Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance HOUSE NO 1777 NEAR ARCHANA APARTMENT MUL ROAD UTTAMA NAGAR CHANDRAPUR 442401 MS | CHANDRAPUR | CHANDRAPUR | MAHARASHTRA | 442401 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance AT POST NANDGAON PODE TAH BALLARPUR DIST CHANDRAPUR | BALLARPUR | CHANDRAPUR | MAHARASHTRA | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹7.7 L
EMD Value
₹9,600
Closing Date
1 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer EnM, Ballarpur Area
Office of Area General Manager,EnM Department, WCL Ballarpur Area
Erecting of LT OH lines approximately 1 KM for power supply of new siding at Gouri Deep OCM of Ballarpur Area
2022_WCL_247164_1
ba3650-enm-018-2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
730 days
Office of Area General Manager, EnM Department, WCL
Please refer Tender documents.
6 documents required · 6 mandatory
₹9,600
Yes
2 Jul 2022
18 Jun 2022
2 Jul 2022
18 Jun 2022
1 Jul 2022
18 Jun 2022
18 Jun 2022 - 21 Jun 2022
Amount
Erecting rolled steel joist (girder) pole 200 x 100 mm. (25.9 kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ (19 Nos, 9m each)
Supplying and erecting 12.5m (clear height) Fixed type High Mast (Top-110mm, Bottom- 242 mm) with hexagonal/round bracket and foundation bolts suitable for max. 6 nos floodlight fixtures on provided foundation as per specification no.OH-PL/OPL (excluding luminaries).
Erecting ACSR conductor of size 6/1-3.66 mm complete.(Mink) (255 kg/km) as per specification no. OHCON/ ACSR
Erecting inline D. P. structure for 11/0.415 kV, 200 kVA transformer with R.S.J. pole 2 nos. of size 100 x 116 mm x 11 Mtr. long with suitable distribution box of C.R.C.A. sheet 16 SWG with 4 pole MCCB 300 amps as incomer & 6 nos. 100 amps kitkat/MCCB for outgoing circuits. Transformer D.P. structure includes the A. B. switch 200 amps, D.O. fuse set & L.A. set, 2 nos. of top channel of size 100 mmx 50 mm for erection of A.B. switch & 2 nos. base channel of size 100 mm x 50 mm for erecting Transformer. channel of size 75 x 40 mm for erecting D.O. fuse set, L.A., A.B. switch handle etc. Angle of size 50 x 50 x6 mm for erecting distribution box, transformer belt etc.as per drawing (min. 124 Kg. iron work) with necessary clamps, nut-bolts, vee cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. structure shall be erected in c.c. foundation complete.
Installing, testing & commissioning of 3 phase, 11/0.433 kV, 50 Hz., 63 kVA, oil immersed and naturally cooled outdoor type, copper wound transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40oC by thermometer in oil and 45oC by the resistance in winding at full load rating, with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, with standard accessories complete with test certificate with losses below 340 Watts at 50% load, 1140 Watts at 100% load as per IS:1180 - 2014 energy efficiency level II, with necessary permissions of Electrical Inspector, as per specification no SS- TR.
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles)
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).
Supplying and erecting porcelain disc type insulator with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI
Supplying and erecting pin type LT medium insulator 100 mm x 62 mm dia. with suitable G.I. spindle, nut, bolts complete erected.
Supplying and erecting vee cross arm with ISM channel of 75x40x6mm, for 11kV HTOH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220 mm bent at angle of 60 degree keeping base 305 mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts,washers complete as per specification no. OH-PL/VCA
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/10 SWG, G.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation.
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EAEP
Supplying & erecting 100 x 50x6 mm with 4.7 mm thick web and 7.5 mm thick flange channel iron cross arm of suitable length for 2.4m wide DP structure and erecting on DP with 50x6 mm clamp as per approved method of construction and complete as per specification no. OH-PL/BKT.
Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600 mm in length and 65 x 65 x 6mm thick erected on pole as per specification no. OH-PL/VCA
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 25 to 50 sq. mm. cable, with necessary material as per specification no. CB-JT/LT
Supplying , erecting & terminating 3 x 95 sq. mm. aluminium 11 kV(E), XLPE armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification no. CBHT
Supplying and erecting flood light luminaries suitable for 400W H.P.S.V. lamp complete with accessories on provided bracket as per specification no. FG-ODF/GFL
Supplying and erecting ant climbing devices, fabricated from pole clamps of MS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole complete.
Total impact of GST for the purpose of CTC
P R Electricals
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .