| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC HARIPUSHPA APARTMENT BUILDING NO E 1 FLAT NO 01 REST CAMP ROAD DEOLALI CAMP 422 401 | DEOLALI CAMP | NASHIK | MAHARASHTRA | 422401 | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹19.3 L+₹75,680 (4.09%)Rejected-Finance | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹19.5 L+₹98,270 (5.31%)Rejected-Finance R 7 10 RAJ NAGAR GHAZIABAD GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder |
Tender Value
₹29.9 L
EMD Value
₹59,900
Closing Date
17 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR-03 OF 2020-21 REPAIR / MAINTENANCE TO UNDERGROUND OVER HEAD HT / LT EXTERNAL ELECTRIFICATIONSYSTEM ALONGWITH OTHER CONNECTED ITEMS AT MILITARY STATION FAZILKA (2ND CALL)
2020_MES_340117_2
CA NO. CWE SGNR - 03 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
ABOHAR
Class D
Category b(ii)
10 documents required · 10 mandatory
₹500
GE ABOHAR
₹59,900
Yes
14 Aug 2020
26 Jun 2020
21 Jul 2020
26 Jun 2020
17 Jul 2020
3 Jul 2020
60 days
Amount
Taking down defective LED street light or Flood light or High mask light of capacity any capacity 25W/30W/60/W/90W/120W/200W, fitting of any type from their existing position i.e. poles and bldg and re-fixing the same after carried out repairs of LED driver,SPD , PVC wire and any other necessary connecting item and making suitable for lightning purpose, complete all as specified and directed by Engineer-in-Charge. Note : (i) LED driver, and SPD , 3 core cable will be measured and paid separately under respective items of BOQ. (ii) Cost of nut, bolts & washers for fixing new items is included in the unit rate of item
Supply only surge protection device (SPD) of capacity 10 KV with phase, neutral and earth wire in incoming and out going both sides complete all as specified and directed by Engineer-in-Charge.
Supply only surge protection device (SPD) of capacity 8 KV with phase, neutral and earth wire in incoming and out going both sides complete all as specified and directed by Engineer-in-Charge.
Supply only surge protection device (SPD) of capacity 5 KV with phase, neutral and earth wire in incoming and out going both sides complete all as specified and directed by Engineer-in-Charge.
Supply only LED driver 25 W LED Street light fitting complete all as specified and directed by Engineer-in-Charge.
Supply only LED driver 30 W LED Street light fitting complete all as specified and directed by Engineer-in-Charge.
Supply only LED driver 60 W LED Street light fitting complete all as specified and directed by Engineer-in-Charge.
Supply only LED driver 90 W LED Street light fitting complete all as specified and directed by Engineer-in-Charge.
Supply only LED driver 120 W LED Street light fitting complete all as specified and directed by Engineer-in-Charge.
Supply only LED driver 200 W LED Street light fitting complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of LED street light fitting of 25 Watt IP 66 aluminium housing in grey finish with clear acrylic and cast aluminium pipe mounting attachment including external SPD of capacity 5 KV complete all as specified and directed by Engineer-in-Charge. MAKE : BAJAJ/SYSKA Cat Part No.SSK-ST-25W-1 or equivalent to HAVELLS/PHILIPS
S&F in repairs of LED street light fitting of 60 Watt IP 66 aluminium housing in grey finish with clear acrylic and cast aluminium pipe mounting attachment including external SPD of capacity 5 KV complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of LED street light fitting of 120 Watt IP 66 aluminium housing in grey finish with clear acrylic and cast aluminium pipe mounting attachment including external SPD of capacity 8 KV complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of LED street light fitting of 200 Watt IP 66 aluminium housing in grey finish with clear acrylic and cast aluminium pipe mounting attachment including external SPD of capacity 10 KV complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Hot moulded (FRP) junction box of size 280mm x 200mm for street light pole with locking arrangement with 32 Amps, 4 way heavy duty terminal block suitable connection for three phase incoming cable three phase outgoing cable and single phase connection for light fittings with control MCB SP 10 Amps 01 Nos enclosed in thermoplastic box in closed shock proof safe IP 65, weather, vermin proof, dust and water proof complete with two number cable entry gland of standard size with suitable size mild steel clamps to fix on pole complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 1.5 sqmm 3 core, 1100 volts grade heavy duty cable, PVC insulated copper multistranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed for making connections of street light from FRP junction box to street light complete all as specified and directed by Engineer-in-Charge.
S&F in repairs pre stressed cement concrete poles 11 mtrs long or cross section (152mm x 152mm) at top and (152mmx 260mm) at bottom class-9 complying with requirement of IS-1678, 1978 including making 30 CM strip with two coats of white and black synthetic enamel paint up to 1.5 Mtrs height complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earthwork and PCC shall be measured and paid separately under respective item of BOQ
S&F in repairs cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size as indicated or directed complete all as specified and directed by Engineer-in-Charge. Note :Exposed steel surface shall be treated with two coats of aluminium paint over a coat of red oxide primer and unexposed surface of steel sections shall be applied one coat of red oxide primer.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge.
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for 100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor complete all as specified and directed by Engineer-in-Charge.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation for poles, stays & mass concrete complete all as specified and directed by Engineer-in-charge
Taking out old unserviceable underground LT Cable of 4/3.5 core, 10 Sqmm to 70 Sqmm form trenches/floor/road/pipe/along poles including taking out old bricks complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth work required for item shall be measured and paid separately under respective items of BOQ.
Supplying, laying, jointing and testing and commissioning 6 sqmm, 4 core XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ.
All as per Srl item No 30 here-in-before but cable of cross sectional area 10 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 30 here-in-before but cable of cross sectional area 16 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 30 here-in-before but cable of cross sectional area 25 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 30 here-in-before but cable of cross sectional area 35 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 30 here-in-before but cable of cross sectional area 70 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, jointing and testing heat shrinkable type straight through cable jointing kit, suitable for 11000 Volts under ground XLPE armoured aluminium conductor cable of size 95 Sqmm, 3 core including making connections complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 36 here-in-before but suitable for cable size 120 to 185 Sqmm, 3 core complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, jointing and testing of cable jointing kit, end terminal, outdoor termination Heat shrinkable type, suitable for 11KV under ground earthed system 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 38 here-in-before but suitable for cable size 120 Sqmm, 3 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 38 here-in-before but suitable for cable size 150/185 Sqmm, 3 core complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, laying, jointing testing and commissioning in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11000 Volt grade of cross-sectional area 95 Sqmm, 3 core, IS 7098 marked, suitable for HT 11000 Volt (E) system , laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed by Engineer-in-Charge.
Disconnecting of LT supply and opening bus bar chamber / cable box chamber of outdoor / indoor LT Panel, removing of burnt out lugs, MCCB/ MCB of any capacity and size and cleaning of bus bar with CTC solutions, insulating the bus bar by taping with RYB colours, necessary nut bolts of existing size and refixing after repairs complete all as specified and directed by Engineer-in-Charge. Note : (i) Aluminium lugs of any size as per site shall be measured and paid for separately. (ii) MCCB/MCB of any capacity shall be measured and paid for separately.
Supply only aluminium lugs suitable for cable of size 6 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 10 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 16 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 25 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 35 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 50 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 70 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 95 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 120 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 150 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing for MCCB 4 pole 63 A , 415 V, 50Hz having breaking capacity 16KA with all fitting accessories complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing for MCCB 4 pole 100 A , 415 V, 50Hz having breaking capacity 16KA with all fitting accessories complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing for MCCB 4 pole 125 A , 415 V, 50Hz having breaking capacity 16KA with all fitting accessories complete all as specified and directed by Engineer-in-Charge.
Supply only MCCB 3 pole 160 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as specified and directed by Engineer-in-Charge.
Supply only MCCB 3 pole 200 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as specified and directed by Engineer-in-Charge.
Supply only MCCB 3 pole 250 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as specified and directed by Engineer-in-Charge.
S&F in repairs HT 11KV outdoor type gang operaled air break switch suitable for horizontal or vertical mounting fixed type mechanically operated amounted on insulator and steel frame out door type for vertical installation single break provided with locking arrangement top of MS channel HT post insulator 11 KV consisting of operating rod of 25mm dia GI pipe medium grade conforming to IS-1818 of 1972 complete with 12 insulators and of rating 200 amps. complete all as specified and directed by Engineer-in-Charge.
Dehydration and filtration of existing transformer oil for transformer of any capacity using centrifugal plant to eliminate foreign particles and to improve di-electric strength not less than 40 KV for 1 minute in 2.5mm electrode gap as per relevant IS and to bring the acidity within the permissible limit complete all as specified and directed by Engineer-in-Charge. Note :- Transformer oil required for topping up shall be measured and paid for separately under respective item of BOQ.
Disconnecting HT & LT side cables of indoor/ outdoor transformer of capacity 100KVA to 400KVA and earth strip from body and neutral of transformer mounted on two pole/four pole structure/staging and taking down the transformer manually/using mechanical means and lifting, loading and transportation of transformer from MES store yard/sub station/site to workshop for repairs and opening of covers, draining out existing transformer oil, lifting of core, cleaning of oil tank, using chemicals, cleaning of core after removing HT/LT windings, re-assembling of new HT/LT windings with core varnishing heating and bringing back the same after repairs to the same point complete all as specified and directed by Engineer-in-Charge. Note : (i) Rewinding of HT/LT coil any type/material, dehydration of transformer oil re-assembling after repair etc will be measured and paid separately under relevant items of this schedule (ii) Spare parts shall be measured and paid separetely as supply only and cost of fixing and connecting of the spares shall be deemed to be included in the quoted rate of the above items.
Un-winding old/defective coil, removing insulation complete by brushing coil, cleaning and making free from dirt and all impurities, applying paper insulation (IS Specified), Rewinding of HV/LV coil (Copper Metal) of transformer capacity 200 KVA to 400 KVA complete all as specified and directed by Engineer-in-Charge.
Rewinding of HT coils with super enameled best quality copper wire of existing gauge with superior quality insulation material for transformer capacity 200 KVA to 400 KVA complete all as specified and directed by Engineer-in-Charge.
Rewinding of LT coils with super enameled best quality copper wire of existing gauge with super quality insulation material for transformer capacity 200 KVA to 400 KVA complete all as specified and directed by Engineer-in-Charge.
Assembling of HV and LV coils including necessary insulation with paper boards and varnishing, making internal connections, drying, removal of moisture from core and coils, heating the complete necessary and carrying out all necessary tests for transformer capacity 100 KVA to 400 KVA complete all as specified and directed by Engineer-in-Charge.
S&F in repairs improvement of insulation resistance value for core & coil winding by cleaning complete, applying varnishing & necessary insulation material and baking in oven terminal connection inside the transformer complete all as specified and directed by Engineer-in-Charge.
S&F in repairs ceramic HV bushing with gun metal bushing stud, nuts, bolts and washers for transformers of 100 KVA to 250 KVA capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repairs ceramic HV bushing with gun metal bushing stud, nuts, bolts and washers for transformers of 315 KVA to 400 KVA complete all as specified and directed by Engineer-in-Charge.
S&F in repairs ceramic LV bushing complete with bushing stud (Brass Metal ) nuts, bolts and washers for transformers capacities 100 KVA to 250 KVA complete all as specified and directed by Engineer-in-Charge.
S&F in repairs ceramic LV bushing complete with bushing stud (Brass Metal) nuts, bolts and washers for transformer of 315 KVA to 400 KVA capacity complete all as specified and directed by Engineer-in-Charge.
S & F in repairs HV tapped switch suitable for transformer of capacity 100 KVA to 250 KVA incl internal electric connection complete all as specified and directed by Engineer-in-Charge.
Supply & filling for fresh transformer oil confirming to IS 335 having die electric strength upto 50 KV with oil testing kit 2mm thick top up transformer installed at different locations complete all as specified and directed by Engineer-in-Charge.
S & F for un-reinforced precast concrete cable cover class HV type-I with peak, size 300mm x180mm x 40mm laid flat length of cover across the length of cable complete all as specified and directed by Engineer-in-Charge.
S & F in repairs GI pipe 40mm bore dia light grade for protection of cable incl provision of clamps, nuts, bolts etc required for fixing of pipe along pole/ wall/laid under the reoad/trenches/floor complete all as specified and directed by Engineer-in-Charge.
S & F in repairs GI pipe 50mm bore dia light grade for protection of cable incl provision of clamps, nuts, bolts etc required for fixing of pipe along pole/ wall/laid under the reoad/trenches/floor complete all as specified and directed by Engineer-in-Charge.
S & F in repairs GI pipe 80mm bore dia light grade for protection of cable incl provision of clamps, nuts, bolts etc required for fixing of pipe along pole/ wall/laid under the reoad/trenches/floor complete all as specified and directed by Engineer-in-Charge.
S & F in repairs GI pipe 32mm bore dia light grade for protection of cable incl provision of clamps, nuts, bolts etc required for fixing of pipe along pole/ wall/laid under the reoad/trenches/floor complete all as specified and directed by Engineer-in-Charge.
M&L in repairs Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earth wire of size 4mm dia (8SWG) thick fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia upto 3m height above ground level and watering pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI wire/strip connecting upto pump,Gen set,LT panel and DBs earth connection is included in this item. (iii) GI pipe 15 mm dia protection pipe shall be provided upto Ground level.
M&L in repairs Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earht strip 32x6mm thick fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and watering pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip connecting upto pump,Gen set,LT panel and DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level. -------------------------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,46,410.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 28 (Schedule of Credit) of Tender document
HARSH CONSTRUCTION CO.
Eagle Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .