Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC 66 RISHI VIHAR PHASE II MAJITHA ROAD AMRITSAR | AMRITSAR | AMRITSAR | PUNJAB | ₹1.0 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹1.0 CrRejected-AOC | ₹1.0 Cr | L2 | Rejected-AOC Reject |
| 3 | L 3₹1.1 CrRejected-AOC | ₹1.1 Cr | L 3 | Rejected-AOC Reject |
| 4 | L4₹1.2 CrRejected-AOC GURDASPUR | GURDASPUR | GURDASPUR | PUNJAB | ₹1.2 Cr | L4 | Rejected-AOC Reject |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
29 Jan 2026, 1:00 pmClosed
Executive Engineer Provincial Division Amritsar
Executive Engineer Provincial Division Amritsar
Repair and Maintenance Civil Works in District Institute of Education and Training Verka Amritsar DIETs as centre of Excellence Year 2025-26
2026_CEPW_157860_2
EE/PD/Asr/85 dated 09-01-2026
Open Tender
Civil Works - Buildings
90 days
Amritsar
Please refer Tender documents.
16 documents required · 16 mandatory
₹10,000
Yes
₹2.8 L
Yes
18 Feb 2026
15 Jan 2026
29 Jan 2026
15 Jan 2026
29 Jan 2026
15 Jan 2026
CIVIL WORK
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
Extra for additional storey upto 4 metres above the top of structural roof of lower storey.
12.5mm thick cement plaster 1:4.
Reinforced cement cocrete M-20 Mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Extra for R.C.C. work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey.
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Extra for shuttering in each subsequent storey above the first. Storey (except for item No.9.16)
Cold twisted deformed (ribbed/ tor steel) Bars Fe 500 grade as per IS 1786-2008 for R.C.C. works, where not included in the complete rate of R.C.C. including bending, binding, and placing in position complete.
Extra for work done in each subsequent storey above the first storey for item No.18.17, 18.18 and 18.19
Cement Concrete 1:8:16 with 40mm guage stone aggregate
Cement Concrete 1:2:4 with stone ballast of size.
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.)
Providing and fixing mineral fibre false ceiling tiles at all heights With 16 mm thick beveled tegular mineral fibre Anti-microbial false ceiling tile of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
Providing and fixing anodised aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections conforming to IS : 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer-in-charge
Prelaminated particle board with decorative lamination on Both side.
Providing & fixing glazing in aluminium door, window, ventilator shutters and partitions etc. (i) With float glass panes of 5.5 mm thickness.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.
Kail wood doors shutter and window shutter panelled, glazed or glazed and panelled including hinges screws chokes cleats and cords etc. complete Fixed in position (Single Leaf
Wire gauze door shutter with Kail wood without springs housed in chowkats (Single Leaf)
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect Glazing area above 0.09 sqm
5.0mm thick Plate glass (INDIAN)
Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect
Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement sand mortar 1:4 and top surface to be left clear after wire brushing etc.
Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded).
Applying bitumen on roof including heating and carrying to roof.
Cost of new Brick tile
Cement concrete 1:2:4 gola 10 cm. x 10 cm. quardrant along junction of roof with parapet wall finished smooth, where specially specified.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Bottom Khurra on ground 1.2m x 0.6m Mtr. Consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3.
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
Cement Concrete 1:8:16 with 40mm guage stone aggregate
Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M- 35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in- Charge.
Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours.
Scraping of White wash and colour wash complete in all respect as per PWD specifications
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.as per PWD Specification No.16.11
Painting two coats excluding priming coat with synthetic enemal paint using special quality paint in all shades on new wood work / metal work surface to give an even shade
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
PUBLIC HEALTH
Providing and fixing of Split Type Air Conditioning unit with inverter Technology of 2.0 TR Capacity 5 star Rating for 230 Volts single phase supply with nature friendly refrigerant R-32 or equivelant capable of performing the following funcaitons :- (i) Cooling (ii) Dehumidirying (iii) Air Circulation (iv) Filtering including installation charges complete in all respect. (Make Diakin, L.G. Blue Star, Voltas, Carrier or equivelant)
Providing and fixing of Split Type Air Conditioning unit with inverter Technology of 1.5 TR Capacity 5 star Rating for 230 Volts single phase supply with nature friendly refrigerant R-32 or equivelant capable of performing the following funcaitons :- (i) Cooling (ii) Dehumidirying (iii) Air Circulation (iv) Filtering including installation charges complete in all respect. (Make Diakin, L.G. Blue Star, Voltas, Carrier or equivelant)
AUTOMATIC VOLTAGE STABLIZER: Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- Automatic Voltage Stablizer 4 KVA
Automatic Voltage Stablizer 5 KVA
Providing & fixing New MCB 40 Ampere with Protection cover of reputed make.
Interconnecting Heavy Duty copper pipe line from indoor to outdoor unit with insulation and cable connection.
Providing & fixing outdoor unit stand
Providing and fixing PVC Drain pipe including specials such as tee, bends, sockets, elbow clamps etc. PVC pipe 4 Kgf/cm2 25mm i/d
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. Through wall 22.86 cm thick
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.,:- 3 Pin Plug Top 25Amp. (ISI marked)
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge: Overall size 4sq.mm (Un-sheathed)
RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module),coveredwithFramePlateand other pettymaterial etc. including the cost of above material, cutting and filling up of chases (with finishing the surface): Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1 No. Motor starter 25Amp. erected at switch board height.
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415volts 50 cycles AC supply with breaking capacity of 10kA,Curve-Cand lowwatt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs: MCB Double Pole 6-32amp. (10 kA,Curve C)
Providing & fixing in position Commercial RO without reservoir with four no cartridge/membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
Providing& fixing in position Water Cooler withoutStablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. Water Cooler Full Steel Body 60/80 ltr Capacity without Stablizer
Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. 6 Kg. Capacity
Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. 4.5 Kg. Capacity
Prov. and fixing of FIRE EXTINGUISHER, Mechanical Foam Type 9ltr IS: 15683 Stored Pressure type complete with all accessories as per Manufactures Specification. ISI Mark of approved make complete in all respect.
Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) 30.1 consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Chinaware Floor Mounted One Piece EWC rim less type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) size 69x36x74 cm with P trap or S trap and seat cover complete in all respect.
Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing jet spray with 2'-6" long PVC pipe. a) With C.P. Brass nut
Providing and fixing Stainless steel health faucet complete in all respect.
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
C.P. brass 15mm Concealed stop cock with flange.
C.P. brass 15mm Angle valve without flange
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect.
PVC tube connection of size 15mm x 450 mm with C.P. Brass nut
Providing and fixing in position Vitreous Chinaware white urinal with concealed or in built P-trap (size 310 x 370 x 640mm)with built in water seal, outlet to wall and water inlet from back of approved make (to the approval of Engineer-in-charge) complete in all respect.
Providing and fixing partition for different type of urinals. Toughned Glass Partition 8mm thickness size 450 x 900 mm C/S
Providing and fixing in position C.P. brass bottle trap 32mmdiawith 40mm seal of approved make (to the approval of Engineer-in-charge) complete in all respect.
Providing and fixing PVC waste pipe 32mm complete in all respect.
Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects.
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. Size 75 mm x 75 mm
Providing and fixing Exhaust Fan
Providing & Fixing in postion liquid soap container of approved make (to the approval of Engineer-in-charge ) complete in all respect.Acrylic liquid soap container
Providing and fixing Looking Glass Bevelled edge with studs size 7'x2'
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in withrawl plugs 50mm, C.P.brassscrews and washers and S/S Studs on top completeinall respect (as required by the Engineer-in- Charge) Size 600mmx450mm
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. C.P. brass towel Rails size15mm dia 610mm long
C.P brass towel ring
Providing and fixing designer wall tiles of size 1200x600mm
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand),complete. Size 600x600 mm
12.5 mm thick cement plaster 1:4
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggre gate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material
Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness
Providing and fixing mineral fibre false ceiling tiles at all heights upto 4 mtr. of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized@120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-hape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.
With 16 mm thick beveled tegular mineral fibre Anti-microbial false ceiling tile confirming to ISO 5 (class 100) specifications
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, withone step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. SDR 11 CPVC pipes & fittings 20mm o/d
CPVC SDR 11 Pipe & fitting 25 mm o/d
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 110mm o/d single socket SWR UPVC pipe lines laid complete
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS- 14735 including cutting and wastage etc.cutting holes in walls roofs or floors etc. andmaking good to its original conditionbut excluding cost of lead joining. For 110mm o/d pipes Single Tee
Door Elbow 90 Degree (All side socketed)
Elbow 90 Degree (All side socketed)
Coupler
P Trap/Floor Trap 110mm x 110mm
Single Y-Junction
Providing and laying, jointing, fixing and testing ISI Marked Upvc Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. uPVC Pipe 10 Kgf/cm2 40mm i/d
Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.
Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.
Providing and fixing PVC Cistern 10 Ltr. Capacity ISI marked IS 7231:1994( size 32.5x47.6x15.5cm)of approved make (to the approval of the Engineer-in-charge) including PVC fittings complete.
Dismantling Sanitary fixtures such as Eurpoean/Indian/Orissa W.C., PVC /China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100Mtr. complete in all respect as required by Engineer-in-Charge. Eurpoean/Indian/Orissa W.C.,
Wash Hand Basin / Urinal Pot
CP Bib Cock/Angle Cock/Stop Cock/Shower/Bottle Trap
Wall mixer / Sink Mixer / Basin Mixer /Concealed Stop Cock
Bathroom Assessories such as Soap Dish, Towel Rail, Towel Ring, Towel Bracket, Mirror, Toilet Paper Holder, Seat Cover, Jet Pressure and all other accessories.
Providing and fixing LED Lights 32Watt. Size 595mm x 595mm
Providing and fixing Tube Lights 20Watt.
Providing and fixing hand Dryer
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge) under various fixtures complete in all respect.
Providing & Fixing in position C.P. Brass extension piece 25mm long to100mm long of approved make (to the approval of Engineer-in-charge) with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long
Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge) complete in all respect.
Providing & Fixing in postion15mm i/d bib cock of approved make (to theapproval of Engineer-in-charge ) complete in all respect. C.P. brass Bib cock long nose/long body foam flow without flange
Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge) fixed intow all with C.P brass screws complete in all respect. C.P. brass toilet paper holder
Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. Vertical type 15 litre capacity water heater
Providing and fixing in position C.P brass Single Lever basin mixer without Popup waste with 450mm Long Braided Hoses approved make (to the approval of Engineerin-charge) complete in all respect.
Providing&placing inpositionon terrace (at all floor levels) HDPE water storage tanks of approved make (to the approva lof Engineer in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks ( 2000 ltr.x 2 No. =4000 ltr.)
Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball 25mm i/d
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. G.I. tank nipple 25mm i/d
Providing and fixing in position vitreous chinaware white lavatory suites of approved make(to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115 mm long without CP fittings complete in all respect. Size 550 mm x 400 mm x 815 mm
Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. Vitreous chinaware standard white pedestal for wash hand basin.
Providing & fixing 15 mm C.P brass laboratory cock swan neck of approved make (to the approval of Engineer-in-charge ) complete in all respect. Laboratory cock swan neck One Way
Providing and fixing Designer Vanity made with MDF board including wash basin having Size 630 mm x 450 mm x 830 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.
Water proofing of wetare as(Concrete/Masonary Surface) and any water retaining structures such as swimming pools, water tanks, Bathrooms, toilets, balconies, planters etc with high performance polymer modified cementitionous coating (DR. FIXIT FASTFLEX/ Equivalent ) to provide tough film build-upand highly elastic film formation, which accommodates thermal movements soas toprovide seamless coating without any joints top revents water leakage.The scope of work also includes surface prepration and cleaning, washing and removing dust, dirtand loose particles from concrete/ masonary surface complete in all respects.
LANDSCAPING
Supplying at site of work good quality top soil, free from debris and weeds, from approved site of work with 5 km lead. (CSR 32.2)
Excavation in dumped stone or malba including stacking of unserviceable material separately and disposal of unserviceable material. Lead up to 50 m and lift up to 1.5 m, disposed material to be neatly dressed in all kinds of soils.(CSR 32.4 a)
Digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed farm yard manure @ 30% of pit volume and insecticide for termite control. CSR 32.13. 0.75mx0.75mx0.75m=0.42 cum
Planting specimen plants in prepared pits and watering. CSR 32.20
Digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed farm yard manure @ 30% of pit volume and insecticide for termite control. CSR 32.13. 0.60mx0.60mx0.60m=0.216 cum
Planting ground covers (special) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row.CSR 32.28
Providing earthen pots at site of work, filling with mixture of screened manure, good earth and cocopeat in the ratio 2:1:1 as specified. 30 cm size of pots filled to full volume. CSR 32.37 d
Supplying pot plant in 30 cm pots with plastic plate for indoor display at site of work. In earthen pot. CSR 32.43 d
Supplying seasonal flowers in earthen pots at site of work, as specified by Engineer-in-charge. Planting and supplying seasonal plants in flowering stage in 25 cm size of pots.CSR 32.40
Supply and installation of garden bench Chair type garden bench with L-shaped sides made of reinforced concrete (M- 30), thickness 100 mm, overall height 1000 mm, base width 620 mm. Back and seat shall consist of 5 Nos. reinforced concrete planks 1500 mm x 100 mm x 50 mm one plank 1500 mm x 200 mm x 50 mm. Seating height of the bench shall be 450 mm. The bench shall be fixed with nuts on concrete mount, all holes sealed after assembly and installation. (CSR 32.57 a)
Providing cement pots at site of work, filling 2/3rd volume with mixture of good earth and screened manure and cocopeat in the ratio 2:1:1.60 cm size of pots.CSR 32.38 e
Supplying specimen pot plant in 45 cm cement pots for outdoor display at site of work.CSR 32.49
ELECTRICAL WORK
RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories).
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring call-bell point
Wiring 6Amp. wall socket point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 16/20Amp. power plug control point
REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPE ACCESSORIES) Derived from 34.01: Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01)
Wiring fan point (With fan box)
Wiring light point
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
Overall size 4sq.mm (Un-sheathed)
Overall size 6sq.mm (Un-sheathed)
Overall size 10sq.mm (Un-sheathed)
Overall size 16sq.mm (Un-sheathed)
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed)
XLPE INSULATED LT CABLES: XLPE INSULATED ARMOURED CABLES (UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:-
Overall size 70sq.mm (3½ Core) Armoured (Underground)
Overall size 240sq.mm (3½ Core) Armoured (Underground)
XLPE INSULATED ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
Overall size 70sq.mm (3½ Core) Armoured (Loose)
Overall size 240sq.mm (3½ Core) Armoured (Loose)
XLPE INSULATED ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-
Overall size 70sq.mm (3½ Core) Armoured (On-Surface)
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)
Double Walled Corrugated HDPE Pipe 120/ 103.5mm (Outer/ Inner dia.)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 50, 63amp. (10kA, Curve-C)
MCB Triple Pole 50, 63amp. (10kA, Curve-C)
MCB Four Pole 40amp. (10kA, Curve-C)
MCB Four Pole 50, 63amp. (10kA, Curve-C)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
SP&N Double Door Distribution Board 12 way each
TP&N Horizontal Double Door Distribution Board 4 way each
TP&N Horizontal Double Door Distribution Board 6 way each
TP&N Vertical Double Door Distribution Board 4 way each
G.I. EARTHING: Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).
Earthing with 7/12 S.W.G. (7/2.80mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length)
Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):-
Additional length G.I. wire 7/12 S.W.G. (7/2.80mm dia.) in 20mm dia. G.I. pipe (Flushed)
COPPER EARTHING: 8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
LT PANELS: LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.
MCCB's (FOR PANELS & SHEET ENCLOSURE): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 630amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
SHEET METAL IRON CLAD CHANGEOVER SWITCHES: Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications:-
IC Four Pole Changeover Switch 200amp., 415volts
COPPER EARTHING (Upto 8 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
Earthing with 25mm x 3mm Copper Tape (upto 8Metre in Length)
COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-
Additional Length 25mm x 3mm thick Copper Tape
Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3% with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory
Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3% with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory
Supply and erection of BEE 3-star rating AC Celling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body 3Nos of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos, of speeds. The product should have a manufcaturer's guarantee warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm comploto in all respects as per satisfcation of the Engineer In-charge at site.
Supply and erection of recessed mounted 36 WATT LED panel 2x2 (including constant LED driver) with CRACA sheet having efficency of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3% with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory
Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer ilfe including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at sile.
Less cost of credit of dismantelled material
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
SBDVERKA.pdf
Tender Documents • 20.78 MB
BOQ_320131.xls
BOQ • 0.68 MB
Download all tender documents and submit your bid