one year defect liability period. The agency shall visit the site before quoting their rates.
Part -A -Up-gradation / Renovation of existing 100 MLD STP Comprehensive Repair and Refurbishment of Bio Gas Scrubber Unit including replacement of complete gas mixing with lancers, complete H2S Scrubber, Dehumidifie. All additional works necessary to ensure the seamless functioning of 100 MLD STP at Dhanwapur, Gurugram. The parts procurement, repair and replacement must be carried out by an authorized Original Equipment Manufacturer (OEM) to achieve performance maximum to 100% of capacity at existing 100 MLD STP Dhanwapur, Gurugram including one year defect liability period. The agency shall visit the site before quoting their rates.
Bidder Name
Amount
Subhash Infraengineers Pvt. Ltd. (GSTN-06AANCS5001K1ZB) BID ID -1244222
PULKIT PROJECTS PRIVATE LIMITED (GSTN-NA) BID ID -1248177
ENVIRO INFRA ENGINEERS LIMITED (GSTN-NA) BID ID -1248983
VISHNU PRAKASH R PUNGLIA LIMITED (GSTN-NA) BID ID -1248956
PULKIT PROJECTS PRIVATE LIMITED (BID ID -1248177)
Subhash Infraengineers Pvt. Ltd. (BID ID -1244222)
VISHNU PRAKASH R PUNGLIA LIMITED (BID ID -1248956)
ENVIRO INFRA ENGINEERS LIMITED (BID ID -1248983)
VISHNU PRAKASH R PUNGLIA LIMITED (BID ID -1248956)
Subhash Infraengineers Pvt. Ltd. (BID ID -1244222)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid