| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC TULSI ASTHA FLAT NO 1 PLOT NO 54 SECTOR 12 VASHI NAVI MUMBAI THANE 400 703 | THANE | MAHARASHTRA | 400703 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹27.2 L+₹43,920 (1.64%)Rejected-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹28.1 L+₹1.3 L (4.97%)Rejected-AOC G 5 2 1 PANCHADEEP CO OP HSG SOCIETY SECTOR 29 VASHI NAVI MUMBAI 400 703 | THANE | MAHARASHTRA | 400703 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹29.6 L+₹2.8 L (10.6%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹32.1 L+₹5.3 L (19.8%)Rejected-AOC 19 AIRVIEW APARTMENT VAKOLA BRIDGE NEHRU ROAD SANTACRUZ EAST MUMBAI 400 055 | MUMBAI SUBURBAN | MAHARASHTRA | 400055 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
4 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI 400088
ADDN ALTN AND SPL REPAIRS TO TRAINING HALL AND BLDG NO P-14 AND CONSTRUCTION OF RAIN WATER HARVESTING FACILITY AND PROPER CHANNELIZATION OF STORM DRAIN WATER AT NAD UNDER GE (NW) MANKHURD
2020_MES_401474_1
8030/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) MANKHURD
AS PER NIT AND TENDER PAGES
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹80,000
Yes
28 Jan 2021
7 Dec 2020
6 Jan 2021
7 Dec 2020
4 Jan 2021
21 Dec 2020
7 Dec 2020 - 20 Dec 2020
60 days
Amount
Taking down cement plaster or lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris out side MD land including necessary scaffoldings etc complete all as specified and directed
Demolition of cement concrete (unreinforced) in ground floor and paving not exc 15 cm thick (above or below ground level) and removing the retrieved debris outside MD land, complete all as specified and directed.
Taking down wooden chowkats or frames, exc 1.5 sqm but n exc 4 sqm each with shutters (Without taking of shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces, complete all as specified and directed.
Taking down wooden chowkats or frames, not exc 1.5 sqm each with shutters (Without taking of shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces, complete all as specified and directed.
Demolition of brick/cement concrete (unreinforced) from existing roof/terrace etc and also removing/taking down of existing water proofing treatment of any thickness in any position including cleaning the surfaces of roof etc with wire brush complete and removing the retreived debris out side MD land, all as specified and directed.
Demolition of brickwork/stone boulders built in cement mortar including disposal of debris, etc outside MD land complete all as specified and directed.
Dismantling floor, hearth or wall tiling and stone slabs including cement mortar bedding (but not backing), removing rubbish off the premises outside MD Land complete all as specified and directed.
Taking up or down steel tubing of any size and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Taking down existing aluminium joinery of any description (frame/ shutters) with all fittings (but excluding grills) complete all as specified and directed.
M&L for 20mm thick polymer modified ready mix cement based plaster in two layers (12 + 8 mm) on the wall surfaces, mixed with liquid water proofing compound in the proportion as per manufacturer’s instructions and including finishing the surfaces of the top layer even and smooth, complete all as specified and directed, Notes : (i) The thickness of plaster specified above is the minimum thickness and the quoted rates shall also be deemed to include for provision of dubbing of the surfaces with the ready mix plaster and nothing extra shall be payable on this account. (ii) WPC shall be paid for separately.
Chipping, removing carefully loose/damaged concrete incl plastering (total thickness upto 60mm ) from RCC surfaces of columns, beams,Chajas, soffits of slabs etc by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land, complete all as specified and directed. Note: Hard concrete shall not be removed by force.
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hour between the coats, complete all as specified and directed. [Note :- Mode of measurement: superficial area covered between the end to end reinforcement bars (i.e., concrete area excluding all side covers) will be measured.]
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed. Note :- Mode of measurement: superficial area covered between the end to end reinforcement bars (i.e., concrete area excluding all side covers) will be measured.
M&L for providing TMT bars any dia in various structural RCC elements like columns, beams, Slabs etc. including cutting, bending, fixing of bars with welding/ tying as required at site with & including binding wires etc. and all relevant works like anchoring of the bars in the existing RCC Members, complete all as specified and directed.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application complete all as specified and directed.
M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit, upto 20mm thickness while the bonding agent is still sticking including levelling, profiling etc, complete all as specified and directed.
M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit while the bonding agent is still sticking, exceeding 20mm thickness and not exceeding 40mm thickness in two layers, each layer not exceeding 20mm, including levelling, profiling etc, complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 60mm in thickness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit or equivalent of M/s Krishna Conchem as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately).
M&L for leakage / seepage proof coating consisting of preparing the new surfaces of existing exterior walls, parapet walls, chajjas, soffit of beams, columns etc. and applying Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding etc complete all as per manufacturer instructions and all as specified & directed. Notes (i) The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE. (ii) Painting shall be carried out in camouflage pattern as aprroved by the GE.
Supply & Fixing solid PVC door frame of size 50 mm x 47 mm made out of 5 mm wood grain printed PVC sheet reinforced with MS square tube and edges will be painted to match will printed sheet fixed in opening as per specification & drawings complete all as specified and as directed.
S&F Factory Made Solid PVC Moulded Door Shutters with wood free EPS 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing
S&F 100 mm long stainless steel butt hinges fixed with stainless screw complete all as specified and as directed.
S&F aluminum anodised barrel tower bolts of extruded section of size 100 mm length complete all as specified and as directed.
S&F Aluminium handle, cast type anodized size of handle 150 mm complete all as specified and as directed.
S&F Aluminium handle, cast type anodized size of handle 100 mm complete all as specified and as directed.
S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame, shutters for doors, window / ventilators, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes, shall be measured and paid separately as supply only under respective item.
S&F rolled sections as in brackets for resting of chajjas and similar work, conforming to Fe 410 -W (Gde-E-250, quality `B') and including all relevant works, complete all as specified and directed.
M&L for 20 to 25 mm thick machine cut pre-prolished cudappah stone Slabs (table rubbed and polished) as in cills, jambs etc, pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of stone slab etc, including moulding/rounding to edges of the slab and also including provision of 15mm thick screed bed in CM 1:4, complete all as specified and directed.
M&L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in levelling course over RCC roof/ terrace surfaces to achieve required slope, benching etc including making rounded or chamfered on edges mixed with WPC as per manufacturer's instructions, complete all as specified and directed. Note : WPC shall be measured and paid separately as "supply only".
M & L for 10mm thick plaster in cement and sand mortar (1:3) finished even and smooth without using extra cement mixed with WPC over roof/ terrace surfaces, complete all as specified and directed. Note: WPC shall be measured and paid separately as "supply only".
Supply only liquid water proofing compound, complete all as specified and directed.
M & L for APP modified roof treatment over existing roof slab to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fibre weight not less than 160gm/Sq.mtr using butane torch by torch application with 10cm side lap and 15cm end lap. (c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii) Non woven polyester weight not less than 160gm /sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650N/Sqcm and transverse not less than 450 N/Sqcm (v) Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi) Elongation : > 20% in both directions. (vii) Impermeability/water tightness at 2 Kgf/cm2. (viii) Water absorption - Not more than 1% on mass within 24 hours. (ix) Cold flexibility - Minimum (-) 20 degree Celcius. (x) Dimentional stability % change = Maximum 1%. (d) Over the membrane provided a finishing with solar reflective bitumen aluminium paint @ 0.10 Kg/ Sqm as prescribed by manufacturer.
M&L for brick work with sub class B old size bricks and of class designation 35, straight or curved on plan exc. 6mtr mean radius, built in cement mortar 1:6, complete all as specified and directed.
M&L for suspended False ceiling with aluminimum grid work system of size 605 x 605mm with runners aluminimum anodised main Tee of section 35x35x1.5mm thick , cross T of section 25x25x1.5mm thick & Aluminimum anodised angle of size 25mm x 25mm x1.5mm thick fixed along side of wall with wooden plugs & hanging from ceiling/MS purlins with and including 4mm dia GI wire suspension system (upto 1200mm length), adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40mm x 3mm size, 60mm long and expansion hold fasteners 12.5mm dia 40mm long, including necessary scaffolding etc, complete all as specified and directed. Note: Ceiling board / tiles shall be measured and paid separately.
M & L 12 mm thick Perforated particle board/tiles for insulation and acoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid as in ceiling complete all as specified and directed.
M & L Preparation of new wood and wooden based surfaces of any description not other wise described over 10 centimeter width or girth and applying Two coats of synthetic enamel paint over a coat of pink primer in ceiling complete all as specified and as directed.
M & L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms etc including screed bed 15 mm thick in CM 1:4 complete all as specified and as directed.
M & L Light shade digital Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 complete all as specified.
All as per item No 39 above but in skirting including 10 mm thick screed as in backing coat in CM 1:4 complete all as specified.
M&L non skid coloured ceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as in floors over screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
M&L for coloured glazed ceramic tiles of size 300x200x7 mm thick on vertical surfaces such as skirting, dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with the colour of the tiles, over and including 10mm thick cement mortar backing coat in CM 1:4, complete all as specified and directed.
