Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | L1 | Accepted-AOC Due to being L1 | |
| 2 | L2₹36.5 L+₹2.8 L (8.35%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-Finance other than L1 | |
| 3 | L3₹36.9 L+₹3.2 L (9.54%)Rejected-Finance | L3 | Rejected-Finance other than L1 | |
| 4 | L4₹37.3 L+₹3.6 L (10.5%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L4 | Rejected-Finance other than L1 | |
| 5 | L5₹37.8 L+₹4.1 L (12.1%)Rejected-Finance | L5 | Rejected-Finance other than L1 |
Tender Value
Refer Docs
EMD Value
₹75,000
Closing Date
14 Jan 2022, 6:00 pmClosed
GE UTILITIES UDHAMPUR
GE UTILITIES UDHAMPUR PO GARHI PIN 182121
Addition/Alteration to energy saving gate lights, post top lights, flood lights and connected work in Bikram park area and Special repair to external electrification works near Sappers Enclave at MPH under GE Utilities Udhampur.
2021_MES_495165_1
GE/U-60/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE UTILITIES UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹75,000
Yes
18 Feb 2022
16 Dec 2021
21 Jan 2022
16 Dec 2021
14 Jan 2022
31 Dec 2021
Amount
Supply, installation, testing and commissiong of LED post top lantern gate lights of 28Watt capacity including LED Warm lights with mordern look using new generation technology in LED suitable for pole of dia 60-65mm complete all as specified and dirtected by Engr-in-Charge. Make: Wipro cat part no LGTP04X028XW / Havells Cat No- ENDURASPRING6PT35WLED757PSYMTOTG or equivalent in Polycab/Crompton Greaves/HPL /Philips. Note : a) Necessary fixing arrangements like grouting, foundation and coping required for fixing of Post top lantern shall deemed to be included in quoted rates.
Supply, installation, testing and commissiong of new generation energy saving LED flood lights of 250 Watt capacity, powder coated PDC aluminium body with toughned glass visor fitted in frame, equiped with secondary optical lens for superior light distribution, efficacy > 110Lm/W with IP66 protection with 5700k complete all as specified and dirtected by Engr-in-Charge. Make : Polycab cat part no: PCGLF C3 01 250 HL-LFL, item code: PAR0209019 or equivalent in Polycab/ Crompton Greaves / HPL / Philips
PVC insulated three core, 2.5 Sqmm multi stranded copper conductor cable from junction box to light fittings complete all as specified and dirtected by Engr-in-Charge.
Supply, installation, testing and commissiong of new generation energy saving LED flood lights of 120 Watt capacity, powder coated PDC aluminium body with toughned glass visor. Efficancy > 100Lm/w with IP66 protection with 5700k complete all as specified and dirtected by Engr-in-Charge. Make : Polycab Cat No: PCGLF T1 01 120, item code: PAR0206012 or equivalent in Polycab/ Crompton Greaves / HPL / Philips.
Factory made sheet metal enclouser (junction box) made out of 3.15mm thick steel sheet, CRCA steel sheet powder coated, weather proof, out door type, with 30cm long legs with front openable including 4 strip aluminium bus bar of rating 100 amps suitable for one incoming and out going feeders, mounted on insulators including necessary thimbles/lugs of suitable sizes, necessary earth work and PCC foundation for grouting of four legs complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissiong of 10sqmm 2 core, LT UG heavy duty electric cable , XLPE, insulated, armoured with aluminium conductor 1100 volts grade of cross sectional area complete all as specified and dirtected by Engr-in-Charge.
Ornamental LED Retrofit Garden Light bollard made out of die cast aluminium/cast iron, elegant look, duly primer & painted antique colour finish complete all as specified and dirtected by Engr-in-Charge. Make:- Hi-Lite Model No: HL-138 or as approved by GE.
LED bollard lights of 10 watt capacity complete all as specified and directed by Engr-in-Charge. Make: Wipro Cat No- LBLDDSC010XW / equivalent in aPolycab/ Crompton Greaves / HPL / Philips Note: All junction boxes includes 4 pole Bus bar for distribution of supply from 1 bollard to another and necessary grouting for fixing of bollard shall deemed to be included in the quoted rate.
Factory made sheet metal enclouser (junction box), made out 3.15mm thick, CRCA steel sheet, powder coated weather proof, out door type with 60cm long legs 04 nos made out of equal angle iron of size 40x40x6mm, size of enclouser not less then 75x60x30cm depth with front and rear openable double door with locking arrangement incl 4 strip aluminium bus bar of rating 300 amps suitable for 1 incoming and 3 out going feeders, mounted on insulators including necessary thimbles/lugs of suitable sizes, necessary earth work and PCC foundation for grouting of four legs complete all as specified and directed by Engr-in-Charge. Incoming:- (a) MCCB 4 pole,Ics=100%Icu- 35 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos.
Supply, installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC1:2:4 type B-1 bocks of size15x15x20 cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable/openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz, factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equipments :-
(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 1000 amps for Phases and neutral - 01 set (b) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job (c) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 65 KA, 415 Volts, 630 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos.
Outgoing:- (a) MCCB 4 pole , Ics=100%Icu- 45 KA, 415 Volts, 400 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. (b) MCCB 4 pole , Ics=100%Icu- 38 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. (c) MCCB 4 pole , Ics=100%Icu- 38 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. (d) MCCB 4 pole , Ics=100%Icu- 26 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. (e) PCC 1:3:6 type C-2 for grouting 4 legs of feeder pillar box. Note :- (a) Various feeder shall be indicated by 50 mm high letter in white synethetic enamel paint. (b) PCC 1:3:6 type C-2 for grouting 4 legs of feeder pillar box.
Supply, installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels, complete,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equipments :-
(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 500 amps for Phases and neutral - 01 set (b) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job (c) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 55 KA, 415 Volts, 400 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos. Outgoing:- (a) MCCB 4 pole ,Ics=100%Icu- 38 KA, 415 Volts, 250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos. (b) MCCB 4 pole ,Ics=100%Icu- 26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos. (c) MCCB 4 pole ,Ics=100%Icu- 26 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos.
LED post top with aluminium enclosure, powered with high power LEDs as light source and die casted heat sink exhibits classic Victorian Lock with symmetrical light distribution and excellent heat dissipation for long life complete all as specified and directed by Engr-in-Charge. Make Havells Cat part No- JUPITERMAXIPT70WLED830PSYMTOPC/ Wipro cat part no LGTP02X030XW or equivalent in HPL/ Philips.
Supply, installation, testing and commissioning and testing of factory made and tested (CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compartmentalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete including taking down old U/S LT panel/busbar with following :- Incoming :- (a) MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps, with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. (b) MCCB 4 pole , Ics=100%Icu-35/36 KA, 415 Volts, 320 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos.
( c) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts,250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. ( e) On load change over switches 4 pole of capacity 400 Amps -01 Nos. (f) On load change over switches 4 pole of capacity 250 Amps -01 Nos. (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 600 Amp,4 pole - 01 set Outgoing :- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. (b) MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 160 Amps, with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. ( c) MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos.
Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level (iii) Outgoing MCCBs shall be fed with solid busbar connectors and Cables shall be terminated using gun metal /SS glands. (vi) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (v) cable glands for incoming LT cable 120 sqmm-03 Nos and out going cables 95 sqmm-03 Nos and 50 sqmm- 02 Nos are deemed to be included in quoted rate.
All as per serial item No.13 here-in-before but equipped with following accessories:- Incoming :- (a) MCCB 160 amps, 4 pole, 50Hz ,415 V with rupturing capacity 35/36 KA-01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 400Amp,4 pole, not less than 1 mtr long mounted on insulators 01 set Outgoing:- (a) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps, with thermal adjustable and fixed magnetic setting with extended terminals-02 Nos. (b) MCCB 4 pole, Ics=100%Icu-25/26 KA, 415 Volts, 63 Amps, with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos.
All as per serial item No.13 here-in-before but equipped with following accessories:- Incoming (a) MCCB 125 amps, 4 pole, 50Hz ,415 V with rupturing capacity 25/26 KA-01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 400Amp,4 pole, not less than 1 mtr long mounted on insulators 01 set Outgoing (a) MCCB 4 pole, Ics=100% Icu- 25/26 KA, 415 Volts, 100 Amps, with thermal adjustable and fixed magnetic setting with extended terminals-02 Nos.
All as per serial item No.13 here-in-before but equipped with following accessories:- Incoming:- (a) MCCB 160 amps, 4 pole, 50Hz ,415 V with rupturing capacity 35/36 KA-01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 400Amp,4 pole, not less than 75 cm long mounted on insulators 01 set Outgoing:- (a) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 125 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. (b) MCCB 4 pole , Ics=100%Icu-25/26 KA, 415 Volts, 63 Amps, with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos.
All as per serial item No.13 here-in-before but equipped with following accessories:- Incoming:- (a) MCCB 125 amps, 4 pole, 50Hz ,415 V with rupturing capacity 25/26 KA-01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 200Amp,4 pole, not less than 50 cm long mounted on insulators 01 set Outgoing:- (a) MCB DP, 415 Volts, 32 Amps, 10 KA-8
All as per serial item No.13 here-in-before but equipped with following accessories:- Incoming:- (a) MCCB 100 amps, 4 pole, 50Hz ,415 V with rupturing capacity 25/26 KA-01 No. (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 200Amp,4 pole, not less than 50 cm long mounted on insulators- 01 set Outgoing:- (a) MCB DP, 415 Volts, 32 Amps, 10 KA-3 Nos
All as per serial item No.13 here-in-before but equipped with following accessories:- Incoming:- (a) MCCB 100 amps, 4 pole, 50Hz ,415 V with rupturing capacity 25/26 KA -01 No Outgoing:- (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 200Amp,4 pole, not less than 75 cm long mounted on insulators -01 set
Supply, Laying and fixing (in replacement) along the poles or passing through pipes or laid under floor or through walls etc jointing and testing LT Cross Linked Polythene Insulated (XLPE insulated) galvanized steel strip armoured electric cable of size 10 sqmm, 2 core, 1100 volt grade, heavy duty, ISI marked with aluminium conductor and overall served with an outer sheath of PVC, of cross sectional area as under including taking out old UNSV LT cables complete all as specified and directed by Engr-in-Charge. (Note : Excavation, earthwork, Pipe for cable protection shall be measured and paid for separately)
All as per serial item no. 20.00 here-in-before but of size 35 Sqmm 3.5 core.
All as per serial item no. 20.00 here-in-before but of size 50 Sqmm 3.5 core.
All as per serial item no. 20.00 here-in-before but of size 70 Sqmm 3.5 core.
All as per serial item no. 20.00 here-in-before but of size 95 sqmm 3.5 core.
All as per serial item no. 20.00 here-in-before but of size 185 sqmm 3.5 core.
PVC insulated multi stranded copper conductor (in replacement) PVC cable sheathed 2.5 sqmm 3 core and making connections of street light fittings and bollards lights complete all as specified and directed by Engr-in-Charge.
Earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 32 x 6mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,common salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc., complete all as specified and directed by Engineer-in-charge. Note:- (i) All the joints shall be made with welding to get proper conductivity. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-Charge.
Earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25 x 4 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- (i) All the joints shall be made with welding to get proper conductivity. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Earthing with Copper earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to Copper strip 32 x 6 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- (i) All the joints shall be made with welding to get proper conductivity. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-Charge.
LED bollard with robust design and efficient garden lights of 10 watt capacity (in replacement), IP65 including taking down old UNSV garden lights complete all as specified and directed by Engr-in-Charge. Make:- CG Cat No LBLSR-10 CDL or equivalent in Philips or Wipro or Bajaj.
Plain cement concrete, M-15, type B-1 (using 20 mm graded stone aggregate) for coping of poles including dismantling of old broken PCC foundation complete all as specified and directed by Engr-in-Charge.
Acrylic sheet of size 6"x9" and 5mm thick (in replacement) including replacement of screw of size 1" as per sample suitable for garden light to fixing with pipe and fitting complete all as specified and directed by Engr-in-Charge.
Double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable laid to be under ground complete all as specified and directed by Engr-in-Charge. Make: REX/Tirupati Plastomatics Pvt Ltd.
Double walled corrugated (DWC) pipe of size 75 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable laid to be under ground complete all as specified and directed by Engr-in-Charge. Make: REX/Tirupati Plastomatics Pvt Ltd.
Double walled corrugated (DWC) pipe of size 50mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge. Make: REX/Tirupati Plastomatics Pvt Ltd.
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Supply and installation 16 No. Battery steel rack with UPS cabin complete all as specified and directed by Engr-in-Charge.
LED Green Flood light, 100 watt (in replacement) made uppressure diecast aluminium housing with toughned glass and high power LEDs and secondary lens with IP 66 protection system of efficasy >110 LPW including 10 KV SPD including taking down old UNSV flood lights complete all as specified and directed by Engr-in-Charge. Make :- CG/ Philips/ Wipro
FANGALIA TRADERS
PREM NATH KHAJURIA AND SONS
vijay kumar gupta and co
PAWAN KUMAR GOVT. CONTRACTORS
K S BUILDERS
MOHAN LAL AND SONS
proach associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .