Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | MILLENNIUM AIRCON L1 |
|---|---|---|---|---|
| 1.00 | Supply & delivery of Non-Inverter type split Air-conditioner machine having cooling capacity not less than 7625W,ISSER 3.8 to 4.39,BEE rating not less than 3 star, Noise level not more than 50db. This Split Air Conditioning machine fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant- R32/R410A. (Mitsubishi Heavy Industries model No. SRK25CSS – S6/A). | 2 | nos. | 69,250 ₹1,38,500 Lowest |
| 2.00 | Installation, testing & commissioning of the above-said split AC outdoor unit by fixing iron angle unit on wall & mending good the damages as per direction of E.I.C. | 2 | item | 2,100 ₹4,200 Lowest |
| 3.00 | Supply & Installation of Extra Add-on items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC. | 15 | Mtrs | 600 ₹9,000 Lowest |
| 4.00 | Supply & laying 1.1KV grade 3 core 4 sqmm flexible copper Cable with screw, saddle,drill machine nut bolt etc all necessary items needed for connection. (from starter to A.C outdoor Connection)(Make- Finolex/Havells/Polycab/Gloster as approved by E.I.C) | 15 | mtrs | 125 ₹1,875 Lowest |
| 5.00 | Supply & Laying of 4core 1.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/Polycab as approved by E.I.C) | 20 | Mtrs | 95 ₹1,900 Lowest |
| 6.00 | Supply & delivery of 240V Window Air-conditioner machine having cooling capacity not less than 6300W, ISSER 2.80 to 3.35, BEE rating not less than 3 star, Noise level not more than 51db. This window Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant-R32/R410A (O-General model -AXGB22BBAA-B) | 5 | nos. | 43,250 ₹2,16,250 Lowest |
| 7.00 | Installation, testing & commissioning of the above-said window ACs incl. required work for placing the unit & mending good the damages as per direction of E.I.C. | 5 | nos. | 1,500 ₹7,500 Lowest |
| 8.00 | Supply & Laying 3/4"(20mm) hard PVC pipe (heavy type) for water drainage. | 90 | Mtrs | 72 ₹6,480 Lowest |
| 9.00 | Cutting holes and subsequent mending good damages.
Dia. Upto 150mm
In Brick work.[Cement-4.0 Kg/Mtr] [Item no.-12 of Page no.-12 of PWD Schedule of Rate for Building works-Vol-1 w.e.f 01/11/2017] | 9 | Mtrs | 200 ₹1,800 Lowest |
| 10.00 | Rendering the surface of walls and ceiling with plaster of paris
(thickness not less than 1.5 mm.) [Item no.-5 of Page no.-204 of PWD Schedule of Rate for Building works-Vol-1 w.e.f 01/11/2017] | 9 | Sqm | 200 ₹1,800 Lowest |
Tender Value
Refer Docs
EMD Value
₹9,500
Closing Date
28 Nov 2025, 1:00 pmClosed
AE/KRESD/PWDte
Office of The Assistant Engineer, Kolkata Raj Bhavan Electrical Sub Division, P.W.Dte., 2 Larkin Lane, Kolkata-700062
Replacement of old air conditioning machines(Split and Window type) at Prince of Wales Suite and Dufferin Suite at Main Building of Kolkata Raj Bhavan.
2025_WBPWD_941533_1
WBPWD/AEKRESD/NIQ23/25-26(2nd Call)
Open Tender
ELECTRICAL WORKS M/R
Item Rate
15 days
Kolkata Raj Bhavan
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,500
27 Feb 2026
7 Nov 2025
1 Dec 2025
8 Nov 2025
28 Nov 2025
8 Nov 2025
Amount
Supply & delivery of Non-Inverter type split Air-conditioner machine having cooling capacity not less than 7625W,ISSER 3.8 to 4.39,BEE rating not less than 3 star, Noise level not more than 50db. This Split Air Conditioning machine fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant- R32/R410A. (Mitsubishi Heavy Industries model No. SRK25CSS – S6/A).
Installation, testing & commissioning of the above-said split AC outdoor unit by fixing iron angle unit on wall & mending good the damages as per direction of E.I.C.
Supply & Installation of Extra Add-on items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC.
Supply & laying 1.1KV grade 3 core 4 sqmm flexible copper Cable with screw, saddle,drill machine nut bolt etc all necessary items needed for connection. (from starter to A.C outdoor Connection)(Make- Finolex/Havells/Polycab/Gloster as approved by E.I.C)
Supply & Laying of 4core 1.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/Polycab as approved by E.I.C)
Supply & delivery of 240V Window Air-conditioner machine having cooling capacity not less than 6300W, ISSER 2.80 to 3.35, BEE rating not less than 3 star, Noise level not more than 51db. This window Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant-R32/R410A (O-General model -AXGB22BBAA-B)
Installation, testing & commissioning of the above-said window ACs incl. required work for placing the unit & mending good the damages as per direction of E.I.C.
Supply & Laying 3/4"(20mm) hard PVC pipe (heavy type) for water drainage.
Cutting holes and subsequent mending good damages. Dia. Upto 150mm In Brick work.[Cement-4.0 Kg/Mtr] [Item no.-12 of Page no.-12 of PWD Schedule of Rate for Building works-Vol-1 w.e.f 01/11/2017]
Rendering the surface of walls and ceiling with plaster of paris (thickness not less than 1.5 mm.) [Item no.-5 of Page no.-204 of PWD Schedule of Rate for Building works-Vol-1 w.e.f 01/11/2017]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. connections [PWD/SOR(Elect)- E-17/5(b)]
Add. G.S.T.@ 18% on total value.
Add. LWC.@ 1% on total value
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.00 MB
BOQ_2228657.xls
BOQ • 0.23 MB
2911_ii.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .