Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.0 LAccepted-AOC 5 KEDAR APARTMENTS 484 60 PARVATI MITRAMANDAL COLONY PARATI PUNE 411 009 | PUNE | PUNE | MAHARASHTRA | 411009 | ₹58.0 L Quoted ₹58.6 L | L1 | Accepted-AOC ACCEPTED BEING L1 |
| 2 | L2₹61.5 L+₹2.9 L (4.98%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹61.5 L+₹2.9 L (4.98%) | L2 | Rejected-Finance REJECTED BEING L2 |
| 3 | L3₹63.8 L+₹5.3 L (8.98%)Rejected-Finance PLOT NO 14 NEAR BALGRAM INS SHIVAJI ROAD LONAVLA 410 401 | PUNE | MAHARASHTRA | 410401 | ₹63.8 L+₹5.3 L (8.98%) | L3 | Rejected-Finance REJECTED BEING L3 |
Tender Value
Refer Docs
Closing Date
27 Oct 2021, 6:00 pmClosed
CE(NW)KOCHI
CHIEF ENGINEER (NW) KATARIBAGH, NAVAL BASE-PO KOCHI-682 004
SPECIAL REPAIRS TO BUILDING NO. P-331 (CAUVERY BLOCK) AT INS SHIVAJI LONAVLA
2021_MES_473396_1
890997/E8
Open Tender
Civil Works
Item Rate
365 days
LONAVLA
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
GE(I)(NAVY)LONAVLA
Exempted
20 Nov 2021
7 Sept 2021
29 Oct 2021
7 Sept 2021
27 Oct 2021
8 Oct 2021
Amount
Taking down cement plaster of any description and in any position of brick or concrete surfaces & racking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing removing materials and rubbish off the premises complete all as specified and as directed.
Dismantling of stone slabs or tiles of any description or thickness in floors/walls laid bedded and pointed in any mortar complete all as specified and as directed.
Demolition of unreinforced cement concrete of any description and in any position complete all as specified and as directed.
Taking down steel/Aluminium windows/ventilator of any size with all fittings complete all as specified and as directed.
Taking down chowkats or frames with shutter (without taking of shutter from the frame) exc. 1.50 Sqm but not exc 4 Sqm each complete all as specified and as directed.
Taking down chowkats or frames not exc 1.5 sqm each but with shutters (without taking off shutters from the frame) complete all as specified and as directed.
Taking down shutters of any description not exc 1.0 sqm each complete all as specified and as directed.
Material and labour for plain cement concrete type D2, 1:4:8 using 40mm graded stone aggregate as in foundation filling and mass concrete all as specified and as directed.
Material and labour for 40mm thick plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in flooring complete all as specified and as directed.
Material and Labour for coloured vitrified ceramic tiles 10mm thick (square/ rectangular), light shade, area of each tile not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed.
Material and labour for 20mm thick Granite (of any type) work (table rubbed and polished)in steps, jambs, pillars, window-cills, cooking latforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
Material and Labour for non-skid coloured Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not excceding 0.11 sqm, in floors etc, set and jointed in mortar and pointed in white of coloured cement to match over and including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed.
Material and labour for glazed ceramic jointless coloured tiles in vertical surface such as walls/ skirtings, size of tile 300x600x7mm/ 450x350x7mm thick set and jointed in neat cement slurry fixed over backing coat of 10mm thick in CM 1:3 complete all as specified and as directed.
Supply and fixing pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed.
Supply and fixing 30 mm thick 2nd class hard wood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats complete all as specified and directed
Supply and fixing 35mm thick factory made 2nd Class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc., (without sash bars), edges of framing plain chamfered or rounded, fitted with beads for fixing glass, size of members of shutters as specified in SSR Part-I Section 8, clause 8.24(b) for windows and ventilators.
Supply & fix Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average widht of aperature 1.0mm and fixed with galvanised wire staples complete all as specified and directed.
Material and labour for preparation of new or previously untreated wooden surfaces of any description exceeding 10cm width or grith not otherwise specified and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Supply and fix Soild PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain coloured PVC sheet reinforced with MS Square tube, in opening as per specifications all as specified and as directed.
Supply and fix factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement etc complete all as specified and as directed.
Material & Labour for preparing RCC surface shall be made dry, clean, even and checked for soundness, removal of oil, dirt, laitance and other contaminants by manually and surface shall be fairly smooth finish, shamfering the floor wall junction with CM 1:4 admixed with Nitobond SBR or equivalent @ 1 Litre per 50 kg bag of cement. Down take rain water pipe annular space packing using Conbextra GP2 or equivalent mixed water and filling as per manufacturer's specification. Water ponding for min 48 Hrs and injection grouting of construction joints, leaking spot and honey combs with cementitious pressure grouting with 40 psi pump using Cebex 100 or equivalent @ 225 gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar. Providing and applying water proof coating using Fosroc Nitoproof 600 or equivalent, over dry surface and 1.5 mm thick with 2 coats with interval period of 6 hrs over a substate at a coverage rate of 2 kg/ sqm using spray/ squeegee/ roller/ brush. Water proofing coating shall have the elongation of 500-700% (ASTM D412-90) tear resistance of 21 KN/m(ASTM D624-00), and tensile strength of > 1.9N/mm2(ASTOM D412-90), Termination to be done on wall extending the coating to min 300 mm height above the finished floor level as per vendor recommendation. Laying 200 gsm non woven geo textile membrane over Nitoproof 600 coating with overlap sealed before providing screed concrete complete all as per manufactures instruction and as direcetd by Engr-in-charge. Make FOSROC/Dr fixit or equivalent as given in approved list of makes.
Supply and fix 250mm long alumimum alloy, anodized sliding door bolts with hasp staple (bolt type and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and as directed.
Supply and fix 150mm long alumimum alloy, anodized sliding door bolts with hasp staple (bolt type and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and as directed.
Supply and fix 100mm thick medium weight cold rolled mild steel butt hinges (ISI) complete all as specified and as directed.
Supply and Fix aluminium bow handles size 150mm long cast type anodised complete all as specified and as directed.
Supply and Fix extruded aluminium anodized barrel tower bolts 200 mm long and fixed complete all as specified and as directed.
Material and labour for Brick work with sub class 'B' brick straight or curved to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed.
Material and labour for 10mm thick rendering in cement mortar 1:6, on fair faces of brick/concrete surfaces finished even and smooth with out using extra cement all as specified and as directed.
Material and Labour for Rendering cement plaster on stone/brick masonary surfaces in two coats, 8mm thick in CM 1:4 and mixing with waterproofing compound @ 3% of total weight of cement over 12mm thick in CM 1:6 on external faces of walls finished even and fair complete all as specified and directed. NOTE: Water proofing compound shall be measured and paid separately.
Material and labour for 5 mm thick rendering on concrete ceiling surfaces in CM 1:3, finished even and smooth without using extra cement all as specified and as directed.
Supply only integral water proofing compound complete all as specified and as directed.
Taking down galvanised iron steel tubing 15 mm bore with all fittings including cleaning complete all as specified and as directed.
Taking down galvanised iron steel tubing 20 mm bore with all fittings including cleaning complete all as specified and as directed.
Taking down galvanised iron steel tubing 25 mm bore with all fittings including cleaning complete all as specified and as directed.
Dismantling/taking down PVC/CI soil/waste pipes 100mm/75mm bore with all fittings complete all as specified and as directed.
Supply and fixing aluminium three track sliding windows FRAME top & sides (section No.4310) of size 91.80x31.75x1.2mm weighing 0.826kg/m, frame bottom (section No.4309) of size 91.80x31.75x1.2mm weighing 1.015kg/m, SHUTTER vertical member (section No.8979) of size 40X18X1.2 weighing 0.379kg/m, shutter inter lock vertical frame (section No.8980) of size 40X18X1.2 weighing 0.488kg/m, shutter top & bottom horizontal frame (section No.8853) of size 40X18X1.2 weighing 0.428kg/m, with powder coating of thickness 50-60 micron with one or more rebates, including necessary jointing cleats, glazing clips, rubber packing, anodised snap beading, screws aluminium fitting handles, locking arrangement etc including 4.00 mm thick sheet glass for glazed shutters and stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm for wire guage shutter all as specified and as directed. Note: (i) The window opening shall be provided with 3 shutters of equal width. (ii) Two shutters shall be glazed shutters and one shutter shall be with stainless steel wire. (iii) Sheet glass & figured glass shall be included in quoted rate.
Supply & fix Powder coated aluminium ventilator louvered type without sash bar section as per minimum 15 microns anodised including necessary jointing, clip, rubber packing, anodised snap beading screws and 4mm thick pin headed glass etc completle all as specified and as directed.
Material and labour for aluminium powder coated fixed type window/ ventilator using standard aluminium sections with powder coating of thickness 50-60 micron, shutter without sash bar, with 4 mm thick plain sheet glass with necessary rubber beading, locking arrangements and including glazing clips all as specified and directed. (i) Frame (Jindal) (SP) - 20052 (ii) Frame (Jindal) (DP) - 20051 (iii) Glazing clip - 19352 NOTE: (i) Glass panel shall be measured and paid separately. (ii) Quoted rate shall be inclusive of cost of Glazing clips.
Supply and fixing 4mm thick sheet glass, frosted type and glazing with oil putty in square not exceeding 0.5 Sqm in each pane all as specified and as directed.
Supply and fix in repairs Vitreous china wash down water closet pan pedestal pattern white with and including fixing bolts, seat cover black closed pattern with flat bottom, mild steel chromium plated or aluminised hinging device, antisyphonage pipe and connection to drainand to flushing pipe but excluding PVC flushing cistern and flush pipe complete all as specified and as directed. Make: Cat No.C0297/C298 of Parryware or equivalent make as given in approved list of makes
Supply & fixing in repair wash basin vitrous china, white, flat back of size 550x400mm including brackets cutting for and pinning in ends of brackets or erecting stand including waste pipe, brass chromium plated perforated waste coupling/fittings 32mm dia with long screwed shanks and fly nuts, flange ended in red lead cement, 32mm dia LDPE waste pipe suitable length of pressure rating 6Kg/Sqcm complete all as specified and directed.
Supply and fix in repair of PVC valveless syphonic action type flushing cistern 10 ltr capacity low level, white with inlet, ball valve float and handle including brackets complete all as specified and as directed.
Supply and Fixing in repair Vitreous china urinal, small, coloured, Size 340 x 280 X 470 MM flat back with grating and union for discharge (Excluding flushing cistern flush pipe and waste pipe) complete all as specified and as directed.
Supply and fixing flush pipe of polyethylene of low or high density of 32 mm dia for low level flushing cistern all as specified and as directed.
Supplying and fixing of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings confirming IS-15778 in walls complete all as specified and as directed.
All as here-in-before item No. 46, but of 20mm dia
All as here-in-before item No. 46, but of 40mm dia
Supply and fixing PVC connection 15 mm outer dia and 450 mm long PTMT nuts suitable heavy duty complete all as specified and as directed.
Supply and Fix in repairs 15mm bore pillar taps, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered “HOT” or “COLD” with long screwed shanks and fly nuts complete all as specified and as directed. Make: CERA Cat No.F3002101 or equivalent as listed in approved makes
Supply and Fix in repairs 15mm dia Bib tap with crutch or butterfly handle, screwed down, screwed for iron pipe, fancy type, cast copper alloy, chromium plated with flange complete all as specified and as directed. Make: CERA Cat No.F3002151 or equivalent as listed in approved makes
Supply and fixing in repairs stop valve cast copper alloy, chromium plated, fancy type screwed down higher pressure with crutch or butterfly handles screwed both ends for iron/CPVC pipes 15 mm bore fixed all as specified and as directed. Make: Jaquar Cat No. FLR-CHR-5083NK or equivalent as listed in approved makes
Supply and fixing in repairs stop valves, cast copper alloy with crutch or butterfly handle, CP with long shank and cup, concealed type, screwed down, high pressure, screwed for iron/CPVC pipe of 15 mm bore all as specified and as directed. Make: Jaquar Cat No. ALD-CHR-083 or equivalent as listed in approved makes
Supply and fix in repairs brass chromium plated toilet paper holder complete all as specified and as directed. Make: Jaquar Cat No. ACN-CHR-1151N or equivalent as listed in approved makes
Supply and fix in repairs stainless steel soap tray,fancy type complete all as specified and as directed. Make: Jaquar Cat No. ACN-CHR-1131N or equivalent as listed in approved makes
Supply & fixing in repair Chromium plated Hand shower (Health Faucet) with 8mm dia 1.2m Flexible Tube with wall hook with N.R.V (Back Flow Preventor) complete all as specified and as directed by Engr-in-Charge. Make: Jaquar Cat No. ALD-CHR-573 or equivalent as listed in approved makes
Supply and fix 20mm dia SS towel rail 600mm long , chromium plated, with and including brackets complete all as specified and as directed. Make: Jaquar Cat No. ACN-BCH-1111SM or equivalent as listed in approved makes
Supply and fix in repairs brass chromium plated shower rose 125mm with or with swivel joints any size including fixing to steel pipe or union complete all as specified and directed. Make: CERA Cat No.F7020101 or equivalent as listed in approved makes
Supply & fix bathroom PVC mirror cabinet of size 12.5 x 44.6 x 55.3 CM complete all as specified and directed. Make: Nilkamal or equivalent as listed in approved makes
Providing & applying two component Elastomeric polymer modified "Shalicem EWP" manufactured by STP Ltd on external wall surface in 2 coats @ 2 kg/sqm resulting an average thickness of 1.5mm including preparation of surfaces all as per manufactures instruction with necessary scaffolding. Make: STP/DR fixit or equivalent as listed in approved makes Note: (i) Both the components are to be mixed as per manufactures instruction and 3 to 5% of water to be added to make brushable consistency (ii)The second coat needs to be applied only after drying of the previous coat. First coat & second coat shall be applied in a perpendicular direction (iii) All works shall be done as per specification. (iv) All works shall be done after surface prepration including scaffolding.
Supply and fixing 110mm bore PVC(SWR) pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
Supply and fixing 75mm bore PVC(SWR) pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
Supply and fix PVC (SWR) multi floor trap 75mm dia with grating including jointing with solvent cement complete all as specified and as directed.
Supply and Fixing PVC (SWR) Bends 110mm dia complete all as specified and as directed.
Supply and Fixing PVC (SWR) Bends 75mm dia complete all as specified and as directed.
Supply and fixing 110mm bore PVC (SWR) branch piece single (single Y) equal or unequal complete all as specified and as directed.
Supply and fixing 75mm bore PVC (SWR) branch piece single (single Y) equal or unequal complete all as specified and as directed.
Material and labour for salt glazed stone ware gully traps, square or round mouthed, type 'P', 150 mm x 150mm all as specified and as directed.
Supplyand fixing powder coated aluminium curtain rails, fancy type including brackets 20 mm dia all as specified and as directed.
Material and labour for preparation of old treated steel/iron surfaces of any description exceeding 10cm width or girth not otherwise specified and applying one coat of synthetic enamel paint (Ist quality) complete all as specified and as directed.
Material and labour for complete removal of existing treatment, preparing surfaces and applying two coats of oil bound distemper over a coat of alkali resistance primer over 3mm thick Birla white wall care putty on walls complete all as specified and as directed.
Material and labour for complete removal of existing treatment, preparing surfaces and applying two coats of oil bound distemper over a coat of alkali resistance primer over 3mm thick Birla white wall care putty on ceiling complete all as specified and as directed.
Material and labour for complete removal of existing treatment, preparing surfaces and applying two coats of anti-fungal exterior emulsion paint over a coat of primer on walls complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistance primer over 3mm thick Birla white wall care putty on walls complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces and applying two coats of anti-fungal exterior emulsion paint over a coat of primer on walls complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces and applying two coats of oil bound distember over a coat of alkali resistance primer over 3mm thick Birla white wall care putty on ceiling complete all as specified and as directed.
Supply and fix urinal spreader for fixing with 15mm dia pipe complete all as specified and as directed. Make: F8070201 of Cera or equivalent as listed in approved makes
Material and labour for grinding and mirror polishing of Kota stone floor complete all as specified and directed.
Material and labour for applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces over 10 cm width or girth including preparation of surfaces complete all as specified and as directed.
Chipping, removing, carefully loose plaster by low impact hammer without damaging the structure and cleaning the disposal of malba out side the premises etc. complete all as specified and as directed by Engr-in-charge.
Chipping, Removing, carefully Loose concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete all as specified and as directed by Engr-in-charge. Note: Hard concrete should not be removed by force.
Cleaning exposed reinforcing bars thoroughly to remove corrosion scale using buffing wheel and emery cloth with water jet and applying two coats of Nitozinc primer complete all as specified and as directed by Engr-in-charge. Make : Fosroc/ Dr fixit or equivalent as approved list of makes.
Material and labour for providing 50x50x4mm welded mesh coated with anti corrosive chemical to exposed bars using binding wire complete all as specified and as directed by Engr-in-charge.
Material and labour for providing structural grade epoxy-latex bond coat prior to application of any type of mortar confirming to ASTM-C- 882-91 (Arizona Slant Shear Test) to ensure bond between old concrete & new concrete by brush application complete all as specified and as directed by Engr-in-charge. Make:Pidilite/Fosroc/Shalimar
Material and labour for building up the profile of structural members by using latex B2 modified air cured mortar system in damaged areas (1 Cement-3 part graded cleaned pre-packed river sand 10% latex mortar by weight of cement-0.5 w/c ratio) in 20 mm thickness including levelling profiling etc complete all as specified and as directed by Engr-in-charge. Make- Pidilite/Fosroc/Shalimar.
Removing completely existing water proofing treatment of any description and of any type including top layer of plaster/ china mosaic wherever occurs over roof and chajjah surfaces and scrubbing the surface with wire brush and cleaning washing down with water to receive new cement plaster/PCC layer and removing the waste material/debris to a distance exc. 1500m but n.exc. 5km complete all as specified and as directed by Engr-in-charge.
Material and labour for 15mm thick plastering over the floor and side walls of sunken portion in CM 1:3 mixed with WPC of approved quality @ 1Kg per bag of cement including rounding of all corners wherever required, smooth, rendering, curing etc complete all as specified and as directed by Engr-in-charge.
Material and labour for applying Roof treatment with APP modified water proofing membrane weighing not less than 3 kg/sqm reinforced with non woven polyster matt weighing not less than 150 gms/sqm laid as per manufacture's instruction including applying bitumen primer at 0.20 kg/Sqm and applying of one coat of blown grade hot bitumen 85/25 IS 702 heated to a working temperature of 180˚C over the membrane @1.20 kg /Sqm and solar reflective bituminous aluminium paint for thermal insulation @0.10 kg/sqm over APP membrane complete all as specified and directed.
Material and labour for providing 25mm thick plain cement concrete 1:2:4 mix type B0, using 12.5mm graded stone aggregate as in levelling course over RCC roof using water proofing compound @3% by weight of cement complete all as specified and directed.
Taking down the existing old unserviceable point wiring of any description for old light/fan/socket/power including terminal boards, switches, sockets, ceiling roses etc, taking out old gutties, screws, nails etc and making good the disturbed surface of walls/ceiling etc complete all as specified and directed.
Taking down MCB DBs /TPN DBs along with MCB complete all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, multi stranded with copper conductor and including PVC casing and caping, medium grade with accessories in wall/roof/ceiling etc, ISI marked with suitable modular cover plate with frame and metal flush box and 1.5 sqmm FRLS PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor and connecting to common earth dolly complete all as specified and as directed for the following. Note: (i) Switch and socket to be measured and apid seperately. (ii) Cost of modular cover plate with frame & metal flush box is deemed to be included in quoted rates. (iii) Cost of cutting and grooving of any type of masonry wall/ floor for fixing of PVC casing and caping and making good the disturbed surfaces matching to existing surfaces is deemed to be included in quoted rates
One light/fan point controlled by one switch.
One 3 pin socket outlet 5 Amps on Independent board.
One light controlled by 2 way switch with cable 1.5Sqmm size.
One 3 pin socket outlet 5 Amps on same board.
Material and labour for point wiring complete with 4 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, multi stranded with copper conductor and including PVC casing and caping, medium grade with accessories in wall/roof/ceiling etc, ISI marked with suitable modular cover plate with frame and metal flush box and 4 sqmm FRLS PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor and connecting to common earth dolly for One 3 pin socket outlet 15 Amps on Independent board complete all as specified and as directed. Note: (i) Switch and socket to be measured and apid seperately. (ii) Cost of modular cover plate with frame & metal flush box is deemed to be included in quoted rates. (iii) Cost of cutting and grooving of any type of masonry wall/ floor for fixing of PVC casing and caping and making good the disturbed surfaces matching to existing surfaces is deemed to be included in quoted rates.
Supply and fix Modular switch, one way, 6Amps, one module, AC 230V, ISI marked complete all as specified and directed.
Supply and fix Modular switch, two way, 6Amps, one module, AC 230V, ISI marked complete all as specified and directed.
Supply and fix Modular switch, one way, 16Amps, one module, AC 230V, ISI marked complete all as specified and directed.
Supply and fix Ceiling rose in poly carbonate 3 plates flush type 6 Amps, 230 volts AC ISI marked, complete all as specified and directed.
Supply and fix Modular Switch Socket Combination, 6 pin, 16 Amps 2 module 230 volts AC ISI marked, complete all as specified and directed.
Supply and fix Modular socket outlet, 6 Amps, 2 and 3 pin combined two modules 230 volts AC ISI marked, complete all as specified and directed.
Supply & fixing modular electronic fan regulator 120W, 2 module complete all as specified and as directe
Supply and fixing in MCB distribution board in sheet metal enclosure, powder coated, factory made IP 43 protection, IP 09 double door type SPN 8 way with 200 Amps, 230 Volt rated bus bar neutral and earth connected bars for use of MCB 32 Amps, SPN fixed properly at directed place by using suitable required fixing arrangement all as specified and as directed.
Supply and fix in relpacement MCB SPN, 240 Volts, 32 Amps, 'C' series breaking capacity of 10KA complete all specified and as directed.
Supply and fix in relpacement MCB SP, 230 Volts, 6-32 Amps, 'C' series breaking capacity of 10KA complete all specified and as directed.
Supply and fixing in MCCB distribution board in sheet metal enclosure, powder coated, factory made IP 43 protection, IP 09 double door type TPN 8 way with 250 Amps, 440 Volt rated bus bar neutral and earth connected bars for use of MCCB 16 Amp fixed properly at directed place by using suitable required fixing arrangement all as specified and as directed.
Supply and fixing LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with suitable GI pipe bracket 1.5M long bent to shape and fixed with brackets complete all as specified and as directed.
Supply & fix LED wall bracket light 10W capacity with B22d & E27 lamp holder complete all as specified and as directed.
Supply & fix LED lights fitting 1x 20W, 220V, AC decorative box type with driver holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Material and labour for Sub main wiring complete with 2 runs of 4 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor and one run of earth continuity conductor of 4 sqmm PVC insulated copper wire drawn through and including PVC casing and caping including taking down of old wire and making good to disturbed surfaces of wall and match with existing surface complete all as specified and as directed. Note : 3 runs of 4 sqmm cable and one run of PVC casing and caping shall be measured as one length all as specified.
Material and labour for Sub main wiring complete with 4 runs of 10 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor and one run of earth continuity conductor of 10 sqmm PVC insulated copper wire drawn through and including PVC casing and caping including taking down of old wire and making good to disturbed surfaces of wall and match with existing surface complete all as specified and as directed. Note : 5 runs of 10 sqmm cable and one run of PVC casing and caping shall be measured as one length all as specified.
Taking down the ceiling fans single pole, AC, 230V, 50Hz, 1200/1400mm sweep 230V for repair, replacement of minor nuts, bolts, washers etc, painting, greasing/oiling, re-assembling, refixing and testing complete all as specified and directed.
Supply and laying UG cable XLPE insulated, screened, PVC bedded, galvanised steel wire/strip armoured electric power cables, heavy duty LT 1100 Volt grade, with aluminium conductor of size 50Sqmm 3.5 core in trenches/fixing on wall/ poles/ passing through pipes complete all as specified and as directed. NOTE: Excavation and earth work shall be measured and paid separately.
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in Electrical Plate No.3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab(300 x 300 x 50mm), GI funnel with 20 mm dia watering pipenot of 1.5m long, wire mesh, 15mm dia light grade GI protection pipe for earth lead not less than 7.5 m etc., complete
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for laying of LT under ground cable complete all as specified and as directed.
Returning filling in soils including spreading, levelling, watering and well ramming in layers not exceeding 25 cm all as specified and as directed
Removal of excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. .
Material and labour for sand cushioning in cable trenches using clean, dry river sand including spreading, punning down and levelling all as specified and as directed. NOTE: Punned thickness shall be measured and paid.
Supply and lay old bricks sub class 'B' for cable protection laid trenches all as directed.
Supply, fabricate, erect, connecting, testinf and commissoning of LT panel, indoor type, weather and vermin proof made out of 2mm thick CRCA sheet with front opening and locking arrangment epoxy powder coated having colour siemens grey 600 amps capacity aluminium bus bar for phase phase 3 nos and 1 No 400 amp bus bar for neutral mounted on epoxy insulator including necessary copper control wiring, heat shrinkable, RYB coloured sleaves over bus bar for identification, floor mounting angle iron base earth shields, circular holes at bottom/ top to receive incoming and outgoing cable, cable lugs, cable gland of sizes 40x40x6mm as required pannel suitable for the following control/ fitments sensible for 3 phase 50 Hz, 415 V system complete comprising the following and including necessary PCC 1:3:6 / Brick work for mounting of panel.
Thermal magnetic adjustable MCCB 415 V 50 HZ 4 pole 630 Amp breaking capacity 50 KA-01 No. as Incomer
Thermal magnetic adjustable MCCB 415 V 50 HZ 3 pole 160 Amp breaking capacity 35 KA-05 Nos. as outgoing
Multidigital meter-01 No.
Indicating Lamp LED type- 01 Set
Thermal magnetic adjustable MCCB 415 V 50 HZ 3 pole 32Amp breaking capacity 10 KA-02 Nos.
CT 630/5A-03 Nos
M/s S.D Construction Co
VIJAYA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .