Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.6 LAccepted-Finance WZ 66 SRI NAGAR RANI BAGH NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | ₹8.6 L | L-1 | Accepted-Finance All documents are found eligible as per NIT |
| 2 | L-2₹9.3 LAccepted-Finance | ₹9.3 L | L-2 | Accepted-Finance All documents are found eligible as per NIT |
| 3 | L-3₹10.4 LAccepted-Finance B 1124 SHASTRI NAGAR DELHI 110052 | NORTH | DELHI | 110052 | ₹10.4 L | L-3 | Accepted-Finance All documents are found eligible as per NIT |
| 4 | L-4₹11.0 LAccepted-Finance | ₹11.0 L | L-4 | Accepted-Finance All documents are found eligible as per NIT |
| 5 | L-5₹11.3 LAccepted-Finance G 15 PKT 2 NARAINA VIHAR NEW DELHI 110028 | NEW DELHI | DELHI | 110028 | ₹11.3 L | L-5 | Accepted-Finance All documents are found eligible as per NIT |
Tender Value
₹15.2 L
EMD Value
₹30,402
Closing Date
10 Apr 2026, 3:00 pmClosed
Executive Engineer(Elect.)
Seed Bed Park School Block DDA Complex Shakarpur Delhi-92
Running maintenance and Operation of various E and M Services at Pkt-9A, Jasola.
2026_DDA_904260_1
01/EE/ELD-1/DDA/NIT/2026-27
Open Tender
Electrical Works
365 days
As per NIT
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹30,402
Yes
In the chamber of EE(E)/ELD-1/DDA
23 Apr 2026
1 Apr 2026
11 Apr 2026
1 Apr 2026
10 Apr 2026
3 Apr 2026
2 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | 1.0) RMO of various E & M services like DG sets, lifts , Internal light fittings of Common Area of Pkt -9A , Jasola 3 Nos. Operator cum Technician Gr-II for 3 shift (each of 8 hrs shift) i.e. 6.00 AM to 2.00 PM and 2.00 PM to 10.00 PM & 10 PM to 6 AM daily for 368 days. | - | Per Month | - | - | BI01010001010000000000000515BI0100001113 |
| 2 | 2.0) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initialLumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trademark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm | - | - | - | - | BI01010001010000000000000515BI0100001114 |
| 3 | 2.1) 18- 22 watt | - | Each | - | - | BI01010001010000000000000515BI0100001115 |
| 4 | 3.0) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in recessed steel/ PVC conduit as required. the existing surface | - | - | - | - | BI01010001010000000000000515BI0100001116 |
| 5 | 3.1) 1 x 1.5 sq. mm | - | Meter | - | - | BI01010001010000000000000515BI0100001117 |
| 6 | 3.2) 3 x 2.5 sq. mm | - | Meter | - | - | BI01010001010000000000000515BI0100001118 |
| 7 | 3.3) 3 x 4 sq. mm | - | Meter | - | - | BI01010001010000000000000515BI0100001119 |
| 8 | 4.0) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and ommissioning etc. as required. | - | - | - | - | BI01010001010000000000000515BI0100001120 |
| 9 | 4.1) Single pole | - | Each | - | - | BI01010001010000000000000515BI0100001121 |
| 10 | 5.0) Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. | - | - | - | - | BI01010001010000000000000515BI0100001122 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.19 MB
Tenderdocument01ELD01.pdf
Tender Documents • 7.41 MB
BOQ_950452.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid