220 KV SUBSTATION SECTOR-20 NOIDA
Installation, Erection, Testing and Commissioning of 132/33kV, 100 MVA Transformer in place of 63 MVA T/F-IV (ECE Make) against Increasing capacity including all other associated works at 220kV Sub-Station, Sector-129, Noida, under ETDI Noida
2026_UPTCL_1191852_1
E-ST-16/ETCN/2026-27
Open Tender
Electrical Works
Item Rate
30 days
NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ETD NOIDA
₹10,000
1 Oct 2026
1 Oct 2026
13 Oct 2026
1 Oct 2026
12 Oct 2026
1 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Installation, Erection, Testing & Commissioning of 132/33kV, 100 MVA Transformer in place of 63 MVA T/F-IV (ECE Make) against Increasing capacity including all other associated works.
Complete dismantling of the accessories of 132/33kV 63 MVA T/F-IV (ECE make) at 220 KV S/S Sector-129 including removal of all radiators, conservator tank, oil pipe lines, bushings , filling of oil in drums/oil tanker (20KL/50KL) etc. and shifting/stacking them at proper place near store as per the instructions of JE/SDO including all other associated works and T&P required to complete the work satisfactorily. | 1 | Job | - | - |
| 2 | Shifting/Dragging of Main Tank of 132/33kV 63 MVA T/F-IV (ECE make) from plinth to Nearby Location as per the direction of JE/SDO at 220 kV Sub-Station Sec-129, Noida. | - | - | - | - |
| 3 | Upto 20 Mtrs distance | 1 | Job | - | - |
| 4 | Additional shifting of 60 Mtrs. (5 mtr per job) | 12 | Job | - | - |
| 5 | Shifting/Dragging of Main Tank of 132/33kV 100 MVA T/F-IV (Aditya make) from nearby location to plinth as per the direction of JE/SDO at 220 kV Sub-Station Sec-129, Noida. | - | - | - | - |
| 6 | Upto 20 Mtrs distance | 1 | Job | - | - |
| 7 | Additional shifting of 60 Mtrs. (5 mtr per job) | 6 | Job | - | - |
| 8 | Complete safe erection of 100 MVA , 132/33kV T/F including all its Bushings & Turrets, A-Frames with headers (including alignments), Radiator banks, Conservator Tank, connecting oil pipelines, motor driven mechanism of Tap Changer, Marshalling Box and associated pipe lines etc. to complete the job satisfactorily. | 1 | Job | - | - |
| 9 | Hot Oil Circulation of T/F oil of 100 MVA , 132/33kV T/F in Main Tank, Radiators or Oil Tanker by connecting 8/12 KL Centrifuging Machine with New Filters for dehydration of oil, windings etc. and taking & recording BDV values oî oil and IR values of transformer windings periodically till the required value is reached including filling & topping up of oil in Main Tank, Radiators, Conservator Tank, OLTCs etc. as per direction of Supervising Engineer/standard practices. | 23 | KL | - | - |
| 10 | Earthing with 75x10/50x6mm M.S Flat of 100 MVA , 132/33kV T/F Main tank at two points, Neutral Bushings, Drive mechanism etc. of T/F and connection with existing Earth Mat / Delta along with necessary modification , jointing/ welding are required including painting by green paint in two coats. (MS Flat shall be arranged by the Department. | 1 | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_2248880.xls
BOQ • 0.27 MB
DOCTS-16.pdf
Tender Documents • 11.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .