| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.6 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹38.8 L+₹2.2 L (5.91%)Rejected-Finance H NO 13149 STREET NO 3 SHIV COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹39.7 L+₹3.1 L (8.46%)Rejected-Finance MCB Z 5 04939 GURU GOBIND NAGAR BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | 3 | Rejected-Finance Not Lowest |
Tender Value
₹36.4 L
EMD Value
₹72,800
Closing Date
9 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Abohar
Garrison Engineer Abohar Pin-152116
Provn of Stn Store Room at Trg Room of Inf Bn-III and other sanctioned works at Abohar Mil Stn
2020_MES_407527_4
GE ABH-42/20-21
Open Tender
Civil Works
Item Rate
180 days
Abohar Mil Stn
MES Registered Contractor enlisted in class E Category a (i) having deposited standing security of Rs 50000 with departments. Contractors not registered in MES should meet the MES enlistment criteria corresponding to appropriate class and category
5 documents required · 5 mandatory
₹500
Garrison Engineer Abohar
₹72,800
Yes
14 Aug 2021
18 Jun 2021
12 Jul 2021
18 Jun 2021
9 Jul 2021
26 Jun 2021
60 days
Amount
SCHEDULE 'A' SECTION I (B&R Portion)
Excavation in trenches in exc 1.5 m wide and not exc 1.5 M depth for foundation and getting out in soft and loose soil all as directed.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25 cm all completed as specified in soil
Removing excavated material exc 250M but n.exc 500m and depositing where directed at a level n.exc 1.5M above the starting point.
M & L cement concrete 1:4 :8 type D2 using (40 mm graded aggregate) as in filling, fdn, mass concrete and sub base of floors all as specified and directed.
M&L for Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or batter etc rough finished surfaces of concrete all as specified and directed..
M&L for Form work to sides of pillars, posts, struts, piers, columns of any Section(square, rectangle and circular) and stanchions etc. rough finished surfaces of concrete all as specified and directed.
M&L for Form work to sides and soffits of floor roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams, etc rough finished surface of concrete all as specified and directed.
M&L for Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc.200 mm thick(horizontal or sloping)rough finish surface of concrete flat all as specified and directed.
M&L for Form work to edges of concrete flats, treads breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roof n.exc. 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but N. exc 20cm wide, roughed finished surfaces of concrete all as specified and directed.
M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges.
M&L TMT bars 10mm dia & over cut to length bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
All as per srl item ser No 12 here-in-before but 5mm dia and over up to and including 10mm dia as in stirrups complete .
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in as in foundations, footings, foundation beams, plinth beams; bases for columns, etc. and mass concrete complete.
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in Columns, pillars, piers, posts & struts etc. all as specified and directed . (form work & reinforcement measured separately).
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5 metre span all as specified and directed. (form work & reinforcement measured separately).
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate in slab supported on walls, beams and columns in floors,roofs,landings,balconiies,deck slabs and in shelves and the like all as specified and directed. (form work & reinforcement measured separately).
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in chajjas all as specified and directed. (form work & reinforcement measured separately).
M & L for 40mm thick damp proof course in cement concrete 1:2:4,type B-0 to horizontal or vertical surfaces including necessary formwork all as specified and directed.
M & L brick work with Flyash bricks straight or curved onplan exc 6 m mean raidus built in cm 1:6 all as specified.
Spreading and levelling in layers N.exc. 25cm thick and well ramming including watering as required under floors;all as directed.(in floor with available earth from excavation approved by Eng-in-charge)
M&L for hardcore of gauge n exc. 63mm deposited spread and levelled in layers n exc. 15cm thick watered and rammed to a true surface in broken brick completed all as specified and directed.
M & L 75mm thick PCC 1:4 :8 type D2 using (40 mm graded aggregate) as in sub base of floors all as specified and directed.
M & L Machine cut kota stone slab flooring 20 - 25 mm thick over cement screed base laid over and including 15mm thick screed bed in cement mortar 1:6 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as directed.
M & L Machine cut kota stone slab 20 - 25 mm thick in riser of steps,skirting,dado and pillar over cement screed base laid over and including 10mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as directed.
M&L rendering 15 mm thick in CM 1:4 including water proofing compound on fair face of brick or concrete surface,finished even and smooth without using extra cement complete .
M&L rendering 10mm thick in CM 1:6 on fair face of brick or concrete surface,finished even and smooth without using extra cement complete .
M&L for rendering 5 mm thick in CM 1:3 on ceiling, finished the surface even and smooth without using extra cement all as specified and directed.
M&L for preparation of newly plastered and unplastered surfaces of wall by applying two coats of interior grade wall putty( 1mm thick of each coat) manually and making it smooth with sand paper by mechanical method i.e. with hand electric grinder and then applying two coat of weather coat emulsion over one coat of primer manually complete all as specified and directed by Engr-in-charge.
M&L for preparation of newly plastered and unplastered surfaces of wall by applying two coats of interior grade wall putty( 1mm thick of each coat) and making it smooth with sand paper by mechanical method i.e. with hand electric grinder and then applying two coat of oil bound distemper over one coat of cement primer including all as specified and directed by Engr-in-charge.
M&L three coat of white wash on ceiling including necessary preparation of surfaces all as specified.
M & L providing two coats of synthetic enamel paint over new surface and a coat of red oxide primer on steel surfaces including preparation of surface of any description not exceeding 10 cm width or girth all as specified .
M & L providing two coats of synthetic enamel paint over new wooden surface including preparation of surface with primer all as specified .
Providing and applying microfibre reinforced UV resistant Acrylic polymer coating three coats having solid contents 69% polymer content 35% & tensile strength 2.6 N/mm2 of Dr. Fixit Newcoat/stat/Parex or equivalent with a paint brush over existing roof surface after removal of all loose material, lime dust etc. with wire brushes, coir brushes from roof surface to get absolutely cleaned surface free of foreign contaimnant filling of cracks wherever found with polymer based mortar, and after repairing the surface apply primer coat with Dr. Fixit Primeseal. Polyester reinforced fiber net laid on the surface after the first coat and all the joints of bricks is repaired by polymer based mortar. Undulation on the surface repair before executing the water proofing treatment including 15mm thick plaster in CM 1:4 as screed finished even joint of slab and wall of roof complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick pcc 1:3:6 type C-1 using 20mm graded mechanically crushed stone aggregate as in Plinth protection finished even and smooth without using extra cement with & including 10mm wide,30mm deep joint at the rate of 3 mtr centre to centre and at every turning &filling the joints with bitumen &sand mixture complete all as specified and directed.
Supply only integral waterproofing compound
S& F Drapory curtain rod of 25 mm dia decorative type with brass coated ends caps includinf fixing arragements like brackets,stops,rollers etc. all as specified and as specified.
S&F Factory made box type steel window with hung shutter both glazed and gauged ,shutter frame 60x25mm ERW hollow 'P' section with wall thickness not less than 1mm fixed to pressed steel frame 120mmx 70mmx1.6mm thick including fixing glazed portion,iron grills 8mm suare MS bar hunges with steel handle and fitting, lugs etc, including one coat of primer complete all as shown in drg No BTD 889 sheet 1/4 to 4/4 specified and directed.) (Note :- Wire mesh and glass shall be measured and paid separately under relevent items of shch/BoQ)
S & F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane all as specified .
S & F framed work such as grills, cooler stand ,grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming to Fe 410-0 or Fe 310-0 all as specified .
S & F pressed steel door frames size of 125X60mm with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified
M&L Cement concrete 1:3:6 type C-1 for filling of pressed steel fram and hold fast blocks etc all as specified .
S & F Factory made Plain framed, panelled shutter IInd class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated
S & F Factory made 35mm thick IInd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats all as specified .
S & F mild steel butt hinges, medium weight 100 mm size fixed with steel screw all as specified.
S & F aluminium tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm long all as specified .
S & F aluminium bow handle stove enamelled black, 150 mm long all as specified .
S & F mild steel sliding door, bolts, plate type, stove enamelled black with bright bolt not less than 12mm bore, length of bolt 250mm all as specified .
S & F mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified .
S & F small fittings such as door stops and like, including all necessary labours articles not exceeding 200 Cucm each of 2nd class hard wood all as specified .
S & F Vitreous china Oval type Counter wash hand basin screwed shank fly nut flange end including cutting for and pinning in granite slab of hole including 32 mm dia chromium plated waste coupling and bottle trap all as specified .(MAKE-Hindware,Parryware,Cera or equivalent )
S&F Granite work 20 mm thick (table rubbed and polished) in steps, cooking platforms and the like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust and admixture of pigment to match with shade of granite.
S & F soap dish fixed as chromium plated.Make -ESSESS AC-103 .
S&F 15mm bore stop valve fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed.
S & F in PVC connection 15mm size with PTMT nuts of length 450mm all as specified .
S/F as in pillar taps 15mm bore cast copper alloy fancy type with capstan heads chromium plated scre-wed down high pressure with or without lettered hot' or'cold' with long screwed shanks and fly nuts screwed for iron pipe . ISI marked
S&F rotational moulded polyethene water storage tank ( cylinderical verticle with closed top) hoisted and fixed in position all as specified in SSR Part-I. (Cap 1000 ltrs capacity).
S & F in 20mm bore Ball brass valve high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed all as specified .
S & F in 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified .
S&F PVC ( SWR) pipes bore of 110 mm single socketed in any length with rubber ring joints fixed to walls all as specified
S&F PVC ( SWR) bends any radius bore of 110 mm all as specified
S&F PVC ( SWR) pipes bore of 110 mm single socketed in any length with rubber ring joints laid in trenches or in floors all as specified
150mm bore salt glazed stone ware pipe Grade ‘A’ as in trenches at any depth complete all as specified (Excavation , earth work & concrete shall be measured and paid separately).
PCC (1:4:8) type D-2 using 40mm graded stone aggregate , concrete bed to drains laid to falls in trenches in any depath inl. Packing under and haunching against the sides of SGSW pipes 150mm bore after the pipes have been laid jointed and tested all as specified.
Cutting into existing manholes for connecting new drains, making good to pipe and ren-dering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement con-crete 1:2:4 type B-1 smooth finished, and reforming bench-ing as required (Internal Dia of pipe in 150mm)
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out on soft or loose soil
M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken bricks
M&L for PCC 1:4:8 Type D-2 100 mm thick as in sub base all as specified.
M&L for Machine pressed precast conctete coloured with grey cement and pigment interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and directed.
M&L Sand filling under floors or in foundation including watering & consolidation
M&L for continues brick edging with burnt clay brick work with sub class ‘B’ with width equal to width of brick laid dry on end vertically.
M & L for Vitrified ceramic Dark shade/double charged/ultra charged with matt finish, 10 mm thick ( square/ rectangular ) area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:6) complete all as specified and directed by Engineer - in - Charge.
Ditto all as above but as in skirting over 10 mm cement mortar backing ( 1:3).
S & F anodised aluminium frame with extra powder coating for doors, windows, with one or more rebate including joining cleat for fixing etc complete.
Anodised door shutters aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips rubber neoprene packing handles 2 nos on each door, hinges anodised aluminium snap beading screws etc with powder coating of any colour (thickness of powder coating not less than 50 micron) complete.
S & F powder coated aluminium sliding window three track with frame & two glass shutters using 4 mm thick glass tinted modi guard and one shutter with stainless steel wire gauge wire cloth 0.31 mm nominal dia of wire and width of aperture 1.61 mm using aluminium powder coated section aluminium cleat ,PVC track ,bearing, handle lock,rubber beading etc complete fittings as approved. Note:- Size of aluminium section shall be under- (i) Three track top and vertical - Jindal main-2010 section No 20621 or equivalent as approved by GE. (ii) Three track bottom - Jindal main - 2010 section No 20620 or equivalent as approved by GE. (iii)Shutter vertical section -Jindal main -2010 section 20604 or equivalent as approved by GE . (iv)Shutter top and bottom - Jindal main -2010 Section 20604 or equivalent as approved by GE. (v)Shutter vertical middle (interlock) - Jindal Main -2010 Section 20605 or equivalent as approved by GE.
S&F anodised aluminium grill of daimond size 100x100mm of dia 6mm including necessary joining cleats , anodised aluminium snap beading screws , complete all as specified .
S&F aluminium anodised barrel tower bolt of extruded section 100mm long
S&F aluminium anodised barrel tower bolt of extruded section 150mm long
S&F 5.50 mm thick sheet glass and glazing with necessary rubber packing and glazing clips not exceeding 0.50 sqm in each pan complete all as speified
Demolition of cement concrete (un-reinforced) in floors/ paving , (below or above ground level) and of any description and in any position not otherwise all as specified & directed by Eng-n-charge
Demolition of cement concrete (reinforced) in roof, floors (otherwise than ground floor), beams, staircase, landing, chajjas and similar suspended work
Reinforced cement concrete nominal mix Type 1:2:4(20 mm graded stone aggregate) in slab supported on walls, beams and columns in floors, roofs , landing , balconiies,deck slabs and in shelves and the like all as specified and directed (forms work & reinforcement measured separately
All as above but except bricks all as specified
M & L for brick work in work in half brick thick wall using fly ash bricks straight or curved on plan to any radius bulit in cement mortar (1:4) complete all as specified and directed by Engineer-in- Charge.
Dismantling of floor hearth or wall tilling including cement motar bedding (but not backing) and rubbish off the permices
M & L for joint free Non skid ceramic coloured tile 7 to 8 m thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. over and including 15mm thick screed and bedding in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or colour cement to match with existing specified & directed by Eng-n- charge
M & L for glazed ceramic colouredhick 300 x 450mmsize in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmeneted to the shade over 10mm thick cement sand screed (1:4) complete all as specified & directed by Eng-n- charge
M & L Machine cut kota stone slab florring 20-25mm thick over cement screed base laid over and including 20mm thick screed bed in cement mortar (1:4) set and jointted with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as directed
M & L Machine cut kota stone slab florring 20-25mm thick in riser of steps , skirting dado and pillar over cement screed base laid over and including 20mm thick screed bed in cement mortar (1:4) set and jointted with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as directed
Cutting, grinding, cleaning and trating the surface of existing kota stone flooring withbeeswax polishing complete as directed by Engr-in Charge
Taking down chokats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.5 Sqm each and all as specified.
Taking down chokats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.5 Sqmbut not exceeding 4 Sqm each and all as specified.
Refixing in same opening but area exceeding 1.00 Sqm and not exceeding 2.0 Sqm all as specified
Taking down shutters but area excedding 1.00 Sqm and not exceeding 2.0 Sqm all as specified
S & F for Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness . The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminated shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glas from all sides. M.S saty shall be provided at the bottom to steady the frame complete as specified by the manufacturer and as per direxctions of Engineer-in- charge
S & F to existing frames 30 mm thick Glass Fibre Reiforced Plastic (FRP) panelled dooe shutter of required colour and approved brand and manufacture made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fitting, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, includung fixing to frames, complete as specified by the manufacturer and as per direction of Engineer-in-charge
S & F PVC butt hinges, medium weight 100 mm size fixed with steel screw all as specified
S & F tower bolt 150 mm of PTMT all as specified
S & F door handle D type 150 mm of PTMT all as specified
S & F pressed steel door frames with one or more rebates including neceessary fixing 0lugs hinges lock strike plate etc complete all as specified size of frame 105X 60MM all as specified
S & F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless stell wire staples all as specified
S 7 F figured glass 4 mm thick pin head type and glazing with oil putty and securing with glazing pins not exceeding 0.50 Sqm in each oan complete all as specified
S & F Floor door stopper of aluminum allow body and tongue 150mm overall length, anodised with hard drawn steel spring, fixed in floor.
Dismantling wrought iron or mild steel work of any description all as specified.
S & F Hard drawn steel wire fabric not exc 4Kg/Sqm cut to length bent to shape required and tying with and includig mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed inreinforcement all as specified & directed by Enineer-in-Charge.
M & L proving kitchen cabinet in required sizes at site made out of 18 mm thick one decorative lamination sheet consisting of caress 18mm thick PVC & provision of shutters made out of 18mm thick one side decorative laminted PVC sheet all required brackets 5.5 screws etc. The panels shall be fabricted using adhesive and screws where ever reuired . all the edges shall be covered with 2mm thick edge bonding taoe or 900 degress edge bent finish as per make and specification mentuioned as drawing and specifiction approved by Eng-in-Charge (a0 PVC 18mm Celluca Ply (Prelam) for shutters.
(b) Dittto all above PVC Sheet 18mm Prelam for frame, partition shelves etc
S & F Stainless steel soft close crank hinges suitable size and shape as required all as specified and directed
S & F Magnetic catcher fied in with nut, screw, washer complete all as specified and directed by Eng-in Charge
S & F 100mm extuded brass handles, fabricted type polished for cabinet shutters complete all as specified and directed.
S & F sink made of Stainless Steell 1 mm thick kitchen with plub washer and waste including bedding in cement mortar to dwarf wall inclunding fixing contilever brackets connecting union to pipe over all size 495x 420 mm bowl of size 410x 330x 160mm fixed in repair
S & F in repair 15 mm bore bib tap fancy type chromium plated with crutuh or butterfly handle screwed down,screwed for iron pipe all as specified
S & F in repair 15 mm bore pillar tap fancy type chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe all as specified.
S & F 15 mm bore stop valve fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both end s for iron pipe or for unions all as specified and directed
S & F squatting pan orissa pattern, vitreous china white of size 580 x 440 mm with integeral foot rest, including necessary lime concrete and CI 'P' trap for WC with cement joint, complete all as specified.
S & F PVC high or low level cistern of 10 litres capacity including 32mm dia. Flush pipe and internal fitting complete all as specified
S & F vitreous china wash hand basin, white flat back of size 550x 400 mm including waste coupling, waste pipe and bracket complete all as specified.
S & F in repirs CP Towel rail 16 mm dia 600mm long superior quality complete all as specified
S & F soap dish fixed as chromium plated all as specified & directed.
Taking down steel tubing 15 mm bore and connections complete all as specified.
Fixing only tubes any grade 15 mm bore to walls and ceilling or in floors etc includiing provision of new fitting as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) all as specified.
S & F 15 mm bore medium grade tube galvanised with all fitting and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor all as specified.
Taking down steel tubing 20 mm bore and connections complete all as specified
Fixing only tubes any grade 20 mm bore to walls and ceiling or in floors etc including provision of new fitting as required (serviceable galvanised tubes retrieved from respective items shall be laid under these items) all as specified
S & F 20mm bore medium grade tube galvanised with all fitting and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor all as specified
S & F Grating doom 125mm dia with waste hole of PTMT( Min wt 40gm)
S&F 75mm PVC(SWR0 floor trap plain with grating including jointing with solvent cement
S & F PVC (SWR) 110 mm bore vent cowls complete all as specified and directed and directed by Engr-in-charge
S & F PVC (SWR) 75mm bore junction (SingleT) equal or unequal
S & F PVC (SWR) 110mm bore junction (SingleT) equal or unequal
Taking down CI/AC/PVC soil waste and vent pipe any radius including all fitting complete
S & F PVC (SWR) pipesbore of 75 mm single socketed in any length with rubber ring joints laid in trenches or in floors all as specified
Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc.
M&L for rending 10mmthick in CM1:3 on ceiling, finished the surface even and smooth without using extra cement all as specified and directed.
M & L rendering 15mm thick in CM 1:6 on fair face of brick or concrete surface, finished even and smooth without using extra cement complete.
M & L for prepartion of Old plastered ceiling surfaces and applying two coat of white wash including prepartion of surfaces complete all as specified & directed by Eng-in-Charge
M &L for prepartion of newly plastered wall surfaces and applying three coat of White wash complete all as specified & directed by Eng-in-Charge
M & L for prepartion of old plastered wall surfaces and applying one coat of white wash including prepartion of surface complete all as surfaces complete all as specified & directed by Eng-in-Charge
M & L for prepation of old plastered wall surface s and applying two caot of cement based paint over a coat of clearcolle primer complete all as specified & directed by Eng-in-Charge
M & L for prepartion of old plastered wall surfaces and applying one coat of cement based paint including prepartion of surfaces by washing, rubbing down and stopping of painted surfaces all as specified & directed by Eng--in-Charge
M& L for prepartion of old wooden surface and applying one coat of synthetic enamel paint over a coat of pink primer complete all as specified.
SCHEDULE 'A' SECTION-II (E&M PORTION)
M&L point wiring (CONCEALED) for using 1.5 sqmm nominal cross sectional area copper conductor mutimultistranded ,PVC insulated unsheathed , FRLS cables in and including using PVC conduits not les than 20 mm dia and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multi-multistranded copper conductor , FRLS, green PVC insulated unsheathed earth wire and connecting to earth dolly using color code as per IS and making good all disturbed work to match the existing for One light/fan/bell point controlled by one 5 Amps one way switch and all as specified and brass screws, washers etc. complete all as specified.
All as per Item No.146 here in before but for One three pins 5 Amps switch socket outlet point on independent board
All as per Item No. 146 here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches
Description all as per item No 146 here in before but for 15 amps socket outlet with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
Description all as per item No 146 here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
S & F switch piano ,flush type single pole, one way 5 amp, all as specifed and directed by Engr-in-charge.
S & F switch piano flush type single pole one way 15/16 Amp complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps complete.
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps and 15 Amps complete.
M & L for celling rose 3 pin/pvc/ polycarbonate insulated body complete all as specified and as directed.
Supply and fix in replacement of FTL, LED type tube light along with fixture environmental friendly 1x18W, 230v, 6000K(4') complete all as specified and directed
M&L for LED building street light luminaire of capacity 20 Watt with pressure die-cast housing with individual LEDs as light source and lens embedded PC cover having TOP opening separate driver compartment with IP 66 protection and impact resistance of IK 07 Make: Bajaj BRLEPLED 20W LED V2 or equivalent in Havlls/Crompton Greaves/ Philips/Wipro/Syska as approved by GE.
M&L for LED Batten with LED tube light integrated LED channel of capacity 10 Watt white colour complete all as specified and directed by Engr-In-charge. Make: Bajaj BCLSB 10WH or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Syska/Polycab as recommended by Engr-Incharge and approved by GE.
S & F ceiling fan 1200 mm sweep 5 star rating , single phase 240 volts complete with electronic type regulator and accessories.
Dismantling of existisng unserviceable MCB distribution board and S&F sheet metal enclouser TPN DB having facility to fix MCCB in incomer upto 125Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-54 protection Isolated Neutral bar,door earthing,cement spill ptorector and blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
S&F sheet metal enclouser SPN DB having facility to fix MCB in incomer and MCBs in outgoing, SPN 8 ways, Double door type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
S&F sheet metal enclouser SPN DB having facility to fix MCB in incomer and MCBs in outgoing, SPN 4 ways, Double door type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
S&F MCB SPN 63 Amps, 240 Volts complete all as specified.
S&F MCB SP 6 to 40 Amps, 240 Volts complete all as specified.
Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells Schneider/C&S)
S & F submain wiring with two single core cables PVC FRLS insulated unsheathed 6 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC insulated 6.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer-in-Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
M & L lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete, Make- Anchor/SSK/CONA
Supplying, laying, jointing and testing XLPE PVC insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 16 sqmm 4 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earht wire lead of 4 mm dia fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and water pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip upto DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
S&F Exhaust fans 300 mm sweep 230/240 volts single phase with self closing louvers off mode protection against birds etc and provision of cutting of walls and necessary plastering and making good the disturbed surface to match with existing complete all as specified.
S & F in sheet metal enclosures for DBs double door type when MCBs to be used single pole & nuteral 8 ways s all as specified and directed by Engg-in-Charge.
Supply and lay GI Pipe medium class including fittings of size 25 mm dia
Supply and fix stop valve screwed of size 40 mm dia. Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
Supply and fix stop valve screwed of size 25 mm dia. Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
Supplying, laying, jointing and testing XLPE PVC insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 10 sqmm 2 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes
Removing excavated material exc 50M and depositing where directed at a level n.exc 1.5M above the starting point.complete all as specified
M & L brick sub class B locally available best quality laid in trenches above sand consolidted forcable protection complete all as specified and directed.
Supplying laying, jointing and testing XLPE PVC insulated heavy duty multi starnded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 35 sqmm 3.5 core conforming to IS -1554 laid in trenches/ ducts/along poles/through pipes including provision of cable gland/ aluminium lugs complete all as specified & directed by Engineer -in- charge
Taking down carefully copper/aluminium oint wiring (light, fan, socket or power) complete incl fixture and fitting such as switches , cellong roses , pandents regulators, sockets, lights fitting etc removing materials to store for keeping in safe custody for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surface of wall floors etc complete all as specified and as directed.
M & L point wiring (concealed) with PVC FRLS insulated unsheathed multistarnded copper conductor drawn in and incl of size 1.5 Sqmm, 1100V gradein concealed PVC regid conduit, including provn of 1.2mm thich pressed steel sunken treminal boxes 60mm deep, suitable lenthand painted with red oxide primer for mouting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminted sheet top cover fixed flush with wall using brass screws & cup washers including 1.5 Sqmm PVC insulated stranded copper conductor as earth continuity wire and connected to common earth dolly with copper lugs inserted in including MS boards complete heavy duty for housing switches, sockets regulators, be, complete all as directed for the following (A) One light / Bell/fan point controlled by one way switch 5 Amp
(B)One 3 pin socket outlet , 5 Amps on the same board with otherswictches, with cable 1.5 sqm size complete
(c) One 3 Pin socket outlet 5 Amps on independent board with other switches, with cables 1.5sqmm size complete
(d) Ditto but with cable of 2.5 sqmm for 15 amps Sockets Independent board with other switches complete all as specified.
Descripition all as per item No 08 here in before but for 15 amps sockets outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
M & L point wiring with PVC FRLS insulated unsheathed multistranded copper conductor of siz e 1.5 Sqmm 1100V grade in Existing concealed conduit, and one run PVC FRLS insulated unsheathed copper conductor ofze 1.5 Sqmm as earth dolly with copper including provn of 1.2mm thick pressed steel sunken terminal boxes 60mm deep suitable length and painted with red oxide primer in place of unserviceable shunken box complete for housing switches , regulators bell push etc, complete all as directed for the following (a) One light / fan point controlled by one way piano switch 5 Amp
(b) One Socket point 5 Amp on a independent board
(c) One socket point 5 Amp on same board
(d) Ditto but with cable of 2.5 sqmm for 15 amps Sockets Independent board with other switches complete all as specified.
M & L for LED tube light fitting of LED T5 tube lights (6500K0 environmental freiendly energy efficicient of 18/20 Watt LED including electric connection with PVC copper flexible twin core cable 1.0 sqmm from celling rose to light fitting complete all as specified and directed by Engr-In Cahrge Make: Syska SSK SQ2001 20W or equvalent of Havells/Crompton Greaves / Philips/Wipro/Polycab as recommended by Engr-In Charge and approved by GE
Supply and fix in replacement of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete
S & F Sheet enclouser TPN DB (LOAD LINE) having facility to fix MCCB incomer upto 125Amps and MCBs in outgoing TPN 8 ways Double door type complete fitted with bus bars neutral links IP-43 protection Isolated Neutral bar door earthing cement spill ptorector and blanking plates including making good distrurbed surfaces complete all as specified and directed make Legrand / L& T Hager/C& S/INDO Kopp/Indo Asian/ Standard/Havells
S & FMCB SPN 40 Amps 240 Volts complete all as specified.
M & L for for submain wiring comprising single core, 2 Runs of 10 sqmm nominal cross sectional area multimultistranded copper conductor cable , PVC insulated unsheathed 1100Volts grade drawing in and including appropriate dia PVC conduits and conduit fiitting / existing concealed PVC conduit and conduit 2 x 6 sqmm nominal cross sectional area multimuitistranded copper conducter cable PVC insulated unsheatheed 1100Volts grade as earth wire and using color code as per IS and specified and making good all distured works to match the existing complete incl taking down old UNSV sub main all as specified
Descripition all as per item No 193 here in before but 2 Runs of 6 Sqmm nonimal cross section and including provision of 1x 4 o sqmm nonimal cross sectional area for earth wire complete all as specified and directed
Descripition all as per item No 193 here in before but 2 Runs of 4 Sqmm nonimal cross section and including provision of 1x 4.0 sqmm nonimal cross sectional area for earth wire complete all as specified and directed
M & L cutting chases pinning in making god to facing where reuired and pointing in cement mortar 1:3 to ends or edges of landing , steps cills sunshades, shelves , lintels, etc and cutting chases for concealed water tubing or concealed wiring etc and making good cutting chases for concealed water tubing or concealed wiring etc and making good scutting not exc 10cm girth in brick walls complete all as directed by Engr-in-charge
Supplying, laying, jointing and testing XLPE PVC insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 16 sqmm 4 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes
S & F LED street light luminaitres 20/25 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe brackets made out of 25mm dia medium grade pipe (60 cm long) bend to shape including fixing arragenement to awll with MS flat 25x3mm Nos by nut bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting complete all as specified and diected by Engr-In-charge Make Sysska max glow series SSK /Phillips/ Wipro/Polycab as recommended by Engr In Charge and approved by GE
Supply and fixing MCCB TPN (4 pole) 63 Amps 415 Volts of bracking capacity 36 KA (Adjustable Thermal and Adjustable Magnetic Release Setting) complete taking down old unservicable one and making nessary connection as existing and cleaninig the terminals with CTC solutions complete all as specified and directed
S & F batton holder insulated body with back plate including 12 watts LED lamp complete all as specified
S & F GI tube light grade galvanised of size 50mm with all fiitting and fixed to wall and celling or laid in floors for cable protection complete all as specified and directed by E-In-C (Make Jindal/Prakash /Surya
M &L for PCC prepartion including cutting up to 45cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as directed by the Engr. in Charge
S & F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for hot/coldwater
S & F copper (CP) hot water pipe 450mm length (heavy duty) for Geyser, connection with check nut and washer.
S & F BLDC (brushless direct current) Motor Ceiling fan 1200 mm sweep 5 Star rating single phase 240 volts power consumption 26 watt to 32 Watt on turbomode with remote control 220 CUM/Min Single phase 50Hz 240 Volts warranty 2 years on products complete and accessories Make atomberg Gorilla/ Havells Efficiencia Neo/ Crompton/White or equvalent of CG/ Luminous/ Orient
S & F Geyser storage type, driven of capacity 25 Ltrs 5 star rating with 8 bar pressure with standing, rut proof fire retardant cable adj thermostat anti corrosion protective device inner tank mild steel with glass lined coating including PVC connection and grouting of bolts with nut of suitable size including cement works for make good the disturbed surface etc complete all as specified and as directed Make Bajaj cat No Caldia or equavalent in CG, Havells
S & F Exhaust fans (Heavy duty) 450 mm sweep 230/240 volts single phase with self closing louvers GI off mode protection against birds etc and provision of cutting of walls suitabully for fixing exhaust fan and necessary plastering and making good the disturbed surface to match with existing complete all as specified make: Havells ventillar DB 300 mm or equavalent of Orient/ Usha
M & L for Boring hole across the Road/ plinth/hardstanding/path /drain/pavement etc. suitable for inserting HDPE/GI pipe of upto 100 dia bore pipe for 0.4 mpa working pressure for cable passing without damanging existing Road/apth /hardstanding/floor by trenchless technology or manual using neceesary equipment compelete all as specified and directed
M/s Verma Construction Company
M/s GURFATEH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .