Executive Engineer, PHD, PWD, Puducherry
Executive Engineer, PHD, PWD, Puducherry
Providing of 22 KV 433V, 315 KVA Distribution Transformer and obtaining LT CT operated service connection to the Over Head water tank at Jayamoorthiraja Nagar, Velrampet Puducherry.
2023_PWDC2_13869_1
28/PHD/2023-24/02
Open Tender
Civil Works - Water Works
Item Rate
30 days
Uppalam
Please refer Tender documents.
3 documents required · 3 mandatory
₹525
₹57,261
28 Jun 2024
4 Oct 2023
11 Oct 2023
4 Oct 2023
10 Oct 2023
4 Oct 2023
Amount
Supply and erection of 22KV Double pole structure as per following specifications:30 feet RCC Pole 2nos, 100x50mm channels, angles, Transformer bed channels, clamps bolt nuts and 22KVAB switch operating handle -1set,22KV pin insulator HG fuses, 22KV Lighting arrestor, 0/2 SWG copper Jumpering and alkathine pipes, other supporting insulators and iron materials and necessary civil works etc.,
Supply of ACSR conductor of 7/2.59 sqmm diameter including binding etc., as required.
Erection of ACSR conductor of 7/2.59 sqmm diameter including binding etc., as required.
Supply of 30' RCC pole
Erection of 30' RCC pole in cement concrete foundation 0.45 x0.45 x 1.0 mts and coping 0.45 x 0.45 x 0.5 mts with ratio 1:3:6 uing 20 mm HBG metal including cost of concreting materials uch as cement, jelly sand etc., excavation of pit and refilling.
Supply of HT stay set complete with rod , bow 9" x 9" x6 mm thimble and guy shackle inulator.
Supply of H.T.tapping channel of size 100 x 50 x 50 x 10 mm for 11/22 KV overhead line.
Erection of H.T.tapping channel 100 x 50 x 50 x 10 mm for the 22 KV overhead line including drilling of holes for insulator and clamp.
Supply of 11KV Disc insulator for 22 KV overhead line with2 sets of 11 KV disc insulator.
Erection of 11KV Disc insulator for 22 KV overhead line with 2 sets of 11 KV disc insulator complete metal parts as required..
Supply of All sizes of M.S. bolts and nuts.
Supply of rail pole clamps, stay clamp, RCC pole clamp etc..
Supply of 22KV Pin insulator.
Erection of 22 KV pin insulator
Supply of 22KV GI pins
Supply, Erection and Testing and Commissioning of 315 KVA ,22 KV /433V, 3phase 50 Hz, H.V.& L.V. bushing type, copper wound Energy Efficiency Level-2 Distribution Transformer as per IS 1180/2014-Part 1 Amendment No.4, ONAN, Off Load Tap switch having 7 positions with voltage correction insteps of 2.5% (+5% to -10%), with All relevant accessories shall be provided confirming to IS 1180/2014, including first filling of oil and as per Pondicherry Electricity Department specification.
Providing of foundation for outdoor type 315 KVA , 11/22 KV / 433 v, distribution tranformer.
Supplying and installation of following safety equipments as per statutory norms and IE / CEA regulations 1. fire bucket with tand -1 no. II. Fire extinguisers for electrical fire - 3 nos. 3. Rubbermat as per latet IS - 12m 4. First Aid chart, 5. First Aid Box, 6. Danger Board.
Making earth pit of G.I. pipe for earthing in earth pit with 40mm dia. G.I. pipe medium class of length 3.05m perforated with 46 Nos of 12mm dia. holes, pipe lowered in bore holes of 150mm dia. and filled in with charcoal and salt in alternative layer of 300mm, the top of G.I. pipe shall be clamped. Earth pit shall be provided with 60cm dia precast ring with 60cm depth alround,covered with R.C.C. precast slab etc. as per I.E. standards.
Supplying and fixing of G.I. flat (25 x 6mm) for earthing arrangements including bolts and nuts etc.
Providing and fixing 4.00 mm dia copper wire on surface or inrecess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.
Supplying of 3 1/2 x 400sqmm armoured aluminium U.G cable -1.1KV grade at site.Make:- Polycab/Finolex/Havells.
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - above 185 sq.mm and upto 400 sq.mm.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X400 sq.mm (82 mm)
Supply of 630A, 400V, 6 way Sub-Station pillar box with 14 SWG CRCA sheet and HRC fuses on required bus bars and neutral bus bar made-up of electrical grade aluminium and separate galvanized copper earthing flats and other features as PED specifications .
Erection of Distribution / SS pillar on MS channel including provision of pillar plinth.
Supplyying and fixing CT metering panel as per Electricity Department specification . Panel board board of size 1800 mm x 900 mm x 300 mm made of 18 gauge CRMS sheet painted with two coats of enamel paint over zinc chromate primer with necessar MS base channel. The panel board shall include power mat, copper bus bar, 8 mm thick Hylem sheet of size 84 x 54 cm.
Design and Supply of 250A four pole LT heavy duty switch diconnector fuse unit of ize 800 mm x 475 mm x 275 mm wall mounted type.
K S MANI ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .