Financial Eligibility Criteria: (Ref: RB letter No. 2022/CE-I/CT/GCC- 2022/POLICY : Advance Correction Slip No.-1 dt 14.07.2022) The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The intending tenderers should possess a valid electrical contractor license at the time of opening of tender, issued by any state government & same should be submitted along with tender documents by all bidders including working contractors of this unit otherwise offer shall be summarily rejected....... IT SHOULD BE NOTED BY THE TENDERER THAT ELECTRICAL LICENSE UNDER RENEWAL AT THE TIME OF TENDER OPENING WILL NOT BE CONSIDERED AND OFFER WILL BE SUMMARILY REJECTED. IT IS THE RESPONSIBILITY OF TENDERER TO UPLOAD VALID ELECTRICAL CONTRACTOR LICENSE ON THE DATE OF TENDER OPENING.
All requisite documents mentioned in clause 3.7 of tender document attached pertaining to constitution of firm/concern. (As applicable).
34 conditions · 4 needing a document upload
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. THE TENDERER SHOULD UPLOAD VALID GST REGISTRATION CERTIFICATE ALONG WITH THE OFFER.
The tender shall comply with General Condition of contract (GCC),2022 of Indian Railways (file attached). and its latest amendment, if any. The tenderer shall submit the offer after duly satisfying himself/herself with the GCC,2022 in general.
Tenderers are required to upload the Bank details as per Annexure-XII (Real Time Gross Saving (RTGS)/National Electronic Fund Transfer (NEFT) Model Mandate Form)of tender document.
Tenderers are required to upload requisite details as per Annexure-VIIB (DETAILS OF CONTRACTUAL PAYMENT RECEIVED IN LAST THREE FINANCIAL YEARS AND CURRENT FINANCIAL YEAR) without which the offer is liable to be rejected.
Tenderers are compulsorily required to upload Affidavit as per Annexure-XXIV along with tender document, without which the offer will be considered incomplete and will be rejected summarily.
All requisite documents/credentials mentioned in clause 3.5 of tender document attached pertaining to his/their technical and financial eligibility. (As applicable).
All requisite documents mentioned in clause 3.7 of tender document attached pertaining to constitution of firm/concern. (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The plastering work after cutting of grooves shall be finished properly in the level of original wall with painting/white wash to the satisfaction of Railways.
The contractor has to submit drawing/plan showing route diagram to consignee for signature of concerned SSEs of other departments. It required geological survey to be conducted at his own cost to avoid damage of any other cable/Pipe etc.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderer/s shall be treated as Null & Void.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderer/s shall be treated as Null & Void.
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. tenderer shall submit GST certificate along with the offer.
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017.
IF ANY DISCREPANCY IS FOUND IN THE TENDER DOCUMENT, NAMELY SOR ITEM DESCRIPTION, SPECIAL TENDER CONDITION ETC., CLARIFICATION CAN BE SOUGHT FROM THE OFFICE OF SRDEE/G/DLI, DRM OFFICE, STATE ENTRY ROAD, NEW DELHI.
This tender complies with Railway Board instructions for Startups (recognized by Department of Industrial Policy and Promotion, Ministry of Commerce and Industry) for exemption from payment of Bid Security as detailed in GCC 2022 as amended from time to time. Such Startup firms may note that no other exemption is applicable to them in this particular tender.
On account payment, contractor shall submitted indemnity bond with validity up to the completion/extended period in the prescribed format (please refer Annexure-XXVIII) at the contractor's cost, vesting the ownership of such material with the railways.
Electrical work in connection with: i) Upgradation of Lobby/running room at DLI by providing various facilities to Running staffs. ii) Raising of platform no. 1 & 2 to high level at Vivek Vihar (VVB) station under ADEN/GZB.
51-SRDEE-G-DLI-2025-26~NR
51-SRDEE-G-DLI-2025-26
Open
Works - General
8 Months
Delhi, Delhi
₹0
₹1.2 L
7 Jan 2026
16 Dec 2025
24 Dec 2025
131 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 60,45,751.7 | ||
| — | 10.00 | — | — | ||
| Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core etc. as required. CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.10.1. & as per Explanatory Note. Group A | — | — | — | 7,080 | |
| — | 10.00 | — | — | ||
| Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core etc. as required. as per CPWD General Specifications for Electrical Works Part-I Internal - 2023 & CPWD DSR (E&M) 2022 Item no. 1.10.2.& as per Explanatory Note. Group B | — | — | — | 7,740 | |
| — | 310.00 | — | — | ||
| Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core etc. as required. as per CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.10.3. & as per Explanatory Note. Group C | — | — | — | 4,37,100 | |
| — | 700.00 | — | — | ||
| Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.14.2 and as per explanatory note. Size : 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire | — | — | — | 1,84,800 | |
| — | 500.00 | — | — | ||
| Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.14.3 & as per Explanatory Note. Size : 2 x 4 sq. mm + 1 x 4 sq. mm earth wire | — | — | — | 1,39,500 | |
| — | 300.00 | — | — | ||
| Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.14.4 & as per Explanatory Note. Size : 2 x 6 sq. mm + 1 x 6 sq. mm earth wire | — | — | — | 1,08,300 | |
| — | 130.00 | — | — | ||
| Supply of ceiling rose, 3 plate/3pin 5A conforming to IS : 371-1999 (or Latest Version) & installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 Item No. 1.33 . & as per Explanatory Note . | — | — | — | 9,100 | |
| — | 150.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6A modular switch, connections etc as required. as per IS, IE rule & site requirement of reputed make conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.31 & as per Explanatory Note. | — | — | — | 66,600 | |
| — | 70.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16 A modular socket outlet and 15/16A modular switch, connections etc as required. as per IS, IE rule & site requirement conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.32 & as per Explanatory Note. | — | — | — | 38,990 | |
| — | 50.00 | — | — | ||
| Supply of Batten/Angle Holder conforming to IS : 1258-2005 (or Latest Version) & installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 Item No. 1.34 . & as per Explanatory Note . | — | — | — | 6,050 | |
| — | 110.00 | — | — | ||
| Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connections, painting etc. as required. (For AC's and Geysers etc ) & as per Explanatory Note. | — | — | — | 74,250 | |
| — | 250.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaire, having system wattage 1x18 watt. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. The LED based 4 ft. tube light (lamp) shall be of make Phillips, Bajaj, Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per Explanatory Note. | — | — | — | 1,58,250 | |
| — | 50.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaire, having system wattage 2x18 watt. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. The LED based 4 ft. tube light (lamp) shall be of make Phillips, Bajaj, Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per Explanatory Note. | — | — | — | 54,400 | |
| — | 80.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED bedside lights, system wattage 6W, CRI>80,4000K/6000K, Housing made of aluminum/CRCA sheet with powder coated, mild steel neck, cool white with compatible inbuilt LED driver complete with prior approval of sample and shall be conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest, IS, IE rules and site requirement & as per Explanatory Note. | — | — | — | 47,920 | |
| — | 200.00 | — | — | ||
| Supply, fixing, testing and commissioning of 4-feet long surface mounting 36-Watt, 5700K,CRI>80, LED Luminaire as per CEE/NR's spec. No. CEE/NR/121 Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121 Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest, IS, IE rules and site requirement. Fitting shall be environmentally friendly, long life, corrosion resistant, impact proof IP 66 with PC housing & opal finish cover suitable for wet location similar to Make - Havells Model No. MAGNUM NEO or equivalent Fitting shall be suitable for operation on single phase 240Volt, 50 Hz AC supply & as per Explanatory Note. | — | — | — | 6,20,000 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED down lighter, housing aluminum die cast, white powder coated and PMMA diffuser having system wattage less than or equal to 15 Watt complete with all mounting arrangement, accessories complete confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per Explanatory Note. | — | — | — | 14,880 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaries 595x595 mm size, recessed mounting fitting (Tile type),as per IS : 10322 ( or latest) having system wattage less than or equal to 48 Watt, CRCA body powder coated, high efficiency milky white PMMA diffuser with no bright spot visible, complete with all mounting arrangement with suitable frame to avoid droping down of fitting of make Phillips, Bajaj,Havells or similar confirming to CEE/NR's spec. No. CEE/NR/121- Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per Explanatory Note. | — | — | — | 33,040 | |
| — | 85.00 | — | — | ||
| Supply, fixing, testing and commissioning of 45 watt LED based street light luminary with cool white light, pressure die cast aluminum housing, IP 65 or better having system complete confirming to CEE/NR's spec. No. CEE/NR/121- Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per Explanatory Note. | — | — | — | 2,52,264.7 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of 90W LED based street light luminary with cool white light, pressure die cast aluminum housing, IP 65 or latest complete confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per Explanatory Note. | — | — | — | 61,090 | |
| — | 100.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required as per IS 1255 and detail drawing approved by competent authority conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 Item No. 7.1.1 & as per Explanatory Note. Upto 35 sq. mm | — | — | — | 35,200 | |
| — | 400.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required as per IS 1255(latest version ) and detail drawing approved by competent authority conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 Item No. 7.1.2 & as per Explanatory Note. Above 35 sq. mm and up to 95 sq.mm | — | — | — | 1,68,400 | |
| — | 100.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required as per IS 1255 and detail drawing approved by competent authority conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 Item No. 7.1.2 & as per Explanatory Note. Above 185 sq. mm and up to 400 sq.mm | — | — | — | 50,700 | |
| — | 640.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface/cable tray as required conforming to IS 1255 (latest version ) and CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 Item No.7.7.1 Upto 35 sq. mm (clamped with 1mm thick saddle) & as per Explanatory Note. | — | — | — | 35,200 | |
| — | 100.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface/cable tray as required conforming to IS 1255 (latest version) and CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 Item No.7.7.2 Above 35 sq. mm and upto 95 sq.mm (clamped with 25x3mm MS flat clamp) & as per Explanatory Note. | — | — | — | 13,000 | |
| — | 200.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface/cable tray as required conforming to IS 1255 and CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 Item No.7.7.4 Above 185 sq. mm and upto 400 sq.mm (clamped with 25/40x3mm MS flat clamp) & as per Explanatory Note. | — | — | — | 45,200 | |
| — | 1760.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL/HDPE pipe as required conforming to IS 1255 (latest version) and CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 Item No. 7.5.2. Above 35 sq.mm and Upto 95 sq. mm & as per Explanatory Note. | — | — | — | 1,00,320 | |
| — | 100.00 | — | — | ||
| Supplying and installing following size of perforated Hot dipped Galvalinsed Iron cable trays (Galvanisation thickness not less than 50 micron) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI. suspenders including bolts & nuts, painting suspenders etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness & as per Explanatory Note. | — | — | — | 74,200 | |
| — | 1760.00 | — | — | ||
| Supplying & laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II & IS 16205 complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required and confirming to DSR 2022 S.No. 14.16.2 & as per Explanatory Note. 90 mm dia (OD-90 mm ID-76 mm nominal). | — | — | — | 5,10,400 | |
| — | 28.00 | — | — | ||
| Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia. class-B as per IS:3043 or latest version to achieve Earth resistance less than 5 ohm including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (appx size 400mm x 400mm on top), provision of Earth plate, connections from Earth electrode to switch gear/ pole as per drawing including accessories, having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required and as per explanatory note. | — | — | — | 1,61,028 | |
| — | 40.00 | — | — | ||
| Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) and as per explanatory note. | — | — | — | 5,760 | |
| — | 300.00 | — | — | ||
| Supply, fixing, testing and commissioning of size 25mm diameter PVC conduit of insulating materials of Heavy duty conforming to IS-9537/Part-3 (Latest version) including all accessories in recess / surface under the platform shed/truss as per IS, IE rules and site requirement. NOTE: - On ceiling / locations where provision of recess conduit is not possible then conduit will be provided on surface as per site condition and as per instruction by Rly. Representative and as per explanatory note. | — | — | — | 9,300 | |
| — | 400.00 | — | — | ||
| Supply, laying, fixing, testing and commissioning of 1x1.5 sq mm FRLS, PVC insulated multi stranded copper conductor single core cable 1100 Volts confirming to IS-694 (latest version), make Finolex, Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as per explanatory note attached, IS & IE rules. Note:- *Test certificate in original to be submitted. | — | — | — | 5,200 | |
| — | 1000.00 | — | — | ||
| Supply, laying, fixing, testing and commissioning of 1x2.5 sq mm FRLS, PVC insulated multi stranded copper conductor single core cable 1100 Volts confirming to IS-694 (latest version), make Finolex, Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as per explanatory note attached, IS & IE rules. Note:- *Test certificate in original to be submitted. | — | — | — | 18,000 | |
| — | 50.00 | — | — | ||
| Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 Item No. 5.16 and as per explanatory note . | — | — | — | 2,550 | |
| — | 50.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with brush less direct current ( BLDC) motor, class of insulation B,03 Nos blades, 30 CM long down rod,02 Nos conopies, shakle kit, safety rope, copper winding, Power factor not less than 0.9, service value (CM/M/W) minimum 6.00,Air delivery minimum 210 Cum/Min,350RPM (tolerence as per IS: 374-2019 or latest) THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C ( max) , insulation resistance more than 2 mega ohm, suitable for 230 V,50Hz,single phase AC supply, bearthing etc. complete as required. It shall also include the scope of supply and installation of safety cord of SS as per IS:302 Part 2 Sec-80. Dia & length of such cord shall be as per recommendation of OEM of fan and same shall be approved by railway; conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 Item No.19.1 & as per Explanatory Note. | — | — | — | 1,36,500 | |
| — | 11.00 | — | — | ||
| Supply, fixing, testing and commissioning of 380mm sweep, 1400 rpm (approx) propeller type exhaust fan complete in all respect as specification and as per site requirement, including grouting of nut, bolts, washer and with the suitable fasteners conforming to IS:2312:1967 (or latest version) . Make Bajaj, Usha, Havells, Orient or equivalent & as per Explanatory Note. | — | — | — | 34,639 | |
| — | 30.00 | — | — | ||
| Provision of energy efficient 230V, 50Hz a.c ceiling fan with BLDC motor of size 1400mm sweep having wattage of 35W, 5 star, speed regulator operation: Using Remote Control, 36 months warranty complete as per IS :374:2019 latest, IE & site requirement.It shall also include the scope of supply and installation of safety cord of SS as per IS:302 Part 2 Sec-80. Dia & length of such cord shall be as per recommendation of OEM of fan and same shall be approved by railway.& as per explanatory note. | — | — | — | 72,750 | |
| — | 80.00 | — | — | ||
| Supply & erection of hot dip galvanized octagonal pole 5 Mtrs. long Single Arms, confirming to IS 2629/BSEN ISO 1461 latest version with top 70 mm and bottom 130 mm around face made of 3 mm thick,steel base plate size 200 x200x12 mm complete with appropriate sleeve at the top of the pole for mounting arm bracket 300 mm long ( or as per site requirement ) suitable for LED street light fittings including casting,muffing with cement concrete foundation (1:2:4) painting, earthing and foundation GI nut,bolts with washer and smart pack junction box with 1A single pole MCB and terminals. Pole junction box shall be sealed with water proof tape and display of danger sticker. Note- Wiring in between pole junction box to fitting shall be done through 3 cores 1.5 sq. mm double insulated weather proof cables & as per Explanatory Note. | — | — | — | 7,41,600 | |
| — | 5.00 | — | — | ||
| Supply & erection of hot dip galvanized octagonal pole 5 Mtrs. long Double Arms, confirming to IS 2629/BSEN ISO 1461 latest version with top 70 mm and bottom 130 mm around face made of 3 mm thick,steel base plate size 200 x200x12 mm complete with appropriate sleeve at the top of the pole for mounting arm bracket 300 mm long ( or as per site requirement ) suitable for LED street light fittings including casting,muffing with cement concrete foundation (1:2:4) painting, earthing and foundation GI nut,bolts eith washer and smart pack junction box with 1A single pole MCB and terminals. Pole junction box shall be sealed with water proof tape and display of danger sticker. Note- Wiring in between pole junction box to fitting shall be done through 3 cores 1.5 sq. mm double insulated weather proof cables & as per Explanatory Note. | — | — | — | 56,270 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing and commissioning of (RCBO Incoming & SP/MCB-Outgoing) wall mounted double door type distribution board made up of CRCA sheet, phosphatised powder painted, anti-corrosion treatment complete with neutral link, earth point, Din rail and prewired confirming to IS: 13032 & IS/IEC 61439-2 : 2011(or latest) of make Havells, Siemens, L&T, Schneider, Legrand or equivalent with following items of matching make to be fixed in distribution board, confirming to IS/IEC 60898 or latest, IE rules and site requirement. DP RCBO 30/100/300 mA 63 Amps. = 01 No. (Incoming) SP MCB 6-32 Amps. 'C' series = 09 Nos. (Outgoing) It should have proper cable entry points with glands and should be rodent entry proof. & as per explanatory note. | — | — | — | 32,795 | |
| — | 100.00 | — | — | ||
| Supply Laying, testing and commissioning of HDPE pipe of 160 mm dia having material grade PE- 100, wall thickness PN-6 and confirming to IS-4984 or latest as per IE rules and site requirement for cable laying through HDPE pipe of 160mm diameter by trench less method as per IS -1255 or latest & IE rules and site requirement & as per explanatory note. | — | — | — | 1,07,500 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing and commissioning of 25/32 A,30 mA RCCB AC type confirming to IS-12640-1 & IEC61008-1 with 10KA short circuit withstand capacity complete with enclosure for water cooler etc. & as per explanatory note. | — | — | — | 13,450 | |
| — | 1.00 | — | — | ||
| Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 Item No.2.2.15.& as per explanatory note. 200 A, 36 KA, 4 Pole MCCB | — | — | — | 15,206 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of LT distribution board recessed mounting double door type made up of CRCA sheet sheet with anti corrosion treatment and suitable, IP 54 phosphatised powder painted complete with neutral link, earth point, Din rail and prewired confirming to IS:13032 & IS/IEC:61439 of make ABB, Havells, Siemens, L&T, Schneider, Legrand, C&S or equivalent with following items of matching make to be fixed in distribution board, confirming to IS/IEC:60898-1 :2002 or latest, IE rules and site requirement. It should be rodent entry proof. It should also include well dressing and coding of circuit. 63A 4P RCBO 100 mA= 01 No. (Incoming) 6- 32A MCB SP """"C"""" Series =18 Nos. (Outgoing)"" & as per Explanatory Note. | — | — | — | 52,828 | |
| — | 1.00 | — | — | ||
| Design, Supply, fixing, testing and commissioning of front operated double door outdoor type weather proof feeder pillar body made of CRCA sheet sheet with anti corrosion treatment and suitable having IP 65 protection (MCCB - Incoming & MCCB - Outgoing) comprising with the following MCCB's fixed in it of make: Havells, Siemens, L&T, Schneider, Legrand or equivalent conforming to IEC 60947-2 & IS/IEC:61439 or latest with digital measuring instrument & bus-bar arrangement confirming to PCEE/NR's spec. No. PCEE/NR/126-Elect/PS/2019 at Tech Spec-III attached or latest and as per IS, IE rules and site requirement. It should be dust & vermin proof and powder coating as per IS 13871-2021 (or latest version). a) 4P MCCB 400Amps 36 kA with adjustable thermal & fixed magnetic release =01 Nos. (Incoming). b) 4P 400 Amps on load change over switch (COS)=01 No. c) 4P MCCB 250Amps 36 kA with adjustable thermal & fixed magnetic release =04 Nos. (Outgoing). d) 4P MCCB 125Amps 36 kA with adjustable thermal & fixed magnetic release =04Nos. (Outgoing)."" & as per Explanatory Note. | — | — | — | 4,17,641 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of 63 A, 30 mA DP RCCB AC type confirming to IS:12640-1:2024 & IEC 61008-1 with 10KA short circuit with stand capacity complete with enclosure for water cooler. conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 Item No. 2.15.3 & as per Explanatory Note. | — | — | — | 5,444 | |
| — | 3.00 | — | — | ||
| Indoor VRV Units (Nominal Capacity) - Ceiling Mounted Round/4way flow cassette type Unit" Design, Supply, Installation, testing & commissioning of ceiling mounted cassette type unit. These units shall be installed between the bottom of finished slab &top of false ceiling. The unit must have in built drain pump, suitable for vertical lift up to 750 mm. The noise level of unit at the highest operating level shall not exceed 50dB (A), at a vertical distance of 1.5 m from the grille of the unit. Unit shall have provision of connecting fresh air. The unit shall be supplied with prefilters, fan section and DX-coil section. The filter shall be easy to remove,clean & re install. The bodyshall be light in weight and shall be able to suspend from four corners. Unit shall have an external attractive panel for supply and return air. Each unit shall have high lift drain pump, andLow gas detection system.The fan shall be aerodynamically designed diffuser turbo fan type. All 4 louvers of the unit shall be independently adjustable forposition as per user preference. All indoor Units should have force shutoption to connect with firealarm adaptor, so that theunit can be integrated withother systems to stop automatically such as incase of fire and confirming to specification at tech spec IV ; 2.0 TR/ 671 CFM | — | — | — | 1,33,935 | |
| — | 1.00 | — | — | ||
| Outdoor Unit" "Variable Refrigerant flow system" Supply, Installation, testing and commissioning of modular type variable refrigerant flow air conditioning system suitable for both heating and cooling with Inverter Scroll Compressor suitable for 415±10% V for outdoor unit including fully charged with refrigerant R410A suitable to operate at -5° to 52 C ambient temperature to outdoor unit and all running refrigerant pipe. It shall include anti vibration isolator pad for outdoors unit. The unit shall be complete in all respect asper site requirement. The unit shall have auto phase corrector so that unit can work in case of phase reversal and accumulator should be present in outdoor units to prevent liquid backflow in compressor ; and confirming to specification at tech spec IV. 16HP VRFOUTDOOR UNIT (Cooling & Heating) | — | — | — | 3,47,116 | |
| — | 3.00 | — | — | ||
| Supply, installation & testing of cordless remote with receiver for the above indoor & cassette type units and confirming to specification at Tech Spec-IV. | — | — | — | 3,753 | |
| — | 20.00 | — | — | ||
| Refrigerant Piping for VRF system"" Supply & Installation of inter connecting suitable sizes of one end expanded refrigerant copper pipework, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor &outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray asmentioned below for exposed pipes and in the shaft and confirming to specification at Tech Spec-IV. 28.6 mm dia with 19mm thick nitrile rubber insulation: 16G" | — | — | — | 47,160 | |
| — | 20.00 | — | — | ||
| Refrigerant Piping for VRF system"" Supply &Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipework, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor &outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification at Tech Spec-IV. 22.2 mm dia with 19mm thick nitrile rubber insulation: 16G | — | — | — | 36,800 | |
| — | 10.00 | — | — | ||
| Refrigerant Piping for VRF system"" Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipework, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe sizeabove 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor & outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification at Tech Spec-IV. 19.1 mm dia with 13mm thicknitrile rubber insulation: 18G" | — | — | — | 12,190 | |
| — | 30.00 | — | — | ||
| Refrigerant Piping for VRF system :Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipework, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe sizeabove 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor & outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification at Tech Spec-IV. 15.9 mm dia with 13mm thicknitrile rubber insulation: 18G | — | — | — | 31,020 | |
| — | 20.00 | — | — | ||
| "Refrigerant Piping for VRF system" Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipework, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe sizeabove 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor & outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification at Tech Spec-IV. 12.7 mm dia with 13mm thicknitrile rubber insulation: 18G" | — | — | — | 16,480 | |
| — | 30.00 | — | — | ||
| "Refrigerant Piping for VRF system"" Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipework, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe sizeabove 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor & outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification at Tech Spec-IV. 9.5 mm dia with 13mm thicknitrile rubber insulation: 18G" | — | — | — | 19,140 | |
| — | 20.00 | — | — | ||
| Supply ,Installation, testing and commissioning of uPVC pipe, complete with fittings, supports ,U trap arrangement ,Clean Plug and accessories for AHU/IDU as per site requirement . 32 mm dia ( with 9 mm Nitrile) .confirming to specification at Tech Spec-IV | — | — | — | 4,240 | |
| — | 20.00 | — | — | ||
| Supply, Fixing, Testing and Commissioning of UPVc drain pipe,size 25 mm dia complete with all,accesories. Preferred Make:-AKG, Rajgold, Supreme, Finolex or,equivalent Reputed brand and of relevant IS. & confirming to specification at Tech Spec-IV . | — | — | — | 3,120 | |
| — | 3.00 | — | — | ||
| Supply, Installation, testing and commissioning of T-joints and header etc. and confirming to specification at tech spec IV. | — | — | — | 15,972 | |
| — | 20.00 | — | — | ||
| Supply,laying,testing and commissioning of communication cable (1.5 Sq mm x 2 core) and confirming to specification at tech spec IV | — | — | — | 3,560 | |
| — | 1.00 | — | — | ||
| Supply,Installation,testing and commissioning of MS fabricated outdoor unit stand for placing outdoor unit of VRVsystem.The stand shall be manufactured from MS C Channel of minimum 3-4 mm thick. It shall be finished with enamel paint as per client/architect approval .& confirming to specification at Tech Spec-IV . | — | — | — | 3,410 | |
| — | 20.00 | — | — | ||
| Supply of Refrigerant (R410a/32) charge to the outdoor unit and connected pipes between outdoor unit and indoor unit as per site requirement.& confirming to specification at Tech Spec-IV . | — | — | — | 19,700 | |
| — | 30.00 | — | — | ||
| Supply,fixing,testing and commissioning of suitable size interconnecting control cable size (5Cx6.0 sq mm) from indoor to outdoor unit complete with suitable size copper earthing as per relevant IS & IE rules and site requirement . & confirming to specification at Tech Spec-IV . | — | — | — | 10,470 | |
| — | 20.00 | — | — | ||
| Supply of PVC insulated flexible Copper cable 3C x 2.5 sq mm complete as per latest IS and IE rules.& confirming to specification at Tech Spec-IV . | — | — | — | 2,000 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of 150 liter/Hrs water cooler Storage type self contained drinking water cooler, operation on 230V AC 50 Hz (Non CFC refrigerant), cooling cap(in L/hr)-150, storage Cap (in Lts) 150; Max Energy Consumption -1550 W, PowerFactor= or more than 0.85, Tanksheet material-Strainless steel (Grade A-IS304), Thickness of sheet (in mm) 0.8. equal to or more than, Water Tank cover material -Strainless steel (Grade A-IS304) thickness 0.8 and lid bottomsheet material and thickness-Alluminium sheet material & thickness-Aluminium sheet 1.5 (in mm),operatingvoltage 230 V ac single phase 50Hz, Confirming to IS-1475 or iatest, ISI marked, warranty on site as per IRS terms & conditions or OEM whichever is maximum, warranty on compress or as per IRS terms & Condition or OEM whichever is higher, Make:-Sidwal, Bluestar or equivalent.& as per explanatory note. | — | — | — | 49,250 | |
| — | 4.00 | — | — | ||
| Supply installation, testing & commissioning of 25 Itrs stationary storage type electric water heater (Geyser) having BEE starrating- 5 star, Installation vertical, ABS Body, element wattage-2kW,Tank capacity -25 ltrs, conforming to IS. 2082/1993 with latest amendment complete and as per site requirement .& as per explanatory note. | — | — | — | 44,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022-ACS10_merged.pdf
ATTACHMENT
SpecialConditionofContractof51-SRDEE-G-DLI-2025-26.pdf
ATTACHMENT
TECHSPEC-I_1.pdf
ATTACHMENT
TECHSPEC-II_1.pdf
ATTACHMENT
TECHSPEC-III.pdf
ATTACHMENT
TechSpec-IV.pdf
ATTACHMENT
TenderDocument51-SRDEE-G-DLI-2025-26_2.pdf
ATTACHMENT
updatedexplanatorynote_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .