| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-Finance | ₹28.1 L | L1 | Accepted-Finance Quoting Lowest Rate |
| 2 | L2₹28.2 L+₹3,101 (0.11%)Rejected-Finance | ₹28.2 L+₹3,101 (0.11%) | L2 | Rejected-Finance Quoting Higher rate |
| 3 | L3₹28.2 L+₹3,656 (0.13%)Rejected-Finance | ₹28.2 L+₹3,656 (0.13%) | L3 | Rejected-Finance Quoting Higher rate |
| Sl No | Description | Qty | Unit | M/S SAHARA ENGINEERING L3 | JASODA REFRIGERATOR SERVICING CENTRE L2 | SNOW FLAKE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing & Commissioning of 5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 60000 BTU/hr (17.58KW) with 2 Nos. compressor (Rotary / Twin Rotary / Scroll), 2 nos. 2.5 TR each IDU of rated power supply - 240V (+/-5%), 1ph, 50Hz., 1no. ODU of rated power supply - 415V(+/-5%), 3ph, 50Hz. Air-flow/per IDU :- 1000CFM. Refrigerant R32 / R410A.
The indoor unit must be suspended from ceiling / wall with all necessary structure as per requirement and tie rod incl. necy. Painting as per direction of EIC. PCB of the AC unit must be enclosed in Metal Enclosure to prevent fire.
(Make : Hitachi / O-General / Mitshubishi Electric / Daikin as per direction of EIC). | 2 | Nos | 1,90,000 ₹3,80,000 Lowest | 1,90,990 ₹3,81,980 | 1,90,900 ₹3,81,800 |
| 2.00 | Supply, Installation, Testing & Commissioning of 3 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 36000 BTU/hr (10.54 KW) with 2 Nos. compressor (Rotary / Twin Rotary / Scroll), 2 nos. 1.5 TR each IDU of rated power supply - 240V (+/-5%), 1ph, 50Hz., 1no. ODU of rated power supply - 415V(+/-5%), 3ph, 50Hz. Air-flow/per IDU :- 650CFM. Refrigerant R32 / R410A.
The indoor unit must be suspended from ceiling / wall with all necessary structure as per requirement and tie rod incl. necy. Painting as per direction of EIC. PCB of the AC unit must be enclosed in Metal Enclosure to prevent fire.
(Make : Hitachi / O-General / Mitshubishi Electric / Daikin as per direction of EIC). | 1 | Nos | 1,20,000 ₹1,20,000 | 1,19,990 ₹1,19,990 | 1,19,900 ₹1,19,900 Lowest |
| 3.00 | Supply, Installation, Testing & Commissioning of 2 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr (7032 watts). with 1 No. Rotary compressor with R410A/R32 Refrigerant,1 nos. IDU of rated power supply-230V-1ph-50Hz, 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 800 CFM.copper condenser.
The indoor unit must be suspended from ceiling / wall with all necessary structure as per requirement and tie rod incl. necy. Outdoor unit must be fixed with suitable size bracket/ angle iron frame. Painting as per direction of EIC. PCB of the AC unit must be enclosed in Metal Enclosure to prevent fire. (Make : Hitachi / O-General / Mitshubishi Electric / Daikin as per direction of EIC). | 3 | Nos | 1,00,000 ₹3,00,000 | 99,000 ₹2,97,000 | 98,900 ₹2,96,700 Lowest |
| 4.00 | Supply, Installation, Testing & Commissioning of 1.5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 18000 BTU/hr (5274 watts). with 1 No. Rotary compressor with R410A/R32 Refrigerant,1nos. IDU of rated power supply-230V-1ph-50Hz, 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 650CFM.copper condenser.
The indoor unit must be suspended from ceiling / wall with all necessary structure as per requirement and tie rod incl. necy. Outdoor unit must be fixed with suitable size bracket/ angle iron frame. Painting as per direction of EIC. PCB of the AC unit must be enclosed in Metal Enclosure to prevent fire. (Make : Hitachi / O-General / Mitshubishi Electric / Daikin as per direction of EIC). | 13 | Nos | 78,000 ₹10,14,000 Lowest | 78,200 ₹10,16,600 | 78,190 ₹10,16,470 |
| 5.00Supply, installation & commissioning of Easy to bend, Corrossion free Annealed Copper refrigeration pipe line complete with fitting, elbows, bends, supporting arrangement (G.I. saddle) on wall. | ||||||
| 5.01 | a) Liquid Line (3/8" OD with 0.6mm thick) (make: Godrej /Carrier Total Line / MI Copper or brand approved by EIC) | 60 | Mtr | 220 ₹13,200 Lowest | 225 ₹13,500 | 222 ₹13,320 |
| 5.02 | b) Liquid Line (1/4" OD with 0.6mm thick) (make: Godrej /Carrier Total Line / MI Copper or brand approved by EIC) | 270 | Mtr | 160 ₹43,200 Lowest | 165 ₹44,550 | 162 ₹43,740 |
| 5.03 | b) Suction line (5/8" OD with 0.7mm thick) (make: Godrej / Carrier Total Line / MI Copper or brand approved by EIC) | 330 | Mtr | 400 ₹1,32,000 | 390 ₹1,28,700 | 388 ₹1,28,040 Lowest |
| 6.00 | Supply & Fixing Pipe Insulation in Liquid/Suction line with 9 mm Nitrile rubber tube for above Concealed split Ac machine (Make: Accoroflex/ Suprime) and covering with self adhesive Aluminium foil tape as per direction of EIC. | 330 | Mtr | 80 ₹26,400 Lowest | 90 ₹29,700 | 88 ₹29,040 |
| 7.00 | Supply & laying PVC Drain Pipe 25 mm dia (Make:Suprime/Oriplast meduum guage/ Sch 80). incl. All accessories tee, bends etc., and supporting clamps, as per direction of EIC. | 385 | Mtr | 180 ₹69,300 | 170 ₹65,450 Lowest | 170 ₹65,450 Lowest |
Tender Value
Refer Docs
EMD Value
₹62,900
Closing Date
10 Apr 2026, 11:00 amClosed
Sr.Superintending Engineer
Office of the Sr. Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Repair and Renovation work for Psychiatry Department at Burdwan MCH, Purba Bardhaman -- SITC of AC Machine.
2026_WBPWD_1020436_1
WBPWD/SSEWEC /BED /NIQ-106 /2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Purba bardhaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹62,900
Office of the Sr. Superintending Engineer, Western
13 May 2026
10 Mar 2026
13 Apr 2026
10 Mar 2026
10 Apr 2026
16 Mar 2026
10 Mar 2026 - 16 Mar 2026
16 Mar 2026
Supply, Installation, Testing & Commissioning of 5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 60000 BTU/hr (17.58KW) with 2 Nos. compressor (Rotary / Twin Rotary / Scroll), 2 nos. 2.5 TR each IDU of rated power supply - 240V (+/-5%), 1ph, 50Hz., 1no. ODU of rated power supply - 415V(+/-5%), 3ph, 50Hz. Air-flow/per IDU :- 1000CFM. Refrigerant R32 / R410A. The indoor unit must be suspended from ceiling / wall with all necessary structure as per requirement and tie rod incl. necy. Painting as per direction of EIC. PCB of the AC unit must be enclosed in Metal Enclosure to prevent fire. (Make : Hitachi / O-General / Mitshubishi Electric / Daikin as per direction of EIC).
Supply, Installation, Testing & Commissioning of 3 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 36000 BTU/hr (10.54 KW) with 2 Nos. compressor (Rotary / Twin Rotary / Scroll), 2 nos. 1.5 TR each IDU of rated power supply - 240V (+/-5%), 1ph, 50Hz., 1no. ODU of rated power supply - 415V(+/-5%), 3ph, 50Hz. Air-flow/per IDU :- 650CFM. Refrigerant R32 / R410A. The indoor unit must be suspended from ceiling / wall with all necessary structure as per requirement and tie rod incl. necy. Painting as per direction of EIC. PCB of the AC unit must be enclosed in Metal Enclosure to prevent fire. (Make : Hitachi / O-General / Mitshubishi Electric / Daikin as per direction of EIC).
Supply, Installation, Testing & Commissioning of 2 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr (7032 watts). with 1 No. Rotary compressor with R410A/R32 Refrigerant,1 nos. IDU of rated power supply-230V-1ph-50Hz, 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 800 CFM.copper condenser. The indoor unit must be suspended from ceiling / wall with all necessary structure as per requirement and tie rod incl. necy. Outdoor unit must be fixed with suitable size bracket/ angle iron frame. Painting as per direction of EIC. PCB of the AC unit must be enclosed in Metal Enclosure to prevent fire. (Make : Hitachi / O-General / Mitshubishi Electric / Daikin as per direction of EIC).
Supply, Installation, Testing & Commissioning of 1.5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 18000 BTU/hr (5274 watts). with 1 No. Rotary compressor with R410A/R32 Refrigerant,1nos. IDU of rated power supply-230V-1ph-50Hz, 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 650CFM.copper condenser. The indoor unit must be suspended from ceiling / wall with all necessary structure as per requirement and tie rod incl. necy. Outdoor unit must be fixed with suitable size bracket/ angle iron frame. Painting as per direction of EIC. PCB of the AC unit must be enclosed in Metal Enclosure to prevent fire. (Make : Hitachi / O-General / Mitshubishi Electric / Daikin as per direction of EIC).
Supply, installation & commissioning of Easy to bend, Corrossion free Annealed Copper refrigeration pipe line complete with fitting, elbows, bends, supporting arrangement (G.I. saddle) on wall.
a) Liquid Line (3/8" OD with 0.6mm thick) (make: Godrej /Carrier Total Line / MI Copper or brand approved by EIC)
b) Liquid Line (1/4" OD with 0.6mm thick) (make: Godrej /Carrier Total Line / MI Copper or brand approved by EIC)
b) Suction line (5/8" OD with 0.7mm thick) (make: Godrej / Carrier Total Line / MI Copper or brand approved by EIC)
Supply & Fixing Pipe Insulation in Liquid/Suction line with 9 mm Nitrile rubber tube for above Concealed split Ac machine (Make: Accoroflex/ Suprime) and covering with self adhesive Aluminium foil tape as per direction of EIC.
Supply & laying PVC Drain Pipe 25 mm dia (Make:Suprime/Oriplast meduum guage/ Sch 80). incl. All accessories tee, bends etc., and supporting clamps, as per direction of EIC.
Supply & Laying of 1.1KV grade following size
a) 4 Core 2.5 Sq.mm
b) 4 Core 4 Sq.mm
Supply and fixing flexible double canvass connection for concealed split air-conditioners, complete in all respect, from IDU to continuous grill, as per direction of EIC.
Charges for making & fixing of trap door with ACP Sheet (Mk. Aludecor / Pratap Bond or brand approved by EIC) of 3mm thick (0.25mm AL.+ 2.5mm LDPE + 0.25mm AL PVDF in existing aluminium channel & ACP board for IDU maintenance.
Supplying, fabrication & fixing 2 Nos. M.S. Angle of size (50 mm x 50 mmx6mm) for making platform for installation of outdoor unit of 5 & 3.0 TR Concealed split AC incl. drilling 2 nos holes in each Angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (40 mm x 40 mm x 6 mm) Angle inserted into the exiting wall. Area of the platform is 2Mtr. x 1Mtr. or as per Machine configuration & load with adequate service access incl. painting of the entire structure as per direction of EIC.
Charges for lifting of Indoor, Outdoor units & all material for making out door Srructure frame incl. scaffolding arrangement as per requirement of all complete as per direction of EIC.
Dismantling of the existing split type AC machine (1.5/2.0 Ton) along with the outer cover carefully by skilled labour from its position for necy. Servicing /overhauling incl cleaning the dust ete. due to dismantling operation and also uninstalled & removing of unused old damaged windows AC unit from wall and covered the vacant space by ACP board with necessary dimension with good mending and damages as per direction of EIC as per direction of E.I.C.
Re-installation of the dismantelled AC units at suitable location after making holes in wall by expert labour also mending good after complete the work. Connecting the pipe line testing the leak by gas pressure (minimum 400 PSI ) and vacuuming the unit properly (Minimum -30 PSI), hold the vacuum up to 48 hours, after release the gas testing the Split type Room Air conditioner incl. gas charging as per requirement and replacement of existing capacitor with metal body P2 capacitor with supply & fitting adjustable powder coated painted heavy duty iron bracket. as per direction by EIC.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 17.49 MB
new2911.pdf
Tender Documents • 0.51 MB
BOQ_2508312.xls
BOQ • 0.29 MB
Corriedate.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .