Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹20.0 L+₹3.3 L (19.6%)Rejected-Finance H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L2 | Rejected-Finance Other than lowest |
Tender Value
₹22.5 L
EMD Value
₹45,000
Closing Date
7 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
PROVN OF CHANGE OF SERVICE CABLE, PANEL AND ALLIED EQUIPMENT IN ZONE IV AND ZONE VI AND PROVN OF 15 LTR GEYSERS FOR JCOs/ORs LIVING ACCN AT DHURMUND UNDER GE (I) 873 EWS
2022_MES_550174_1
NIT-51 of 22-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE(I) 873 EWS
₹45,000
Yes
21 Oct 2022
6 Sept 2022
10 Oct 2022
6 Sept 2022
7 Oct 2022
23 Sept 2022
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Laying only brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Steel pipe galvanised light grade, 50 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Steel pipe galvanised light grade, 80 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Cable route marker with route indication on cast iron disc of 150mm dia and 10mm thick, marked/written for "LT cable 1100 VOLTS" embosed including indication direction fixed/ bolted to 40mmx40mmx6mm thick MS angle iron support of 0.50m long embedded upto 200mm depth in concrete block of size 200mmx200mmx50omm casted in PCC 1:3:6 type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surfaces, complete all as specified and as directed.
Bus bar panel size 0.8x0.4x0.4 Mtr, KISOK, outdoor type, CRPI tested, LT 440 Volts, 50 Hz, 3 phase 4 wire supply, comprising of bus bas chamber with 4 Nos aluminium strip bus bars PVC insulated with colour coding af rating 200A, floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 thick MS sheet CRCA on angle iron 30x30x4mm frame with front opening doors, locking arrangement, powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufactures in PCC 1:3:6 type C-1, using 20 mm graded crushed stone aggregate as directed by the Engr-in-Charge including earth work complete all as specified.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 2 core fixed with suitable thimble and gland laid in trenches, under floors or on poles including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 25 Sqmm 4 core fixed with suitable thimble and gland laid in trenches, under floors or on poles, including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 35 Sqmm 4 core fixed with suitable thimble and gland laid in trenches, under floors or on poles, including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 50 Sqmm 4 core fixed with suitable thimble and gland laid in trenches, under floors or on poles, including taking down old cable, complete all as specified and as directed.
1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia suspension GI wire with stranded conductor 10 Sqmm twin core cable flat or circular including taking down old, complete all as specified.
1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia suspension GI wire with stranded conductor 16 Sqmm twin core cable flat or circular including taking down old, complete all as specified.
Junction box water proof outdoor type made out of SMC of external dimensions 250x250x105mm, sigle door type hinged with locking arrangement front operated with one number MCB 06 Amps capacity for housing 3 phase and neutral busbar including connecting the incoming/outging cables including cable glands , SMC coated coated clamps, nuts and bolts etc. all as directed and fixed to existing poles with mild steel flat of size 25mm x 4mm. Make: Sintex Cat Part No. GSTB 2520 or eqivalant in Hensel
Sheet metal enclosures for DB’s, single door, (when MCBs are to be used) single pole and neutral 2 way, 240 volts , complete all as specified.
2.5sqmm x3 core unarmoured copper cable for connection to street light fitting including taking down old complete all as directed.
Point wiring with 2.5 Sqmm, multistrand, FRLS copper conductor cable, PVC insulated and unsheathed, drawing in and including PVC casing-N-caping of appropriate size (having wall thickness not less than 0.90mm), surface type, for one light point controlled by one, one way switch, terminated in terminated in cast iron or pressed steel terminal boxes appropriate size, covered with 3mm thick plastic laminated sheet top cover for mounting switches, sockets, regulators etc. and continuous PVC insulated and unsheathed 2.5 Sqmm copper conductor cable multistrand as earth wire, complete all as specified.
Switch Socket combination, 2 in 1, 3 pin, 5 & 15 Amp, flush type universal with fuse and neon indicator, complete all as specified.
Cutting and unscrewing existing steel tubing of size 15mm dia for alteration or additions or lengthening screw on pipe to form connector and done in position without taking down, complete all as specified and as directed.
GI water tubing, medium grade, with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.fixed to wall or under floors, bore of pipe 15mm, complete all as specified & directed.
Stop valves, 15mm bore, fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specifed.
Bib tap, 15mm bore, fancy type, chromium plated , cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule,fixed in repairs, complete all as specified and directed.
PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified.
Storage water heater (Geyser), vertical type, of 25 ltr capacity of inner tank, outer tank, syphon assembly, thermostat heating element, safety valve etc complete all as per manufacturer design and specifications including making of all fixing arrangements complete having BEE Five Star Rating including grouting of nuts and bolts and necessary PCC work all as specified and directed by Engineer-in-Charge. Make:- VENUS 'SPLASH 02 GL' / RACOLD 'ETERNO 2 25 V' / BAJAJ 'MAJESTY 25L GMU' / HAVELLS 'PURO PLUS 25L'
MCB, single pole and neutral, 40 to 63 Amp, 10 KA, 240 Volt, complete all as specified.
MCB, single pole, 6 to 32 Amp, 10 KA, 240 Volt, complete all as specified.
Supplying, installing, designing, testing and commissioning of LT outdoor type Panel Board, Factory made, (Cubical kiosk type), CPRI tested, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick MS Sheet CRCA on angle iron 40X40X6mm frame of size and size of panel (1.5 x 1.0 x 0.5 mtr) suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 type C-1 , using 20 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of following :
(i) Incoming (a) Bus bar PVC insulated made of copper strip of size suitable for 200A current. PVC sheathed with colour coding. (b) MCCB 100 Amps, breaking capacity 16 KA, FP, 415V, 300mA/200mA as reqd (Note Each MCCB shall have shunt trip coil duly wired up to TB for external contact interface- 01 No (ii) Outgoing (a) MCB 3 x 32A, SPN, C-type, 10 KA for feeding to switch board or as required. (b) MCB 6 x 20A, SPN, C-type, 10 KA for feeding to power points/switch board or as required. (c) MCB 3 x 16A, SPN, C-type, 10 KA for feeding to power to switch board or as required. (d) LED pilot lamp RYB (Set of three)-01 No
(e) Complete control panel wiring with suitable size stranded copper conductor Make of Panel : DV Electromatics Private Limited / Simon Fabricators / Electricfield Co / Adhunik Switchgear / Universal Switchgear Make of MCB & MCCB : L&T / Legrand / Schneider / Havells
M/S BALI CONSTRUCTIONS
Bidder Name
M/S BALI CONSTRUCTIONS
M/S Builders Indias
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .