Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹12.4 L+₹2.5 L (25.5%)Rejected-Finance SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L2 | Rejected-Finance being other than lowest bidder | |
| 3 | L3₹13.8 L+₹4.0 L (40.3%)Rejected-Finance | L3 | Rejected-Finance being other than lowest bidder | |
| 4 | L4₹15.4 L+₹5.5 L (56.1%)Rejected-Finance | L4 | Rejected-Finance being other than lowest bidder |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
1 Sept 2020, 6:00 pmClosed
GE AF Jammu
GE AF Jammu
GE/AFJ-07/2020-21- REPAIR/REPLACEMENT OF INTERNAL WIRING, ELECTRICAL FITTING AND FIXTURES INCLUDING DAILY MAINT OF ELECTRICAL COMPLAINTS AT OTM ACCN OF AIR FORCE STATION JAMMU
2020_MES_364573_1
CA NO GE/AFJ-07/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
Jammu
As per tender documents and as per policy in vogue
8 documents required · 8 mandatory
₹500
GE AF Jammu
₹39,000
Yes
28 Sept 2020
27 Jul 2020
3 Sept 2020
27 Jul 2020
1 Sept 2020
18 Aug 2020
Amount
Taking down carefully copper/aluminium point wiring (light, fan,bell, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc . credit for above items should be made as per conditions separately.
Point wiring concealed with 1.5 Sqmm copper conductor cable (multistrand) PVC insulated FRLS (unsheathed), drawing in existing conduit with sunk cast iron/pressed steel terminal boxes made out of 1.2 mm thick sheet including one coat red oxide primer on internal and external surface covered with 3 mm thick hylam brand IS-2036 marked laminated sheet cover (for mounting switches, sockets, regulators etc), including 1.5 Sqmm PVC insulated (multistranded) FRLS copper conductor continuous earth wire for one light /fan point controlled by one switch one way complete all as specified and directed.
Point wiring concealed with 1.5 Sqmm copper conductor cable (multistrand) PVC insulated FRLS (unsheathed), drawing in and including PVC conduit 20 mm dia,cutting chases wall & ceiling and making good to disrurbed surface of wall ,ceiling etc,having wall thickness not less than 2 mm with sunk cast iron/pressed steel terminal boxes made out of 1.2 mm thick sheet including one coat red oxide primer on internal and external surface covered with 3 mm thick hylam brand IS-2036 marked laminated sheet cover (for mounting switches, sockets, regulators etc), including 1.5 Sqmm PVC insulated (multistranded) FRLS copper conductor continuous earth wire for one light /fan point controlled by one switch one way complete all as specified and directed.
All as per item No. 2.00 above but for one multipin 5 amps socket outlet on same board.
All as per item No. 2.00 above but for one multipin 5 amps socket outlet on independent board
All as per item No. 2.00 above but with 2.5 sqmm cable and 1.5 sqmm for earth continuity for multipin 15 amps socket outlet flush type on independent board.
Supply and fixing switch piano button flush type, single pole one way 5 amps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 5 pin socket outlet 2 in 1, 3 pin, 5 amps flush type complete all as specified and as directed by Engineer-in-Charge.
Supply and fixng 5 pin switch socket combination 2 in 1, 5 amps flush type complete all as specified and as directed by Enggineer-in-Charge.
Supply and fixing switch socket combination 5 in 1, 5 and 15 Amp flush type complete all as specified and as directted by Engineer-in-Charge.
Supply and fixing ceiling rose, 3 phase on PVC square blocks surface bakelite 65 x 50 mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge
M&L for sub main wiring with two run of 6.00 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLS cable in and including electrical grade PVC conduits of desired colour not less than1.2 mm thick and of 25 mm dia & 4.00 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one. Make of wire-- Finolex/Havells/Plaza.
M&L for sub main wiring with two run of 4.00 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLS cable in and including electrical grade PVC conduits of desired colour not less than1.2 mm thick and of 25 mm dia & 2.50 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one. Make of wire-- Finolex/Havells/Plaza.
Supply and fixing MCB distribution board Double door SPN 230 volts 12 way with 200 amps rated bus bar, concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc incl taking down the old unserviceable one. Make: Cat part No 5076 12 of Legrand (Ekinoxe) or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32)
Supply and fixing MCB distribution board Double door SPN 230 volts 8 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc incl taking down the old unserviceable one. Make: Cat part No 5076 11 of Legrand (Ekinoxe) or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32)
Supply and fixing MCB distribution board double door 240 volts 4 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc incl taking down the old DBs incl taking down old unserviceable one. Make: Cat part No 5076 10 of Legrand (Ekinoxe) or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32)
Supply and fixing distribution board iron clad TPN DB, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 c/s 4 way, complete with appropriate size copper bus bar. complete with one MCCB 4 Pole 415 Volts 125 Amps rating with rupturing capacity 25 KA of the same make as of distribution board and including cutting chases to wall, concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc incl taking down the old unserviceable one. Make of DB: Legrand Cat part No 6077 60 or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32), Make MCCB: Cat part No 4200 56 of Legrand (Ekinoxe) or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32)
Attending complaints for checking of existing electrical points wiring upto size 6 sqmm in any Buildings including single living accomodations, messes, married accomodations in domestic Area to restore light complaints, including carrying out minor repairs etc as required to make the item functional and replacing burnt wire ends, small pieces of wire, tightning of loose connections etc all as specified. Note- Contractor has to deploy Qualified Electrician and Helper with all necessary tools on all days to the complaint cell and complaints will be attended on the same day itself. Recovery for non attending complaints will be three times rate quoted by the Contractor (Recovery rate will be drieved from the number of complaints on daily basis as mentioned here-in-after) .
Note : (a) Contractor shall provide his Electician and Helper for DOMESTIC AREA along with necesary tools and hardwares to rectify defects from 0830 to 1700 Hrs on all days including Holidays & Sundays. b) One complete month shall be considered as Each job including Holiday and Sunday. Minimum 25 complaints will be considered as daily work. c) The contractor shall depute ITI holder electrician or a retired person having sufficient experience in the trade & semi skilled helper to attend complaits, with proper uniform as finalised by Engr-in-Charge, with name tag. (d) Labour for fixing of new fittings/fixtures including taking down old unserviceable fittings/fixtures for items which have been considered in this BOQ here-in-after as "Supply only" is deemed to be included in overall rates quoted for this item by the tenderer
Attending complaints for checking of existing electrical points wiring upto size 6 sqmm in any Buildings of Technical Area for continuity, no light complaints, including carrying out minor repairs etc as required to make the item functional and replacing burnt wire ends, small pieces of wire, thimbles, tightning of loose connections etc all as specified. Note- Contractor has to deploy Qualified Electrician and Helper with all necessary tools on all days to the complaint cell and complaints will be attended on the same day itself. Recovery for non attending complaints will be three times rate quoted by the Contractor (Recovery rate will be drieved from the number of complaints on daily basis as mentioned here-in-after).
Note : (a) Contractor shall provide his Electician and Helper for TECHNICAL AREA along with necesary tools and hardwares to rectify defects from 0830 to 1700 Hrs on all days including Holidays & Sundays. b) One complete month shall be considered as Each job including Holiday and Sunday. Minimum 25 complaints will be considered as daily work. c) The contractor shall depute ITI holder electrician or a retired person having sufficient experience in the trade & semi skilled helper to attend complaits, with proper uniform as finalised by Engr-in-Charge, with name tag. (d) Labour for fixing of new fittings/fixtures including taking down old unserviceable fittings/fixtures for items which have been considered in this BOQ here-in-after as "Supply only" is deemed to be included in overall rates quoted for this item by the tenderer
Supply only switch piano button flush type, single pole one way 5 amps complete all as specified and as directed by Engineer-in-Charge
Supply only 5 pin socket outlet 2 in 1, 3 pin, 5 amps flush type
Supply only 5 pin switch socket combination 2 in 1, 5 amps flush type
Supply only switch socket combination 5 in 1, 5 and 15 Amp flush type controlled by one switch
Supply only switch bell push piano flush button single pole one way 5 amps complete all as specified and as directed by Engineer-in-Charge
Supply only piano switch two way flush button 5 amps complete all as specified and as directed by Engineer-in-Charge
Supply only flush type fan regulator 230V, electronic rotary stepped increase complete all as specified and as directed by Engineer-in-Charge
Supply only Call bell ding dong AC, 23 Volts, single pole type complete all as specified and as directed by Engineer-in-Charge
Supply only lamp holder insulated body with back plate for batten fitting with LED lamp 08 watt complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 25 x 4 mm galvanised earth strip by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :-
(a) Excavation and earth work for drilling hole for electrode in any type of soil.
(b) PCC pit in cement concrete 1:2:4 type B-1.
(c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm.
(d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
(e) 40 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering.
(f) Requisite quantity of common salt and charcoal.
(g) Testing of earthing.
Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
M & L for rewinding of ceiling fans 1200/1400mm sweep of any make/model, including removal of existing burnt windings carefully from the slots,cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with and including supply of new super enmelled copper winding wire of same gauge/same number of turns as that of existing and connecting the coils suitable to operate on 230 volts single-phase AC supply permanent capacitor type, tying the windings and applying air dry insulating varnish and drying the windings including replacing the defective components such as bearing, capacitor, shaft and painting including assembling after lubricating movable components including testing complete all as specified and directed for :- Note :-(1) Fan will be issued from AGE E/M store yard through gate pass.(2) Bearing/capacitor/etc. will be measured and paid separately under respective item as "Supply only".
Supply only ball bearing suitable for any fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge. Make TATA/SKF
Supply only capacitor of 2.5 Mfd. AC 230/240 volts, 50 Hz Make Epcos
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
Note: (1) The repair has to carried out as and when required basis and accordingly site will be available in piecemeal wise and as directed by Enginer-in-Charge in the Air Force station area
M/s Sahib Construction and engineers
VIDHATA ELECTRICALS
M/S MANJIT SINGH AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .