| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 CrAccepted-AOC 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹4.6 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹4.7 Cr+₹4.7 L (1.01%)Rejected-Finance 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹4.7 Cr+₹4.7 L (1.01%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹4.9 Cr+₹24.7 L (5.35%)Rejected-Finance | ₹4.9 Cr+₹24.7 L (5.35%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹4.9 Cr+₹32.8 L (7.10%)Rejected-Finance | ₹4.9 Cr+₹32.8 L (7.10%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹5.3 Cr+₹67.1 L (14.6%)Rejected-Finance | ₹5.3 Cr+₹67.1 L (14.6%) | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/S Inderjit Sharma and Co. L6 | JINDAL BUILDERS L4 | SHIVAE CONSTRUCTION L2 | vijay builders L1 | Om Parkash Nargotra Constructions Pvt Ltd L3 | d d builders L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Sch 'A' Part-I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only. | |||||||||
| 1.01 | Construction of block of Offrs Mess complete all as shown on drawings and as specified. | 1 | Each Block | 2,91,00,000 ₹2,91,00,000 | 2,61,81,900 ₹2,61,81,900 | 2,30,00,000 ₹2,30,00,000 | 2,40,00,000 ₹2,40,00,000 | 2,26,00,000 ₹2,26,00,000 Lowest | 2,94,77,677.77 ₹2,94,77,677.77 |
| 1.02 | Construction of block of Servant Quarter complete all as shown on drawings and as specified. | 1 | Each Block | 95,00,000 ₹95,00,000 | 72,90,000 ₹72,90,000 Lowest | 92,00,000 ₹92,00,000 | 75,00,000 ₹75,00,000 | 74,00,000 ₹74,00,000 | 89,54,789.99 ₹89,54,789.99 |
| 1.03 | Construction of block of Car Garage (09 Cars) complete all as shown on drawings and as specified. | 1 | Each Block | 23,86,311.13 ₹23,86,311.13 | 20,70,000 ₹20,70,000 | 22,00,000 ₹22,00,000 | 18,00,000 ₹18,00,000 Lowest | 21,00,000 ₹21,00,000 | 28,65,487.99 ₹28,65,487.99 |
| 2.00 | Total Amount of Sch 'A' Part - II (Internal Water Supply Work) | 1 | Lump sum | 1,89,449 ₹1,89,449 Lowest | 2,36,875 ₹2,36,875 | 2,95,000 ₹2,95,000 | 2,27,339.58 ₹2,27,339.58 | 3,41,009.37 ₹3,41,009.37 | 2,72,807 ₹2,72,807 |
| 3.00 | Total Amount of Sch 'A' Part - III (Internal Electric Supply Work) | 1 | Lump sum | 10,87,041.19 ₹10,87,041.19 | 9,45,945 ₹9,45,945 | 7,60,000 ₹7,60,000 Lowest | 10,87,041.19 ₹10,87,041.19 | 11,41,393.3 ₹11,41,393.3 | 9,68,336 ₹9,68,336 |
| 4.00 | Total Amount of Sch 'A' Part - IV (Plumbing Work) | 1 | Lump sum | 2,49,015 ₹2,49,015 Lowest | 3,05,610 ₹3,05,610 | 3,30,000 ₹3,30,000 | 3,28,248.58 ₹3,28,248.58 | 3,16,929.67 ₹3,16,929.67 | 3,21,457 ₹3,21,457 |
| 5.00 | Total Amount of Sch 'A' Part - V (Area Drainage Work) | 1 | Lump sum | 15,17,962 ₹15,17,962 | 18,58,729 ₹18,58,729 | 16,41,000 ₹16,41,000 | 15,48,941.3 ₹15,48,941.3 | 18,58,729.56 ₹18,58,729.56 | 13,75,777.87 ₹13,75,777.87 Lowest |
| 6.00 | Total Amount of Sch 'A' Part - VI (Sewage Disposal Work) | 1 | Lump sum | 2,69,743.85 ₹2,69,743.85 | 2,77,677 ₹2,77,677 | 3,67,000 ₹3,67,000 | 2,64,454.75 ₹2,64,454.75 | 3,96,682.13 ₹3,96,682.13 | 2,30,540 ₹2,30,540 Lowest |
| 7.00 | Total Amount of Sch 'A' Part -VII (Road, Path, Culvert and Hard Standing Work) | 1 | Lump sum | 34,25,000 ₹34,25,000 | 35,71,275 ₹35,71,275 | 32,74,462 ₹32,74,462 | 32,74,462.93 ₹32,74,462.93 | 29,79,761.26 ₹29,79,761.26 Lowest | 29,98,909 ₹29,98,909 |
Tender Value
₹5.3 Cr
EMD Value
₹5.9 L
Closing Date
5 Jan 2026, 6:00 pmClosed
Chief Engineer Udhampur Zone
HQ Chief Engineer Udhampur Zone, PIN-900386, C/O 56 APO
PROVN OF OFFRS MESS UNDER GE (N) UDHAMPUR
2025_MES_742369_1
87977-A/E8
Open Tender
Civil Works
Lump-sum
910 days
Udhampur
As per NIT
8 documents required · 8 mandatory
₹3,000
GE (N) Udhampur
₹5.9 L
Yes
HQ Chief Engineer Udhampur Zone
23 May 2026
1 Dec 2025
7 Jan 2026
1 Dec 2025
5 Jan 2026
30 Dec 2025
2 Dec 2025 - 28 Dec 2025
8 Dec 2025
Construction of block of Offrs Mess complete all as shown on drawings and as specified.
Construction of block of Servant Quarter complete all as shown on drawings and as specified.
Construction of block of Car Garage (09 Cars) complete all as shown on drawings and as specified.
Total Amount of Sch 'A' Part - II (Internal Water Supply Work)
Total Amount of Sch 'A' Part - III (Internal Electric Supply Work)
Total Amount of Sch 'A' Part - IV (Plumbing Work)
Total Amount of Sch 'A' Part - V (Area Drainage Work)
Total Amount of Sch 'A' Part - VI (Sewage Disposal Work)
Total Amount of Sch 'A' Part -VII (Road, Path, Culvert and Hard Standing Work)
Total Amount of Sch 'A' Part - VIII (External Water Supply Work)
Total Amount of Sch 'A' Part - IX (External Electric Supply Work)
Total Amount of Sch 'A' Part -X (Compound Wall , Fencing and Gate Work)
Total Amount of Sch 'A' Part -XI (Hot Water Supply Work)
MCB, Single pole, 240 volt, 40 Amp, 10KA rating, "C" curve, complete with connection testing and commissioning, complete all specified and directed.
a) 03 No porcelains HV bushing with arching horns on HV side suitable for 11 KV complete with bushing rods nuts. b) 01 No cable end box on LV secondry side consisting of 05 No porcelain bushing (One No neutral earth, One No Neutral and 3 No for phase connected bushing) with bushing rods and nuts washers and cable glands suitable for reception of out 3.5 core 400 Sqmm cable 3 runs, LT 1100 V grade XLPE insulated heavy duty including gland joint complete. c) Oil conservator with filter type drain valve and oil level guage. d) Dehydrating breather with first filling of dehydrating agent e) Explosive vent. f) THERMOMETER pocket including temperature gauge g) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strips. (Contd.../)
Construction of valve pit of size (90x60x60)cm (Internal dimensions) using PCC (1:4:8) type D-2, using 40mm graded crushed stone aggregate for foundation 10cm thick and 100mm off sets on all sides, 230mm thick brick masonary walls built in cement mortar (1:6), 15mm thick rendering all around the masonry work in cement (1:6), for internal and up to 15cm below GL for external surfaces of walls, 50mm thick PCC (1:2:4) type B-1 coping with 20mm graded crushed stone aggregate including necessary form work for grouting including 3.15mm thick, MS top sheet cover double door with locking arrangement welded to MS frame made out of (50x60x6)mm angle iron frame fixed with hold fasts in coping including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer as finishes coat including necessary excavation in any kind of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as specified and directed.
Point wiring complete with 1.5 sqmm PVC insulated, FRLSH, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc; metal flush boxes suitable modules as directed with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick, including modular top cover plate as per numbers of switch modules for fixing of modular switches,sockets,fan regulators, red colour indicator, blank plates etc. as approved colours and including 1.5 Sqmm PVC insulated multistranded FRLSH unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:-
One light/fan/bell point controlled by one switch
Sintex box of size 155mmX210mmX92mm, hinged (L) wiith 2 way connector mounted on epoxy insulators for looping of cable for phase and neutral fixed on pole with the help of MS nuts bolts and MS clamps; 2 No of size 40mm X 4mm thick, with one No MCB SP 6 Amp capacity mounted on din rail inside box, including making suitable hole in pole to take out connections to fitting if required at site and provisioning of conector of street light, complete all as specified. Make:- Hensel, Sintex or equivalent make approved by GE.
One socket outlet 3 Pin, 5 Amps, on the same board
One two way point controlled by one 2 way switch
One light point controlled by 2 way switches,
Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed. Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.
Sub main wiring with two run of single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmm as earth continuity conductor connected to commen earth dolly complete all as specified
and directed. Note: - Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Drg5_compressed.pdf
Additional Documents • 1.38 MB
Drg8_compressed.pdf
Additional Documents • 0.85 MB
Drg7_compressed.pdf
Additional Documents • 0.64 MB
TENDER.pdf
Tender Documents • 7.75 MB
Drg1_compressed.pdf
Additional Documents • 1.28 MB
Drg2_compressed.pdf
Additional Documents • 1.02 MB
Drg3_compressed.pdf
Additional Documents • 5.24 MB
Drg4_compressed.pdf
Additional Documents • 2.08 MB
BOQ_831316.xls
BOQ • 0.35 MB
Drg6_compressed.pdf
Additional Documents • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .