Tender Value
₹2.5 Cr
EMD Value
₹3.3 L
Closing Date
20 Jul 2020, 6:00 pmClosed
CHIEF ENGINEER
HEADQUARTER CHIEF ENGINEER JAIPUR ZONE,JAIPUR
WIDENING OF THE ROAD AND CONNECTED WORKS AT BHARATAPUR MIL STN
2020_MES_349819_1
CEJZ/NIT/BPR-01 OF 2020-2021
Open Tender
Civil Works
Item Rate
270 days
BHARATPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE BHARATPUR
₹3.3 L
Yes
28 Aug 2020
4 Jun 2020
25 Jul 2020
4 Jun 2020
20 Jul 2020
15 Jul 2020
Amount
M&L for surface excavation n.exc. (Not exceedings) 30 cm deep and averaging 15 cm deep and getting out in hard / dense soil complete all as specified and directed.
M&L for removing excavated materials n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point in soils complete all as specified and directed.
M&L Soling with brocken Boulder or 150 mm thick qurried stone interstices filled surface formed & Rolled & Consolidated with 8 to 12 tonne power roller complete all as specified and directed.
M&L 15cm Thick compacted thickness WBM,with Coarse agg of Grading 2(63-40mm) or of Grading 3 (50-20mm) spread,rolled & Consolidated to gradient &camber required with 8 to 12 tonne power roller (lime stone ,flint or quartzite used) complete all as specified and directed.
M&L Preparing surfaces of Unsurfaced WBM, by brushing with wire brushes for removing cacked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc complete all as specified and directed.
M&L Rolling and cansolidated formation surfaces in cutting (8 to 12 tonne capacity) complete all as specified and directed.
M&L for applying evenly a priming/tack coat with bituminous primer using cold bituminous emulsion at 10 Kgs per 10 Sqm complete all as specified and directed.
M&L for preparing black top surfaces by brushing with wire brushes for removing caked mud etc,sweeping with brooms and finally fanning the clean surfaces with gunny bags to remove all loose dirt etc apply evenly a priming/tack coat paving bitumen with primer@ at 5Kg/10sqm with using cold bituminous emulsion complete all as specified
M&L Bituminous premix asphalitic semidense concrete 40 mm cansolidated thickness with 5.5% binder content by weight of total mix,rolled and compacted to required camber and gradient complete. Complete all as specified and directed.
M&L Premix bituminous, macadam mixed with paving bitumen 4% binder (Viscosity grade VG-30) contents any penetration laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less) with 8 to 10 Ton power roller complete all as specified and directed.
S&F Road stud(cateyes)globe of complete all as per manufacture specification and directed.
M & L for reflecting thermoplastic white/golden yellow,road marking paint confirming to BIS-3262,lay down through road marking machine in a layer CRYSTALEX and use of 5 KG material per sqm for lines,dashes,arrows,zebra marking etc by incorporating the white glass beds for reflectivity width complete all as specified and directed.
M&L Cement Concrete Type D-2, 1:4:8 40mm graded stone aggregate 100mm Thick complete alll as specified and directed.
M&L 25mm thick Fine Agg (sand) cushion for laying interlocking tiles complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block with gray cement and no pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete alll as specified and directed.
M&L factory made precast PCC solid block (1:2:4) type B-1 using 20mm graded stone aggregate as in kerb stone of size 300mmx150mmx150mm setting in cm (1:4) etc complete all as specified and directed.
Excavating in post holes ( or similar holes ) each n. exc 0.5 Cum , getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around , in layers n.exc 25 cm watering , removing surplues soil to a distance not exceeding 50mtr and making good surface complete alll as specified and directed.
M&L For PCC 1:3:6 Type C2 using 40mm grade stone aggregate as in foundation complete alll as specified and directed.
Supply and fixing mild steel screw bolts (machine made) n.exc 5cm and 5 to 10mm dia with hexagonal or square at one end and screwed the other each screwed to be fitted with washers and hexagonal or square nut complete alll as specified and directed.
M&L for broken stone or boulders in hardcore of gauge exc 63 mm but n exc 100 mm deposited spread and levelled in layers n. exc 15 cm thick watered and rolled/rammed to a true surface complete alll as specified and directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in flooring 40mm thick finished even and smooth with using extra cement complete alll as specified and directed.
M&L preparations of old painted steel surface and appling two coat of synthetic enamel paint over a coat of red oxide primer complete alll as specified and directed
Erected and fixing mild steel rolled section such as angles etc. as in purlins, rafter confirming to grade Fe 410-O or 310-O founded from the dismantling material of trusses obtained from item no 33& 34 of BOQ here-in-after all as specified and directed
Fixing only chain link fencing including line wires, any mesh size and type of standards rails straining bolts etc incl provision of binding wire complete all as specified and directed.
M & L removing excavated material exc. 50m and n exc 250m and depositing where directed at a level not exc 1.5 m above the starting point in soil complete all as specified and directed.
M & L removing excavated material exc. 250m and n exc 500m and depositing where directed at a level not exc 1.5 m above the starting point in soil complete all as specified and directed.
Demolition of brick work or stone/bolder masonary, built in cement mortar including all quions, arches, pillars,etc, but excluding ashlar facings, dressed stone work and precast concrete articles including removal of unserviciable material exc 50m but not exc 100m complete all as specified and directed.
Taking down Chowkat or frames with shutters (without taking off shutters frames of any size n.exc 1.5sqm and removing from site complete all as specified and directed.
Dismantaling of AC sheets corrugated , semi corrugated incl , ridges as in roof covering complete andincluding removal and fixed it other location as per Eng in charge direction complete all as specified and directed.
Demolition of cement concrete in groound floors & paving n, exc, 15 cm th , below or above ground floors complete all as specified and directed.
Taking up or down steel water tubing & connection & removing from site, 15 mm dia pipes complete. all as specified and directed
Taking up or down steel water tubing & connection & removing from site, 20 mm dia pipes completeall as specified and directed
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground and placed the post at other place as directed by Eng in Charge.
Dismentling framed trusses n exc 10 m and all trusses to be kept safely for refixing all as directd by Engr-in-charge.
Dismentling fencing wire mesh and removing of the same to a distance and placed it other place site all as specified and directed
Excavating in trenches, n. exc 1.5m wide and n exceeding 1.5 m in depth; for foundation,laying of cables & pipe lines etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and and getting outin soft/loose soil complete all as specified and directed.
Excavating in trenches, n. exc 1.5m wide and exceeding 1.5 m but n.exceeding 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and and getting outin soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm soft / loose soil complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for 150 mm bore reinforced cement concrete pipe , class NP-2 laid & jointed complete with collars in cm(1:1) with spun yarn & tested . Complete all as specified & directed.
Plain cement concrete 1:4:8 type D2 (Using 40mm graded crushed stone aggregates) as in bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150mm bore pipe complete all as specified and directed
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 mtr mean radius built in CM 1:4 complete all as specified and directed.
M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 with integral water proofing compound @ 3% of cement finished even and smooth without using extra cement complete all as specified and directed.
Supplying only integral water proofing compound complete all as specified and directed.
Providing precast cement concrete in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain with plain fair faces, including chamfers weatherings throating etc. and setting in mortar complete with joints to match, type B-1(20mm graded aggregate) Set in CM1: 4 complete all as specified and directed.
Mild steel bars TMT 10 mm dia and over, cut to length,bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conferming complete all as specified and directed.
All as per item no. 46 above but 6 mm to 8 mm dia , qualtiy conforming to Fe 290 Gde E-165 complete all as specified and directed.
Construction of soakage well 3.00 mtr dia and 3.00 mtr deep complete allas specified and shown on drawing.
Construction of septic tank for 50 users complete all as specified and shown on drawing.
Supply & spread unwashed dry river sand for sand cushioning and covering the under ground cable in trenches. (Note :- Punning thickness shall be measured.)complete all as specified and directed.
M&L for brick protection with sub Class`B` bricks old size laid dry, flat over cable perpendicular across the cable in trenches complete all as directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate in coping of existing/new poles / struts, posts etc including necessary form work, finished the exposed surfaces fair and even without using extra cement complete all as specified and directed.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this BOQ.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole/wall(including saddle clip) of the size 10 Sqmm 2 core complete all as specified and directed.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole/wall(including saddle clip) of the size 16 Sqmm 4 core complete all as specified and directed.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole/wall(including saddle clip) of the size 25 Sqmm 4 core complete all as specified and directed.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole/wall(including saddle clip) of the size 35 Sqmm 3.5 core.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole/wall(including saddle clip) of the size 50 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole/wall(including saddle clip) of the size 70 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole/wall(including saddle clip) of the size 95 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole/wall(including saddle clip) of the size150 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole/wall(including saddle clip) of the size 185 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole/wall(including saddle clip) of the size 240Sqmm 3.5 core complete all as specified and directed.
Supply & fix 60 watts LED street light fitings new generation energy saving ,environmental friendly ,long life,versatile pressure die cast aluminium IP66 with 10KV surge protection road way,luminaire with high power LED as light source with warranty option of 5 years and suitable drivers etc and connecting with 3 x 1.5 sq mm multistranded PVC insulated copper conductor with PVC Conduit 20mm dia from fittings to the jucntion box and fixing to complete all as specified and directed .make C G Cat part No:LSTP-60-CDL /Philips/Havells/Bajaj complete all as specified and directed.
Supply, install, test and commissioning factory made THERMOPLASTIC CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with terminal. Make Hansel Cat part No:KF 2525 G or equivalent make in /FIBOX(SOLID PC 2528 13G) complete all as specified and directed.
S&F street light GI bracket of 1.2 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of FL 40 x 6mm including nuts bolts & washers complete necessary fixing arrangements on pole as directed complete all as specified and directed.
Taking out old serviceable street light LED fitting carefully from existing PCC pole and refixing the same on new steel tubuler pole/ other location including conneting wire of 3 single core of 1.5 sqmm cPVC insulated stranded copper conductor as directed by Engineer-in-Charge at new location complete all as specified and directed.
Supply, install, commissioning and testing factory made (including CPRI type test certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated Aluminium bus bars 400 amps TPN rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/MCB & volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work.The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. Incoming (a) MCCB TPN 300 Amps 36 KA - 01 No. (b) Bus bar Al TPN 400 Amps - 01 Set. Out going- (a) MCCB TPN 200 Amps 36 KA - 01 No. for Loop out purpose (b) MCB SPN 40 Amp 240 Volt - 10 Nos Note: Space of out going MCCB 1 Nos to be provide and PCC platform shall be constructed all as specified.
Supply, install, commissioning and testing factory made (including CPRI type test certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated AL bus bars 600 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/MCB & volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work.The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. (Sub Panel -I) Incoming (a) MCCB TPN 350 Amps 36 KA - 01 No. (b) Bus bar Al TPN 600 Amps - 01 Set. Out going- (a) MCCB 250 Amp 4 Pole 35 KA - 1Nos (b) MCCB 63 Amp 4 Pole 35 KA - 3 Nos Note: Space of out going MCCB 1 Nos to be provide and PCC platform shall be constructed all as specified.
Supply, install, commissioning and testing factory made (including CPRI type test certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated AL bus bars 300 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/MCB & volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work.The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. Incoming (a) MCCB TPN 200 Amps 36 KA - 01 No. (b) Bus bar Al TPN 300 Amps - 01 Set. Out going- (a) MCCB TPN 160 Amps 36 KA - 01 No. for Loop out purpose (b) MCB SPN 40 Amp 240 Volt - 10 Nos Note: Space of out going MCCB 1 Nos to be provide and PCC platform shall be constructed all as specified.
M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strip 32mmx6mm
Dismantling of serviceable Steel tublar pole from site carefully and refixing the same at another location with necessary earth work as directed by engineer -in-charge. Note :- Earthwork and PCC work shall be measured and paid seperately.
Dismantling and taking down of existing street light fittings of any wattage or size from existing pole and deposited to MES store complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe up to 100mm dia complete all as specified and directed Note :- GI pipe shall be measured and paid in respective item of BOQ.
Supply & lay G I tubing 40mm bore light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc all as specified and directed.
Supply & lay G I tubing 80mm bore light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc all as specified and directed.
Supply & lay G I tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc for size 100mm bore complete all as specified and directed.
Supply and Fix cable route marker/indicator made out of GI iron angle of size 25x25x3 mm thick 60cm long for LT cable route marking embossed on GI circular plate 100mm dia duly painted with blue colour 3 mm thick including grouting in PCC 1:3:6 type C1 block concrete of size 20x20x20cm inclusive of necessary earth work all as specified and directed.
Dismantling of ACSR or ACC conductor complete all as specified and directed.
Dismantling of brackets of any size and type complete all as specified and directed.
Dismantling concrete poles/struts, any size complete all as specified and directed
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use within in 50m complete all as specified and directed.
Dismantling stay assembly complete, (demolition of concrete, etc. and excavation measured separately) complete all as specified and directed.
Shifting of old serviceable LT/HT cable from existing site to new site(of proposed road) carefully with necessary earth work as directed by engineer -in-charge. Note: Earth work,sand cushioning and brick protection will be measured under respective item of BOQ.
Dismantling insulators any type, any size complete all as specified and directed.
M&L earthing completewith galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of plate less than 2.25 mtr deep below normal ground level,connected with earthing lead of 4mm dia galvanised iron or steel wire, by means of nuts,bolts check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 15mm bore from earth electrode to test point incl provn of concerete pit in PCC (1:2:4) bype B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4kg/sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR part-I and connection to earth test point including testing on completion all as directed. Note :- The cost of 7.5m long galvanised iron earth 4mm diasteel wire size and protection pipe of 15mm bore GI medium grade is deemed to be included in quoted unit rate.
Taking up cast iron water mains (including all fittings), with spigot and socket ends and lead joints, sluice valves including burning out joints and recovering lead etc of size 250 mm dia complete all as specified and directed. Note:- Excavation and earth wrok shall be measured and paid seperately under respective item of BOQ.
Taking up cast iron water mains (including all fittings), with spigot and socket ends and lead joints, sluice valves including burning out joints and recovering lead etc of size 150 mm dia complete all as specified and directed. Note:- Excavation and earth wrok shall be measured and paid seperately under respective item of BOQ.
Taking up or down steel tubing and connections, sluice valves removal of size 80 mm dia complete all as specified and directed. Note:- Excavation and earth wrok shall be measured and paid seperately under respective item of BOQ.
Taking up or down steel tubing and connections, including removal of size 40 mm dia complete all as specified and directed. Note:- Excavation and earth wrok shall be measured and paid seperately under respective item of BOQ.
Taking up or down steel tubing and connections, including removal of size 20 mm dia complete all as specified and directed. Note:- Excavation and earth wrok shall be measured and paid seperately under respective item of BOQ.
Supply, laying in trenches, under floor, under road, connecting, jointing and testing ductile iron pressure pipe centrifugally cast ISI marked with socket and spigot ends confirming to IS-8329/2000 standard length of K-7 specification with outside zinc coating with bituminious finish layer complete of the size 100mm complete all as specified and directed . Note :- (i) Excavation and earth work will be measured and paid separately.
Supply, laying in trenches, under floor, under road, connecting, jointing and testing ductile iron pressure pipe centrifugally cast ISI marked with socket and spigot ends confirming to IS-8329/2000 standard length of K-9 specification with outside zinc coating with bituminious finish layer complete of the sizes 150mm complete all as specified and directed. Note :- (i) Excavation and earth work will be measured and paid separately.
Supply, laying in trenches, under floor, under road, connecting, jointing and testing ductile iron pressure pipe centrifugally cast ISI marked with socket and spigot ends confirming to IS-8329/2000 standard length of K-9 specification with outside zinc coating with bituminious finish layer complete of the size 250mm complete all as specified and directed. Note :- (i) Excavation and earth work will be measured and paid separately.
Cutting cast iron pipe of size 150mm dia and reducing to required length in position for insertion of new tees, branches, etc complete all as specified and directed
M&L of rubber gasket tyton joints to spigot and socket pipe of bore 100 mm dia complete all as specified and directed
M&L of rubber gasket tyton joints to spigot and socket pipe of bore 150 mm dia complete all as specified and directed
M&L of rubber gasket tyton joints to spigot and socket pipe of bore 250 mm dia complete all as specified and directed
S&F GI tubing medium grade ISI marked including all fittings laid in trenches / fixed on wall of size 20 mm bore all as specified and directed.
S&F of sluice valve 250 mm bore class PN-1.6 with flanged and iron wheel head, shut and open directed cast on it and including jointing materials, rubber gasket suitable size nut bolts and washer etc complete all as specified and directed.
S&F of sluice valve 150 mm bore class PN-1.6 with flanged and iron wheel head, shut and open directed cast on it and including jointing materials, rubber gasket suitable size nut bolts and washer etc complete all as specified and directed.
S&F of sluice valve 100 mm bore class PN-1 with flanged and iron wheel head, shut and open directed cast on it and including jointing materials, rubber gasket suitable size nut bolts and washer etc complete all as specified and directed.
M&L for construction of valve chamber of size 1200 x 1200 x 1000 mm with PCC (1:2:4) type B1 using 20 mm graded aggregate as in foundation 100 mm thick, brick masonary one brick thick wall in CM (1:4), coping with PCC (1:2:4) B1 type 50 mm thick,plastering internal and external walls upto 150mm below GL in cm (1:4), 50mm x 50mm x 6mm thick angle iron frame for chamber cover fixed with the chamber using 4 nos holdfasts made of 50 x 6 mm thick ms flat iron of suitable length ,mild steel chamber cover 4mm thick ,brazed with 50 x 6mm ms flats , fixed with handle made of 10mm dia MS bar suitably welded of 200mm length and locking arrangement , two coat cement based painting on plastered surfaces and two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces complete for chamber all as directed.
M& L Bends tapers any type, (straight, bend, increasing, decreasing or double socket etc). Tee pieces single branch "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of DI fittings upto 250 bore complete all as specified and directed
M&L of run lead joint to DI spigot and socketed pipe of bore 100 mm dia complete all as specified and directed
M&L of run lead joint to DI spigot and socketed pipe of bore 150 mm dia complete all as specified and directed
M&L of run lead joint to DI spigot and socketed pipe of bore 250 mm dia complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technology using suitable tools and machinery for laying of pipe upto 250mm pipe complete all as specified and directed.
M&L for MS casing pipe for protection of DI pipe at road crossing and including gas welding machine where necessary to required length with suitable thick conforming to Fe 410-0 or Fe- 310-0 complete all as specified and directed.
Cutting of existing road/PCC path for laying of pipes complete all as specified and directed
S&F of straight plain brass ferrules of size 25mm dia (or connecting screws) screwed both ends and including fixing and boreing on existing CI/DI pipe complete all as specified and directed.
Cutting of existing road/PCC path for laying of pipes complete all as specified and directed
Supply,install,testing and commisioning of LT panel box (KIOSK) out door type factory made CPRI approved plateform mounted suitable for 415 volts,3 phases ,4 wire ,50Hz AC supply system having bus bar chamber with insulated aluminium bus bar for 3 phases and neutral 400 Amps rated capacity installed on porcelain insulators. The panel shall be dust and vermin proof double door made out of 3.15mm thick CRCA MS sheet outer and inner and individual compartment for MCCB/ MCB & volts/Amps meter and 50 x 50x 6mm thick iron angle for base frame work. The complete feeder pillar box,panels should be powder coated including internal wiring With PVC insulated multistranded copper conductor FRLS cables appropriate size but not less than 4 sqmm. Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturer with 2 keys. Incoming (a) MCCB TPN 300 Amp 36 KA-01 No Outgoing (a) MCCB TPN 200 Amp 25KA - 01 No for loop out purpose (b) MCCB TPN 63 Amps 25KA - 03 Nos (01 No spare) (c) MCB SPN 40 Amps 240 Volts - 04 Nos Note: Space of out going MCCB 1 Nos to be provide and PCC platform shall be constructed all as specified.
M&L of PCC 1:4:8 type D-2, 40 mm graded aggregate in base / foundation of existing/new poles, posts etc. complete all as specified and directed.
AMIT RISHABH BUILDERS PRIVATE LIMITED
M/S Anil Enterprises
MADAN MOHAN JAIN sons
SINGH ENTERPRISES
Pioneer Enterprises
C P Singh and Co
m/s meetu enterprises
M/s R L PAREEK
Sood Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .