Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC 00 PANCHARIYA NEAR SANTOSHI MATA TEMPLE MAHARASHI GOUTAM MARG NEW LINE GANGASHAHAR BIKANER BIKANER BIKANER RAJASTHAN 334401 | BIKANER | RAJASTHAN | 334401 | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹6.9 L+₹47,170.56 (7.32%)Rejected-Finance SHOP NO 02 GROUND FLOOR SAMUDRIKA CHS PLOT NO 183 URAN RAIGAD MAHARASHTRA 400 702 | RAIGAD | MAHARASHTRA | 400702 | L2 | Rejected-Finance Being other than L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to ban in WLR |
Tender Value
₹8.7 L
EMD Value
₹17,500
Closing Date
27 Jul 2022, 6:00 pmClosed
AGE (I) Naya Raipur
AGE (I) Naya Raipur C/o HQ COSA, Near International Cricket Stadium, Atal Nagar Raipur 492101
As per BOQ
2022_MES_525470_2
8400/323/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Naya Raipur
As per tender documents
8 documents required · 8 mandatory
₹500
AGE (I) Naya Raipur
₹17,500
1 Sept 2022
23 Jun 2022
29 Jul 2022
23 Jun 2022
27 Jul 2022
7 Jul 2022
Amount
Taking down carefully any type point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing ( Except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as directed by Engr-in-charge.
Taking down submain wiring any type and making good the disturbed sufaces to match with the existing surfaces complete all as specified
Taking out MCB DBs alongwith MCBs SP/SPN/TP/TPN any type and making good the disturbed sufaces to match with the existing surfaces complete all as specified.
M & L for Point wiring complete with ISI marked 1.5 Sqmm single core, FRLS Grade, PVC insulated unsheathed cable 1100 Volts grade with multistranded copper conductor drawn through in and including medium grade PVC conduit and accessories concealed in wall/roof/ceiling surface etc suitable for terminal boxes for fixing modular switches, sockets etc including suitable size modular plates concealed in walls and 1.5 Sqmm copper conductor as earth continuity to connect common earth dolly complete for One light point controlled by one 5 Amps one way switch complete all as specified. Make of Cable :- Havells / Polycab / Anchor and Make of PVC conduit & conduit accessories - PLAZA / FINOLEX/ KALINGA. Note :- (i) Making good to match with the adjoining surface shall be included in the quoted rate. (ii) Rate shall be included for Cutting/chases of wall/floor/ceiling
Ditto all as per item No 4 here in before but for One ceiling fan /exhaust fan point controlled by one 5 Amps one way switch
Ditto all as per item No 4 here in before but for One light point controlled by two 2-way switches 5 Amps
Ditto all as per item No 4 here in before but for One Bell light point controlled by one bell push 5 Amps
One three pins 5 Amps switch socket outlet point on independent board
Ditto all as per item No 4 here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches
Description all as per item No 4 here in before but for 16 amps socket outlet with 4 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
S & F Modular switch 1 way 6 Amps, 1 module complete all as specified Make - Legrand/ Crab tree / Philips/Anchor.
S & F Modular switch 2 way 6 Amps, 1 module complete all as specified Make - Legrand/ Crab tree / Philips/Anchor.
S & F Modular Bell push 6 Amps, 1 module complete all as specified Make - Legrand/ Crab tree / Philips/Anchor.
S & F Modular socket outlet 1 way 6 Amps 2/3 pins combined, 2 module complete all as specified Make - Legrand/ Crab tree / Philips/Anchor.
S & F Modular switch 1 way 16 Amps, 1 module complete all as specified Make - Legrand/ Crab tree / Philips/Anchor
S & F Modular socket outlet 1 way 6/16 Amps - 2/3 pins combined, 2 module complete all as specified Make - Legrand/ Crab tree / Philips/Anchor
S & F Call bell ding dong 230 volt AC single phase complete all as specified Make - Legrand/ Crab tree / Philips/Anchor.
S & F modular cover plate any type of 1 module complete all as specified Make - Legrand/ Crab tree / Philips/Anchor.
S & F modular cover plate any type of 2 module complete all as specified Make - Legrand/ Crab tree / Philips/Anchor.
S & F modular cover plate any type of 3 module complete all as specified Make - Legrand/ Crab tree / Philips/Anchor.
S & F modular cover plate any type of 4 module complete all as specified Make - Legrand/ Crab tree / Philips/Anchor.
S & F modular cover plate any type of 8 module complete all as specified Make - Legrand/ Crab tree / Philips/Anchor.
S & F modular type polycarbonate ceiling rose 63.50 mm dia , three terminals complete all as specified of Make - Legrand/ Crab tree / Philips/Anchor
S & F modular fan regulator, 120 watts, ISI marked, 2 module, step type complete all as specified
S&F Switch piano flush type polycarbonate , Single pole, one way, 6 amps, 230 Volts, complete all as specified
S&F socket outlet 2in 1, 5 pin , Single pole,polycarbonet one way, 6 amps, 230 Volts, complete all as specified
S&F Switch socket outlet 2 in 1, 5 pin combination polycarbonet, Single pole, one way, 16 amps, 230 Volts, complete all as specified
S&F independent board 5 pin Switch Socket combination 6 Amps complete all as specified
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified
Supply anf fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for retrofit/thread E-27 type bulbs complete all as specified and directed.
S & F of LED bulb 12W retrofit type complete all as specified Make ;-Wipro/Phillips/Bajaj/Havells/Crompton
Supply and fixing Wall mounting indoor decorativeLED T-8 batten with opel diffuser 1x 18 W LED tub light mounting over two nos of round wooden blocks complete with , tube and all accessories making electrical connections with twin core PVC flexible copper wire of size 0.50 sqmm upto 1.5 mtr length complete. Make Wipro/Phillips/Bajaj/Havells/Crompton
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make Wipro/Phillips/Bajaj/Havells/Crompton
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. Make Wipro/Phillips/Bajaj/Havells/Crompton
Supply and fixing round/Square shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. Make Wipro/Phillips/Bajaj/Havells/Crompton
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make Wipro/Phillips/Bajaj/Havells/Crompton
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make Wipro/Phillips/Bajaj/Havells/Crompton
S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar Triple pole and neutral 415 V, 4 Ways, double door type,complete all as specifide and directed.
S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 8 Ways, double door type complete all as specifide and directed.
S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 12 Ways, double door type, including taking down of existing sheet metal enclosure complete all as specifide and directed.
S & F MCB SPN 40 to 63 Amps, 240 Volts, minimum 10 KA, "C" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed :-(Make- Legrand / L&T / Havells) (Note for item No 36 to 38 :- Proper and suitable size cablecopper lugs to be fixed with MCBs are included in unit rate of each MCB of any rating)
S & F MCB SP 5 to 32 Amps, 240 Volts, minimum 10 KA, "C" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed :-(Make- Legrand / L&T / Havells)
S & F MCB TPN 40 to 100 Amps, 240 Volts, minimum 10 KA, "C" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed :-(Make- Legrand / L&T / Havells)
Supply and fix sheet metal enclosure earth plug socket for SP 20 amps , with single pole MCB 240 volts complete all as specified
M&L for submain wiring comprising single core, 2 Runs of 6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia PVC conduits and conduit fittings complete including S&F ,1 X 4 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire .
M&L for Rewinding of ceiling fans 1200mm sweep including opening of fan, Removing the burnt copper winding of ceiling fan after testing and cutting the rotor coil complete and making clean the rotor & the stator and rewinding with and including super enamelled copper wire of approved quality of existing gauge, over-hauling, lubricating with fresh grease including assembling with replacement of unserviceable parts (to be measured & paid seperately) and testing for satisfatory operation complete.
All as per item No 41 above but ceiling fans 1400mm sweep
M & L for Earthing complete with galvanised steel earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground (earth pit not less than 2.25 metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth wire 4 mm dia by means of GI bolts, nuts, check nuts and washers and earth strip protected by 25 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion.Notes: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II and also refer Plate No-03 incl dismantling of old existing complete all as specified. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately. Note :- Earthing will be redone if desied erath result not found during testing of the same at site.
M & L for Opening of ceiling fan 1200mm sweep of any make for over-hauling complete including providing fresh clean lubricating Oil/ grease, reassembling for proper functioning , with replacement of unserviceable parts (to be measured & paid seperately as supply only item and fixing cost shall be include in quoted rates) and testing for satisfatory operation complete.
All as per item No 44 above but ceiling fans 1400mm sweep
Supply only of ball bearing of 6201/120 for ceiling fan/ exhaust fan of any size and make complete. Make: NBC, SKF, TATA
All as per Item No 46 above but 6202/115 complete.
All as per Item No 46 above but 6203/117 complete.
All as per Item No 46 above but 6204/118 complete.
Supply only of condenser 2.5 MFD of apporved make for ceiling fan complete. Make : ED cos, Scimanse, Unic
Supply only of condenser 3.5/ 4 MFD of apporved make for echaust fan complete. Make : ED cos, Scimanse, Unic
Supply only of self lubricating bush of gun metal of same make for ceiling fan/exhaust fan complete.
Supply only of shaft of approved quality for ceiling fan/Exhaust fan any make and type & size complete.
Supply only of split pin suitable for ceiling fan/ exhaust fan any make and type & size complete.
Supply only rubber reel suitable for ceiling fan of any make and size.
Supply only GI pipe light grade with all fitting and fixed complete for ceiling fan as down rod .75 cm long of 15 mm bore.
M&L in replacement for clamps and back plates fabricated from steel section conforming to Gde Fe 410-0 or Fe 310-0 includingnuts, bolts, washers, drilling holes for bolts in any shape or size for fixing ceiling fan complete weighing not more than 2Kg.
S&F in replacement of PVC flexible 3 core 1.5 sqmm cable hrfr with copper con-ductor of size 16/0.20 mm from ceiling rose to fan including connection complete all as specified
M& L for comprehensive maintenance and overhauling of ceiling fans any size at site of any make and size including following works (a) Checking proper working of ceiling fans. (b) Checking of safety pin/sockets/clamps including replacement of unseviceable part (c) Replacement of unserviceable condenser/bearings. (d) Cleaning of ceilingfan/overhauling with fresh grease. Note : 1. Unserviceable parts to be measured & paid seperately under relevant item of Sch A..2 .All T & P and ladder provide to electrician at site by contractor. 3. Penal charges of Rs 100/- Per day will be deduct from contractor for delay beyond 48 hrs from issuing date.
Supply and fix air termination rod single pointed aluminium,12 mm dia and 300 mm long complete all as directed.
Supply and fix aluminium strip 25 X 3.15 mm with PVC saddle and PVC gutties for keeping the gap with roof and wall complete all as directed.
Supply and fix test point terminal block made out of gun metal or phosphours bronze of size 75 x 75 x 25 mm drilled and screwed including 3 Nos. 8mm dia and 25mm long head screw complete all as directed.
Supply and fix GI strip 32 X 6 mm burried in ground complete all as directed.
Supply only PVC insulation tape 18 mm width ISI marked minimum length of tap 15 metre in each roll and make as approved by AGE (I)
S & F in repairs rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
All as per item No 65 above but 25mm dia
S & F in repairs of PVC casing capping 15mm dia alognwith all screws and fixing on wall all as specified and directed by Engr-in-Charge
S & F in repairs of PVC casing capping 20mm dia alognwith all screws and fixing on wall all as specified and directed by Engr-in-Charge
S & F in repairs of PVC casing capping 25mm dia alognwith all screws and fixing on wall all as specified and directed by Engr-in-Charge
S&F Meter box with transperant Lid - of size 600 X 600 X 170 mm (IP-66 and IK-09), 6 way/ 4 way Enclosures made of high quality Polycarbonate (PC-GFS) shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, having high impact, made of halogen, and silica free recyclable material, UV resistant, having high grade, gasket made of Polyurethane, should withstand glow wire test at 960 degree celcius, sholud be flame retardant and self extinguishing, the meter box should have test certificate in accordance with IEC-60 670-22, and CPRI (ASTA) approved, with safe locking sytem for anti- tampering, and necessary in and out terminals for cable, including cutting chasing and fixing to the wall by providing PCC work incl dismantling of old existing complete all as specified and directed by Engr-in-Charge. Hensel or equivalent in Legrand. /L&T
All as per item No 70 above but meter box of size 300 X 300 X 170 mm
M & L for Comprehensive maintenance of water cooler 40/80, 60/120 ltr capacity including performing following tasks at different locations at :- (a) Inspection, dismantling front and rear shutte disconnecting electric and water connection (b) Cleaning thoroughly the body of water cooler including cleaning of cold water tank with bleaching powder solution (c) Servicing of cooling fan by greasing to bearing, oiling to bushes after opening the motor (d) Checking/rectifying the connection and working of thermostat relays, condenser, evaporator, capacities, switches, electrical connection, float valve, compressor earth connection including replacement of defective wire sleeves etc (e) Replacement of PVC drain pipe from water cooler tray to neared drain (f) Reconnecting power and water lines and testing to make it functional complete all as specified and as directed
S & F in repairs of compressor assembly (sealed unit) for water cooler incl testing after gas charging complete all as specified and as directed MAKE : KIRLOSKAR, ACCEL, TECHUMSH (Note : Gas charging shall be measured and paid for separately)
M & L for Gas charging the water cooler with gas R-134/R-22 capacity 40/80,60/120 litres capacity including making necessary connection, testing etc to make it functional complete all as specified and as directed
S & F in repairs of compressor assembly, (Sealed unit) for refrigerator of any size, capacity and make including soldering of copper pipe filling of gas, commissioning and testing all as specified and as directed MAKE : KIRLOSKAR, ACCEL, TECHUMSH Note : Gas charging shall be measured and paid for separately)
S & F in repairs of wood wool pads of best quality as approved with and including wire mesh jalli for desert cooler of any size make and capacity all as specified and as directed
S & F in repairs of PVC pipe of superior quality 15 mm dia suitable for desert cooler all as specified and as directed
M&L for Comprehensive maintenance of desert cooler of any type and any make, fixed at different location a in HQ COSA military station including taking down, cleaning all dirt, dust, oiling of motor and pump, checking of parts, including replacement of nuts bolt, screw etc and preparation of the desert cooler body and tank by scrubbing the old paint and spray painting with two coats of synthetic enamel paint complete all as specified and as directed. Note : Supply and replacement of parts shall be measured and paid separately.
S & F in repairs fan motor for desert cooler complete with blade, locknut, with all accessories 220/250 Volt of all as specified and as directed MAKE : GEC/KHAITAN/CROMPTION/SIEMENS
S & F in repairs of desert cooler pump motor 230/250 Volt,submeible type suitable for 4000 CFM capacity of desert cooler (Head shall not be less than 2 metre) 50 C/S complete with mounting accessories all as specified and as directed MAKE : KHAITAN/CROMPTON/GEC/USHA
M&L for Inspection and maintenance of water heater (Geyser) of capacity, 25 ltrs to 50 litres including performing the following task at different locations of COSA Mil Stn. (a) Removing the heather plate assembly and decaling the heating element/pipe either by use of acid or equa cleaner to make it functional complete (b) Checking and setting of thermostat between 70 to 80 degree Celsius (c) Check working of NRV stop cock, pressure release valve and servicing carefully to make it functional (d) Repairing of earthing connection, power switch, socket connection replacement of indicator lamp to make it functional (e) Examine water leakage and rectifying as required and replacement of rubber washer gasket etc to make it functional (f) Inspect over flow vent pipe, safety valve and remove blockage if required to make it functional
S & F in repairs of heating element of rating 2 KW to geyser 25 to 50 litres capacity, any type, make complete all as specified and as directed MAKE : RACOLD, DASPASS, THEETA
All as per item No 82 here in above but 1.5 KW capacity
S & F in repairs inner copper tank made out of cold rolled pure electrode type copper sheet double lapped welded internally and hydraulically tested for geyser 25 litres capacity complete all as specified and as directed
S & F in repairs of blower motor for inner unit of 1.5 /2 Ton AC split type all as per manufacturer specification complete all as specified and as directed MAKE : LG/KINGSTAR/USHA
S & F in repairs PCB Card for 1.5/2 ton AC complete all as specified and as directed MAKE : LG/KINGSTAR/USHA
S & F in repairs of compressor unit (sealed) completed for 1.5 Ton AC complete all as specified and as directed MAKE : LG/KINGSTAR/USHA
M&L for Comprehensive maintenance of air conditioner split type 15 ton capacity, any make including performing following tasks at different locations at Station :- (a) Inspection, taking down, removing grills and outer housing (b) Descaling, brushing and cleaning thoroughly and replacing filter pad of AC (c) Servicing the cooling fan by greasing/oiling the bearing bushes after opening the motor, cleaning the armature, checking and tightening all nuts and bolts etc (d) Checking rectifying the connection, working of thermostat assembly, relay, condenser, heater assembly, compressor and earth connection etc including replacing defective wire and sleeves etc (e) Re-fixing AC in position, after assembling including packing as required at site and testing complete to make it functional Note : Supplying and replacement of parts shall be measured and paid separately
M & L for repairing to voltage stabilizer 5 KVA/20 Amps 2/3 step, wall mounting digital type including replacement of relay, electronic circuit, connection socket/ terminal, indicating lamp, copper cable of suitable size 3 core with lug connector, voltmeter if required and other defective parts for high and low voltage cut off and automatic adjustment complete all as specified and as directed
All as per item No 89 here-in-above but 4 KVA
All as per item No 89 here-in-above but 3 KVA
M & L for repairing to voltage stabilizer 10/15 KVA/ 2/3 step,3 phase,oil cooled servo type including replacement of relay, electronic circuit, connection socket/terminal, indicating lamp, copper cable of suitable size 3 core with lug connector, voltmeter if required and other defective parts for high and low voltage cut off and automatic adjustment complete all as specified and as directed
Total contract sum shall be calculated after deduction of schedule of credit amount of Rs. 28,795.00
BRICKS ON CLOUD INFRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .