Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC | ₹22.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹23.6 LRejected-AOC 25 LOKMANYA TILAK PATH RUNIJA ROAD BADNAGAR DISTRICT UJJAIN MADHYA PRADESH | BADNAGAR | UJJAIN | MADHYA PRADESH | ₹23.6 L | L2 | Rejected-AOC L2 |
Updated dates
Tender Value
₹30.9 L
EMD Value
₹61,800
Closing Date
18 Feb 2026, 3:30 pmClosed
CE (EHT-Construction)
Block No. 4, Shakti Bhawan, Rampur, Jabalpur
Repairing and Maintenance of EE-Testing and EE-Maintenance Office Building at Ratlam.
2026_MPPTC_473919_1
1589
Open Tender
Civil Works - Others
120 days
Ratlam
As per tender
14 documents required · 14 mandatory
₹1,770
₹61,800
Yes
26 May 2026
8 Jan 2026
19 Feb 2026
8 Jan 2026
18 Feb 2026
8 Jan 2026
R and M works at EE-Testing & EE-Maintenance Office Building at Ratlam.
15.48,Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
6.5.2,Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. Cement Mortar 1:6 (1 cement: 6 sand).
12.32.2,Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter (minimum wall thickness 2.2mm)
12.33.5.2,Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5o (Eighty Seven Point Five Degree) 110 mm bend (minimum wall thickness 2.2mm)
11.53,Providing and laying Antiskid floor tiles of any sizes, 12 mm thickness with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement with matching pigments etc., complete.
18.6.2.3,Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittingsi/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge...Concealed work including cutting chases and making good the walls etc. 25 mm nominal outer dia .Pipes.
18.6.2.1,Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittingsi/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge...Concealed work including cutting chases and making good the walls etc...15 mm nominal outer dia .Pipes.
18.26.3,Providing and fixing G.I. Union in G.I. pipe inlcuding cutting and threading the pipe and making long screws etc. complete (new work) : 25 mm nominal bore
18.13.1,Providing and fixing CPVC gate valve with knob of approved quality...25 mm nominal bore
2.1.1.1,Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid steel conduit ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit including painting, screwless connector for joints etc. as required as per specification for :- Light point/fan points. Primary short point. ( Using flush type normal accessories)
2.1.1.2 ,Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid steel conduit ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit including painting, screwless connector for joints etc. as required as per specification for :- Light point/fan points. Primary medium point ( Using flush type normal accessories)
2.1.1.3,Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid steel conduit ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit including painting, screwless connector for joints etc. as required as per specification for :- Light point/fan points. Primary long point.
2.1.3.1,Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid steel conduit ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit including painting, screwless connector for joints etc. as required as per specification for :3 Pin 6 Amp socket outlet on separate board Short point.
9.18.1 ,Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutter. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
9.65.1,Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete: 300x16 mm.
9.68.1 ,Providing and fixing ISI marked stainless steel door latches with screws etc. complete : 300x20x6 mm
9.66.1,Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm
9.76,Providing and fixing Stainless steel hanging type floor door stopper with necessary screws, etc. complete.
9.69.1,Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : 125 mm
21.1.2.2,Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, all complete as per architectural drawings and the directions of Engineer-in-charge.
21.3.1,Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. With float glass panes of 4.0 mm thickness.
13.46,Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
13.41,Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete.Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required.
13.3.1,20 mm cement plaster of mix : 1:4 (1 cement : 4 sand)
13.5.2,15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4
13.8,6 mm cement plaster of mix : 1:3 (1 cement : 3 sand)
4.1.1.4,Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : M-10Nominal
1.3.1,Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid steel conduit of ISI marked suitable size including painting etc. as required as per specification 2x2.5 Sq.mm.
1.3.2,Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid steel conduit of ISI marked suitable size including painting etc. as required as per specification 4x2.5 Sq.mm.
13.53,Finishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface)
27.8.1.1,Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole MCB SP 0.5Amp to 5Amp 10kA rating
27.9.1.4,Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'D' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole MCB SP 50 Amp to 63Amp 10kA rating
5.1.1.2 ,Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary medium point. ( Using flush type normal accessories)
5.1.1.3 ,Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- Light point/fan points.Primary long point. ( Using flush type normal accessories)
5.1.3.1 ,Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- 3 Pin 6 Amp socket outlet on separate board Short point.( Using flush type normal accessories)
19.9.1.1,"Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand: 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1cement:2 sand :4 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3
5.1.1,Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete
5.9.1,Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level
5.16.6,Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786
14.64,Chipping, Removing, Carefully loose plaster and Concrete work by low impact Hammer, Breaker without damaging the structure as Instructed by Engineer-in-Charge.
14.65,mixing, laying, levelling, and finishing including.curing etc. complete (excluding steel reinforcement)."
22.23,"Providing water proofing treatment over Roof, Wall, Chhajjas, Balcony with Rubberized elastomeric cold applied liquid waterproofing membrane blend of special resin and rubber with more than 1300% elongation (confirming ASTM-D2370-98), at leakage/seepage area consisting of the following operation. 5 years of service guarantee to be provided. All above operations to be done in order as per direction on Engineer-in-Charge."
22.29,Providing and applying waterproofing & Heat reflecting roof coating with 100% acrylic elastomeric polymers. Contains 30% Volume solid, tensile strength 8 kg/cm*2, crack bridging, VOC 30 +/- 5 gm/ltr upto 2 mm. then applying two coats with forced coverage of 20 sqft/ltr/two coats. The operation shall be carried out after scrapping & propely clening the surface to remove loose particles with wire brush/Jet washer. Apply 1 coat @1 ltr/10 sqm & 3 undiluted coats @ 8 ltr/10 sqm with 4 hrs interval of each coat.The work shall be carried out as recommended by the manufacturer's specification & the direction of the Engineer- in-Charge.
22.3,Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. Apply 2nd coat with filling of crack fill paste when the surface is tacky but not dried completely with putty knife & spatula.After 4 hours of application 2nd coat apply 3rd coat of Crack fill paste. The work shall be carried out as recommended by the manufacturer's specification & the direction of the Engineer-in-Charge
14.83.1,"Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight ofapproved grout injected.)..Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cementslurry made with non shrinkcompound in concrete/RCC work"
14.80.3,"Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight ofapproved grout injected.)..Epoxy injection grout in concrete/RCC work of approved make."
22.22,"Water proofing treatment over Roof, Wall, Chajjas. Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of.(i) Surface preparation roughening of surface, opening cracks in 'V' groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely.. All above operations to be done in order. (five years guarantee)"
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.81 MB
Document358.pdf
Tender Documents • 1.46 MB
Questionnaire.pdf
Other Document • 0.02 MB
BOQ_557188.xls
BOQ • 0.37 MB
AffidavitNew.pdf
Additional Documents • 0.18 MB
Download all tender documents and submit your bid