S&F Vitreous china wash down water closet pan “Pedestal Pattern” coloured with WC seat cover coloured closed pattern with flat bottom and mild steel chromium plated or aluminized hinging device including pvc flush pipe and joints etc and connection to drain, flushing, pipe, anti- syphonage pipe, and fixing arrangements with fixing bolts etc ,complete all as specified and directed
S&F in repairs Vitreous China squatting pan “Orissa ” pattern size 580 X 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe ) including connecting to trap and to flushing pipe, etc including making good to dismantled portion of floors with P:C:C type B-0 complete all as specified and directed.
Supply and fixing in repairs 10 litres capacity coloured PVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S & F in repairs Vitreous China Wash hand basin white, flat back, size 550x400 mm size (flat back or angle back type)excluding taps, waste, chain and plug and procelaim stopper but including cutting for and pinning ends of brackets or erecting stand complete all as specified and directed
Supply only 32 mm bore CP brass waste fitting for wash hand basin with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end complete all as specified and directed
S & F in repairs Vitreous China Half stall urinal White complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement with Urinal spreader of PTMT any colour for fixing with 15mm dia pipe complete all as specified and directed
Supply 40 mm bore only CP brass waste fitting for urinal or sink with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed
S & F 40 mm dia High density poythelyne (HDPE) pipes of pressure rating 6kgf/ Sqm complete all as specified and directed .
S&F 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F 15mm dia of fancy type chromium plated two way bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed
S&F 15mm bore brass CP angular stop valve with wall flange, Make ESSCO Cat No MQT 513 A or equivalent of make Kohler or Marc complete all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts of 600mm length complete all as specified and directed
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth
M&L for 75 mm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base of floor, complete all as specified and directed.
S & F door closer hydraulically regulated, designation No. 2, Aluminium (Die cast) body, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 Kg, complete all as specified and directed.
S & F 16 mm dia CPVC pipe with all fittings and fixed complete to walls, ceilings or in floors etc all as specified and dircted.
All as per item No 58 of above, but 20 mm dia complete all as specified and as directed.
S & F Brass CP Tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and directed
S & F 1000 litre Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed
S & F 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed
S & F 20mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed
S & F 32 mm bore dia bottle trap of PTMT having minimum water seal of 25mm (Minimum weight 32mm-260gms/40mm-270 gms) complete all as specified and directed
M & L 75 mm dia outlet PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed
S & F 110 mm dia uPVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed
S & F 110 mm bore uPVC (SWR) soil, waste, ventilating, rain water pipe type 'A', single socketed, (ISI Marked) in any length with and including ruber ring joints, complete fixed to wall with necessary stay PVC standard clamps etc, complete all as specified and directed.
S&F 110 mm bore uPVC(SWR) bends/ Shoes, any radius, fixed to gutter/pipes etc including rubber ring joints, complete all as specified and directed.
S & F 110 mm dia PVC (SWR) bends any radius complete all as specified and directed
S & F 110 mm dia PVC (SWR) branch piece, single (single Y) equal or unequal with oval access door complete all as specified and directed
S & F 110 mm dia PVC (SWR) vent cowl complete all as specified and directed
S & F 110mm PVC (SWR) WC connector with lip ring complete all as specified and directed
S & F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed
S & F Soap dish, vitreous China white, approximate size 160x160x90mm complete all as specified and directed
M & L for 2nd class hard wood exc 13 & n exc 25 Sq cm as in Plain fillets, square, rectangular or triangular in section, clean sawn, secured with mills or brads complete all as specified.
M & L for preparing surface of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with 2 coats of creosoting all as specified.
S & F Solid PVC Wall Lining consisting of 5mm thick Plain colour single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing.
S & F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.
S & F aluminium anodised grill DG-104, 10 mm dia of extruded aluminium section of suitable size and frame including fixing with U clip or F section beading complete with all fitting and fixture and drilling required in RCC section in rectangular or arch type balcony opening of the building complete all as specified and directed
M&L for 10 mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing surfaces even and smooth complete all as specified and directed Note: (i) The thickness of plaster specified above is the minimum thickness and the quoted rates shall also be deemed to include for provision of dubbing of the surfaces with ready mix plaster and nothing extra shall be payable on this account. (ii) This item shall be operated only for the locations where the thickness of existing adjoining plaster is to be matched
M&L for 5 mm thick polymer modified ready mix cement based plaster on surfaces of ceiling including finishing the surface even & smooth without using extra cement, complete all as specified and as directed. Note: The thickness of plaster specified above is the minimum thickness and the quoted rates shall also be deemed to include for provision of dubbing of the surfaces with the ready mix plaster and nothing extra shall be payable on this account.
M & L preparation of newly plastered surfaces and applying 3mm thick wall care putty on wall surfaces.
M & L preparation of newly plastered surfaces and applying 3mm thick wall care putty on ceiling surfaces.
Complete removal of existing treatment, and applying 3 mm thick wall care putty on wall surfcaes
Complete removal of existing treatment, and applying 3 mm thick wall care putty on ceiling surfcaes
M & L for applying two coats of oil bound distemper with roller over one coat of acrylic primer, complete on wall surfaces all as specified and directed.
M & L for applying two coats of oil bound distemper with roller over one coat of acrylic primer, on wall and ceiling surfaces all as specified and directed.
Supply & Fixing 2nd class hard wood plain ,soild straight chowkats and frames of wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed
S & F 35 mm thick, Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified and directed
M&L for applying one coats of synthetic enamel paint over a coat of pink primer complete on old wooden surfaces all as specified and as directed.
M & L for Preparing surface of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint complete all as specified and directed
S&F Mild steel work as in hold fasts, wall ties, , hooks & pintle hinges and similar small articles conforming to Fe-290-0 or Gde E-165 complete all as specified and directed
M&L for treating with tar or coal tar black paint on back of chowkats, ends of posts, holdfasts etc. area not exc 0.1 Sqm each complete all as specified and directed .
M & L for Sanding newly tarred or painted surface with clean sharp sand (Hold Fast) complete all as specified and directed
M&L PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in hold fast, bed plate etc including necessary form work complete all as specified and as directed.
S&F Floor door stopper of Aluminium alloy body and tongue, overall length of cover plate 150 mm , anodized, with hard drawn steel spring , fixed to shutters complete all as specified and as directed.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed length of bolt 300 mm complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating (55% aluminium + 43.5% Zinc+ 1.5% Silicon) GI based corrugated steel sheets as in roofing/wall cladding, 0.50mm thick (total coated thickness) of colour as directed by GE, conforming to AS-1397/ASTM A-792 and having tensile strength minimum 550 Mpa fixed with and including hot dip galvanised, self drilling and self tapping screws neoprene and EPDM washers as per manufacturer's instructions, complete all as specified and directed.
M& L for preparation of new steel and iron surfaces of any description , over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a priming coat of red oxide zinc chrome, complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection 75mm thick, with expansion joints & top surface finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for two coat of acrylic polymer based flexible cementtious elastomiric of make Dr Fixit New coat / Sika Top seal-109 HI/Brushbond of Fosroc Brand/ equivalent of cico/mc-bauchemie) Membrane of about 1-1.5mm dry film thickness over a coat of primer as per manufacturer's instrction over roof slab and taken up to 300mm high in wall etc as per manufacturer's specification.
Demolition of RCC work (any location) carefully without damaging the existing structures / surfaces (including cutting of the reinforcement as required to facilitate dismantling) as in roofs, walls, Chajja etc and similar work by chiseling/wooden mallet / other suitable mechanical means and removal of debris outside MD land, complete all as specified and directed.
M & L RCC M-30 (Design Mix) in Columns, pillars, piers, posts and struts complete all as specified and directed. Note of item No 104 to 105 :- Design mix shall be carried out from approved lab such as IIT/ NIT/ SEMT Pune/ any NABL approved lab/ Govt Engg College
M & L RCC M-30 (Design Mix) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beam, beam hauchings, girders, bressum-mer, lintels, cantilevers, shelves incl supports overhangs, etc also splays between floors and beams complete all as specified and directed.
Excavation in trenches as in mud and n exc 1.5 m in wide and n.exc 1.5m in depth ; for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n exc 1.5m in depth and getting out complete all as specified and directed.
All as per item No 108 above but depth 1.5 m to 3.0 m depth complete all as specified and directed
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation and paving etc complete all as specified & directed.
Surface dressing n.exc 15cm deep in soft/loose soil complete all as specified and directed
M & L for RR masonry walling, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified.
M& L for raised pointing to random rubble masonry uncoursed or brought upto courses in CM 1:4 , complete all as specified & directed.
M&L for pre cast cement concrete block masonry with solid block of grade (C-5) having block density not less than 1800 Kg/cum, exc, 10cm in width and setting in CM 1: 6, complete all as specified and directed.
M&L rendering 15mm thick on fair faces of brick masonary or concrete surface in CM 1:4 finished even and smooth(without using extra cement) mixed with WPC @3% by weight of cement Complete all as specified and directed.
M & L for plain cement concrete 1:2:4 type B-1, using 20mm grade stone aggregate as in coping of stone masonry wall, Header, bed blocks and the like including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified and directed.
Removing excavated material exc 1.5 Km but n.exc 5 km outside MoD land complete all as specified and directed.
Taking down carefully point wiring of any type & pattern (Light/Fan/Socket or power) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etc and making good disturbed surfaces of walls/ roof etc, complete all as specified and directed.
Taking down complete main switches/DBs with enclosure and its components of any size and capacity etc, complete all as specified and directed.
Taking down of earthed metal clad socket outlet with earthed plug top 20 Amp capacity , sheet metal enclosed and one 20 Amp MCB SPN
Taking down and refixing of ceiling fan, ceiling cable and dismantling blades and shifting to MES store yard during other repair work and refixing/ hanging the same at its original location including supply and fixing 1.5 sqmm FRLS 3 core flexible multistranded copper conductor cable, 1100V grade from ceiling rose of suitable length and providing hanging accessories such as rubber reel, cotter pin, nut and bolt including spray painting with 2 coats of synthetic enamel paint servicing and testing for smooth functioning of fan, complete all as specified and directed.
M & L for point wiring complete with proper colour coding, using 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked drawn partly in and including PVC casing caping (minimum 25mm width) fixed on the surfaces of ceiling etc and partly through PVC conduit (minimum 20mm dia) concealed in wall (also including cutting chases in wall and making good the same in CM 1:3 to match with the adjoining surfaces) with all accessories, fittings, PVC junction boxes etc, sunk pressed steel boxes not less than 2 mm thick, 50 mm deep terminal boxes suitable for cover modular plate, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for one light point /fan/bell point controlled by one one way switch, complete all as specified and directed.
All ass per item No 122 above but for One 2 pin/3 pin socket outlet 5 Amps on independent board.
All as per ser item No 122 above but wiring 2.5 Sqmm for 3 pin 15 Amps socket mulitpurpose on independent board complete all as specified and directed.
M & L in repairs for sub main wiring complete with Two runs of 6.0 Sqmm PVC insulated, unsheathed, heavy duty, 1100 volt grade multi-stranded copper conductor cable (FRLS), drawn in and including PVC casing caping fixed on the surfaces of walls, RCC slab/ ceiling/columns / beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 6.0 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continuous earth wire connected to common earth dolly and mains, complete all as specified and directed. Note: Three runs of 6.0 Sqmm PVC cable and one run of PVC Casing Caping will be measured as 'one unit' length.
S&F modular type 120W step fan regulator of 2 module size complete all as specified and directed.
S&F in repairs decorative recessed type LED light fitting 36 Watt (size '2x2') including driver, including provision of 3 core flexible copper cable 1.5 sqmm conductor wire for connecting from ceiling rose to connector, including making addition/altn to existing false ceiling shets aluminium frames including fixing arrangement complete all as specified and directed.
S&F modular type 6A one way SP switch complete all as specified and directed.
S&F ceiling rose, three terminal, 230 Volts, PVC / Polycarbonate body, complete all as specified and directed.
S&F modular type 2/3 pin combined shuttered 6 Amps socket complete all as specified and directed.
S&F modular type 2/3 pin combined shuttered 16 Amps socket complete all as specified and directed.
S&F modular type 16 A one way SP switch complete all as specified and directed.
S&F MCB DB double door SPN 8 way 240 Volts including connecting up with existing cable/ new cable with lugs complete all as specified and directed.
S&F MCB DB double door SPN 4 way 240 Volts including connecting up with existing cable/ new cable with lugs complete all as specified and directed.
S & F MCB, SP, 05 to 32 Amps, 240 Volts, 10 KA Breaking capacity, C-series, complete all as specified and directed.
S & F MCB, SPN, 40 Amps, 240 Volts, 10 KA Breaking capacity, C-series, complete all as specified and directed.
Supply and fixing earthed metal clad socket outlet with earthed plug top 20Amp capacity , sheet metal enclosed and one 20 Amp MCB SP all as specified and diredted.
M & L in repairs for sub main wiring complete with Two runs of 4.0 Sqmm PVC insulated, unsheathed, heavy duty, 1100 volt grade multi-stranded copper conductor cable (FRLS), drawn in and including PVC casing caping fixed on the surfaces of walls, RCC slab/ ceiling/columns / beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 4.0 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continuous earth wire connected to common earth dolly and mains, complete all as specified and directed. Note: Three runs of 4.0 Sqmm PVC cable and one run of PVC Casing Caping will be measured as 'one unit' length. Note : A sum Rs 15,175.00 towards sch of credit shall be deducated to arrive the contract sum
mp construction co
M/s Hari Om Construction
Parmatma Enterprises
GAJANAN SALES CORPORATION
S.N Enterprises
SRINIVASA BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .