Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L1 | Accepted-AOC Found in Order Lowest Bidder | |
| 2 | L2₹28.5 L+₹3.3 L (13.0%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest bidder |
Tender Value
Refer Docs
EMD Value
₹55,000
Closing Date
8 May 2021, 6:00 pmClosed
GE 874 EWS C/O 56 APO
GE 874 EWS C/O 56 APO
PROVN OF LT PANELS FOR ELECT OPTIMIZATION AT DRUGMULLA AND PROVN OF 10X HOT AND COLD ACs AT 168 MH UNDER GE 874 EWS
2021_MES_436006_1
GE 874/EWS-03/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 874 EWS C/O 56 APO
As per NIT and tender documents
6 documents required · 6 mandatory
₹500
GE 874 EWS
₹55,000
Yes
2 Jun 2021
12 Apr 2021
10 May 2021
12 Apr 2021
8 May 2021
26 Apr 2021
12 Apr 2021 - 20 Apr 2021
Amount
E/M Portion
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars of Amps rating as specified, installed on polymer insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally and internally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with two layers of Sheet Metal Cover (should have one set of doors on inside and one set of doors outside), capable of withstanding snow and rain at installation site with maintainence proof design, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, having one chamber with door for each MCCB, having two empty chambers for future use, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size incl the provision of space to accommodate the under mentioned items. The cable coming in and out of the Panel will be laid in specially made PCC/ Brick Masonry Trenches/ Ducts of 30cm x 30 cm with sand cushioning till top and RCC/ Cast Iron lid cover for the trenches. The scope of work includes the following:-
(a) Incoming (i) MCCB 4 pole, 415 volts AC grade, 300 Amps rating and 36 KA rupturing capacity complete with microprocessor based OL protection - 01 No E15. (b) Outgoing (i) MCCB 4 pole, 415 volts AC grade, 100 Amps rating and 35 KA rupturing capacity complete with microprocessor based OL protection - 01 Nos (ii) MCCB 4 pole, 415 volts AC grade, 63 Amps rating and 35 KA rupturing capacity complete with microprocessor based OL protection - 04 Nos. (c) Digital volt meter 3 phase class1 Make HPL NPAMEBRITV31 - 01 Nos. (d) Digital ammeter 3 phase class1 Make HPL cat No NPAMEBRITA31 - 01 Nos. (e) Indicator lamp R Y G B Make Havells -01 set.
(f) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road/ ground/ floor level. (g) Trivector LCD Multifucntional panel type energy meter, with tamper detection, output for data saving and data logging Model Secure Elite 440 series or equivalent in L&T / HPL - 01 Nos. (h) Secure 3Phase, 1 Element, 4 Wire 440 V Digital Power Factor Meter - 01 Nos. (j) Current Transformer -01 Nos. Note: (i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars of Amps rating as specified, installed on polymer insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally and internally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with two layers of Sheet Metal Cover (should have one set of doors on inside and one set of doors outside), capable of withstanding snow and rain at installation site with maintainence proof design, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, having one chamber with door for each MCCB, having two empty chambers for future use, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size incl the provision of space to accommodate the under mentioned items.
The cable coming in and out of the Panel will be laid in specially made PCC/ Brick Masonry Trenches/ Ducts of 30cm x 30 cm with sand cushioning till top and RCC/ Cast Iron lid cover for the trenches. The scope of work includes the following:- (a) Incoming (i) MCCB 4 pole, 415 volts AC grade, 300 Amps rating and 36 KA rupturing capacity complete with microprocessor based OL protection - 01 No E15. (b) Outgoing i) MCCB 4 pole, 415 volts AC grade, 100 Amps rating and 35 KA rupturing capacity complete with microprocessor based OL protection - 01 Nos. (i) MCCB 4 pole, 415 volts AC grade, 63 Amps rating and 35 KA rupturing capacity complete with microprocessor based OL protection - 03 Nos. (c) Digital volt meter 3 phase class1 Make HPL NPAMEBRITV31 - 01 Nos. (d) Digital ammeter 3 phase class1 Make HPL cat No NPAMEBRITA31 - 01 Nos. (e) Indicator lamp R Y G B Make Havells -01 set
(f) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road/ ground/ floor level. (g) Trivector LCD Multifucntional panel type energy meter, with tamper detection, output for data savingand data logging Model Secure Elite 440 series or equivalent in L&T/ HPL - 01 Nos. (h) Secure 3Phase, 1 Element, 4 Wire 440 V Digital Power Factor Meter - 01 Nos. (j) Curreent Transformer -01 Nos Note : (i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint..
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars of Amps rating as specified, installed on polymer insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally and internally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with two layers of Sheet Metal Cover (should have one set of doors on inside and one set of doors outside), capable of withstanding snow and rain at installation site with maintainence proof design, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, having one chamber with door for each MCCB, having two empty chambers for future use, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size incl the provision of space to accommodate the under mentioned items.
The cable coming in and out of the Panel will be laid in specially made PCC/ Brick Masonry Trenches/ Ducts of 30cm x 30 cm with sand cushioning till top and RCC/ Cast Iron lid cover for the trenches. The scope of work includes the following:- (a) Incoming (i) MCCB 4 pole, 415 volts AC grade, 200 /250Amps rating and 36 KA rupturing capacity complete with microprocessor based OL protection - 01 No. (b) Outgoing (i) MCCB 4 pole, 415 volts AC grade, 100 Amps rating and 35 KA rupturing capacity complete with microprocessor based OL protection - 01 Nos (ii) MCCB 4 pole, 415 volts AC grade, 63 Amps rating and 35 KA rupturing capacity complete with microprocessor based OL protection - 04 Nos. (c) Digital volt meter 3 phase class1 Make HPL NPAMEBRITV31 - 01 Nos (d) Digital ammeter 3 phase class1 Make HPL cat No NPAMEBRITA31 - 01 Nos (e) Indicator lamp R Y G B Make Havells -01 set
(f) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road/ ground/ floor level. (g) Trivector LCD Multifucntional panel type energy meter, with tamper detection, output for data savingand data logging Model Secure Elite 440 series or equivalent in L&T/ HPL - 01 Nos (h) Secure 3Phase, 1 Element, 4 Wire 440 V Digital Power Factor Meter - 01 Nos (j) Current Transformer -01 Nos Note : (i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars of Amps rating as specified, installed on polymer insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally and internally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with two layers of Sheet Metal Cover (should have one set of doors on inside and one set of doors outside), capable of withstanding snow and rain at installation site with maintainence proof design, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, having one chamber with door for each MCCB, having two empty chambers for future use, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size incl the provision of space to accommodate the under mentioned items.
The cable coming in and out of the Panel will be laid in specially made PCC/ Brick Masonry Trenches/ Ducts of 30cm x 30 cm with sand cushioning till top and RCC/ Cast Iron lid cover for the trenches. The scope of work includes the following:- (a) Incoming (i) MCCB 4 pole, 415 volts AC grade, 200 Amps rating and 36 KA rupturing capacity complete with microprocessor based OL protection - 01 No E15 (b) Outgoing (i) MCCB 4 pole, 415 volts AC grade, 100 Amps rating and 35 KA rupturing capacity complete with microprocessor based OL protection - 02 Nos (ii) MCCB 4 pole, 415 volts AC grade, 63 Amps rating and 35 KA rupturing capacity complete with microprocessor based OL protection - 02 Nos (c) Digital volt meter 3 phase class1 Make HPL NPAMEBRITV31 - 01 Nos (d) Digital ammeter 3 phase class1 Make HPL cat No NPAMEBRITA31 - 01 Nos (e) Indicator lamp R Y G B Make Havells -01 set
(f) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road/ ground/ floor level. (g) Trivector LCD Multifucntional panel type energy meter, with tamper detection, output for data savingand data logging Model Secure Elite 440 series or equivalent in L&T/ HPL - 01 Nos (h) Secure 3Phase, 1 Element, 4 Wire 440 V Digital Power Factor Meter - 01 Nos (j) Current Transformer -01 Nos Note : (i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars of Amps rating as specified installed, on polymer insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally and internally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with two layers of Sheet Metal Cover (should have one set of doors on inside and one set of doors outside), capable of withstanding snow and rain at installation site with maintainence proof design, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, having one chamber with door for each MCCB, having two empty chambers for future use, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size incl the provision of space to accommodate the under mentioned items.
The cable coming in and out of the Panel will be laid in specially made PCC/ Brick Masonry Trenches/ Ducts of 30cm x 30 cm with sand cushioning till top and RCC/ Cast Iron lid cover for the trenches. The scope of work includes the following:- (a) Incoming (i) MCCB 4 pole, 415 volts AC grade, 160 Amps rating and 36 KA rupturing capacity complete with microprocessor based OL protection - 01 No E15 (b) Outgoing (i) MCCB 4 pole, 415 volts AC grade, 63 Amps rating and 35 KA rupturing capacity complete with microprocessor based OL protection - 03 Nos (c) Digital volt meter 3 phase class1 Make HPL NPAMEBRITV31 - 01 Nos (d) Digital ammeter 3 phase class1 Make HPL cat No NPAMEBRITA31 - 01 Nos (e) Indicator lamp R Y G B Make Havells -01 set
(f) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road/ ground/ floor level. (g) Trivector LCD Multifucntional panel type energy meter, with tamper detection, output for data savingand data logging Model Secure Elite 440 series or equivalent in L&T/ HPL - 01 Nos (h) Secure 3Phase, 1 Element, 4 Wire 440 V Digital Power Factor Meter - 01 Nos (j) Current Transformer -01 Nos Note : (i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core, burried in trenches/ floor/ Walls/ Ducted/ in GI Pipes complete including cutting/ chasing to any surface and making good distrubed surface to match existing surface.
All as per item No. 6 above but cable of size 70 sqmm 3.5 core.
Excavation in trenches in any type of soil n exc 1.5m deep and not exc 1.5m wide for laying of under ground cable, electric pole and getting out complete all as directed.
Returning filling in including spreading leveling watering and well ramming 25cm in thickness in any type of soil.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
M&L for dry sand cushioning to under ground cables provided with a layer of sand 8 cm deep before laying the cable, 15 cm depth after laying cable & stretching the cable all as specified and directed.
Supply and lay brick class ‘B’ covering as mechanical protection to cable with well burnt all as specified by engineer in charge.
GI water tubing 40mm bore 'Light grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches or fixed to poles complete all as specified and as directed.
Supply, Installation and Testing Hot & Cold, Invertor Split type Air Conditioner, electric driven, Single Phase, 240 volts, Five Star BEE Rating with Remote Control System, capacity 2.0 Tonnes, with in-built air ioniser and plasma filter for better indoor air quality including necessary wiring and making fixing arrangement for indoor and outdoor unit complete all as specified and as directed. Note : The Split AC shall be fitted all as directed at site. The contractor shall make arrangement for cutting chases for laying gas pipes including supply and fixing the copper gas pipes from the indoor unit to the outdoor unit and making good the disturbed surface to match the existing surface. The quoted rate of the contractor shall be deemed to be inclusive of this provision.
Supply, Installation, testing and commissioning of Voltage stabilizer for automatic operation, single phase naturally air colled indoor type & designed for input varition between 90V to 300 V with output voltage stabilized at 230 V with accuracy of +_ 2.5%, 4-6 Sec initial delay and of capacity 6.6 KVA / 30 A Make V Guard Model No VGMW1000PLUS OR equivalent as approved by Engr-in-charge
Point wiring for 3 pin socket outlet 15 Amps on the independent board controlled by one switch with 4.00 sqmm PVC FR insulted un-sheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC FR insulted un-sheathed copper conductor single core multi stranded flexible cable as earth lead (using colour coding) in and including cable 1100 volts grade including casing and capping (ISI marked) for one light/fan point including 2nd class hard wood rectangular block open recessed cover with 3mm thick plastic laminated sheet cover including cutting chases to wall making good the distrubed surfaces to match with the existing specification complete all as specified.
Modular DB box with sheet metal enclosure for AC including plug, socket and MCB of 25 Amp rating. Make havells (DBOXx MCB Protacted socket)
Submain wiring with two single core 6 Sqmm PVC FR insulated and unsheathed 1100 volts grade stranded copper conductor ISI Marked drawn into & including medium grade PVC conduit /casing capping, with wooden/white color casing capping (as specified and directed) 25 mm dia with all fittings and accessories and continuous run of one single core PVC FR insulated unsheathed flexible copper conductor cable green colour of size 4 Sqmm as earth lead in & including PVC casing and capping/ conduit (not less than 25 mm outer dia) with all fittings and accessories fixed concealed/surface including taking down old unserviceable sub main wiring and making good surfaces to match with existing specification all as required at site complete all as specified and directed by Engr-in- charge. Make of cable - Havells/Plaza/Policab and Make of Casing capping - Polyplast/Pressfit/Presto plast
M/S ABDUL AZIZ MIR
Bidder Name
FG CONSTRUCTION
M/S ABDUL AZIZ MIR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .